Abdominal Aortic AneurysmNCT03687489
Safety and Efficacy Study of Abdominal Aortic Aneurysm Stent Graft System
A study testing Abdominal Aortic Aneurysm Stent Graft System in people with Abdominal Aortic Aneurysm, run by Lifetech Scientific (Shenzhen) Co., Ltd. at 22 sites in China.
Trial summary
A prospective, multi-centre, objective performance criteria clinical trial to evaluate the safety and efficacy of Abdominal Aortic Aneurysm Stent Graft System manufactured by Lifetech Scientific (Shenzhen) Co., LTD. for the infrarenal abdominal aortic aneurysm. Read more about this study
- Who is it for?
- Ages 18 to 85 years
- Conditions the study is for
- Abdominal Aortic Aneurysm
- What is being tested?
- Abdominal Aortic Aneurysm Stent Graft System
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 156 participants
- Where
- 22 sitesChina
- Study dates
- 30 Sep 2018to 31 Mar 2025
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 85 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- 1. Patients aged greater than 18 years old and less than 85 years old, regardless of gender.
- 2. Patients who can understand the purpose of the trial, voluntarily participate in and sign the informed consent, and are willing to complete the follow-up according to the requirements of the protocol.
- 3. Patients diagnosed with Infrarenal Abdominal Aortic Aneurysm and should meet at least one of the following conditions:
- The maximum diameter of abdominal aortic aneurysm ≥50mm in male patients, or the maximum diameter of abdominal aortic aneurysm ≥45mm in female patients.
- The maximum diameter of abdominal aortic aneurysm ≥40mm and the diameter increased by more than 5mm in the last 6 months (In this case, the diameter data of abdominal aortic aneurysm should be traceable within 6 months).
- The abdominal aortic aneurysm compresses vital organs and causes symptoms (such as abdominal pain, lower back pain, etc.) 4. The range of proximal aneurysm neck diameter of the abdominal aortic aneurysm is between 17mm to 32mm.
Show all 10Show fewer
- 5. The length of the proximal aneurysm neck of abdominal aortic aneurysm≥10mm, and the angle of the proximal aneurysm neck ≤75 °.
- 6. The range of the diameter of the iliac artery anchoring area is between 8mm to 22mm.
- 7.The length of the iliac artery anchoring area≥15mm.
- 8. The patient has a suitable iliac and femoral artery approach.
Who cannot join
- 1. Patients with severe stenosis, calcification, or mural thrombus in the anchoring area of the stent and easily lead to incomplete stent apposition.
- 2. Patients with rupture of an abdominal aortic aneurysm or threatened rupture.
- 3. Patients with abdominal aortic dissection.
- 4. Patients with mycotic or infectious abdominal aortic aneurysms.
- 5. Patients with a history of myocardial infarction or unstable angina pectoris for 6 months. Characteristics of unstable angina pectoris: angina symptoms gradually increased, new onset of rest or night angina pectoris or occurrence of angina prolonged.
- 6. Patients with any transient ischemic attack (TIA) or ischemic stroke within 3 months.
Show all 15Show fewer
- 7. Patients with a history of allergy to contrast media, stents and conveyor materials (including nickel and titanium, polyester, PTFE, and nylon polymer materials).
- 8. A patient with connective tissue diseases such as Marfan syndrome, Eaton syndrome, or Bessel's disease.
- 9. Patients with liver dysfunction: Alanine transaminase (ALT) or Aspartate transaminase (AST) were five times higher than the normal upper limit;serum total bilirubin (STB) was two times higher than the normal upper limit.
- 10. Patients with renal dysfunction: Serum creatinine (Cr) was two times higher than the normal upper limit.
- 11. Life expectancy is less than one year.
- 12. Patients with major organ failure or other serious diseases;
- 13. Patients who were not suitable for endovascular treatment, judged by the investigator.
- 14. Pregnant or lactating women or women who plan to get pregnant.
- 15. The patients participated in other clinical trials and did not come out of the group or withdraw within the first 3 months of the screening period of this trial.
