Dental ImplantsNCT03640910
Attachment Systems for Implant Overdenture
A study testing OT Equators® (Rhein83) and Locator® (Zest) in people with Dental Implants and Dental Prosthesis Failure, run by Rhein 83 Srl at 1 site in Italy.
Trial summary
The aim of this randomized controlled trial is to compare peri-implant tissue health, number of complications, and patient's preference between two unsplinted overdenture attachments. Read more about this study
- Who is it for?
- Ages 18 years and olderHealthy volunteers can take part
- Conditions the study is for
- Dental Implants, Dental Prosthesis Failure
- What is being tested?
- OT Equators® (Rhein83) and Locator® (Zest)
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 43 participants
- Where
- 1 siteItaly
- Study dates
- 1 Jan 2018to 31 Dec 2020
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- Any healthy individual (ASA 1 and 2)( (Dexter and Thompson, 2001), aged 18 years or older at the time of enrollment, with complete edentulous mandible, or a failing dentition in the mandible, scheduled to receive an implant supported overdenture, will be considered eligible for the study.
Who cannot join
- General contraindications to oral surgery, pregnancy or nursing, intravenous bisphosphonate therapy, alcohol or drug abuse, heavy smoking (≥ 20 cigarettes/day), radiation therapy to the head or neck region within the last five years, parafunctional activity, untreated periodontitis, and allergy or adverse reactions to the restorative materials.
Trial locations and contacts
1 site in 1 country.
About this study
Official title: A Cluster-randomized Multicenter Trial Comparing OT-Equator® Versus Locator® Attachments to Retain an Early Loaded Implant Overdenture on Two or Three Implants
The aim of this randomized controlled trial is to compare peri-implant tissue health, number of complications, and patient's preference between two unsplinted overdenture attachments.
Read the detailed description
Study design: A cluster-randomized multicenter trial of parallel group design and two arms. Patients with complete edentulous mandible in needed of an implant retained overdenture, will be randomly clustered to receive two or three unsplinted implants. Afterwards, patients that have been randomized to receive two implants will be randomized to receive OT Equator® attachment (Rhein'83, Bologna, Italy) in the test group, or Locator® attachment (Zest Anchors LLC, Espandido, CA, USA) in the control group.
Patients will be selected and consecutively treated in 10 private and public (University) centers in Europe, between December 2017 and December 2018. This study will be conducted in accordance with the principles outlined in the Helsinki Declaration of 1964 for biomedical research involving human subjects, as amended in 2013, and will receive ethical approval by Ethical Committees of the various centers. Patients will be duly informed about the nature of the study. A written informed consent form for surgical and prosthetic procedures, as well as for the use of the clinical and radiological data, will be obtained for each patient. The present research will be registered in the Clinical trial.gov and the manuscript will be written according to the CONSORT guidelines.
Any healthy individual (ASA 1 and 2), aged 18 years or older at the time of enrollment, with complete edentulous mandible, or a failing dentition in the mandible, scheduled to receive an implant supported overdenture, will be considered eligible for the study. Exclusion criteria are the general contraindications to oral surgery, pregnancy or nursing, intravenous bisphosphonate therapy, alcohol or drug abuse, heavy smoking (≥ 20 cigarettes/day), radiation therapy to the head or neck region within the last five years, parafunctional activity, untreated periodontitis, and allergy or adverse reactions to the restorative materials.
Preoperative photographs, panoramic x-rays, and periodontal screening have to be obtained for initial screening and evaluation. Hopeless teeth (in the mandible) have to be extracted 3 months before implant placement and new prosthesis delivery. All of the patients will receive a temporary complete removable denture before implant placement, according to the respective functional and esthetic requirements. If the actual complete removable denture is judged accurate from both patients and clinician, it could be used as temporary solution.
