AzTrials
AzTrials

Dentin SensitivityNCT03750851

CPP-ACPF and Laser's Effect on Dentin Hypersensitivity

A study testing CPPACPF, Laser and LaserCPPACPF in people with Dentin Sensitivity, run by Universidade Federal do Para at 1 site in Brazil.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The aim of this study was to evaluate the effect of casein phosphopeptide amorphous calcium phosphate fluoride paste (CPP-ACPF) associated with low level laser therapy (LLLT) in the symptomatology and on the quality of life of the individuals with dentin hypersensitivity in a randomized placebo-controlled clinical… Read more about this study

Who is it for?
Ages 18 to 50 yearsHealthy volunteers can take part
Conditions the study is for
Dentin Sensitivity
What is being tested?
CPPACPF, Laser and LaserCPPACPF
Could I receive a placebo?
Yes, some participants may receive a placebo
How many people
45 participants
Where
1 siteBrazil
Study dates
11 Jun 2018to 14 Dec 2018
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 50 years
  • All sexes
  • Healthy volunteers accepted
  • Adult

Who may be able to join

  • The presence of at least two hypersensitive teeth;

Who cannot join

  • Milk's proteins allergy;
  • Systemic diseases;
  • Teeth with carious lesions or pulpitis;
  • Teeth with defective restorations;
  • Teeth with with cleft enamel;
  • Patients with active periodontal disease;
Show all 9Show fewer
  • Patients with analgesic medication;
  • Patients with pregnant or lactating women
  • Patients who have received professional desensitizing treatment in the last three months.

Trial locations and contacts

1 site in 1 country.

Brazil1 site
  • Para's Federal University

    Belém, Pará, 66075-110

Other trials in Brazil

About this study

Official title: CPP-ACPF and Low Level Laser Therapy Effect on Symptomatology and Quality of Life of People With Dentin Hypersensitivity: A Clinical, Randomized, Double-blind Study

The aim of this study was to evaluate the effect of casein phosphopeptide amorphous calcium phosphate fluoride paste (CPP-ACPF) associated with low level laser therapy (LLLT) in the symptomatology and on the quality of life of the individuals with dentin hypersensitivity in a randomized placebo-controlled clinical trial. Volunteers 18 to 50 years old with hypersensitive teeth were randomized into 4 groups: GPlacebo - positioning of the laser tip without light emission + placebo dentifrice; GCPPACPF - positioning of the laser tip without light emission + CPP-ACPF application; GLaser - laser tip positioning with light emission + placebo dentifrice; GLaserCPPACPF - positioning and light emission of the laser beam + CPP-ACPF.

Read the detailed description

GLaser received the laser application using the infrared light spectrum with wavelength of 808 nm with its active AsGaAl medium in two points of the vestibular face of the hypersensitive teeth. At each point it was applied 60 J / cm², for 16 seconds. Three laser's sessions were applied with a time interval of 24 hours between them. GLaserCPPACPF first received the CPPACPF application and then the laser application according to the manufacturer's recommendations. Before initiating laser therapy, the equipment was calibrated with a tester (MMOptics Ltda®, Brazil).

The GCPPACPF volunteers were submitted to the application of the CPPACPF'S containing tooth paste MI Paste Plus™ (Recaldent™, GC América, USA) on the vestibular surfaces of hypersensitive teeth with the aid of a microbrush applicator (Microbrush, 3M ESPE, Brazil) for 05 minutes. Then, a rubber cup (Unid Microdont, Brazil) mounted on a low speed handpiece (500, Kavo, Germany) was used to scrub the desensitizing gel during 20 seconds on each tooth, according to the manufacturer's specifications. GPlacebo followed the same protocol used in GCPPACPF. In addition to the desensitizing treatments, all GCPPACPF and GPlacebo volunteers received the positioning of the laser tip to mimic the light emission produced in GLaser and GLaserCPPACPF. The noise emitted by the laser device was mimic through the sound reproduction of a smartphone application (HD Voice Recorder - iPhone 6s, Apple®, USA).

Being tested
Placebo, CPPACPF, Laser, LaserCPPACPF
Keywords
desensitizing treatment, dental hypersensitivity, CPPACPF, Low level laser therapy
Medical subject headings
Dentin Sensitivity

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • PlaceboOther

    In this group, a water soluble gel without addition any desensitizing agent (K-Y®, Johnson \& Johnson, Brazil) was applied to hypersensitive dentin. The GPlacebo volunteers were submitted to the application of placebo dentifrice on the vestibular surfaces of hypersensitive teeth with the aid of a microbrush applicator (Microbrush, 3M ESPE, Brazil) and left undisturbed on the surface during 05 minutes. Then, a rubber cup (Unid Microdont, Brazil) mounted on a low speed handpiece (500, Kavo, Germany) was used to scrub the placebo gel for 20 seconds on each tooth.