Trial locations and contacts
22 sites in 1 country.
22 sites in 1 country
China22 sites
Chinese PLA General Hospita
Beijing, Beijing Municipality
The Second Xiangya Hospital of Central South University
Changsha, Hunan
Xiangya Hospital Central South University
Changsha, Hunan
The First Affiliated Hospital of Fujian Medical University
Fuzhou, Fujian
The Frist Affiliated Hospital, Zhejiang University
Hangzhou, Zhejiang
The Second Affiliated Hospital of Zhejiang University School of Medicine
Hangzhou, Zhejiang
Qilu Hospital of Shandong University
Jinan, Shandong
Shandong Provincial Hospital
Jinan, Shandong
Frist Affiliated Hospital of Kunming Medical University
Kunming, Yunnan
Yan'an Hospital of Kunming City
Kunming, Yunnan
The Frist Hospital of Lanzhou University
Lanzhou, Gansu
Liuzhou General Hospital
Liuzhou, Guangxi
The Affiliated Hospital of Southwest Medical University
Luzhou, Sichuan
Jiangsu Province Hospital
Nanjing, Jiangsu
The First Affiliated Hospital of Guangxi Medical University
Nanning, Guangxi
Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine
Shanghai, Shanghai Municipality
The Second Hospital of Heibei Medical University
Shijiazhuang, Hebei
Tianjing Medical University General Hospital
Tianjin, Tianjin Municipality
The First Affiliated Hospital of Xinjiang Medical University
Ürümqi, Xinjiang
Renming Hospital of Wuhan University
Wuhan, Hubei
Xijing Hospital, The Fourth Military Medical University
Xi’an, Shanxi
General Hospital of Ningxia Medical University
Yinchuan, Ningxia
About this study
Official title: Safety and Efficacy Study of Abdominal Aortic Aneurysm Stent Graft System for Infrarenal Abdominal Aortic Aneurysm: A Prospective, Multi-center, Objective Performance Criteria Clinical Trial
A prospective, multi-centre, objective performance criteria clinical trial to evaluate the safety and efficacy of Abdominal Aortic Aneurysm Stent Graft System manufactured by Lifetech Scientific (Shenzhen) Co., LTD. for the infrarenal abdominal aortic aneurysm.
Read the detailed description
This clinical trial was conducted in a qualified clinical trial institution. Investigators will use Abdominal Aortic Aneurysm Stent Graft System manufactured by Lifetech Scientific (Shenzhen) Co., LTD. to treat patients with Infrarenal Abdominal Aortic Aneurysm. This is a Prospective, Multi-center, Objective Performance Criteria Clinical Trial. It is expected to submit to the ethics committee of the lead unit for review in March 2018, and complete the implantation of 156 patients in 22 centres nationwide within 12 months, and interim follow-up was conducted before discharge, 30 days after surgery, 6 months after surgery and 12 months after surgery, long-term follow-up will be performed at 24 months postoperatively, 36 months postoperatively, 48 months postoperatively and 60 months postoperatively.
This trial will evaluate whether the device reached the primary safety endpoint and primary efficacy endpoint through two primary endpoint indicators: the incidence of major adverse events (MAE) within 30 days and the success rate of abdominal aortic aneurysm treatment 12 months after surgery. This trail will evaluate whether the device reached the secondary safety endpoint and primary efficacy endpoint through several secondary endpoint indicators: Perioperative (intraoperative to postoperative 30 days) delivery related complications incidence rate (including the transabdominal surgery caused by intraoperative conveyors, the hemorrhage in the middle iliac artery, the hemorrhage in the femoral artery at the puncture site, the hematoma and the pseudoaneurysm), the incidence of acute lower limb ischemia before discharge and 30 days after surgery, all-cause mortality at 6 months, 12 months and 2-5 years after surgery, abdominal aortic aneurysm-related mortality at 6 months, 12 months and 2-5 years after surgery, the incidence of severe adverse events (SAE) at 6 months, 12 months and 2-5 years after surgery, the incidence of the device-related adverse events (AE) at 6 months, 12 months and 2-5 years after surgery, the incidence of type I or type III leakage at 6 months, 12 months after surgery, the incidence of displacement of Abdominal Aortic Aneurysm Stent at 6 months, 12 months after surgery and the incidence of conversion from abdominal aortic aneurysm treatment to open surgery or secondary surgery intervention at 6 months, 12 months and 2-5 years after surgery. According to the guidelines for clinical trials of aortic stent system, the sponsor will apply for CFDA listing registration after completing a 12-month primary endpoint assessment. According to the guidelines for clinical trials of aortic covered stent system, the sponsor will apply for CFDA listing registration after completing a 12-month primary endpoint assessment, and annually follow-up will be conducted until the fifth year for the long-term efficacy observation.
