Orthodontic Appliance ComplicationNCT03572179
Evaluation of Fixed Mandibular Retainer Using 3D Printed Positioning Tray Versus Direct Bonding Technique
A study testing 3d printed positioning tray in people with Orthodontic Appliance Complication, run by Raghda Alaa at 1 site in Egypt.
Trial summary
Although there are many studies in the literature concerning methods of bonding of mandibular retainers whether directly or indirectly, there is a very limited evidence regarding their chair side time and bond failure. Read more about this study
- Who is it for?
- Any ageHealthy volunteers can take part
- Conditions the study is for
- Orthodontic Appliance Complication
- What is being tested?
- 3d printed positioning tray
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 20 participants
- Where
- 1 siteEgypt
- Study dates
- 1 Mar 2019to 28 Mar 2020
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages Any age
- All sexes
- Healthy volunteers accepted
- Child, Adult, Older adult
Who may be able to join
- • Patients with properly finished orthodontic treatment according to ABO standards.
- the presence of the 4 mandibular incisors and the 2 mandibular canines,
- No active caries, restorations, fractures, or periodontal disease of these teeth
- Patient with Good oral hygiene
Who cannot join
- • Patients with no need of fixed bonded mandibular retainer
- No or poor patient's co operation
- Abnormal morphology of anterior teeth
- Bad oral hygiene
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Evaluation of Fixed Mandibular Retainer Using 3D Printed Positioning Tray Versus Direct Bonding Technique A Randomized Clinical Trial
Although there are many studies in the literature concerning methods of bonding of mandibular retainers whether directly or indirectly, there is a very limited evidence regarding their chair side time and bond failure. Also there are scarce data on fixed mandibular retainers bonded using 3D printed positioning tray.Thus, conducting a well-designed randomized clinical trial evaluating the chair side time and bond failure of 3d printed positioning tray and direct bonding method of fixed mandibular retainer.Null hypothesis is thatThe time needed for direct indirect bonding using 3D digital positioning tray of a mandibular fixed retainer is shorter than the time needed for direct bonding, and there is no difference in failures between the 2 bonding methods
Read the detailed description
Statement of the problem:
- Although there are many studies in the literature concerning methods of bonding of mandibular retainers whether directly or indirectly, there is a very limited evidence regarding their chair side time and bond failure. Also there are scarce data on fixed mandibular retainers bonded using 3D printed positioning tray.
Choice of the comparator:
In the ongoing study, direct bonding of mandibular fixed retainer will be the control group. Thus, conducting a well-designed randomized clinical trial evaluating the chair side time and bond failure of 3d printed positioning tray and direct bonding method of fixed mandibular retainer.
Study rationale:
To evaluate and compare bond failure and chair side time by 3D printed positioning tray and direct bonding method of mandibular fixed retainer.
Null hypothesis:
- The time needed for direct indirect bonding using 3D digital positioning tray of a mandibular fixed retainer is shorter than the time needed for direct bonding, and (2) there is no difference in failures between the 2 bonding methods. Research question: Will the 3D digital positioning tray reduce chair side time, bond failure during retainer placement in patient with need of fixed bonded mandibular retainer, when compared to direct bonding method? Aim of the study: To evaluate chair side time and bond failure of 3D digital positioning tray during mandibular retainer placement and direct bonding of mandibular retainer.
- Objectives Primary objective To evaluate effect of 3D Digital positioning Tray on chair side time Secondary outcome Immediate bond failure and bond failure during first 6 month of placement of mandibular fixed retainer. PICOTs format: P: patient with the need of fixed bonded mandibular retainer after orthodontic treatment I: 3D printed Digital positioning Tray for bonding mandibular retainer. C: conventional direct bonding of mandibular retainer O: chair side time, immediate bond failure and bond failure during first 6 month. Outcome Name,Measuring Tool and Measuring unit Primary is the Chair side Time measured by Digital stopwatch in Seconds Immediate Bond Failure is the Number of Debonded mandibular fixed retainer measured in Numerical value Bond failure during first 6 month follow up by the Number of Debonded mandibular fixed retainer measured in Numerical value T: Immediate and T2: 6 month follow up S: Randomized controlled trial.
