Functional Mitral RegurgitationNCT03616678
VenTouch OUS Feasibility Study
A study testing VenTouch System in people with Functional Mitral Regurgitation, run by Mardil Medical at 12 sites in 7 countries.
Trial summary
This is a prospective, multi-center, single-arm study to evaluate safety and efficacy of the VenTouch System for treatment of subjects with functional MR. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Functional Mitral Regurgitation
- What is being tested?
- VenTouch System
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 15 participants
- Where
- 12 sitesin 7 countries
- Study dates
- 25 Mar 2019to 31 Dec 2023
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Adults ≥18 years of age
- Symptomatic FMR of grade moderately severe to severe (3 to 4) due to either ischemic or non-ischemic dilated cardiomyopathy with structurally normal leaflets determined by echocardiography (preferably with echocardiographic evidence of EROA ≥ 0.20 cm2)
- NYHA Class II to IV
- Left Ventricular Ejection Fraction (LVEF) 20%-50% determined by echocardiography
- Treatment and compliance with optimal guideline-directed medical therapy for heart failure for at least 30 days
- Subjects with a Class I indication for CRT implant according to current guidelines should have CRT implant prior to entry into the study. Subjects who have existing CRT implants may be included in the study if the implant has been in place for at least 90 days; reprogramming of an implanted CRT that results in increased biventricular pacing (from <92% to ≥92%) must be in place for at least 30 days.
Show all 11Show fewer
- Left Ventricular End Diastolic Diameter (LVEDD) of 55 to 80 mm as determined by echocardiography
- Indexed Left Ventricular End Diastolic Diameter (LVEDDi) of 30 to 40 mm/m2 (where LVEDDi is calculated by LVEDD/Body Surface Area (BSA))
- Subject is willing and available to return for study follow-up
- Subject or legal representative understands and provides signed informed consent for participation in study
- Acceptance of subject for trial enrollment after review of all subject baseline data by Study Selection Committee
Who cannot join
- Life expectancy of less than 12 months due to conditions other than cardiac status
- Anticipated need for LVAD or transplant within 12 months
- Chronic Obstructive Pulmonary Disease (COPD) requiring continuous home oxygen therapy or chronic outpatient oral steroid use
- American College of Cardiology / American Heart Association (ACC/AHA) Stage D heart failure
- Six-minute walk distance < 150 meters
- Identified need for any cardiovascular surgery
Show all 29Show fewer
- STS score that suggests prohibitive surgical risk as determined by Subject Selection Committee
- Untreated clinically significant coronary artery disease
- Any procedure, condition or cardiac anatomy that may impact or compromise the pericardial space (e.g. prior mitral valve surgery, CABG, epicardial pacing leads, pericarditis, or other procedure involving pericardial access)
- Percutaneous coronary intervention, acute coronary syndrome (e.g. STEMI or non-STEMI myocardial infarction, unstable angina) or clinically significant cardiac events (e.g. hypotension, syncope, arrhythmias, embolism, heart failure exacerbation or any hospitalization) within 30 days of enrollment
- Thoracic or cardiac surgery contraindication (e.g., acute respiratory distress, endocarditis, myocarditis, pericarditis)
- Significant structural abnormality of the mitral valve (e.g. flail leaflets, ruptured or elongated chordae, prolapsed valve, perforated valve leaflets, significant calcification in the annulus, or calcification in the leaflets that restricts motion)
- Severe symptomatic carotid stenosis
- Severe or sustained pulmonary hypertension, defined by resting pulmonary artery systolic (PAS) pressure ≥70 mmHg determined by echocardiography or right heart catheterization
- Physical evidence of right-sided congestive heart failure with echocardiographic evidence of moderate or severe right ventricular dysfunction or moderate to severe TR
- Hypotension (systolic pressure <90 mmHg)
- Hemodynamic instability requiring inotropic support or mechanical heart assistance within 30 days
- Hypertrophic cardiomyopathy, restrictive cardiomyopathy, or any other structural heart disease causing heart failure other than dilated cardiomyopathy
- UNOS status 1 heart transplantation
- Creatinine > 2.5 mg/dL (221 µmol/L) and/or renal failure requiring dialysis
- Stroke (cerebrovascular accident) or transient ischemic event (TIA) within 30 days of enrollment
- Active systemic infection or bleeding
- Autoimmune disorders and/or the use of immune suppression therapy
- Females who are pregnant (as documented by HCG beta pregnancy test in females of child-bearing age) or lactating
- Currently enrolled in another investigational drug or device study
- Intra-Operative Exclusion Criteria:
- Significant structural abnormality of the mitral valve (e.g. flail leaflets, ruptured or elongated chordae, prolapsed valve, perforated valve leaflets, significant calcification in the annulus, or calcification in the leaflets that restricts motion)
- Signs/indications of ischemia
- Intra-operative coronary angiography demonstrates that there is compression of the coronary arteries or reduction in coronary blood flow due to the VenTouch implant
Trial locations and contacts
12 sites in 7 countries.
