AzTrials
AzTrials

Metal AllergyRESTALLNCT03588962

Metal Allergy In-Stent Restenosis Study

A study testing In-stent restenosis in people with Metal Allergy and Contact Allergy, run by Silesian Centre for Heart Diseases.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

In-stent restenosis remains one of the most challenging problems in patients after coronary artery angioplasty. Angiographically, it is discovered in 10% of the patients after drug-eluting stent (DES) implantation. Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
In-stent restenosis
Could I receive a placebo?
Yes, some participants may receive a placebo
How many people
1,000 participants
Where
No sites listed yet
Study dates
1 Oct 2018to 31 Dec 2020
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • angiographically proven in-stent restenosis after technically correct implantation
  • technically correctly implanted stent

Who cannot join

  • autoimmune diseases (e.g., rheumatoid arthritis)
  • immunodeficiency syndromes (e.g., HIV infection)
  • chronic use of immunosuppressive drugs and/or corticosteroids
  • skin lesions that may attenuate the reading of skin tests
  • previous coronary artery bypass surgery (in subgroup 1) or planned coronary artery bypass surgery (in subgroup 2)
  • any surgical procedure with metal implants (in the past or planned within 12 months of observation)

About this study

Official title: RESTenosis in Patients With Contact ALLergy to Metals Zabrze Study

In-stent restenosis remains one of the most challenging problems in patients after coronary artery angioplasty. Angiographically, it is discovered in 10% of the patients after drug-eluting stent (DES) implantation. There are multiple factors causing restenosis, which can be divided into two major groups: first vessel-dependent (based on the vessel's tortuosity, dimensions and lesion's calcification, all leading to suboptimal stent expansion), and second dependent on the inflammatory processes caused by the intervention. Study objectives is the analysis of the possible correlation between allergy to metals utilised during the stent manufacturing (nickel, cobalt, chromium, molybdenum, tungsten) and in-stent restenosis occurence. The angiographic results of stent implantation, and in-stent restenosis will be assessed independently by two skilled interventional cardiologists, and in case of their discrepant opinions, the decision will be made on the basis of the third cardiologist. The tests will be applicated during the hospitalisation, then read after 48 hours and 72 hours, and subsequently interpreted by the skilled dermatologist, during the hospital stay or afterwards.

Read the detailed description

Introduction:

In-stent restenosis remains one of the most challenging problems in patients after coronary artery angioplasty. Angiographically, it is discovered in 10% of the patients after drug-eluting stent (DES) implantation. There are multiple factors causing restenosis, which can be divided into two major groups: first vessel-dependent (based on the vessel's tortuosity, dimensions and lesion's calcification, all leading to suboptimal stent expansion), and second dependent on the inflammatory processes caused by the intervention. Although the proper stent expansion depends mostly on the cardiologist's manual dexterity, the inflammation development does totally not depend on the operator. The allergic reactions to metals are likely to be one of the underlying causes of inflammation. Among the most prevalent allergens, cobalt, chromium, nickel, and tungsten used as the stent materials are causing the most intensive contact allergic reaction. The allergic process induced by the aforementioned metals belongs to type IV contact allergy (T-cell mediated). Stent implantation results in life-long contact with metal, thus in allergic patients, it is likely to develop local reactions leading to in-stent restenosis. Up to date, there have been approximately one thousand in-stent restenosis cases documented in patients with confirmed contact allergy to stent metals.

Study objectives:

Analysis of the possible correlation between allergy to metals utilised during the stent manufacturing (nickel, cobalt, chromium, molybdenum, tungsten) and in-stent restenosis occurence.

Materials and methods:

The study will consist of two arms:

First arm: Patch tests for the metals used in stent production will be applicated in the patients with angiographically proven in-stent restenosis developed after technically correct implantation.

Second arm: In patients with (technically correctly) implanted stent, patch tests will be applicated to identify cases with contact allergy. The patients will then be monitored for a 6-12 months follow-up period in purpose of evaluating the dependance between in-stent restenosis and contact allergy.

The angiographic results of stent implantation, and in-stent restenosis will be assessed independently by two skilled interventional cardiologists, and in case of their discrepant opinions, the decision will be made on the basis of the third cardiologist.

The tests will be applicated during the hospitalisation, then read after 48 hours and 72 hours, and subsequently interpreted by the skilled dermatologist, during the hospital stay or afterwards.

Being tested
In-stent restenosis
Keywords
allergy to metals, restenosis, in-stent restenosis, coronary artery disease
Medical subject headings
Dermatitis, Allergic Contact, Coronary Restenosis, Coronary Artery Disease

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • In-stent restenosisBiological

    Patch tests for the metals applicated in each of the patients

Study groups in NCT03588962
Study groupRoleWhat they receive
Metal allergy driven restenosisExperimentalPatients with angiographically proven in-stent restenosis developed after technically correct implantation. Patch tests for the metals used in stent production will be applicated. The tests will be applicated during the hospitalisation, then read after 48 hours and 72 hours, and subsequently interpreted by the skilled dermatologist, during the hospital stay or afterwards. Possible correlation between allergy to metals utilised during the stent manufacturing (nickel, cobalt, chromium, molybdenum, tungsten) and in-stent restenosis occurence.
Receives: Biological: In-stent restenosis
Looking for allergic restenosisPlacebo comparatorPatients with (technically correctly) implanted stent. Patch tests will be applicated to identify cases with contact allergy. The tests will be applicated during the hospitalisation, then read after 48 hours and 72 hours, and subsequently interpreted by the skilled dermatologist, during the hospital stay or afterwards.The patients will then be monitored for a 12 months follow-up period in purpose of evaluating the dependance between in-stent restenosis and contact allergy. Possible correlation between allergy to metals utilised during the stent manufacturing (nickel, cobalt, chromium, molybdenum, tungsten) and in-stent restenosis occurence.
Receives: Biological: In-stent restenosis

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Major Adverse Cardiovascular Events (MACE)

    In-stent restenosis, acute myocardial infarction (AMI), death, cardiovascular (CV) death

    Measured: 12 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted17 Jul 2018
  2. Study start1 Oct 2018 (estimated)
  3. Primary completion1 Apr 2019 (estimated)
  4. Study completion31 Dec 2020 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Prevention
Allocation
Non-randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
1,000 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03588962
Sponsor's protocol ID
RESTALL Zabrze Study
Acronym
RESTALL
Status last verified
Jul 2018
First submitted
18 Mar 2018
Last updated
17 Jul 2018
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing In-stent restenosis in people with Metal Allergy and Contact Allergy, run by Silesian Centre for Heart Diseases.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 17 Jul 2018. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. Some participants in this study may receive a placebo. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Major Adverse Cardiovascular Events (MACE) (time frame: 12 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Jul 2018.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in