- Trial Design This trial is designed as a parallel, randomized, controlled trial with allocation ratio 1:1.It will be performed at the educational hospital of the Faculty of Oral \& Dental Medicine, Cairo University.
Materials \& Methods:
- Participants, Intervention and Outcomes
- Study setting:
- Source of patients: patients who finished their orthodontic treatment at the outpatient clinic in Orthodontic department, Faculty of Oral and Dental Medicine, Cairo University, Cairo government, Egypt.
- Time: 2017-2018 The study will last for 6 months.
- Intervention Treatment Group After finishing orthodontic treatment, all patient will receive a modified indirect technique for bonding fixed mandibular retainer and the key of modification is the fabrication of 3D printed digital positioning tray for placement of retainer with holes for composite pads for its direct application using 3 shape Ortho analyser Software ® instead of conventional indirect retainer fabrication method The sample selection and screening for inclusion of patients in clinical trial will be performed at all patients at clinic of Orthodontic department, Faculty of Oral and Dental Medicine, Cairo University.
Scanning of impression and designing the digital tray Lower impression is taken for each patient and the cast will be carefully scanned by desktop laser scanner for production of digital cast, using 3 shape ortho analyser Software®, the tray will be designed Fabrication and printing of the digital tray Using Dent1 3D printer® (Mogassam®, Greek campus, Cairo, Egypt), the tray will be printed Clinical application of the digital tray
- Teeth to be bonded are polished and etched.
- Teeth isolation \& moisture control are achieved.
- Dead Soft Stainless Steel wire is placed and adapted in its place in the digital tray.
- Placement of the tray in the patient mouth on the prepared teeth
- Adhesive bond is applied to teeth and then curing of the adhesive bonding.
- 3M ® composite (3M Unitek company , Monrovia, California, USA) is placed in the printed tray holes and any excess composite will be removed and then light curing is done.
- Time will be recorded during this step
Removal of digital tray After insuring complete curing of the composite the digital tray is then removed from patient mouth, Bond failure of composite pads will be checked in this step and recorded.
Control Group All patients of this group will follow conventional steps of direct bonding procedure of fixed mandibular retainer
- Pumice and polish the lingual surface of teeth on which retainer is to be bonded
- The retainer wire is prefabricated by incorporating perpendicular pieces of 1.5"-2" ligature wire at interdental region of respective teeth
- The retainer wire is then adapted on the tooth surface. The short ligatures are passed interdentally one occlusal to contact point and other gingival to contact point and tied over.
- Bonding procedure after etching and application of sealant is carried out.
- Enough adhesive should be used. Light curing is done.
- 3M ® composite (3M Unitek company, Monrovia, California, USA) is placed then light curing is done.
- Cut the ligature wires and pull them laically to disengage.
- Time will be recorded during this step
- Sample Size calculation: the sample is increased to a total size of 20 participants; 10 in each arm.
- Recruitment strategy:
- Patients will be selected from the outpatient clinic of the orthodontic Department - Cairo University
- Consecutive sampling is done through screening of patients. This will continue until the target population is achieved.
- Identifying and recruiting potential subjects is achieved through patient database.
II. Assignment of Interventions
- Sequence generation:
It will be performed as 1:1 allocation. The sequence of the two groups will be done by computer generated random numbers. This will be done by using Microsoft Office Excel 2013 sheet
- Allocation Concealment:
Random numbers obtained by random sequence generation will be written on white papers, each paper will be kept in sealed envelope. Sealed envelopes will be kept in box at the secretary of orthodontic department office.
- Implementation:
Implementation will be carried out in the secretary of the orthodontic department at the Faculty of Oral and Dental Medicine, Cairo University.
