AzTrials
AzTrials

Musculoskeletal PainNCT03573219

A New Experimental Model of Transient and Short-lasting Muscle Pain in Humans Based on Diathermy

A study testing Short-wave diathermy in people with Musculoskeletal Pain and Musculoskeletal Injury, run by National Council of Scientific and Technical Research, Argentina at 1 site in Argentina.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This study evaluates the use of short-wave diathermy (SWD) as an novel experimental model to induce transient and intensity-controlled muscle pain by heating muscle tissue. Read more about this study

Who is it for?
Ages 18 to 60 yearsHealthy volunteers can take part
Conditions the study is for
Musculoskeletal Pain, Musculoskeletal Injury
What is being tested?
Short-wave diathermy
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
19 participants
Where
1 siteArgentina
Study dates
19 Feb 2018to 29 Aug 2018
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 60 years
  • All sexes
  • Healthy volunteers accepted
  • Adult

Who may be able to join

  • Understanding of the content and scope of the experiment, and compliance with the experiment's instructions.
  • To have signed the informed consent.

Who cannot join

  • Pregnancy.
  • Previous history of neurological or musculoskeletal disorders or chronic pain.
  • Previous history of addictive behavior, defined as abuse of alcohol, cannabis, opioids or other drugs.
  • Previous history of thermosensitivity disorders.
  • Previous history of mental illness.
  • Presence of fever, tuberculosis, tumors, infectious processes, or acute inflammatory processes.
  • Implantation of peacemaker or metallic prosthesis.
  • Use of analgesics within 24 h prior to the experiment.

Trial locations and contacts

1 site in 1 country.

Argentina1 site
  • Facultad de Ingeniería - Universidad Nacional de Entre Ríos (Argentina)

    Oro Verde, Entre Ríos Province, 3100

Other trials in Argentina

About this study

Official title: A New Experimental Model of Acute Muscle Pain in Humans Based on Short-wave Diathermy

This study evaluates the use of short-wave diathermy (SWD) as an novel experimental model to induce transient and intensity-controlled muscle pain by heating muscle tissue.

Read the detailed description

Application of short-wave diathermy All researchers, students and postdocs involved in experimental application of SWD will be properly trained by the Non-Ionizing Radiation Research Group of the National University of Entre Ríos. The application of SWD will be carried out by a CEC M-8 short-wave thermotherapy unit (CEC Electrónica, Córdoba, Argentina). The device has capacitive applicators, that will be situated around the muscle to be irradiated on top of a cotton towel, in order to absorb perspiration and avoid undesired heating effects. Afterwards the emission mode (continuous or pulsed) will be selected, and application of SWD will start. The intensity of SWD will be gradually increased until the volunteer perceives a warm sensation, and once familiarized with this perception, the intensity will be increased until a sensation of constant but tolerable pain is evoked. This sensation will be maintained throughout the duration of the SWD application, estimated in approximately 10 minutes. In case the volunteer feels excessive discomfort or does not adequately tolerate the application of SWD, the device will be turned off immediately and the experimental session will finish.