- Conditions
- Abdominal Aortic Aneurysm
- Being tested
- Abdominal Aortic Aneurysm Stent Graft System
- Keywords
- Abdominal Aortic Aneurysm Stent Graft System
- Medical subject headings
- Aortic Aneurysm, Abdominal
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Abdominal Aortic Aneurysm Stent Graft SystemDevice
Abdominal aortic bifurcation stent and iliac artery extension stent were preloaded into abdominal aortic bifurcation stent transporter and iliac artery extension stent transporter, respectively. In the operation, the abdominal aorta bifurcation stent and the iliac artery extension stent will be delivered to the corresponding lesion position of the abdominal iliac artery and release. The abdominal aortic bifurcation stent and the iliac artery extension stent will form a whole through docking and thereby reducing the risk of rupture of an infrarenal abdominal aortic aneurysm due to the shock of blood flow.
| Study group | Role | What they receive |
|---|---|---|
| Intervention arm | Experimental | Participants will be treated with Abdominal Aortic Aneurysm Stent Graft System Receives: Device: Abdominal Aortic Aneurysm Stent Graft System |
What is being measured
The primary outcome is the main question the study is designed to answer.
The success rate of abdominal aortic aneurysm treatment
A successful abdominal aortic aneurysm treatment is a composite index and refers to the following criteria simultaneously:
- the immediate technical success (the immediate technical success refers to the delivery system is successfully delivered to a predetermined location, the abdominal aortic stent is successfully deployed, and the transporter can be safely withdrawn from the body).
- the increase of maximum diameter of abdominal aortic aneurysm at the 12th month after surgery ≤5mm, compared with that before surgery.
- The displacement of anterior abdominal aortic stent was no more than 10mm at the 12th month after the operation from the location before discharge.
- No type I or type III leakage requiring additional intervention occurred 12 months after surgery。 No abdominal aortic aneurysm rupture within 12 months after surgery.
Measured: 12 months after operation
Secondary outcomes (10)
The incidence of Major Adverse Event (MAE)
Major Adverse Event (MAE) is defined as all-cause death, myocardial infarction, renal failure, respiratory failure, paraplegia, stroke, and intestinal ischemia.
Measured: 30 days after surgery
Incidence of type I or III leakage
Type I leakage is also known as peripheral leakage or graft related leakage, which refers to internal leakage resulting from the inability of stent-type blood vessels to adhere closely to an autologous blood vessel, and the blood flow continues to flow into the aneurysm cavity, including proximal type I and distal type I leakage. Type III leakage refers to leakage caused by the failure of stent-type vessels to bind themselves tightly or the rupture of artificial vessels, and the blood flow continues to flow into the aneurysm cavity.
Measured: 6 months, 12 months after surgery
The incidence of abdominal aortic stent displacement
The displacement refers to the position of abdominal aorta stents of postoperative follow-up are displaced more than 10 mm from the before discharge position.
Measured: 6 months, 12 months after surgery
Operation efficacy - incidence of conversion from abdominal aortic aneurysm treatment to open surgery or secondary surgery
The incidence of conversion from abdominal aortic aneurysm treatment to open surgery or secondary surgery intervention.