- Blinding:
Participants Patients can detect the transfer tray so blinding is not possible Operator The main operator is responsible for the bonding so the blinding is not possible Assessor The assessor (different from main operator will carry out the measurement blindly
- Conditions
- Orthodontic Appliance Complication
- Being tested
- 3d printed positioning tray
- Keywords
- 3d printed positioning tray
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
3d printed positioning trayDevice
3d printed positioning tray for lingual fixed retainer placement in treatment group
| Study group | Role | What they receive |
|---|---|---|
| Treatment Group | Active comparator | After finishing orthodontic treatment, all patient will receive a modified indirect technique for bonding fixed mandibular retainer and the key of modification is the fabrication of 3D printed digital positioning tray for placement of retainer with holes for composite pads for its direct application using 3 shape Ortho analyser Software ® instead of conventional indirect retainer fabrication method Receives: Device: 3d printed positioning tray |
| Control Group | No intervention | All patients of this group will follow conventional steps of direct bonding procedure of fixed mandibular retainer |
What is being measured
The primary outcome is the main question the study is designed to answer.
chairside time
chairside time for bonding fixed lingual mandibular retainer using stopwatch in measured seconds
Measured: follow up up to 6 month
Secondary outcomes (1)
bond failure
bond failure of composite per tooth measuered in numerical value
Measured: 6 month follow up
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted28 Jun 2018
- Study start1 Mar 2019
- Primary completion1 Mar 2019
- Study completion28 Mar 2020
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Orthodontic Appliance ComplicationStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Model description
- all patient will receive a modified indirect technique for bonding fixed mandibular retainer and the key of modification is the fabrication of 3D printed digital positioning tray for placement of retainer with holes for composite pads for its direct application using 3 shape Ortho analyser Software ® instead of conventional indirect retainer fabrication method
- Masking
- Single blind
- Who is masked
- Outcomes assessor
- Enrolment
- 20 participants (actual)
Sponsor and investigators
- Lead sponsor
- Raghda Alaa
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor-investigator, Raghda Alaa, Cairo University
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03572179
- Sponsor's protocol ID
- CEBD-CU-2018-04-28
- Status last verified
- Aug 2021
- First submitted
- 9 Jun 2018
- Last updated
- 5 Sep 2021
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 5 Sep 2021. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Evaluation of Fixed Mandibular Retainer Using 3D Printed Positioning Tray Versus Direct Bonding Technique A Randomized Clinical Trial
- ClinicalTrials.gov ID
- NCT03572179
- Acronym / sponsor ID
- CEBD-CU-2018-04-28
- Conditions
- Orthodontic Appliance Complication
- Keywords
- 3d printed positioning tray
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 20 participants (actual)
- Lead sponsor
- Raghda AlaaUniversity, hospital or other
- Study start
- 1 Mar 2019 (actual)
- Primary completion
- 1 Mar 2019 (actual)
- Study completion
- 28 Mar 2020 (actual)
- First posted
- 28 Jun 2018 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Although there are many studies in the literature concerning methods of bonding of mandibular retainers whether directly or indirectly, there is a very limited evidence regarding their chair side time and bond failure. Also there are scarce data on fixed mandibular retainers bonded using 3D printed positioning tray.Thus, conducting a well-designed randomized clinical trial evaluating the chair side time and bond failure of 3d printed positioning tray and direct bonding method of fixed mandibular retainer.Null hypothesis is thatThe time needed for direct indirect bonding using 3D digital positioning tray of a mandibular fixed retainer is shorter than the time needed for direct bonding, and there is no difference in failures between the 2 bonding methods
Detailed description
Statement of the problem:
- Although there are many studies in the literature concerning methods of bonding of mandibular retainers whether directly or indirectly, there is a very limited evidence regarding their chair side time and bond failure. Also there are scarce data on fixed mandibular retainers bonded using 3D printed positioning tray.
Choice of the comparator:
In the ongoing study, direct bonding of mandibular fixed retainer will be the control group. Thus, conducting a well-designed randomized clinical trial evaluating the chair side time and bond failure of 3d printed positioning tray and direct bonding method of fixed mandibular retainer.
Study rationale:
To evaluate and compare bond failure and chair side time by 3D printed positioning tray and direct bonding method of mandibular fixed retainer.