12 sites in 7 countries
Canada6 sites, 6 recruiting
- Not yet recruiting
Libin Cardiovascular Institute, University of Calgary
Calgary, Alberta, T2N 4N1
William Kent, MD, 403-944-5480, william.kent@albertahealthservices.ca
William Kent, MD
- Not yet recruiting
London Health Sciences Centre, University Hospital
London, Ontario, N6A 5A5
Stephanie Fox, BA, RRT, 519-685-8500 ext. 35031, Stephanie.Fox@lhsc.on.ca
Dave Nagpal, MD
- Recruiting
Montreal Heart Institute
Montreal, Quebec, H1T 1C8
Manon Vervais, 514-376-3330 ext. 3783, manon.vervais@icm-mhi.org
Anita Asgar, MD
- Recruiting
Institut Universitaire de Cardiologie et de Pneumologie De Québec (IUCPQ)
Québec, Quebec, G1V4G5
Hugo Tremblay, 418-656-8711 ext. 3797, hugo.tremblay@criucpq.ulaval.ca
François Dagenais, MD
- Recruiting
Toronto General Hospital
Toronto, Ontario, 4NU-470
Shakira Christie, Shakira.Christie@uhn.ca
Vivek Rao, MD, PhD
- Not yet recruiting
University of British Columbia, St. Paul's Hospital
Vancouver, British Columbia, V6Z 1Y6
Catherin Mok, 604-806-8383, CMok@providencehealth.bc.ca
Anson Cheung, MD
France1 site
- Withdrawn
Bordeaux Heart University Hospital
Bordeaux, Pessac, 33604
Hungary1 site, 1 recruiting
- Recruiting
Semmelweis University Heart and Vascular Center
Budapest
Orsolya Kemenes, +36 20 8250511, studycenter.sekk@gmail.com
Béla Merkely, MD, PhD
Netherlands1 site
- Withdrawn
Leiden University Medical Center
Leiden, 2300 RC
Panama1 site, 1 recruiting
- Recruiting
Pacifica Salud Hospital Punta Pacifica
Panama City, 0801
Margelis Muñoz, (507) 6499-9304, margelismunoz@gmail.com
Christian Marin y Kall, 305-799-1435, marinykallch@hotmail.com
Poland1 site
- Withdrawn
Centralny Szpital Kliniczny MSWiA w Warszawia
Warsaw, 02-507
About this study
Official title: Evaluation of The Minimally Invasive VenTouch™ System in The Treatment of Functional Mitral Valve Regurgitation (FMR): OUS Feasibility Study
This is a prospective, multi-center, single-arm study to evaluate safety and efficacy of the VenTouch System for treatment of subjects with functional MR.
Read the detailed description
This is a prospective, multi-center, single-arm study to evaluate safety and efficacy of the VenTouch System for treatment of subjects with functional MR enrolling up to 15 subjects who have been diagnosed with Grade 3-4 functional mitral valve regurgitation and deemed eligible per assessment by the inclusion/exclusion criteria. The duration of the study follow-up is 36 months from the time of therapy adjustment. Data from this trial may be utilized in support of a CE study in Europe and/or a pilot IDE study in the U.S. Follow-up testing will be performed at 1, 3, 6, 12, 24, and 36 months post-therapy adjustment.
- Conditions
- Functional Mitral Regurgitation
- Being tested
- VenTouch System
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
VenTouch SystemDevice
The VenTouch™ System consists of a delivery tool with a pre-loaded implant (VenTouch device) and accessories, which include a sizing tool, PEMS, chamber positioning tool, and accessories kit with luer fitting, tubing clamp, and titanium plug. The VenTouch device is offered in 6 sizes, with 4 different sized inflatable chambers available. Please refer to the VenTouch Instructions for Use for and system details.
