AzTrials
AzTrials

Aortic Arch; Aneurysm, DissectingNCT03735472

Study of the Thoraflex™ Hybrid Device for the Treatment of Aneurysm/Dissection of the Descending Thoracic Aorta

An observational study of Aortic Arch; Aneurysm, Dissecting, run by Vascutek Ltd. at 37 sites in France.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record

Search all trials

Trial summary

The purpose of this national observational study is to evaluate the Thoraflex™ Hybrid vascular prosthesis in the replacement of the aortic arch and the treatment of aneurysm/dissection of the descending thoracic aorta in relation to morbidity-mortality, visceral malperfusions, neurological and renal complications… Read more about this study

Who is it for?
Any age
Conditions the study is for
Aortic Arch; Aneurysm, Dissecting
What is being tested?
Thoraflex™ Hybrid
Type of treatment
Medical device
How many people
351 participants
Where
37 sitesFrance
Study dates
Apr 2016to Nov 2024
Phase
Observational

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Study population: Any patient presenting an aneurysm/dissection of the thoracic aorta of the aortic arch and/or the descending thoracic aorta and necessitating surgery of the Elephant Trunk type. To meet the requirements of the French National Authority for Health, this study will include all the patients treated with the Thoraflex™ Hybrid hybrid vascular prosthesis. Any surgeon practising in France and wishing to inplant a Thoraflex™ Hybrid hybrid vascular prosthesis will be available from the coordinating observer.

Who may be able to join

  • Patient presenting an aneurysm/dissection of the thoracic aorta of the aortic arch and/or the descending thoracic aorta, and necessitating a procedure of the "Elephant Trunk" type, with the Thoraflex™ Hybrid hybrid vascular prosthesis.

Who cannot join

  • Patient having refused to sign the Consent form to the use of his/her data.
  • Patient residing abroad, for whom follow-up is not possible.
  • Patient with active endocarditis
  • Patient who has received a post-infarction septal repair.
  • A list of all of the patients who have received the Thoraflex™ Hybrid hybrid vascular prosthesis but not participating in the observational study will be documented, as well as the reasons for non-inclusion

Trial locations and contacts

37 sites in 1 country.

37 sites in 1 country

France37 sites
  • Centre Hospitalier University (University Hospital centre)

    Amiens

  • CHU Angers

    Angers

  • CH De La Region D Annecy

    Annecy

  • CHU-Hopital Jean Minjoz

    Besançon

  • Hopital Cardio-Vasculaire Louise Pradel

    Bron

  • CHU Cote De Nacre

    Caen

  • CHU - Hopital Gabriel Montpied

    Clermont-Ferrand

  • CHU Hopital Henri Mondor

    Créteil

  • CHU - Hopital Du Bocage

    Dijon

  • CHU Hopital A. Michallon

    Grenoble

  • Centre Chirurgical Marie Lannelongue

    Le Plessis-Robinson

  • CHRU Lille

    Lille

  • Clinique De La Sauvegarde

    Lyon

  • CHU Hopital La Timone

    Marseille

  • Hopital Clinique Claude Bernard

    Metz

  • Hopital De Mercy

    Metz

  • CHU Hopital Arnaud De Villeneuve

    Montpellier

  • CHU - Hopital Brabois

    Nancy

  • CHU - Hopital Guillaume et Rene Laenec

    Nantes

  • Hopital Prive Les Franciscaines

    Nîmes

  • Groupe Hospitalier Pitié-Salpêtrière, Vascular Surgery Department

    Paris, 75013

  • Groupe Hospitalier La Pitie Salpetriere

    Paris

  • Hopital Bichat

    Paris

  • Hopital Europeen Georges Pompidou

    Paris

  • Institut Mutualiste Montsouris

    Paris

  • CHU - Hopital Haut Leveque

    Pessac

  • CHU - Hopital Robert Debre

    Reims

  • CHU - Hopital Pontchaillou

    Rennes

  • CHU Charles Nicolle

    Rouen

  • Centre Cardiologique Du Nord

    Saint-Denis

  • CH Felix Guyon

    Saint-Denis

  • CHU De Saint Etienne

    Saint-Etienne

  • Hopitaux Universitaires - Nouvel Hopital Civil

    Strasbourg

  • Hôpital Rangueil, Cardiothoracic Surgery Department

    Toulouse, 31009

  • Clinique Pasteur

    Toulouse

  • CHU De Tours

    Tours

  • Clinique Du Tonkin - Medipole

    Villeurbanne

Other trials in France

About this study

Official title: National Observational Study of the Thoraflex™ Hybrid Vascular Prosthesis in the Replacement of the Aortic Arch and the Treatment of Aneurysm/Dissection of the Descending Thoracic Aorta

The purpose of this national observational study is to evaluate the Thoraflex™ Hybrid vascular prosthesis in the replacement of the aortic arch and the treatment of aneurysm/dissection of the descending thoracic aorta in relation to morbidity-mortality, visceral malperfusions, neurological and renal complications, endoleak and evolution of the aortic thoracic stent over time.