Null hypothesis:
- The time needed for direct indirect bonding using 3D digital positioning tray of a mandibular fixed retainer is shorter than the time needed for direct bonding, and (2) there is no difference in failures between the 2 bonding methods. Research question: Will the 3D digital positioning tray reduce chair side time, bond failure during retainer placement in patient with need of fixed bonded mandibular retainer, when compared to direct bonding method? Aim of the study: To evaluate chair side time and bond failure of 3D digital positioning tray during mandibular retainer placement and direct bonding of mandibular retainer.
- Objectives Primary objective To evaluate effect of 3D Digital positioning Tray on chair side time Secondary outcome Immediate bond failure and bond failure during first 6 month of placement of mandibular fixed retainer. PICOTs format: P: patient with the need of fixed bonded mandibular retainer after orthodontic treatment I: 3D printed Digital positioning Tray for bonding mandibular retainer. C: conventional direct bonding of mandibular retainer O: chair side time, immediate bond failure and bond failure during first 6 month. Outcome Name,Measuring Tool and Measuring unit Primary is the Chair side Time measured by Digital stopwatch in Seconds Immediate Bond Failure is the Number of Debonded mandibular fixed retainer measured in Numerical value Bond failure during first 6 month follow up by the Number of Debonded mandibular fixed retainer measured in Numerical value T: Immediate and T2: 6 month follow up S: Randomized controlled trial.
- Trial Design This trial is designed as a parallel, randomized, controlled trial with allocation ratio 1:1.It will be performed at the educational hospital of the Faculty of Oral \& Dental Medicine, Cairo University.
Materials \& Methods:
- Participants, Intervention and Outcomes
- Study setting:
- Source of patients: patients who finished their orthodontic treatment at the outpatient clinic in Orthodontic department, Faculty of Oral and Dental Medicine, Cairo University, Cairo government, Egypt.
- Time: 2017-2018 The study will last for 6 months.
- Intervention Treatment Group After finishing orthodontic treatment, all patient will receive a modified indirect technique for bonding fixed mandibular retainer and the key of modification is the fabrication of 3D printed digital positioning tray for placement of retainer with holes for composite pads for its direct application using 3 shape Ortho analyser Software ® instead of conventional indirect retainer fabrication method The sample selection and screening for inclusion of patients in clinical trial will be performed at all patients at clinic of Orthodontic department, Faculty of Oral and Dental Medicine, Cairo University.
Scanning of impression and designing the digital tray Lower impression is taken for each patient and the cast will be carefully scanned by desktop laser scanner for production of digital cast, using 3 shape ortho analyser Software®, the tray will be designed Fabrication and printing of the digital tray Using Dent1 3D printer® (Mogassam®, Greek campus, Cairo, Egypt), the tray will be printed Clinical application of the digital tray
- Teeth to be bonded are polished and etched.
- Teeth isolation \& moisture control are achieved.
- Dead Soft Stainless Steel wire is placed and adapted in its place in the digital tray.
- Placement of the tray in the patient mouth on the prepared teeth
- Adhesive bond is applied to teeth and then curing of the adhesive bonding.
- 3M ® composite (3M Unitek company , Monrovia, California, USA) is placed in the printed tray holes and any excess composite will be removed and then light curing is done.
- Time will be recorded during this step
Removal of digital tray After insuring complete curing of the composite the digital tray is then removed from patient mouth, Bond failure of composite pads will be checked in this step and recorded.
Control Group All patients of this group will follow conventional steps of direct bonding procedure of fixed mandibular retainer
- Pumice and polish the lingual surface of teeth on which retainer is to be bonded
- The retainer wire is prefabricated by incorporating perpendicular pieces of 1.5"-2" ligature wire at interdental region of respective teeth
- The retainer wire is then adapted on the tooth surface. The short ligatures are passed interdentally one occlusal to contact point and other gingival to contact point and tied over.
- Bonding procedure after etching and application of sealant is carried out.
- Enough adhesive should be used. Light curing is done.
- 3M ® composite (3M Unitek company, Monrovia, California, USA) is placed then light curing is done.
- Cut the ligature wires and pull them laically to disengage.