On the day of the surgery, a single dose of an antibiotic (either 2 g of amoxicillin or 600 mg of clindamycin or 500 mg of azitromicin or claritromicin if allergic to penicillin) will be administered 1 h before implant placement (2017 AHA). Immediately before surgery, the participants will rinse with a 0.2% chlorhexidine mouthwash for 1 min. Local anesthesia preferred by the surgeon will be administered. Flapless, or a minimally invasive mucoperiosteal flaps will be elevated. Then, the patients will be randomly clustered to receive two or three unsplinted implants according to congealed indication contained in a close enveloped and derived from a pre-generated list. Afterwards, only the patients that will be randomized to receive two implants will be randomized to receive OT Equator® attachment (Rhein'83, Bologna, Italy) in the test group, or Locator® attachment (Zest Anchors LLC, Espandido, CA, USA) in the control group.
Implants have to be placed in the interforaminal region of the mandible according to a one-stage approach.
Three-IRO: center implant will be placed in the midline, and the distal implants were placed 11 mm distal, aligned at a 0-20-degree inclination corresponding to the center implants (with up to an extensive 40 degrees of divergence between implants them).
Two-IRO: implants will be placed in the canine region of the mandible with an interconnecting line approaching parallelism with the terminal mandibular hinge axis, and an extensive 40 degrees of divergence between implants them.
Any brand of implants that provide either Locator® or OT-Equator® abutments can be placed according to the manufacturer suggestions, in order to achieve an insertion torque of at least 35 N cm. The implant lengths will be dictated by the preoperative radiographs. Jaw bone quality will be rated during the dental implant surgery, by the tactile resistance during drilling, allowing an objective evaluation according to the Lekholm \& Zarb index.
After surgery, the patients will be instructed to avoid brushing and trauma at the surgical site. A post-surgical cold and soft diet will be recommended. Smokers will be recommended to avoid smoking for 2 weeks days postoperatively, and oral hygiene instructions will be given (Chlorhexidine 0,12% rinses 3 times/day) . Analgesics (600 mg of ibuprofen or other) will be prescribed as needed. Sutures (if present) will be removed after ten days.
The prosthetic procedures will begin eight weeks after implant placement. A reliable, fully extended impressions of both jaws will be taken. Then, a definitive polysulfide-based or polyether impression will be made by using a customized acrylic resin tray, and master cast will be poured with low expansion, class IV gypsum. Intermaxillary relation using registration plates or clinical bite index, functional occlusal analysis, face-bow, and occlusal vertical dimension have to be taken. Master cast and antagonists will be mounted in a semi adjustable articulator and a diagnostic prosthetic setup will be made and tried in the patient's mouth, in which the functional and aesthetic parameters will be evaluated.
A new metal reinforced, complete removable denture will be delivered in both groups within 4 weeks after second surgery, according to an early loading protocol. The healing abutments will be unscrewed and the implant connections have to be disinfected. Randomized attachment system will be placed and tightened according to the manufacturer.
Test Group (OT Equator®)
After gingival healing the newest low-profile OT Equators® (Rhein83) will be screwed on to the implants, using the OT Equator® square screwdriver (Rhein83), with a torque range of 22-25 N cm. The cuff heights ranged from 0.5 to 7.0 mm, depending on the height of the transition zone of each implant, easily measured using the color-coded millimeter Cuff Height Measurer Gauge (Rhein83) after healing abutment removal. Afterward, spaces to accept the female housing steel cage will be prepared in the fitting surface of the removable complete mandibular denture. Silicone protective discs (Rhein83) will be placed over the OT Equator® attachments. Extra-soft (yellow, 600 g) retentive caps will be initially placed in to the female steel housing, attached to the OT Equator and finally fixed to the denture using self-cured acrylic resin while the patient held the dentures in occlusion, directly chairside. After complete polymerization, the denture will be picked up and silicone discs removed. Acrylic excess will be trimmed and the denture will be refined and polished. One month after prosthesis delivery, the yellow retentive caps will be replaced with a stronger type (pink, 1200 g).
Control Group (Locators) The low-profile attachments Locator® (Zest) will be screwed on to the implants, using the Locator® screwdriver (Zest), with a torque range of 20-25 N cm. The cuff heights of 2.5 or 4.0 mm, depending on the height of the transition zone of each implant, measured using the deep probe of the implant line after healing abutment removal. Afterward, spaces to accept the female housing steel cage will be prepared in the fitting surface of the removable complete mandibular denture. Silicone protective white rings (Zest) will be placed over the Locator attachments. Passive black caps will be used to load the attachment. Attached to the Locator and finally fixed to the denture using self-cured acrylic resin while the patient held the dentures in occlusion, directly chairside. After complete polymerization, the denture will be picked up and white rings removed. Acrylic excess will be trimmed and the denture will be refined and polished. Black caps will be removed and blue ones (6N) will be mounted in the steel housing. One month after prosthesis delivery, the retentive caps will be replaced with a pink matrix (12N).
