Trial summary

The study is aimed to evaluate the sensitivity, specificity, positive predictive value, negative predictive value and accuracy rate of endobronchial ultrasound (EBUS) image features in diagnosing peripheral pulmonary lesions (PPLs). Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Endobronchial Ultrasound
What is being tested?
EBUS
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
200 participants
Where
No sites listed yet
Study dates
Jul 2018to Dec 2019
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients who are older than 18 year-old.
  • Chest CT shows PPLs suspected to be malignant that need to be confirmed by pathology. The lesion is surrounded by lung parenchyma and invisible in standard bronchoscopy.
  • Patients who agree to undergo bronchoscopy without any contraindications.
  • Patients who have good compliance and sign informed consent.

Who cannot join

  • Absence of bronchus leading to or adjacent to the lesion from CT scan.
  • Refusal of participation.
  • Severe cardiopulmonary dysfunction and other indications that can't receive bronchoscopy.
  • Presence of concomitant endobronchial lesion during the bronchoscopy procedure

Trial locations and contacts

No sites are listed yet.

About this study

Official title: Endobronchial Ultrasound Image Features in the Diagnosis of Peripheral Pulmonary Lesions

The study is aimed to evaluate the sensitivity, specificity, positive predictive value, negative predictive value and accuracy rate of endobronchial ultrasound (EBUS) image features in diagnosing peripheral pulmonary lesions (PPLs).

Read the detailed description

The study is designed as a single center prospective trial. The participating center is Department of Ultrasound, Shanghai chest Hospital, Shanghai Jiao Tong University, China. The study is expected to enroll 200 patients. The investigator evaluates the sensitivity, specificity, positive predictive value, negative predictive value and accuracy rate of EBUS image features in diagnosing PPLs. EBUS is performed using an endoscope ultrasound system, which is equipped with a 20-MHz mechanical radial-type probe (UM-S20-17S;Olympus) with an external diameter of 1.4 mm.

Being tested
EBUS
Keywords
endobronchial ultrasound, peripheral pulmonary lesions, image features

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • EBUSDevice

    EBUS is performed using an endoscope ultrasound system , which is equipped with a 20-MHz mechanical radial-type probe (UM-S20-17S;Olympus) with an external diameter of 1.4 mm and a GS (K-201; Olympus).

Study groups in NCT03575715
Study groupRoleWhat they receive
EBUS groupExperimentalEBUS and guide sheath (GS) are inserted into bronchi in the assistance of navigation bronchoscopy. The EBUS probe and GS are confirmed to reach the lesion by EBUS images, cytologic and pathologic specimens are obtained with or without fluoroscopic guidance.
Receives: Device: EBUS

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. The diagnostic value of EBUS image features

    The diagnostic value includes sensitivity, specificity, positive predictive value, negative predictive value and accuracy rate.

    Measured: one year

Secondary outcomes (1)
  1. EBUS image features of adenocarcinoma

    Making invasive EBUS image features of adenocarcinoma and non-invasive adenocarcinoma

    Measured: one year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted2 Jul 2018
  2. Study startJul 2018 (estimated)
  3. Primary completionDec 2019 (estimated)
  4. Study completionDec 2019 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
200 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03575715
Sponsor's protocol ID
Chest007
Status last verified
Jun 2018
First submitted
21 Jun 2018
Last updated
2 Jul 2018
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Chao TY, Lie CH, Chung YH, Wang JL, Wang YH, Lin MC. Differentiating peripheral pulmonary lesions based on images of endobronchial ultrasonography. Chest. 2006 Oct;130(4):1191-7. doi: 10.1378/chest.130.4.1191.

    PubMed 17035455
  • Izumo T, Sasada S, Chavez C, Matsumoto Y, Tsuchida T. Radial endobronchial ultrasound images for ground-glass opacity pulmonary lesions. Eur Respir J. 2015 Jun;45(6):1661-8. doi: 10.1183/09031936.00167914. Epub 2015 Jan 8.

    PubMed 25573408
  • Kurimoto N, Murayama M, Yoshioka S, Nishisaka T. Analysis of the internal structure of peripheral pulmonary lesions using endobronchial ultrasonography. Chest. 2002 Dec;122(6):1887-94. doi: 10.1378/chest.122.6.1887.

    PubMed 12475821
  • Yasufuku K. Current clinical applications of endobronchial ultrasound. Expert Rev Respir Med. 2010 Aug;4(4):491-8. doi: 10.1586/ers.10.39.

    PubMed 20658910
  • Travis WD, Rekhtman N, Riley GJ, Geisinger KR, Asamura H, Brambilla E, Garg K, Hirsch FR, Noguchi M, Powell CA, Rusch VW, Scagliotti G, Yatabe Y. Pathologic diagnosis of advanced lung cancer based on small biopsies and cytology: a paradigm shift. J Thorac Oncol. 2010 Apr;5(4):411-4. doi: 10.1097/JTO.0b013e3181d57f6e. No abstract available.

    PubMed 20357614

Questions about this trial

What is this clinical trial studying?

A study testing EBUS in people with Endobronchial Ultrasound, run by Shanghai Chest Hospital.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 2 Jul 2018. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Lei Wang, MD (86-021-22200000 ext. 1416, 13917985547@163.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

The diagnostic value of EBUS image features (time frame: one year). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03575715, which also lists 5 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 2 Jul 2018.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in