Measured: 6 months, 12 months and 2-5 years after surgery.
The incidence rate of perioperative delivery related complications
Perioperative period refers to intraoperative time to 30 days postoperative. Delivery related complications incidence including he transabdominal surgery caused by intraoperative conveyors, the hemorrhage in the middle iliac artery, the hemorrhage in the femoral artery at the puncture site, the hematoma and the pseudoaneurysm.
Measured: intraoperative and postoperative 30 days.
The incidence of Acute lower limb ischemia.
The incidence of acute lower limb ischemia.
Measured: Before discharge and 30 days after surgery
All-cause mortality
All-cause mortality evaluates at 6 months, 12 months and 2-5 years after surgery
Measured: 6 months, 12 months and 2-5 years after surgery
Disease related mortality
Abdominal aortic aneurysm-related mortality evaluates at 6 months, 12 months and 2-5 years after surgery.
Measured: 6 months, 12 months and 2-5 years after surgery
Severe adverse events (SAE)
The incidence of severe adverse events (SAE). According to the ISO 14155 SAE refers to
- led to death,
- led to serious deterioration in the health of the subject, that either resulted in
- a life-threatening illness or injury, or
- a permanent impairment of a body structure or a body function, or
- in-patient or prolonged hospitalization, or
- medical or surgical intervention to prevent life-threatening illness or injury or permanent impairment to a body structure or a body function,
- led to foetal distress, foetal death or a congenital abnormality or birth defect
Measured: 6 months, 12 months and 2-5 years after surgery
Device-related adverse effects (AE)
The incidence of the device-related adverse effects (AE), according to the ISO14155, adverse device effect that has resulted in any of the consequences characteristic of a serious adverse event.
Measured: 6 months, 12 months and 2-5 years after surgery
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted27 Sep 2018
- Study start30 Sep 2018
- Primary completion30 Nov 2020 (estimated)
- Study completion31 Mar 2025 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Abdominal Aortic AneurysmStudies of the same condition, open and under way.
- More trials run by Lifetech Scientific (Shenzhen) Co., Ltd.The sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 156 participants (actual)
Sponsor and investigators
- Lead sponsor
- Lifetech Scientific (Shenzhen) Co., Ltd.
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Wei Guo, Professor, Principal investigator, Chinese PLA General Hospita
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03687489
- Sponsor's protocol ID
- LTAAA-01
- Status last verified
- Dec 2019
- First submitted
- 25 Sep 2018
- Last updated
- 30 Dec 2019
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
Study at a glance
From the registry record, last updated by the sponsor on 30 Dec 2019. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Safety and Efficacy Study of Abdominal Aortic Aneurysm Stent Graft System for Infrarenal Abdominal Aortic Aneurysm: A Prospective, Multi-center, Objective Performance Criteria Clinical Trial
- ClinicalTrials.gov ID
- NCT03687489
- Acronym / sponsor ID
- LTAAA-01
- Conditions
- Abdominal Aortic Aneurysm
- Keywords
- Abdominal Aortic Aneurysm Stent Graft System
- Study type
- Interventional
- Recruitment status
- Unknown status
- Enrolment
- 156 participants (actual)
- Lead sponsor
- Lifetech Scientific (Shenzhen) Co., Ltd.Industry (pharma, biotech, devices)
- Study start
- 30 Sep 2018 (actual)
- Primary completion
- 30 Nov 2020 (estimated)
- Study completion
- 31 Mar 2025 (estimated)
- First posted
- 27 Sep 2018 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
A prospective, multi-centre, objective performance criteria clinical trial to evaluate the safety and efficacy of Abdominal Aortic Aneurysm Stent Graft System manufactured by Lifetech Scientific (Shenzhen) Co., LTD. for the infrarenal abdominal aortic aneurysm.