In both groups, the occlusion will be developed to deliver a lingualized occlusion with balanced contacts during function, avoiding any premature contacts. Nevertheless, when the opposing arch is a removable complete denture, the over-jet has to be left purposely broad, from 2 to 5 mm in order to avoid interferences during function. Instructions will be given to the patients, and recall visits will be scheduled for occlusal adjustments and oral hygiene quality control every six months and, for retentive cap replacement, every year.
Outcomes: implant and prosthetic success and survival rate; biologic and technical complications; marginal bone loss; patients' satisfaction (Oral Health Impact Profile, OHIP-22).
- Conditions
- Dental Implants, Dental Prosthesis Failure
- Being tested
- OT Equators® (Rhein83), Locator® (Zest)
- Keywords
- Dental implants, Overdenture, Randomized controlled trial
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
OT Equators® (Rhein83)Device
Attachment systems to retain an implant overdenture
Locator® (Zest)Device
Attachment systems to retain an implant overdenture
| Study group | Role | What they receive |
|---|---|---|
| OT Equators® (Rhein83) | Experimental | After gingival healing the newest low-profile OT Equators® (Rhein83) will be screwed on to the implants, using the OT Equator® square screwdriver (Rhein83), with a torque range of 22-25 N cm. The cuff heights ranged from 0.5 to 7.0 mm, depending on the height of the transition zone of each implant, easily measured using the color-coded millimeter Cuff Height Measurer Gauge (Rhein83) after healing abutment removal. Receives: Device: OT Equators® (Rhein83) |
| Locator® (Zest) | Active comparator | The low-profile attachments Locator® (Zest) will be screwed on to the implants, using the Locator® screwdriver (Zest), with a torque range of 20-25 N cm. The cuff heights of 2.5 or 4.0 mm, depending on the height of the transition zone of each implant, measured using the deep probe of the implant line after healing abutment removal. Receives: Device: Locator® (Zest) |
What is being measured
The primary outcome is the main question the study is designed to answer.
Implant and prosthetic success rate
An implant will be considered a failure if it presented with any mobility, assessed by tapping or rocking the implant head with the metallic handles of two instruments, progressive marginal bone loss or infection, and any mechanical complications rendering the implant unusable, although still mechanically stable in the bone.
Measured: Up to 5 years after implant placement
Secondary outcomes (2)
Marginal bone loss
Marginal bone levels will be assessed using intraoral digital or conventional periapical radiographs taken with the paralleling technique by means of Rinn-type collimator at implant placement, loading (baseline) and one year after loading. The marginal bone levels will be determined from linear measurements performed by two independent (semi-blinded) trained examiners on each periapical radiograph, from the mesial and distal margin of the implant neck to the most coronal point where the bone appeared to be in contact with the implant.
Measured: Up to 5 years after implant placement
Oral Health Impact Profile
Oral Health Impact Profile(OHIP-19) questionnaire, which will be completed by the participants every year after prosthesis delivery. The questionnaire consists of seven subscales FL = Functional limitation, P1 = Physical pain, P2 = Psychological discomfort, D1 = Physical disability, D2 = Psychological disability, D3 = Social disability, H = Handicap, with two to three questions each. Participants chose from five possible responses for each question as follows: 4= very often; 3= fairly often; 2= occasionally; 1= hardly ever; 0= never/don't know. Lower OHIP total scores are suggestive of improvement in oral health-related quality of life. The questionnaire will be administered before treatment and one month and one year after definitive prosthesis delivery by a blinded examiner.