Read the detailed description

Quality control will be performed continuously at various stages of the error correction process, according to the sponsor's Standard Operating Procedures.

Systematic coherence control procedures will be implemented and documented. The correction procedures will be tracked. For the study data, requests (Queries) will be issued and transmitted to the various centres for resolution.

To ensure data quality, a Monitoring Plan will be implemented. This plan will detail the frequency of visits or check-ups and the proportion of the data verified. It is expected that at least 10% of the data will be verified.

The monitoring factors in relation to the quality of electronic case report form completion will be performed by one of the Clinical Research Associates.

The participating physicians will be automatically contacted in the event of the absence of data entry after inclusion of patients and/or dates of scheduled visits and planned controls.

All of the analyses will be managed by the Direction de la Recherche Clinique et de l'Innovation of CHU Amiens. The statistical analysis software to be used is SAS (version 9.1). According to the target population, a sample of approximately 80 to 100 patients is anticipated, which would enable accuracy of ± 8.5 to 9.5% for an estimation of an event rate of around 25%.

During implementation of the study, the observers will be asked to minimise any missing data. The data collected is comparable to usual practice, which should be available from the original medical record. However, in the event of absence of the latter, the note missing data will be added to the data collection form. Several measures will be taken to avoid patients being lost to follow-up.

The study documents provided to the observers for initiation emphasise the fundamental importance of patient follow-up and the collection of data during the entire study. If necessary, scientific societies as well as the French National Authority of Health (HAS) may remind the observers of their obligation to actively participate in the existing national observational study.

The observer will obtain the means to contact the patient, his/her General Practitioner or close friend/next of kin.

Demographic and medical data of patients and follow-up descriptive data will be reflected in the patient population included.

Qualitative parameters are described by their frequency distribution and related bilateral 95% confidence intervals, quantitative parameters by their average, standard deviation minimum, maximum, median and quartiles, number of missing values.

Each of the rates corresponding to the study criteria is analysed by calculating the frequencies of distribution and related bilateral 95% confidence intervals (95% CI).

The rate of events over time will be described by a survival curve using the Kaplan Meier method and the related Kaplan Meier estimators will be calculated.

On an exploratory basis, the criteria in the study will also be analysed according to the basic characteristics of the patients:

  • Age (in categories)
  • Sex
  • Indications.
Being tested
Thoraflex™ Hybrid
Medical subject headings
Aneurysm

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Thoraflex™ HybridDevice

    The Thoraflex™ Hybrid device is particularly suited to the treatment of extended lesions of the ascending aorta, the aortic arch and the descending aorta, which constitute a major challenge in cardiovascular surgery.

    It enables, during a single surgical operation, combination of the "Frozen Elephant Trunk" technique and a 4-branch prosthesis of the aortic arch, thus enhancing the arsenal of the surgeon in the treatment of complex diseases of the aortic arch.

Study groups in NCT03735472
Study groupRoleWhat they receive
Aneurysm/DissectionThoraflex™ Hybrid
Receives: Device: Thoraflex™ Hybrid

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Patients who did not die, nor suffered paraplegia due to the prosthesis, nor had complications linked to the procedure and surgical conversion

    Percentage of patients who did not die, nor suffered paraplegia due to the prosthesis, nor had complications linked to the procedure and surgical conversion for 30 days post-operative

    Measured: 30 days post-operative

Secondary outcomes (6)
  1. Technical success

    is defined as the placement and deployment of the a Vascutek Thoraflex™ Hybrid Device in the absence of mortality, conversion to conventional open surgical repair, failed patency, evidence of an unanticipated distal type I or type III endoleak on pre-discharge CT scan

    Measured: Within 30 days of intervention; Between 3 and 6 months; then documented by the patient's clinical course up to 3 years.

  2. Death

    Death linked to the device, to the procedure, all causes

    Measured: Within 30 days of intervention; Between 3 and 6 months; then documented by the patient's clinical course up to 3 years.

  3. Transitory paraplegia/Para-paresis

    Transitory paraplegia/Para-paresis

    Measured: Within 30 days of intervention; Between 3 and 6 months; then documented by the patient's clinical course up to 3 years.