Experimental pain model assessment

  • Model direct effects: maximum and average pain ratings will be assessed through a Visual Analog Scale (VAS). The VAS ranges from 0 to 10, where 0 represents no perception, 3 represents the pain threshold (i.e. the minimum irradiation intensity that elicits pain) and 10 represents the tolerance threshold (i.e. the irradiation intensity that elicits an intolerable pain sensation). Duration of pain will also be recorded, in case the experiment has to be interrupted before SWD application is completed and to assess potential cases in which pain outlasts SWD application. Furthermore, delivered RF power will be measured using a Bird 43 RF wattmeter (Bird Technologies, OH, USA).
  • Pressure stimulation: pressure stimulation will be applied through a Somedic algometer (Somedic SenseLab AB, Sweden), directly over the muscle being examined, using a 1 cm2 round tip. Pressure will be gradually increased from 0 kPA until a maximum of 1000 kPa at a rate of approximately 30 kPa/s. Pressure pain threshold (PPT) will be defined as the force at which the pressure sensation becomes painful. Pressure tolerance threshold (PTT) will be defined as the force at which pressure sensation becomes intolerable. If any of the threshold are not reached until the pressure is increased to 1000 kPa, the this value will be considered as the corresponding threshold.
  • Pinprick and tactile stimulation: pinprick stimuli will be applied on the skin over the muscle being examined using a set of pinprick stimulators, consisting on a needle with a 0.25 mm tip linked to calibrated weights, ranging from 1 g to 50 g, in order to apply forces between 8 and 500 mN approximately. Dynamic tactile stimulation will be applied by stroking a cotton tip over the skin. Pinprick sensitivity (PS) and dynamic tactile sensitivity (DTS) will be quantified using the VAS described above.
  • Electrical stimulation: electrical stimuli will be applied to the skin over the muscle being examined using a concentric electrode, in which the cathode is made of 16 stainless steel blunt pins with 0.2 mm diameter tips and 1 mm length, and the anode is a concentric stainless steel ring of 20 mm diameter. The electrical stimulus will consist on a rectangular pulse of 1 ms duration, generated by a Biopac STMISOLA constant-current electrical stimulator (Biopac Systems Inc., California, USA). Stimulation intensity will be increased from 1 mA in steps of 0.5 mA until a pain sensation is evoked. This intensity will be defined as the electrical pain threshold (EPT). Once the EPT is determined, repeated stimulation will be applied referenced to this intensity in order to record somatosensory evoked potentials (SEPs) through surface electroencephalography (EEG).
  • Motor responses: motor responses will be recorded from upper and lower limbs. For the upper limb, two sets of experimental motor tasks are planned, and the overall aim is to measure changes in precision in the execution of the motor tasks due to pain. The first one will be a simple task, basically consisting on the use of a joystick to move a cursor to a two-dimensional moving target displayed in a computer screen. Specific details of the implementation of the optimal setup for this motor task and the required software will be provided by collaborators from the Physiology of Action Lab at Universidad de Buenos Aires. The second motor task will involve more complex movements and haptic feedback, provided by a Phantom Omni haptic device (SensAble Technologies, Inc., Massachusetts, USA). The haptic device can provide controlled levels of force feedback (up to 3.3 N) and a precise mapping of the trajectories employed in the motor task in three dimensions (resolution: 0.055 mm). Specific details of the implementation of the optimal setup for this motor task and the required software will be provided by collaborators from the Robotics Research Group at National University of Entre Ríos. For the lower limb, the motor task will consist on a balance task performed over high-resolution pressure sensing platform that will be able to record differences in weight loading between left and right leg and variations in the center of pressure (CoP). The platform is a recent technological development from the Electronic Prototyping and 3D Printing Lab at the Faculty of Engineering of National University of Entre Ríos, and it has a sensing area of 430 x 320 mm, with a resolution of 4 pressure sensors per cm2 and a measurement range from 1 to 785 kPa.
  • Brain responses: EEG will be recorded using a Neuroscan SynAmps amplifier (Compumedics Ltd., Victoria, Australia) during the planning and execution of motor tasks, in order to evaluate changes in movement-related cortical potentials (MRCP) in relation to SWD-induced pain (Jochumsen et al. 2015). Additionally, resting-state EEG will be recorded before, during and after SWD application, in order to assess potential changes in functional connectivity (FC) (Mayhew et al. 2013). FC analysis will be performed by collaborators from CNAP at Aalborg University.

Sample size considerations

The experimental design is an interventional, pre-post study design (Thiese 2014), in which each participant acts as his own control. Sample size calculation will be performed taking into account the expected effect size that the model will have on the primary outcome (PPT). Several experiments have shown that PPT in the wrist extensor/flexor muscles (e.g. extensor carpi radialis longus) is around 350 ± 150 kPa (mean ± standard deviation), whereas PPT for the ankle dorsiflexor muscles (e.g. tibialis anterior) is around 600 ± 250 kPa (Fischer 1987; Delfa de la Morena et al. 2013). On the other hand, there is no existing information on the expected size of the difference in PPT due to the application of SWD, so this value will be approximated taking into account reference values of differences in PPT generated by other experimental models of pain, such as the injection of hypertonic saline solution or delayed onset muscle soreness. In these cases, PPT is usually reduced between 10 and 30% during the effects of the model, so an average of 20% difference will be considered in order to calculate the sample size for these experiments. Considering a probability of making a type I error (α) of 5%, a statistical power (1 - β) of 80%, and an estimated correlation between measures of 0.8, the sample size required to detect the aforementioned difference is 16 volunteers for the experiment in the upper limb and 17 volunteers for the experiment in the lower limb. In order to account for an unexpectedly larger variation, 20 subjects are expected to be recruited for each experiment.

Being tested
Short-wave diathermy
Keywords
Short-Wave Diathermy, Transient muscle pain, Non-invasive pain model
Medical subject headings
Musculoskeletal Pain

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Short-wave diathermyRadiation

    The application of SWD will be carried out by a CEC M-8 short-wave thermotherapy unit. The device has capacitive applicators, that will be situated around the muscle to be irradiated on top of a cotton towel, in order to absorb perspiration and avoid undesired heating effects. Afterwards the emission mode (continuous or pulsed) will be selected, and application of SWD will start. The intensity of SWD will be gradually increased until the volunteer perceives a warm sensation, and once familiarized with this perception, the intensity will be increased until a sensation of constant but tolerable pain is evoked. This sensation will be maintained throughout the duration of the SWD application, estimated in approximately 10 minutes.