Measured: Up to 5 years after implant placement
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted21 Aug 2018
- Study start1 Jan 2018
- Primary completion30 Jan 2020
- Study completion31 Dec 2020
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Dental ImplantsStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind
- Who is masked
- Outcomes assessor
- Enrolment
- 43 participants (actual)
Sponsor and investigators
- Lead sponsor
- Rhein 83 Srl
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Principal investigator, Marco Tallarico, Rhein 83 Srl
- Investigators
- Marco Tallarico, Dr, Principal investigator, University of Aldent, Tirana
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03640910
- Sponsor's protocol ID
- In_Vitro_Eq_Loc_Smart
- Status last verified
- Feb 2021
- First submitted
- 29 Mar 2018
- Last updated
- 9 Feb 2021
- Results posted
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
Study at a glance
From the registry record, last updated by the sponsor on 9 Feb 2021. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Cluster-randomized Multicenter Trial Comparing OT-Equator® Versus Locator® Attachments to Retain an Early Loaded Implant Overdenture on Two or Three Implants
- ClinicalTrials.gov ID
- NCT03640910
- Acronym / sponsor ID
- In_Vitro_Eq_Loc_Smart
- Conditions
- Dental Implants, Dental Prosthesis Failure
- Keywords
- Dental implants, Overdenture, Randomized controlled trial
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 43 participants (actual)
- Lead sponsor
- Rhein 83 SrlIndustry (pharma, biotech, devices)
- Study start
- 1 Jan 2018 (actual)
- Primary completion
- 30 Jan 2020 (actual)
- Study completion
- 31 Dec 2020 (actual)
- First posted
- 21 Aug 2018 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The aim of this randomized controlled trial is to compare peri-implant tissue health, number of complications, and patient's preference between two unsplinted overdenture attachments.
Detailed description
Study design: A cluster-randomized multicenter trial of parallel group design and two arms. Patients with complete edentulous mandible in needed of an implant retained overdenture, will be randomly clustered to receive two or three unsplinted implants. Afterwards, patients that have been randomized to receive two implants will be randomized to receive OT Equator® attachment (Rhein'83, Bologna, Italy) in the test group, or Locator® attachment (Zest Anchors LLC, Espandido, CA, USA) in the control group.
Patients will be selected and consecutively treated in 10 private and public (University) centers in Europe, between December 2017 and December 2018. This study will be conducted in accordance with the principles outlined in the Helsinki Declaration of 1964 for biomedical research involving human subjects, as amended in 2013, and will receive ethical approval by Ethical Committees of the various centers. Patients will be duly informed about the nature of the study. A written informed consent form for surgical and prosthetic procedures, as well as for the use of the clinical and radiological data, will be obtained for each patient. The present research will be registered in the Clinical trial.gov and the manuscript will be written according to the CONSORT guidelines.
Any healthy individual (ASA 1 and 2), aged 18 years or older at the time of enrollment, with complete edentulous mandible, or a failing dentition in the mandible, scheduled to receive an implant supported overdenture, will be considered eligible for the study. Exclusion criteria are the general contraindications to oral surgery, pregnancy or nursing, intravenous bisphosphonate therapy, alcohol or drug abuse, heavy smoking (≥ 20 cigarettes/day), radiation therapy to the head or neck region within the last five years, parafunctional activity, untreated periodontitis, and allergy or adverse reactions to the restorative materials.
Preoperative photographs, panoramic x-rays, and periodontal screening have to be obtained for initial screening and evaluation. Hopeless teeth (in the mandible) have to be extracted 3 months before implant placement and new prosthesis delivery. All of the patients will receive a temporary complete removable denture before implant placement, according to the respective functional and esthetic requirements. If the actual complete removable denture is judged accurate from both patients and clinician, it could be used as temporary solution.
On the day of the surgery, a single dose of an antibiotic (either 2 g of amoxicillin or 600 mg of clindamycin or 500 mg of azitromicin or claritromicin if allergic to penicillin) will be administered 1 h before implant placement (2017 AHA). Immediately before surgery, the participants will rinse with a 0.2% chlorhexidine mouthwash for 1 min. Local anesthesia preferred by the surgeon will be administered. Flapless, or a minimally invasive mucoperiosteal flaps will be elevated. Then, the patients will be randomly clustered to receive two or three unsplinted implants according to congealed indication contained in a close enveloped and derived from a pre-generated list. Afterwards, only the patients that will be randomized to receive two implants will be randomized to receive OT Equator® attachment (Rhein'83, Bologna, Italy) in the test group, or Locator® attachment (Zest Anchors LLC, Espandido, CA, USA) in the control group.