  4. Follow-up surgery

    Follow-up Surgery linked/not linked to the device

    Measured: Within 30 days of intervention; Between 3 and 6 months; then documented by the patient's clinical course up to 3 years.

  5. Complications linked to the device

    No plication, torsion, occlusion and thrombosis of the device, Leak-tightness of the polyester prosthesis, Change over time of the thoracic stent graft

    Measured: Within 30 days of intervention; Between 3 and 6 months; then documented by the patient's clinical course up to 3 years.

  6. Rates of visceral malperfusion, neurological, renal, cardiac, respiratory and Haemorrhagic complications

    Rates of visceral malperfusion, neurological, renal, cardiac, respiratory and Haemorrhagic complications

    Measured: Within 30 days of intervention; Between 3 and 6 months; then documented by the patient's clinical course up to 3 years.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted8 Nov 2018
  2. Study startApr 2016
  3. Primary completionMay 2019
  4. Study completionNov 2024

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
351 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03735472
Sponsor's protocol ID
EPI-Flex
Status last verified
Nov 2024
First submitted
16 Dec 2015
Last updated
19 Feb 2025
Results posted
No
Data monitoring committee
Yes
Individual data sharing
No

Publications

  • Arko FR, Lee WA, Hill BB, Olcott C 4th, Harris EJ, Dalman RL, Fogarty TJ, Zarins CK. Impact of endovascular repair on open aortic aneurysm surgical training. J Vasc Surg. 2001 Nov;34(5):885-91. doi: 10.1067/mva.2001.118816.

    PubMed 11700491
  • Karck M, Chavan A, Hagl C, Friedrich H, Galanski M, Haverich A. The frozen elephant trunk technique: a new treatment for thoracic aortic aneurysms. J Thorac Cardiovasc Surg. 2003 Jun;125(6):1550-3. doi: 10.1016/s0022-5223(03)00045-x. No abstract available.

    PubMed 12830086
  • Usui A, Ueda Y, Watanabe T, Kawaguchi O, Ohara Y, Takagi Y, Tajima K, Nishikimi N, Ishiguchi T. Clinical results of implantation of an endovascular covered stent-graft via midsternotomy for distal aortic arch aneurysm. Cardiovasc Surg. 2000 Dec;8(7):545-9. doi: 10.1016/s0967-2109(00)00066-1.

    PubMed 11068215
  • Karck M, Kamiya H. Progress of the treatment for extended aortic aneurysms; is the frozen elephant trunk technique the next standard in the treatment of complex aortic disease including the arch? Eur J Cardiothorac Surg. 2008 Jun;33(6):1007-13. doi: 10.1016/j.ejcts.2008.02.030. Epub 2008 Apr 10.

    PubMed 18406159
  • Shrestha M, Pichlmaier M, Martens A, Hagl C, Khaladj N, Haverich A. Total aortic arch replacement with a novel four-branched frozen elephant trunk graft: first-in-man results. Eur J Cardiothorac Surg. 2013 Feb;43(2):406-10. doi: 10.1093/ejcts/ezs296. Epub 2012 May 31.

    PubMed 22653445
  • Patel AY, Eagle KA, Vaishnava P. Acute type B aortic dissection: insights from the International Registry of Acute Aortic Dissection. Ann Cardiothorac Surg. 2014 Jul;3(4):368-74. doi: 10.3978/j.issn.2225-319X.2014.07.06.

    PubMed 25133099
  • Tsai TT, Trimarchi S, Nienaber CA. Acute aortic dissection: perspectives from the International Registry of Acute Aortic Dissection (IRAD). Eur J Vasc Endovasc Surg. 2009 Feb;37(2):149-59. doi: 10.1016/j.ejvs.2008.11.032. Epub 2008 Dec 20.

    PubMed 19097813
  • Jakob H, Tsagakis K. International E-vita open registry. Ann Cardiothorac Surg. 2013 May;2(3):296-9. doi: 10.3978/j.issn.2225-319X.2013.03.10.

    PubMed 23977597
  • Bortone AS, Schena S, D'Agostino D, Dialetto G, Paradiso V, Mannatrizio G, Fiore T, Cotrufo M, de Luca Tupputi Schinosa L. Immediate versus delayed endovascular treatment of post-traumatic aortic pseudoaneurysms and type B dissections: retrospective analysis and premises to the upcoming European trial. Circulation. 2002 Sep 24;106(12 Suppl 1):I234-40.

    PubMed 12354739

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.