External Ventricular DrainNCT03696043

External Ventricular Drain Placement Stealth Study

A study testing Axium Steatlh Image Guidance and EVD placement in people with External Ventricular Drain and Intracranial Pressure, run by University of Wisconsin, Madison at 1 site in United States.

Terminated

Stopped early. The study ended before it was planned to and will not resume.

Official record
Search all trials

Trial summary

External ventricular drain (EVD) placement is performed very often in neurosurgical practices. EVD's are most commonly placed at the bedside using external anatomical landmarks to guide the catheter into the frontal horn of the ipsilateral lateral ventricle. Read more about this study

Who is it for?
Ages 18 to 88 years
What is being tested?
Axium Steatlh Image Guidance and EVD placement
Could I receive a placebo?
No, everyone receives an active treatment
How many people
31 participants
Where
1 siteUnited States
Study dates
15 Aug 2018to 12 Mar 2026
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 88 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients undergoing bedside external ventricular drain placement determined by attending physician
  • Age ≥ 18 years and ≤ 88 years
  • Male or Female
  • Patients or consentable family member must sign a written informed consent prior to EVD placement
  • Stealth compatible head CT or MRI

Who cannot join

  • Patients ≤ 18 and ≥ 88 years of age
  • Prisoner status
  • Subjects who decline participation into the study
  • Subjects determined to be medically or neurologically to high of a risk for the study, determined by attending physician
  • Patients who undergo emergent EVD placement via emergency consent
  • Subjects for whom self-consent or consent by a LAR cannot be obtained or cannot be obtained
  • Pregnant women
  • Non-English speaking patients

Trial locations and contacts

1 site in 1 country.

United States1 site
  • University of Wisconsin-Madison

    Madison, Wisconsin, 53792

Other trials in United States

About this study

Official title: Application of Image Guidance Technology to Bedside External Ventricular Drain Placement

External ventricular drain (EVD) placement is performed very often in neurosurgical practices. EVD's are most commonly placed at the bedside using external anatomical landmarks to guide the catheter into the frontal horn of the ipsilateral lateral ventricle. EVDs are often placed due to acute neurological compromise and require timely insertion.

Accurate catheter placement is essential to achieving effective external CSF drainage without complications or occlusion/failure of the catheter. Catheter placement is most commonly performed via a freehand approach using external anatomical landmarks to help identify the location of the lateral ventricle within the brain without the aid of imaging. Proper identification of the ventricles on pre-procedure imaging, surgeon skill, and estimation of pathologic perturbations to the normal location of the ventricles all factor into the success of catheter placement. Multiple passes are often required. The accuracy rate from the freehand technique has been reported to range from 40 to 98 percent.

Read more

Current methods for EVD placement do not compensate for superficial brain vessels or pathology that may alter the intracranial anatomy such as trauma, hemorrhage, or mass lesions. Some studies have attempted to use CTA imaging to identify intracranial vessels in an attempt to avoid them during placement.

Image guidance is a tool used very commonly for placement of EVD's and shunts in the operating room. AxiEM Stealth is a noninvasive image localization modality that registers a CT or MRI to the individual patients facial and scalp anatomy.

This study will compare the current standard of care of freehand placement of bedside external ventricular catheters to the placement of EVD catheters with AxiEM Stealth image guidance.

Read the detailed description

External ventricular drain (EVD) placement is performed very often in neurosurgical practices. EVD's are used most commonly to monitor intracranial pressure and divert cerebrospinal fluid (CSF) in patients with increased intracranial pressures. Pathologies where EVDs are most frequently needed include hydrocephalus, malignancy, and/or trauma. EVD's are most commonly placed at the bedside using external anatomical landmarks to guide the catheter into the frontal horn of the ipsilateral lateral ventricle. EVDs are often placed due to acute neurological compromise and require timely insertion. This can increase the associated risk and result in complications.