Implants have to be placed in the interforaminal region of the mandible according to a one-stage approach.
Three-IRO: center implant will be placed in the midline, and the distal implants were placed 11 mm distal, aligned at a 0-20-degree inclination corresponding to the center implants (with up to an extensive 40 degrees of divergence between implants them).
Two-IRO: implants will be placed in the canine region of the mandible with an interconnecting line approaching parallelism with the terminal mandibular hinge axis, and an extensive 40 degrees of divergence between implants them.
Any brand of implants that provide either Locator® or OT-Equator® abutments can be placed according to the manufacturer suggestions, in order to achieve an insertion torque of at least 35 N cm. The implant lengths will be dictated by the preoperative radiographs. Jaw bone quality will be rated during the dental implant surgery, by the tactile resistance during drilling, allowing an objective evaluation according to the Lekholm \& Zarb index.
After surgery, the patients will be instructed to avoid brushing and trauma at the surgical site. A post-surgical cold and soft diet will be recommended. Smokers will be recommended to avoid smoking for 2 weeks days postoperatively, and oral hygiene instructions will be given (Chlorhexidine 0,12% rinses 3 times/day) . Analgesics (600 mg of ibuprofen or other) will be prescribed as needed. Sutures (if present) will be removed after ten days.
The prosthetic procedures will begin eight weeks after implant placement. A reliable, fully extended impressions of both jaws will be taken. Then, a definitive polysulfide-based or polyether impression will be made by using a customized acrylic resin tray, and master cast will be poured with low expansion, class IV gypsum. Intermaxillary relation using registration plates or clinical bite index, functional occlusal analysis, face-bow, and occlusal vertical dimension have to be taken. Master cast and antagonists will be mounted in a semi adjustable articulator and a diagnostic prosthetic setup will be made and tried in the patient's mouth, in which the functional and aesthetic parameters will be evaluated.
A new metal reinforced, complete removable denture will be delivered in both groups within 4 weeks after second surgery, according to an early loading protocol. The healing abutments will be unscrewed and the implant connections have to be disinfected. Randomized attachment system will be placed and tightened according to the manufacturer.
Test Group (OT Equator®)
After gingival healing the newest low-profile OT Equators® (Rhein83) will be screwed on to the implants, using the OT Equator® square screwdriver (Rhein83), with a torque range of 22-25 N cm. The cuff heights ranged from 0.5 to 7.0 mm, depending on the height of the transition zone of each implant, easily measured using the color-coded millimeter Cuff Height Measurer Gauge (Rhein83) after healing abutment removal. Afterward, spaces to accept the female housing steel cage will be prepared in the fitting surface of the removable complete mandibular denture. Silicone protective discs (Rhein83) will be placed over the OT Equator® attachments. Extra-soft (yellow, 600 g) retentive caps will be initially placed in to the female steel housing, attached to the OT Equator and finally fixed to the denture using self-cured acrylic resin while the patient held the dentures in occlusion, directly chairside. After complete polymerization, the denture will be picked up and silicone discs removed. Acrylic excess will be trimmed and the denture will be refined and polished. One month after prosthesis delivery, the yellow retentive caps will be replaced with a stronger type (pink, 1200 g).
Control Group (Locators) The low-profile attachments Locator® (Zest) will be screwed on to the implants, using the Locator® screwdriver (Zest), with a torque range of 20-25 N cm. The cuff heights of 2.5 or 4.0 mm, depending on the height of the transition zone of each implant, measured using the deep probe of the implant line after healing abutment removal. Afterward, spaces to accept the female housing steel cage will be prepared in the fitting surface of the removable complete mandibular denture. Silicone protective white rings (Zest) will be placed over the Locator attachments. Passive black caps will be used to load the attachment. Attached to the Locator and finally fixed to the denture using self-cured acrylic resin while the patient held the dentures in occlusion, directly chairside. After complete polymerization, the denture will be picked up and white rings removed. Acrylic excess will be trimmed and the denture will be refined and polished. Black caps will be removed and blue ones (6N) will be mounted in the steel housing. One month after prosthesis delivery, the retentive caps will be replaced with a pink matrix (12N).
