Dentin SensitivityNCT03750851
CPP-ACPF and Laser's Effect on Dentin Hypersensitivity
A study testing CPPACPF, Laser and LaserCPPACPF in people with Dentin Sensitivity, run by Universidade Federal do Para at 1 site in Brazil.
Trial summary
The aim of this study was to evaluate the effect of casein phosphopeptide amorphous calcium phosphate fluoride paste (CPP-ACPF) associated with low level laser therapy (LLLT) in the symptomatology and on the quality of life of the individuals with dentin hypersensitivity in a randomized placebo-controlled clinical… Read more about this study
- Who is it for?
- Ages 18 to 50 yearsHealthy volunteers can take part
- Conditions the study is for
- Dentin Sensitivity
- What is being tested?
- CPPACPF, Laser and LaserCPPACPF
- Could I receive a placebo?
- Yes, some participants may receive a placebo
- How many people
- 45 participants
- Where
- 1 siteBrazil
- Study dates
- 11 Jun 2018to 14 Dec 2018
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 50 years
- All sexes
- Healthy volunteers accepted
- Adult
Who may be able to join
- The presence of at least two hypersensitive teeth;
Who cannot join
- Milk's proteins allergy;
- Systemic diseases;
- Teeth with carious lesions or pulpitis;
- Teeth with defective restorations;
- Teeth with with cleft enamel;
- Patients with active periodontal disease;
Show all 9Show fewer
- Patients with analgesic medication;
- Patients with pregnant or lactating women
- Patients who have received professional desensitizing treatment in the last three months.
Trial locations and contacts
1 site in 1 country.
About this study
Official title: CPP-ACPF and Low Level Laser Therapy Effect on Symptomatology and Quality of Life of People With Dentin Hypersensitivity: A Clinical, Randomized, Double-blind Study
The aim of this study was to evaluate the effect of casein phosphopeptide amorphous calcium phosphate fluoride paste (CPP-ACPF) associated with low level laser therapy (LLLT) in the symptomatology and on the quality of life of the individuals with dentin hypersensitivity in a randomized placebo-controlled clinical trial. Volunteers 18 to 50 years old with hypersensitive teeth were randomized into 4 groups: GPlacebo - positioning of the laser tip without light emission + placebo dentifrice; GCPPACPF - positioning of the laser tip without light emission + CPP-ACPF application; GLaser - laser tip positioning with light emission + placebo dentifrice; GLaserCPPACPF - positioning and light emission of the laser beam + CPP-ACPF.
Read the detailed description
GLaser received the laser application using the infrared light spectrum with wavelength of 808 nm with its active AsGaAl medium in two points of the vestibular face of the hypersensitive teeth. At each point it was applied 60 J / cm², for 16 seconds. Three laser's sessions were applied with a time interval of 24 hours between them. GLaserCPPACPF first received the CPPACPF application and then the laser application according to the manufacturer's recommendations. Before initiating laser therapy, the equipment was calibrated with a tester (MMOptics Ltda®, Brazil).
The GCPPACPF volunteers were submitted to the application of the CPPACPF'S containing tooth paste MI Paste Plus™ (Recaldent™, GC América, USA) on the vestibular surfaces of hypersensitive teeth with the aid of a microbrush applicator (Microbrush, 3M ESPE, Brazil) for 05 minutes. Then, a rubber cup (Unid Microdont, Brazil) mounted on a low speed handpiece (500, Kavo, Germany) was used to scrub the desensitizing gel during 20 seconds on each tooth, according to the manufacturer's specifications. GPlacebo followed the same protocol used in GCPPACPF. In addition to the desensitizing treatments, all GCPPACPF and GPlacebo volunteers received the positioning of the laser tip to mimic the light emission produced in GLaser and GLaserCPPACPF. The noise emitted by the laser device was mimic through the sound reproduction of a smartphone application (HD Voice Recorder - iPhone 6s, Apple®, USA).
- Conditions
- Dentin Sensitivity
- Being tested
- Placebo, CPPACPF, Laser, LaserCPPACPF
- Keywords
- desensitizing treatment, dental hypersensitivity, CPPACPF, Low level laser therapy
- Medical subject headings
- Dentin Sensitivity
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
PlaceboOther
In this group, a water soluble gel without addition any desensitizing agent (K-Y®, Johnson \& Johnson, Brazil) was applied to hypersensitive dentin. The GPlacebo volunteers were submitted to the application of placebo dentifrice on the vestibular surfaces of hypersensitive teeth with the aid of a microbrush applicator (Microbrush, 3M ESPE, Brazil) and left undisturbed on the surface during 05 minutes. Then, a rubber cup (Unid Microdont, Brazil) mounted on a low speed handpiece (500, Kavo, Germany) was used to scrub the placebo gel for 20 seconds on each tooth.
CPPACPFOther
In this group, a toothpaste MI Paste Plus™ (Recaldent™, GC América, USA) was applied to hypersensitive dentin. The GCPPACPF volunteers were submitted to the application of the paste dentifrice on the vestibular surfaces of hypersensitive teeth with the aid of a microbrush applicator (Microbrush, 3M ESPE, Brazil) and left undisturbed on the surface during 05 minutes. Then, a rubber cup (Unid Microdont, Brazil) mounted on a low speed handpiece (500, Kavo, Germany) were used to scrub the desensitizing gel for 20 seconds on each tooth.