Accurate catheter placement is essential to achieving effective external CSF drainage without complications or occlusion/failure of the catheter. Catheter placement is most commonly performed via a freehand approach using external anatomical landmarks to help identify the location of the lateral ventricle within the brain without the aid of imaging. Proper identification of the ventricles on pre-procedure imaging, surgeon skill, and estimation of pathologic perturbations to the normal location of the ventricles all factor into the success of catheter placement. Multiple passes are often required. The accuracy rate from the freehand technique has been reported to range from 40 to 98 percent. A very basic grading scale has been developed to assess placement but does not include items such as the number of passes until successful placement and presence of post placement hemorrhage or other neurological complications. An increased number of passes increases the risk of post placement hemorrhage and may damage the brain. Hemorrhage has been reported to occur after catheter placement at rates ranging from 0.2 to 41 percent.

Current methods for EVD placement do not compensate for superficial brain vessels or pathology that may alter the intracranial anatomy such as trauma, hemorrhage, or mass lesions. Some studies have attempted to use CTA imaging to identify intracranial vessels in an attempt to avoid them during placement.

Image guidance is a tool used very commonly for placement of EVD's and shunts in the operating room. AxiEM Stealth is a noninvasive image localization modality that registers a CT or MRI to the individual patients facial and scalp anatomy. A probe can then be used to identify, in real-time, the underlying anatomy and trajectories. This imaging guidance may improve the accuracy of EVD placement.

This study will compare the current standard of care of freehand placement of bedside external ventricular catheters to the placement of EVD catheters with AxiEM Stealth image guidance. Accuracy of the tip of the catheter, occurrence of post-placement hemorrhage, the number of passes required for CSF flow, ventricle diameter, catheter clogging/failure, time required for placement, patient demographics and other secondary outcome measures such as Glasgow Outcome Scale (GOS) and Modified Rankin Score (MRS) will be collected. The hypothesis is that image guided EVD catheter placement will improve accuracy, decrease the number of brain transgressions, and decrease complications of EVD placement.

What makes up an external ventricular drain and how does it work? An external ventricular drain (EVD) is comprised of a catheter, drainage tubing, and a collection system. Once the catheter is in the ventricular system, it works by measuring the intracranial pressure via a transducer and drains excess CSF from the ventricular system to ensure pressures does not exceed a set threshold. Normal intracranial pressures range from about 5-20 mmHg and are usually around 10mmHg. The EVD system can be set at a certain level and when the intracranial pressures rise above that level, CSF drains out the catheter into the collecting system. The EVD system can be raised or lowered to create different intracranial pressure thresholds and keep intracranial pressures controlled in patients that have a pathology, such as cerebral swelling or ventricular obstruction, leading to increased pressures.

What is the current technique used to place an EVD? A sterile field is prepared about 10-12 centimeters posterior to the eye (either right or left as clinically indicated) and about 2-3 cm lateral to the midline of the skull. This point should be about 1 cm anterior to the coronal suture. An incision is made at this point and a burr hole is created using a hand drill. The EVD catheter is prepared using a stylet to help with movement through the brain parenchyma. The catheter is advanced in a trajectory perpendicular to the skull, which results in a direction that is towards the ipsilateral medial canthus and ipsilateral tragus which are other landmarks that can be used. The catheter is advanced to 5-6 cm and the stylet is removed to assess for CSF flow. If CSF flow is not appreciated, then the catheter is passed softly for about 1 more centimeter. If CSF flow is still not appreciated, the catheter is removed and the stylet replaced for another attempt. If unsuccessful after 3 attempts, the catheter can be left in place and a head CT can be done to assess the adjustments that need to be made. This can often take up to 10 passes or more if there is significant brain shift due to mass effect or aberrant anatomy. Once CSF flow is obtained, the catheter is tunneled posteriorly and anchored to the skin with a stitch. The incision is then closed and the catheter is connected to the drainage tubing of the collection system. The presence of CSF drainage is checked at multiple points during closure to ensure that the catheter remains in good position.