Detailed description
This clinical trial was conducted in a qualified clinical trial institution. Investigators will use Abdominal Aortic Aneurysm Stent Graft System manufactured by Lifetech Scientific (Shenzhen) Co., LTD. to treat patients with Infrarenal Abdominal Aortic Aneurysm. This is a Prospective, Multi-center, Objective Performance Criteria Clinical Trial. It is expected to submit to the ethics committee of the lead unit for review in March 2018, and complete the implantation of 156 patients in 22 centres nationwide within 12 months, and interim follow-up was conducted before discharge, 30 days after surgery, 6 months after surgery and 12 months after surgery, long-term follow-up will be performed at 24 months postoperatively, 36 months postoperatively, 48 months postoperatively and 60 months postoperatively.
This trial will evaluate whether the device reached the primary safety endpoint and primary efficacy endpoint through two primary endpoint indicators: the incidence of major adverse events (MAE) within 30 days and the success rate of abdominal aortic aneurysm treatment 12 months after surgery. This trail will evaluate whether the device reached the secondary safety endpoint and primary efficacy endpoint through several secondary endpoint indicators: Perioperative (intraoperative to postoperative 30 days) delivery related complications incidence rate (including the transabdominal surgery caused by intraoperative conveyors, the hemorrhage in the middle iliac artery, the hemorrhage in the femoral artery at the puncture site, the hematoma and the pseudoaneurysm), the incidence of acute lower limb ischemia before discharge and 30 days after surgery, all-cause mortality at 6 months, 12 months and 2-5 years after surgery, abdominal aortic aneurysm-related mortality at 6 months, 12 months and 2-5 years after surgery, the incidence of severe adverse events (SAE) at 6 months, 12 months and 2-5 years after surgery, the incidence of the device-related adverse events (AE) at 6 months, 12 months and 2-5 years after surgery, the incidence of type I or type III leakage at 6 months, 12 months after surgery, the incidence of displacement of Abdominal Aortic Aneurysm Stent at 6 months, 12 months after surgery and the incidence of conversion from abdominal aortic aneurysm treatment to open surgery or secondary surgery intervention at 6 months, 12 months and 2-5 years after surgery. According to the guidelines for clinical trials of aortic stent system, the sponsor will apply for CFDA listing registration after completing a 12-month primary endpoint assessment. According to the guidelines for clinical trials of aortic covered stent system, the sponsor will apply for CFDA listing registration after completing a 12-month primary endpoint assessment, and annually follow-up will be conducted until the fifth year for the long-term efficacy observation.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Intervention arm | Experimental | Device: Abdominal Aortic Aneurysm Stent Graft SystemParticipants will be treated with Abdominal Aortic Aneurysm Stent Graft System |
Who may qualify
- Ages
- 18 to 85 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (10 listed)
- 1. Patients aged greater than 18 years old and less than 85 years old, regardless of gender.
- 2. Patients who can understand the purpose of the trial, voluntarily participate in and sign the informed consent, and are willing to complete the follow-up according to the requirements of the protocol.
- 3. Patients diagnosed with Infrarenal Abdominal Aortic Aneurysm and should meet at least one of the following conditions:
- 5. The length of the proximal aneurysm neck of abdominal aortic aneurysm≥10mm, and the angle of the proximal aneurysm neck ≤75 °.
- 6. The range of the diameter of the iliac artery anchoring area is between 8mm to 22mm.
Key exclusion criteria (15 listed)
- 1. Patients with severe stenosis, calcification, or mural thrombus in the anchoring area of the stent and easily lead to incomplete stent apposition.
- 2. Patients with rupture of an abdominal aortic aneurysm or threatened rupture.
- 3. Patients with abdominal aortic dissection.
- 4. Patients with mycotic or infectious abdominal aortic aneurysms.