- Time will be recorded during this step
- Sample Size calculation: the sample is increased to a total size of 20 participants; 10 in each arm.
- Recruitment strategy:
- Patients will be selected from the outpatient clinic of the orthodontic Department - Cairo University
- Consecutive sampling is done through screening of patients. This will continue until the target population is achieved.
- Identifying and recruiting potential subjects is achieved through patient database.
II. Assignment of Interventions
- Sequence generation:
It will be performed as 1:1 allocation. The sequence of the two groups will be done by computer generated random numbers. This will be done by using Microsoft Office Excel 2013 sheet
- Allocation Concealment:
Random numbers obtained by random sequence generation will be written on white papers, each paper will be kept in sealed envelope. Sealed envelopes will be kept in box at the secretary of orthodontic department office.
- Implementation:
Implementation will be carried out in the secretary of the orthodontic department at the Faculty of Oral and Dental Medicine, Cairo University.
- Blinding:
Participants Patients can detect the transfer tray so blinding is not possible Operator The main operator is responsible for the bonding so the blinding is not possible Assessor The assessor (different from main operator will carry out the measurement blindly
Study design
- Primary purpose
- Other
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (outcomes assessor)
- Number of arms
- 2
- Model description
- all patient will receive a modified indirect technique for bonding fixed mandibular retainer and the key of modification is the fabrication of 3D printed digital positioning tray for placement of retainer with holes for composite pads for its direct application using 3 shape Ortho analyser Software ® instead of conventional indirect retainer fabrication method
| Arm | Type | Receives |
|---|---|---|
| Treatment Group | Active comparator | Device: 3d printed positioning trayAfter finishing orthodontic treatment, all patient will receive a modified indirect technique for bonding fixed mandibular retainer and the key of modification is the fabrication of 3D printed digital positioning tray for placement of retainer with holes for composite pads for its direct application using 3 shape Ortho analyser Software ® instead of conventional indirect retainer fabrication method |
| Control Group | No intervention | –All patients of this group will follow conventional steps of direct bonding procedure of fixed mandibular retainer |
Who may qualify
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Child, Adult, Older adult
Key inclusion criteria (4 listed)
- • Patients with properly finished orthodontic treatment according to ABO standards.
Key exclusion criteria (4 listed)
- • Patients with no need of fixed bonded mandibular retainer
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| 3d printed positioning tray3d printed positioning tray for lingual fixed retainer placement in treatment group | Device | Treatment Group |
Primary outcome
chairside time
Time frame: follow up up to 6 month
chairside time for bonding fixed lingual mandibular retainer using stopwatch in measured seconds
1 secondary outcome
bond failure
Time frame: 6 month follow up
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 5 Sep 2021.
- Individual participant dataSharing planned: No
Related trials for Orthodontic Appliance Complication
Recruiting
Bacterial Diversity Study Using 16S rRNA Sequencing of Periodontal Samples From Patients With Orthodontic Retainers
Fixed Orthodontic Retainer, Orthodontic Appliances, Removable
Recruiting
Comparison of MI Paste Plus and Resin Infiltration in White Spot Lesions Following Orthodontic Treatment
White Spot Lesions, Orthodontic Appliance Complication
Recruiting
The Effect of Intraoral Transcutaneous Electrical Nerve Stimulation in Orthodontics Pain
Orthodontic Appliance, Pain
Not yet recruiting
Comparison of a 3-step Bonding System (Transbond™ XT) and a 2-step System (GC Ortho Connect™) on Demineralization Around Maxillary Orthodontic Brackets
Tooth Demineralization, White Spot Lesion
Recruiting
Microbial Adherence, Surface Roughness, Effectiveness and Impact on Patients Between Conventional and 3D Printed Twin Block Appliances
Orthodontic Appliances, Removable, Orthodontic Appliance Complication
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing 3d printed positioning tray in people with Orthodontic Appliance Complication, run by Raghda Alaa at 1 site in Egypt.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 5 Sep 2021. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Egypt. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
chairside time (time frame: follow up up to 6 month). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 5 Sep 2021; AzTrials last refreshed its copy on 30 Oct 2026.