The VenTouch device consists of three (3) inflatable silicone chambers attached to the wall of a knitted polyester support. The VenTouch device is implanted around the base of the heart and positioned at the level of the atrio-ventricular (AV) groove and the adjacent ventricular muscle. The VenTouch device is composed of biocompatible, medical-grade silicone and polyester.
| Study group | Role | What they receive |
|---|---|---|
| VenTouch System Implant | Experimental | The VenTouch System is intended for use in the treatment of functional MR (FMR) in adults who are symptomatic despite optimal medical management. It is indicated for subjects with FMR with essentially normal leaflet anatomy and motion, with mitral valve regurgitation attributable to annular and/or ventricular dilation. It is not intended to treat structural defects/degeneration of the mitral valve. The VenTouch System is intended to provide ventricular support that will encourage beneficial remodeling of the heart and, with adjustable inflatable chambers, it is intended to reduce annular dilation, correct papillary muscle displacement, and restore mitral valve leaflet coaptation, allowing proper closure of the valve, and reducing or eliminating MR. The VenTouch System is indicated for patients who have "moderately severe" or "severe" mitral regurgitation (grade 3 or 4 MR). Receives: Device: VenTouch System |
What is being measured
The primary outcome is the main question the study is designed to answer.
Evaluate procedural feasibility through successful completion of implant and therapy adjustment procedures
Evaluate procedural feasibility through successful completion of implant and therapy adjustment procedures and intraoperative transesophageal echocardiographic (TEE) evidence of MR severity reduction (a minimum of one grade)
Measured: Intra-operative
Evaluate SAE Rates
Evaluate Serious Adverse Event (SAE) rates at 1 month post-therapy adjustment
Measured: 1 Month
Secondary outcomes (6)
Evaluate SAE Rates
Evaluate Serious Adverse Event (SAE) rates
Measured: 36 Months
Evaluate MR Severity
Evaluate MR severity reduction and mitral valve dimension reduction via echocardiographic core lab assessment
Measured: 36 Months
Evaluate Reverse Ventricular Remodeling
Evaluate reverse ventricular remodeling via echocardiographic core lab assessment
Measured: 36 Months
Evaluate Changes in Patient Symptoms by NYHA
Evaluate changes in patient symptoms as assessed by the NYHA functional class
Measured: 36 Months
Evaluate Changes in Patient Functional Status by Six-Minute Walk
Evaluate changes in patient functional status as assessed by Six-Minute Walk
Measured: 36 Months
Evaluate Changes in Patient Functional Status by KCCQ
Evaluate changes in patient functional status as assessed by Kansas City Cardiomyopathy Questionnaire (KCCQ)
Measured: 36 Months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted6 Aug 2018
- Study start25 Mar 2019
- Primary completion31 May 2021 (estimated)
- Study completion31 Dec 2023 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Functional Mitral RegurgitationStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 15 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Mardil Medical
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03616678
- Sponsor's protocol ID
- VenTouch CT007
- Status last verified
- Sep 2020
- First submitted
- 24 Jul 2018
- Last updated
- 9 Sep 2020
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 9 Sep 2020. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Evaluation of The Minimally Invasive VenTouch™ System in The Treatment of Functional Mitral Valve Regurgitation (FMR): OUS Feasibility Study
- ClinicalTrials.gov ID
- NCT03616678
- Acronym / sponsor ID
- VenTouch CT007
- Conditions
- Functional Mitral Regurgitation
- Study type
- Interventional
- Recruitment status
- Unknown status
- Enrolment
- 15 participants (estimated)
- Lead sponsor
- Mardil MedicalIndustry (pharma, biotech, devices)
- Study start
- 25 Mar 2019 (actual)
- Primary completion
- 31 May 2021 (estimated)
- Study completion
- 31 Dec 2023 (estimated)
- First posted
- 6 Aug 2018 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This is a prospective, multi-center, single-arm study to evaluate safety and efficacy of the VenTouch System for treatment of subjects with functional MR.
