AzTrials
AzTrials

Mitral RegurgitationINTERLUDENCT03661398

Caisson Transcatheter Mitral Valve Replacement (TMVR)

A study testing Transcatheter Mitral Valve Replacement in people with Mitral Regurgitation and Mitral Valve Disease, run by Caisson Interventional LLC at 1 site in United States.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The purpose of this study is to assess the safety and performance of Transcatheter Mitral Valve Replacement (TMVR) system for the treatment of severe, symptomatic mitral regurgitation (MR). Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Transcatheter Mitral Valve Replacement
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
75 participants
Where
1 siteUnited States
Study dates
20 Jul 2017to Aug 2025
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Has severe mitral regurgitation
  • New York Heart Association (NYHA) Class II, III, IVa or heart failure
  • High risk for cardiovascular surgery

Who cannot join

  • Excessive calcification or thickening of mitral valve annulus
  • Severe mitral stenosis, fused commissures, valvular vegetation or mass
  • Left ventricular end diastolic dimension > 7cm
  • Left ventricular outflow tract obstruction
  • Severe right ventricular dysfunction
  • Stroke within 90 days; transient ischemic attack or myocardial infarction within 30 days of the index procedure

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Pennsylvania State University

    Hershey, Pennsylvania, 17033

Other trials in United States

About this study

Official title: Clinical Investigation of the Caisson Transcatheter Mitral Valve Replacement (TMVR) System for Percutaneous Mitral Valve Replacement in Patients With Symptomatic Mitral Regurgitation

The purpose of this study is to assess the safety and performance of Transcatheter Mitral Valve Replacement (TMVR) system for the treatment of severe, symptomatic mitral regurgitation (MR).

Read the detailed description

The treatment guidelines for valvular heart disease indicate that surgical correction of primary mitral valve regurgitation (MR) is a Class I recommendation. Recent evidence indicates that valve replacement is at least as effective as repair in both primary and secondary MR patients. However, many patients are not referred for surgery as they are considered to be too high of a risk to undergo on-pump, open-heart procedures. Percutaneous aortic valve replacement has made treatment of stenosed aortic valves available to high-risk surgical patients who would have otherwise been medically managed. Percutaneous mitral valve (MV) replacement offers similar advantages. The feasibility of percutaneous MV replacement has been demonstrated in early feasibility studies. To meet this medical need, Caisson Interventional has developed a percutaneous delivery system for a bioprosthetic mitral valve. As with patients with aortic valve (AV) deficiencies, this device can be used to provide needed therapy to patients who might not otherwise receive treatment beyond medical therapy. This study will provide information on the safety and performance of this system.

Being tested
Transcatheter Mitral Valve Replacement
Keywords
Percutaneous mitral valve replacement, Trans-septal mitral valve replacement, Transcatheter mitral valve replacement, TMVR, Primary MR, Secondary MR, Structural Heart Disease, Heart Failure, Degenerative Mitral Valve Disease, Functional Mitral Valve Disease
Medical subject headings
Mitral Valve Insufficiency, Disease, Heart Valve Diseases, Heart Failure

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Transcatheter Mitral Valve ReplacementDevice

    Also called Caisson Transcatheter Mitral Valve Replacement (TMVR) System

    All eligible patients will be in the treatment arm for treatment with the Caisson Transcatheter Mitral Valve Replacement (TMVR) System. There is no control (comparator) arm for this study.

Study groups in NCT03661398
Study groupRoleWhat they receive
Transcatheter Mitral Valve ReplacementExperimentalPatients with symptomatic mitral regurgitation (garde 3 or 4), determined to be a high risk for cardiovascular surgery, will be treated with the Caisson Transcatheter Mitral Valve Replacement (TMVR) System
Receives: Device: Transcatheter Mitral Valve Replacement

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of patients without Major Adverse Events (MAEs)

    Freedom from major adverse events including death, stroke, myocardial infarction and surgical reintervention through 30 days

    Measured: 30 days

Secondary outcomes (2)
  1. Number of patients with successful delivery and implantation of the prosthetic valve (technical success)

    Successful delivery and retrieval of the transcatheter mitral valve delivery system; deployment and correct positioning (via intraoperative imaging) in the appropriate anatomic location of prosthetic valve with no requirement for additional surgery

    Measured: Intra-operative

  2. Number of living, stroke-free patients with prosthetic valve in place (device success)

    Patient is alive, stroke-free, original intended device in place (echo), no mitral valve surgical re-intervention required

    Measured: 30 days

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted7 Sep 2018
  2. Study start20 Jul 2017
  3. Primary completionAug 2020 (estimated)
  4. Study completionAug 2025 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
75 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03661398
Sponsor's protocol ID
INT-001
Acronym
INTERLUDE
Status last verified
Jan 2020
First submitted
5 Sep 2018
Last updated
28 Jan 2020
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Transcatheter Mitral Valve Replacement in people with Mitral Regurgitation and Mitral Valve Disease, run by Caisson Interventional LLC at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 28 Jan 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Number of patients without Major Adverse Events (MAEs) (time frame: 30 days). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 28 Jan 2020.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.