  • CPPACPFOther

    In this group, a toothpaste MI Paste Plus™ (Recaldent™, GC América, USA) was applied to hypersensitive dentin. The GCPPACPF volunteers were submitted to the application of the paste dentifrice on the vestibular surfaces of hypersensitive teeth with the aid of a microbrush applicator (Microbrush, 3M ESPE, Brazil) and left undisturbed on the surface during 05 minutes. Then, a rubber cup (Unid Microdont, Brazil) mounted on a low speed handpiece (500, Kavo, Germany) were used to scrub the desensitizing gel for 20 seconds on each tooth.

  • LaserOther

    In this group, the diode laser with an active medium of Asauxa bauxite (Photon Lase III, DMC Equipamentos Ltda, Brazil) was applied in hypersensitive dentin. GLaser received the laser application using the infrared light spectrum with wavelength of 808 nm with its active AsGaAl medium in two points of the vestibular face of the hypersensitive teeth. It was applied at each point 60 J / cm², for 16 seconds. The laser was applied in 3 sessions with a time interval of 24 hours between them.

  • LaserCPPACPFOther

    In this group the laser + CPP-ACPF was applied. The laser was used with light intensity medium Asauxa (Photon Lase III, DMC Equipamentos Ltda, Brazil) and a toothpaste containing CPP-ACPF MI Paste Plus™ (Recaldent™, GC América, USA) was applied in hypersensitive dentin. GLaserCPPacpf first named a toothpaste application and them the laser application, according to the manufacturer's recommendations.

Study groups in NCT03750851
Study groupRoleWhat they receive
GPlaceboPlacebo comparatorIn this group, a water soluble gel without addition any desensitizing agent (K-Y®, Johnson \& Johnson, Brazil) was applied to hypersensitive dentin. The GPlacebo volunteers were submitted to the application of placebo dentifrice on the vestibular surfaces of hypersensitive teeth with the aid of a microbrush applicator (Microbrush, 3M ESPE, Brazil) and left undisturbed on the surface during 05 minutes. Then, a rubber cup (Unid Microdont, Brazil) mounted on a low speed handpiece (500, Kavo, Germany) was used to scrub the placebo gel for 20 seconds on each tooth.
Receives: Other: Placebo
GCPPACPFExperimentalIn this group, a toothpaste MI Paste Plus™ (Recaldent™, GC América, USA) was applied to hypersensitive dentin. The GCPPACPF volunteers were submitted to the application of the paste dentifrice on the vestibular surfaces of hypersensitive teeth with the aid of a microbrush applicator (Microbrush, 3M ESPE, Brazil) and left undisturbed on the surface during 05 minutes. Then, a rubber cup (Unid Microdont, Brazil) mounted on a low speed handpiece (500, Kavo, Germany) were used to scrub the desensitizing gel for 20 seconds on each tooth.
Receives: Other: CPPACPF
GLaserExperimentalIn this group, the diode laser with an active medium of Asauxa bauxite (Photon Lase III, DMC Equipamentos Ltda, Brazil) was applied in hypersensitive dentin. GLaser received the laser application using the infrared light spectrum with wavelength of 808 nm with its active AsGaAl medium in two points of the vestibular face of the hypersensitive teeth. It was applied at each point 60 J / cm², for 16 seconds. The laser was applied in 3 sessions with a time interval of 24 hours between them.
Receives: Other: Laser
GLaserCPPACPFExperimentalIn this group the laser + CPP-ACPF was applied. The laser was used with light intensity medium Asauxa (Photon Lase III, DMC Equipamentos Ltda, Brazil) and a toothpaste containing CPP-ACPF MI Paste Plus™ (Recaldent™, GC América, USA) was applied in hypersensitive dentin. GLaserCPPacpf first named a toothpaste application and them the laser application, according to the manufacturer's recommendations.
Receives: Other: LaserCPPACPF

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Efficacy of treatment in dental sensitivity intensity change as assessed by VAS

    Self reported dentin sensitivity intensity before and after desensitizing treatment. Giving an score for each tooth by marking in the Visual Analogue Scale (VAS) from 0-10 (0-no pain and 10-pain as bad as it can be). With lower values representing a better outcome.

    Measured: 1 month

  2. Quality of life change

    Self reported dentin sensitivity intensity impact in the quality's of life before and after desensitizing treatment. By answering an specific questionnaire: Dentine Hypersensitivity Experience Questionnaire, measured in a likert scale from 7 to 1 (Where 7 is strongly agree and 1 is strongly disagree). With lower values representing a better outcome.

    Measured: 1 month

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted23 Nov 2018
  2. Study start11 Jun 2018
  3. Primary completion7 Dec 2018
  4. Study completion14 Dec 2018

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Double blind
Who is masked
Participant, Outcomes assessor
Enrolment
45 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03750851
Sponsor's protocol ID
UFPara-005
Status last verified
Apr 2019
First submitted
19 Nov 2018
Last updated
17 Apr 2019
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided

Questions about this trial

What is this clinical trial studying?

A study testing CPPACPF, Laser and LaserCPPACPF in people with Dentin Sensitivity, run by Universidade Federal do Para at 1 site in Brazil.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 17 Apr 2019. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Brazil. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. Some participants in this study may receive a placebo. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Efficacy of treatment in dental sensitivity intensity change as assessed by VAS (time frame: 1 month). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Apr 2019.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in