- 5. Patients with a history of myocardial infarction or unstable angina pectoris for 6 months. Characteristics of unstable angina pectoris: angina symptoms gradually increased, new onset of rest or night angina pectoris or occurrence of angina prolonged.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Abdominal Aortic Aneurysm Stent Graft SystemAbdominal aortic bifurcation stent and iliac artery extension stent were preloaded into abdominal aortic bifurcation stent transporter and iliac artery extension stent transporter, respectively. In the operation, the abdominal aorta bifurcation stent and the iliac artery extension stent will be delivered to the corresponding lesion position of the abdominal iliac artery and release. The abdominal aortic bifurcation stent and the iliac artery extension stent will form a whole through docking and thereby reducing the risk of rupture of an infrarenal abdominal aortic aneurysm due to the shock of blood flow. | Device | Intervention arm |
Primary outcome
The success rate of abdominal aortic aneurysm treatment
Time frame: 12 months after operation
A successful abdominal aortic aneurysm treatment is a composite index and refers to the following criteria simultaneously: 1. the immediate technical success (the immediate technical success refers to the delivery system is successfully delivered to a predetermined location, the abdominal aortic stent is successfully deployed, and the transporter can be safely withdrawn from the body). 2. the increase of maximum diameter of abdominal aortic aneurysm at the 12th month after surgery ≤5mm, compared with that before surgery. 3. The displacement of anterior abdominal aortic stent was no more than 10mm at the 12th month after the operation from the location before discharge. 4. No type I or type III leakage requiring additional intervention occurred 12 months after surgery。 No abdominal aortic aneurysm rupture within 12 months after surgery.
10 secondary outcomes
The incidence of Major Adverse Event (MAE)
Time frame: 30 days after surgery
Incidence of type I or III leakage
Time frame: 6 months, 12 months after surgery
The incidence of abdominal aortic stent displacement
Time frame: 6 months, 12 months after surgery
Operation efficacy - incidence of conversion from abdominal aortic aneurysm treatment to open surgery or secondary surgery
Time frame: 6 months, 12 months and 2-5 years after surgery.
The incidence rate of perioperative delivery related complications
Time frame: intraoperative and postoperative 30 days.
The incidence of Acute lower limb ischemia.
Time frame: Before discharge and 30 days after surgery
All-cause mortality
Time frame: 6 months, 12 months and 2-5 years after surgery
Disease related mortality
Time frame: 6 months, 12 months and 2-5 years after surgery
Severe adverse events (SAE)
Time frame: 6 months, 12 months and 2-5 years after surgery
Device-related adverse effects (AE)
Time frame: 6 months, 12 months and 2-5 years after surgery
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 30 Dec 2019.
Related trials for Abdominal Aortic Aneurysm
Not yet recruitingObservational study
Pilot Study on the Effectiveness and Safety of OPTILENE® SILVER MESH ELASTIC in Prevention of Surgical Site Infection (SSI) and Incisional Hernia (IH)
Abdominal Aortic Aneurysm, Morbid Obesity
RecruitingPhase 4
Effect of Remimazolam Versus Propofol Total Intravenous Anesthesia on Intraoperative Hemodynamic Stability in Patients Undergoing Thoracic or Abdominal Endovascular Aortic Repair
Aortic Aneurysm, Thoracoabdominal, Aortic Aneurysm, Abdominal
Not yet recruitingObservational study
Aortic Size and Height Indices in Abdominal Aortic Aneurysms
Abdominal Aortic Aneurysm, Abdominal Aortic Aneurysm, Ruptured
Not yet recruitingObservational study
Real-World Data Collection of GORE Devices Used In the Endovascular Treatment of Aortic Aneurysms Which Incorporate Visceral Arteries.
Complex Aortic Aneurysms, Thoracoabdominal Aneurysm
Enrolling by invitation
Endovascular Treatment of Thoracic Aortic Disease
Thoracic Aortic Aneurysms, Dissecting, Aneurysm
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Wei Guo, Professor principal investigator
Chinese PLA General Hospita
22 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Abdominal Aortic Aneurysm Stent Graft System in people with Abdominal Aortic Aneurysm, run by Lifetech Scientific (Shenzhen) Co., Ltd. at 22 sites in China.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 10 inclusion and 15 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 30 Dec 2019. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 22 sites in China. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
The success rate of abdominal aortic aneurysm treatment (time frame: 12 months after operation). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 30 Dec 2019.