Detailed description
This is a prospective, multi-center, single-arm study to evaluate safety and efficacy of the VenTouch System for treatment of subjects with functional MR enrolling up to 15 subjects who have been diagnosed with Grade 3-4 functional mitral valve regurgitation and deemed eligible per assessment by the inclusion/exclusion criteria. The duration of the study follow-up is 36 months from the time of therapy adjustment. Data from this trial may be utilized in support of a CE study in Europe and/or a pilot IDE study in the U.S. Follow-up testing will be performed at 1, 3, 6, 12, 24, and 36 months post-therapy adjustment.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| VenTouch System Implant | Experimental | Device: VenTouch SystemThe VenTouch System is intended for use in the treatment of functional MR (FMR) in adults who are symptomatic despite optimal medical management. It is indicated for subjects with FMR with essentially normal leaflet anatomy and motion, with mitral valve regurgitation attributable to annular and/or ventricular dilation. It is not intended to treat structural defects/degeneration of the mitral valve. The VenTouch System is intended to provide ventricular support that will encourage beneficial remodeling of the heart and, with adjustable inflatable chambers, it is intended to reduce annular dilation, correct papillary muscle displacement, and restore mitral valve leaflet coaptation, allowing proper closure of the valve, and reducing or eliminating MR. The VenTouch System is indicated for patients who have "moderately severe" or "severe" mitral regurgitation (grade 3 or 4 MR). |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (11 listed)
- Adults ≥18 years of age
- Symptomatic FMR of grade moderately severe to severe (3 to 4) due to either ischemic or non-ischemic dilated cardiomyopathy with structurally normal leaflets determined by echocardiography (preferably with echocardiographic evidence of EROA ≥ 0.20 cm2)
- NYHA Class II to IV
- Left Ventricular Ejection Fraction (LVEF) 20%-50% determined by echocardiography
- Treatment and compliance with optimal guideline-directed medical therapy for heart failure for at least 30 days
Key exclusion criteria (29 listed)
- Life expectancy of less than 12 months due to conditions other than cardiac status
- Anticipated need for LVAD or transplant within 12 months
- Chronic Obstructive Pulmonary Disease (COPD) requiring continuous home oxygen therapy or chronic outpatient oral steroid use
- American College of Cardiology / American Heart Association (ACC/AHA) Stage D heart failure
- Six-minute walk distance < 150 meters
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| VenTouch SystemThe VenTouch™ System consists of a delivery tool with a pre-loaded implant (VenTouch device) and accessories, which include a sizing tool, PEMS, chamber positioning tool, and accessories kit with luer fitting, tubing clamp, and titanium plug. The VenTouch device is offered in 6 sizes, with 4 different sized inflatable chambers available. Please refer to the VenTouch Instructions for Use for and system details. The VenTouch device consists of three (3) inflatable silicone chambers attached to the wall of a knitted polyester support. The VenTouch device is implanted around the base of the heart and positioned at the level of the atrio-ventricular (AV) groove and the adjacent ventricular muscle. The VenTouch device is composed of biocompatible, medical-grade silicone and polyester. | Device | VenTouch System Implant |
Primary outcome
Evaluate procedural feasibility through successful completion of implant and therapy adjustment procedures
Time frame: Intra-operative
Evaluate procedural feasibility through successful completion of implant and therapy adjustment procedures and intraoperative transesophageal echocardiographic (TEE) evidence of MR severity reduction (a minimum of one grade)
Evaluate SAE Rates
Time frame: 1 Month
Evaluate Serious Adverse Event (SAE) rates at 1 month post-therapy adjustment
6 secondary outcomes
Evaluate SAE Rates
Time frame: 36 Months
Evaluate MR Severity
Time frame: 36 Months
Evaluate Reverse Ventricular Remodeling
Time frame: 36 Months
Evaluate Changes in Patient Symptoms by NYHA
Time frame: 36 Months
Evaluate Changes in Patient Functional Status by Six-Minute Walk
Time frame: 36 Months
Evaluate Changes in Patient Functional Status by KCCQ
Time frame: 36 Months
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 9 Sep 2020.
- Study Sponsor WebsiteLink provided by the sponsor.
- Individual participant dataSharing planned: No
Related trials for Functional Mitral Regurgitation
Recruiting
PRECISE-AFMR I: Transcatheter Mitral Valve Edge-to-Edge Repair for Atrial Functional Mitral Regurgitation in Patients at High Surgical Risk
Atrial Functional, Mitral Regurgitation (MR)
Active, not recruiting
A Feasibility Study of the Millipede Transcatheter Annuloplasty Ring System in Patients With Functional Mitral Regurgitation
Mitral Regurgitation Functional, Mitral Valve Disease
Recruiting
Mitral Valve Edge-to-Edge Repair in Patients With Exercise-Induced Severe Mitral Regurgitation
Heart Failure - NYHA II - IV, Mitral Regurgitation Functional
Recruiting
Bio Refine for Functional Mitral Regurgitation - a Safety & Feasibility Study
Functional Mitral Regurgitation
Recruiting
Effects of tDCS for Enhancing Cognitive Function in Individuals With Persistent Post-Concussion Syndrome
Transcranial Direct Current Stimulation, Post-Concussion Syndrome
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
12 sites in 7 countries: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing VenTouch System in people with Functional Mitral Regurgitation, run by Mardil Medical at 12 sites in 7 countries.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 11 inclusion and 29 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 9 Sep 2020. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 12 sites in Canada, France, Germany, Hungary, Netherlands and 2 more countries. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
Contact Sarah Hase, BS (763-710-4518, shase@mardil.com), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Evaluate procedural feasibility through successful completion of implant and therapy adjustment procedures (time frame: Intra-operative). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Sep 2020.