How does Axiem Stealth work as an image guidance system and how is it used for EVD placement? The first step for using the image guidance system is to upload the most recent (since admission or within 6 hours from bleeding) head CT or MRI into the Stealth station that has been obtained since admission. The Axiem Stealth imaging guidance system uses a probe (AxiEM Registration Probe) and a side mount emitter (AxiEM Side Mount Emitter) to register the patient's head in relation to the probe. A trajectory (entry point and target) is then planned. This registration process takes an estimated 5-15 minutes to perform. A separate stylet (StealthStation EM Stylet) is designed specifically for the catheter and slides down the center of the catheter. A burr-hole is created at the predefined precise location and the catheter is passed to the target under electromagnetic guidance.

Relevance of this research:

The novelty of this study is to investigate whether using image guidance technology can improve EVD catheter placement. Image guidance is used very commonly for EVD and shunt placement in the operating room with excellent accuracy and precision. The hypothesis is that using this same workflow at the bedside will improve accuracy; decrease the number of passes needed for a successful placement, decrease the number of post-placement hemorrhagic events, and help improve the effectiveness of the catheter as well as patient outcomes.

Being tested
Axium Steatlh Image Guidance, EVD placement
Keywords
intracranial pressure, external ventricular drain, cerebrospinal fluid

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Axium Steatlh Image GuidanceOther

    The Axiem Stealth imaging guidance system uses a probe (AxiEM Registration Probe) and a side mount emitter (AxiEM Side Mount Emitter) to register the patient's head in relation to the probe. A trajectory (entry point and target) is then planned. This registration process takes an estimated 5-15 minutes to perform. A separate stylet (StealthStation EM Stylet) is designed specifically for the catheter and slides down the center of the catheter. A burr-hole is created at the predefined precise location and the catheter is passed to the target under electromagnetic guidance.

  • EVD placementOther

    A sterile field is prepared about 10-12 centimeters posterior to the eye and about 2-3 cm lateral to the midline of the skull. An incision is made at this point and a burr hole is created using a hand drill. The catheter is advanced in a trajectory perpendicular to the skull, which results in a direction that is towards the ipsilateral medial canthus and ipsilateral tragus which are other landmarks that can be used.

Study groups in NCT03696043
Study groupRoleWhat they receive
EVD placementActive comparatorCatheter placement is most commonly performed via a freehand approach using external anatomical landmarks to help identify the location of the lateral ventricle within the brain without the aid of imaging. Proper identification of the ventricles on pre-procedure imaging, surgeon skill, and estimation of pathologic perturbations to the normal location of the ventricles all factor into the success of catheter placement. Multiple passes are often required. The accuracy rate from the freehand technique has been reported to range from 40 to 98 percent.
Receives: Other: EVD placement
Axium Stealth Image GuidanceExperimentalThe novelty of this study is to investigate whether using image guidance technology can improve EVD catheter placement. Image guidance is used very commonly for EVD and shunt placement in the operating room with excellent accuracy and precision. We hypothesize that using this same workflow at the bedside will improve accuracy; decrease the number of passes needed for a successful placement, decrease the number of post-placement hemorrhagic events, and help improve the effectiveness of the catheter as well as patient outcomes.
Receives: Other: Axium Steatlh Image Guidance; Other: EVD placement

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of catheter passes or attempts

    Collection of number of passes needed for successful catheter placement

    Measured: baseline

  2. Accuracy of catheter tip compared to foramen of Monro

    Measurement of accuracy for catheter tip compared to foramen of Monro with accuracy formula

    Measured: baseline

Secondary outcomes (5)
  1. Occurrence of post-placement hemorrhage

    Anotation of occurrence of hemorrhage post-catheter placement by either freehand or image guided

    Measured: baseline and 12 months

  2. New neurological deficits

    Utilization of the Glasgow Come Score and mRS scale to measure new neurological symptoms

    Measured: baseline and 12 months

  3. Durability of EVD

    Presence of clogging/ failure

    Measured: baseline and 12 months

  4. Time required catheter insertion

    Anotation of time allocation for catheter insertion - both methods

    Measured: baseline

  5. Infection rate

    Occurrence of ventriculostomy infection (meningitis, ventriculitis, cerebritis)