Study groups in NCT03573219
Study groupRoleWhat they receive
Healthy participantExperimentalHealthy volunteers that fulfill the inclusion criteria. Intervention: Short-wave diathermy (Radiation)
Receives: Radiation: Short-wave diathermy

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Pressure pain threshold (PPT)

    Change in the pressure pain threshold (kPa) recorded after the induced of muscle pain using SWD on the established time point records.

    Measured: 0 to 1 hour

Secondary outcomes (11)
  1. Assessment of changes in pain intensity in direct relation to the experimental model

    Maximum and average pain ratings (0 to 100 score).

    Measured: 0 to 1 hour

  2. Assessment of changes in pain time course in direct relation to the experimental model

    Duration of pain (seconds)

    Measured: 0 to 1 hour

  3. Assessment of changes in functional connectivity in direct relation to the experimental model

    Changes in functional connectivity (FC), assessed through surface electroencephalography (EEG).

    Measured: 0 to 1 hour

  4. Assessment of changes in Pinprick sensitivity

    Pinprick sensitivity (PS) (0 to 100 score).

    Measured: 0 to 1 hour

  5. Assessment of changes in Dynamic tactile sensitivity

    Dynamic tactile sensitivity (DTS) (0 to 100 score).

    Measured: 0 to 1 hour

  6. Assessment of changes in Electrical pain threshold

    Electrical pain threshold (EPT) (mA).

    Measured: 0 to 1 hour

  7. Assessment of changes in Somatosensory evoked potentials

    Somatosensory evoked potentials in response to electrical stimuli (SEP), assessed through EEG. (mV)

    Measured: 0 to 1 hour

  8. Assessment of changes in Movement-related cortical potentials

    Change in Movement-related cortical potentials (MRCP), assessed through EEG.

    Measured: 0 to 1 hour

  9. Assessment of changes in motor responses for upper limb

    Change in precision during motor execution (percentage)

    Measured: 0 to 1 hour

  10. Assessment of changes in motor responses for lower limb

    Change in balance (Centre of pressure)

    Measured: 0 to 1 hour

  11. Assessment of changes in weight loading

    Measured in Kg

    Measured: 0 to 1 hour

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted29 Jun 2018
  2. Study start19 Feb 2018
  3. Primary completion29 Aug 2018
  4. Study completion29 Aug 2018

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Basic science
Allocation
Not applicable
Intervention model
Single group
Model description
The SWD applicators will be placed in the desired position, around the forearm for the upper limb experiments, or below the knee for the lower limb experiments. The distance between applicators will be adjusted until the desired pain sensation is obtained according to the subjective criterion of the volunteer. This sensation should be mild or moderate pain, but tolerable for the duration of the application. Once the first application is completed, the volunteer will be allowed to rest for a period of 10 minutes, and the assessment will be repeated to test for possible after effects. After it is verified that the muscles recovered their normal temperature and the pain sensation has completely disappeared, the variables related to changes in motor responses under rest conditions will be recorded. Then SWD will be applied a second time using the same parameters as in the first application. Once the registration is complete, the experiment will be finished.
Masking
None (open label)
Enrolment
19 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03573219
Sponsor's protocol ID
IS001890
Status last verified
Aug 2018
First submitted
5 Jun 2018
Last updated
31 Aug 2018
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Yes: De-identified individual participant data for primary and secondary outcome measures will be made available.

Publications

  • Goats GC. Continuous short-wave (radio-frequency) diathermy. Br J Sports Med. 1989 Jun;23(2):123-7. doi: 10.1136/bjsm.23.2.123.

    PubMed 2691003
  • Graven-Nielsen T. Fundamentals of muscle pain, referred pain, and deep tissue hyperalgesia. Scand J Rheumatol Suppl. 2006;122:1-43. doi: 10.1080/03009740600865980. No abstract available.

    PubMed 16997767
  • Neziri AY, Scaramozzino P, Andersen OK, Dickenson AH, Arendt-Nielsen L, Curatolo M. Reference values of mechanical and thermal pain tests in a pain-free population. Eur J Pain. 2011 Apr;15(4):376-83. doi: 10.1016/j.ejpain.2010.08.011. Epub 2010 Oct 6.

    PubMed 20932788
  • Vuilleumier PH, Biurrun Manresa JA, Ghamri Y, Mlekusch S, Siegenthaler A, Arendt-Nielsen L, Curatolo M. Reliability of Quantitative Sensory Tests in a Low Back Pain Population. Reg Anesth Pain Med. 2015 Nov-Dec;40(6):665-73. doi: 10.1097/AAP.0000000000000289.

    PubMed 26222349

Questions about this trial

What is this clinical trial studying?

A study testing Short-wave diathermy in people with Musculoskeletal Pain and Musculoskeletal Injury, run by National Council of Scientific and Technical Research, Argentina at 1 site in Argentina.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 31 Aug 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Argentina. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Pressure pain threshold (PPT) (time frame: 0 to 1 hour). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03573219, which also lists 4 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 31 Aug 2018.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in