In both groups, the occlusion will be developed to deliver a lingualized occlusion with balanced contacts during function, avoiding any premature contacts. Nevertheless, when the opposing arch is a removable complete denture, the over-jet has to be left purposely broad, from 2 to 5 mm in order to avoid interferences during function. Instructions will be given to the patients, and recall visits will be scheduled for occlusal adjustments and oral hygiene quality control every six months and, for retentive cap replacement, every year.
Outcomes: implant and prosthetic success and survival rate; biologic and technical complications; marginal bone loss; patients' satisfaction (Oral Health Impact Profile, OHIP-22).
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (outcomes assessor)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| OT Equators® (Rhein83) | Experimental | Device: OT Equators® (Rhein83)After gingival healing the newest low-profile OT Equators® (Rhein83) will be screwed on to the implants, using the OT Equator® square screwdriver (Rhein83), with a torque range of 22-25 N cm. The cuff heights ranged from 0.5 to 7.0 mm, depending on the height of the transition zone of each implant, easily measured using the color-coded millimeter Cuff Height Measurer Gauge (Rhein83) after healing abutment removal. |
| Locator® (Zest) | Active comparator | Device: Locator® (Zest)The low-profile attachments Locator® (Zest) will be screwed on to the implants, using the Locator® screwdriver (Zest), with a torque range of 20-25 N cm. The cuff heights of 2.5 or 4.0 mm, depending on the height of the transition zone of each implant, measured using the deep probe of the implant line after healing abutment removal. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (1 listed)
- Any healthy individual (ASA 1 and 2)( (Dexter and Thompson, 2001), aged 18 years or older at the time of enrollment, with complete edentulous mandible, or a failing dentition in the mandible, scheduled to receive an implant supported overdenture, will be considered eligible for the study.
Key exclusion criteria (1 listed)
- General contraindications to oral surgery, pregnancy or nursing, intravenous bisphosphonate therapy, alcohol or drug abuse, heavy smoking (≥ 20 cigarettes/day), radiation therapy to the head or neck region within the last five years, parafunctional activity, untreated periodontitis, and allergy or adverse reactions to the restorative materials.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| OT Equators® (Rhein83)Attachment systems to retain an implant overdenture | Device | OT Equators® (Rhein83) |
| Locator® (Zest)Attachment systems to retain an implant overdenture | Device | Locator® (Zest) |
Primary outcome
Implant and prosthetic success rate
Time frame: Up to 5 years after implant placement
An implant will be considered a failure if it presented with any mobility, assessed by tapping or rocking the implant head with the metallic handles of two instruments, progressive marginal bone loss or infection, and any mechanical complications rendering the implant unusable, although still mechanically stable in the bone.
2 secondary outcomes
Marginal bone loss
Time frame: Up to 5 years after implant placement
Oral Health Impact Profile
Time frame: Up to 5 years after implant placement
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 9 Feb 2021.
Related trials for Dental Implants
Not yet recruitingPhase 1/2
Effect of Povidone Iodine on the Dental Implant Internal Surface Microbiome
Dental Implant
Recruiting
The Application of a Biphasic Calcium Sulfate Graft Material in Sinus Floor Elevation
Alveolar Bone Loss, Edentulism Nos
RecruitingObservational study
Changes in Oral Health-related Quality of Life (OHRQoL) During Full Arch Implant Treatment
Edentulous Mouth, Quality of Life
Not yet recruitingObservational study
Plaque and Bleeding on Probing Around Implants Supporting Fixed Full-Arch Dental Prostheses
Peri-Implant Health
Enrolling by invitation
Investigation of the Effect of Horizontal Platelet Rich Fibrin Placed in Tooth Extraction Sockets on Bone Formation
Tooth Loss, Dental Implant Failed
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Marco Tallarico, Dr principal investigator
University of Aldent, Tirana
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing OT Equators® (Rhein83) and Locator® (Zest) in people with Dental Implants and Dental Prosthesis Failure, run by Rhein 83 Srl at 1 site in Italy.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 9 Feb 2021. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Implant and prosthetic success rate (time frame: Up to 5 years after implant placement). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Feb 2021.