    Measured: baseline and 12 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted4 Oct 2018
  2. Study start15 Aug 2018
  3. Primary completion12 Mar 2026
  4. Study completion12 Mar 2026

Why it stopped: slow accrual

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Non-randomised
Intervention model
Parallel groups
Model description
Target of 100 participants - 50% freehand EVD placement and 50% image guided EVD placement. Randomization is every other patient will received image guided EVD placement
Masking
Single blind
Who is masked
Participant
Enrolment
31 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03696043
Sponsor's protocol ID
2017-1487
Other IDs
A535700, SMPH/NEURO SURG/NEURO SURG, Protocol Version 8/8/2024
Status last verified
Mar 2026
First submitted
24 May 2018
Last updated
16 Mar 2026
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Patil V, Lacson R, Vosburgh KG, Wong JM, Prevedello L, Andriole K, Mukundan S, Popp AJ, Khorasani R. Factors associated with external ventricular drain placement accuracy: data from an electronic health record repository. Acta Neurochir (Wien). 2013 Sep;155(9):1773-9. doi: 10.1007/s00701-013-1769-y. Epub 2013 May 23.

    PubMed 23700258
  • Mahan M, Spetzler RF, Nakaji P. Electromagnetic stereotactic navigation for external ventricular drain placement in the intensive care unit. J Clin Neurosci. 2013 Dec;20(12):1718-22. doi: 10.1016/j.jocn.2013.03.005. Epub 2013 Aug 30.

    PubMed 23993898
  • Patil V, Gupta R, San Jose Estepar R, Lacson R, Cheung A, Wong JM, Popp AJ, Golby A, Ogilvy C, Vosburgh KG. Smart stylet: the development and use of a bedside external ventricular drain image-guidance system. Stereotact Funct Neurosurg. 2015;93(1):50-8. doi: 10.1159/000368906. Epub 2015 Jan 31.

    PubMed 25662506
  • Sarrafzadeh A, Smoll N, Schaller K. Guided (VENTRI-GUIDE) versus freehand ventriculostomy: study protocol for a randomized controlled trial. Trials. 2014 Dec 5;15:478. doi: 10.1186/1745-6215-15-478.

    PubMed 25480528
  • Robertson FC, Abd-El-Barr MM, Mukundan S Jr, Gormley WB. Ventriculostomy-associated hemorrhage: a risk assessment by radiographic simulation. J Neurosurg. 2017 Sep;127(3):532-536. doi: 10.3171/2016.8.JNS16538. Epub 2016 Dec 2.

    PubMed 27911234
  • Alan N, Lee P, Ozpinar A, Gross BA, Jankowitz BT. Robotic Stereotactic Assistance (ROSA) Utilization for Minimally Invasive Placement of Intraparenchymal Hematoma and Intraventricular Catheters. World Neurosurg. 2017 Dec;108:996.e7-996.e10. doi: 10.1016/j.wneu.2017.09.027. Epub 2017 Sep 14.

    PubMed 28919568
  • Wang A, Tenner MS, Tobias ME, Mohan A, Kim D, Tandon A. A Novel Approach Using Electromagnetic Neuronavigation and a Flexible Neuroendoscope for Placement of Ommaya Reservoirs. World Neurosurg. 2016 Dec;96:195-201. doi: 10.1016/j.wneu.2016.08.127. Epub 2016 Sep 5.

    PubMed 27609447

Questions about this trial

What is this clinical trial studying?

A study testing Axium Steatlh Image Guidance and EVD placement in people with External Ventricular Drain and Intracranial Pressure, run by University of Wisconsin, Madison at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: stopped early, as of the sponsor's last update on 16 Mar 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study was stopped early (reason given: slow accrual). Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Number of catheter passes or attempts (time frame: baseline). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03696043, which also lists 7 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 16 Mar 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in