LaserOther
In this group, the diode laser with an active medium of Asauxa bauxite (Photon Lase III, DMC Equipamentos Ltda, Brazil) was applied in hypersensitive dentin. GLaser received the laser application using the infrared light spectrum with wavelength of 808 nm with its active AsGaAl medium in two points of the vestibular face of the hypersensitive teeth. It was applied at each point 60 J / cm², for 16 seconds. The laser was applied in 3 sessions with a time interval of 24 hours between them.
LaserCPPACPFOther
In this group the laser + CPP-ACPF was applied. The laser was used with light intensity medium Asauxa (Photon Lase III, DMC Equipamentos Ltda, Brazil) and a toothpaste containing CPP-ACPF MI Paste Plus™ (Recaldent™, GC América, USA) was applied in hypersensitive dentin. GLaserCPPacpf first named a toothpaste application and them the laser application, according to the manufacturer's recommendations.
| Study group | Role | What they receive |
|---|---|---|
| GPlacebo | Placebo comparator | In this group, a water soluble gel without addition any desensitizing agent (K-Y®, Johnson \& Johnson, Brazil) was applied to hypersensitive dentin. The GPlacebo volunteers were submitted to the application of placebo dentifrice on the vestibular surfaces of hypersensitive teeth with the aid of a microbrush applicator (Microbrush, 3M ESPE, Brazil) and left undisturbed on the surface during 05 minutes. Then, a rubber cup (Unid Microdont, Brazil) mounted on a low speed handpiece (500, Kavo, Germany) was used to scrub the placebo gel for 20 seconds on each tooth. Receives: Other: Placebo |
| GCPPACPF | Experimental | In this group, a toothpaste MI Paste Plus™ (Recaldent™, GC América, USA) was applied to hypersensitive dentin. The GCPPACPF volunteers were submitted to the application of the paste dentifrice on the vestibular surfaces of hypersensitive teeth with the aid of a microbrush applicator (Microbrush, 3M ESPE, Brazil) and left undisturbed on the surface during 05 minutes. Then, a rubber cup (Unid Microdont, Brazil) mounted on a low speed handpiece (500, Kavo, Germany) were used to scrub the desensitizing gel for 20 seconds on each tooth. Receives: Other: CPPACPF |
| GLaser | Experimental | In this group, the diode laser with an active medium of Asauxa bauxite (Photon Lase III, DMC Equipamentos Ltda, Brazil) was applied in hypersensitive dentin. GLaser received the laser application using the infrared light spectrum with wavelength of 808 nm with its active AsGaAl medium in two points of the vestibular face of the hypersensitive teeth. It was applied at each point 60 J / cm², for 16 seconds. The laser was applied in 3 sessions with a time interval of 24 hours between them. Receives: Other: Laser |
| GLaserCPPACPF | Experimental | In this group the laser + CPP-ACPF was applied. The laser was used with light intensity medium Asauxa (Photon Lase III, DMC Equipamentos Ltda, Brazil) and a toothpaste containing CPP-ACPF MI Paste Plus™ (Recaldent™, GC América, USA) was applied in hypersensitive dentin. GLaserCPPacpf first named a toothpaste application and them the laser application, according to the manufacturer's recommendations. Receives: Other: LaserCPPACPF |
What is being measured
The primary outcome is the main question the study is designed to answer.
Efficacy of treatment in dental sensitivity intensity change as assessed by VAS
Self reported dentin sensitivity intensity before and after desensitizing treatment. Giving an score for each tooth by marking in the Visual Analogue Scale (VAS) from 0-10 (0-no pain and 10-pain as bad as it can be). With lower values representing a better outcome.
Measured: 1 month
Quality of life change
Self reported dentin sensitivity intensity impact in the quality's of life before and after desensitizing treatment. By answering an specific questionnaire: Dentine Hypersensitivity Experience Questionnaire, measured in a likert scale from 7 to 1 (Where 7 is strongly agree and 1 is strongly disagree). With lower values representing a better outcome.
Measured: 1 month
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted23 Nov 2018
- Study start11 Jun 2018
- Primary completion7 Dec 2018
- Study completion14 Dec 2018
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Dentin SensitivityStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Double blind
- Who is masked
- Participant, Outcomes assessor
- Enrolment
- 45 participants (actual)
Sponsor and investigators
- Lead sponsor
- Universidade Federal do Para
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Cecy Martins Silva, Universidade Federal do Para
- Investigators
- Cecy M Silva, PhD, Principal investigator, clinical professor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03750851
- Sponsor's protocol ID
- UFPara-005
- Status last verified
- Apr 2019
- First submitted
- 19 Nov 2018
- Last updated
- 17 Apr 2019
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Undecided
Study at a glance
From the registry record, last updated by the sponsor on 17 Apr 2019. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- CPP-ACPF and Low Level Laser Therapy Effect on Symptomatology and Quality of Life of People With Dentin Hypersensitivity: A Clinical, Randomized, Double-blind Study
- ClinicalTrials.gov ID
- NCT03750851
- Acronym / sponsor ID
- UFPara-005
- Conditions
- Dentin Sensitivity
- Keywords
- desensitizing treatment, dental hypersensitivity, CPPACPF, Low level laser therapy
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 45 participants (actual)
- Lead sponsor
- Universidade Federal do ParaUniversity, hospital or other
- Study start
- 11 Jun 2018 (actual)
- Primary completion
- 7 Dec 2018 (actual)
- Study completion
- 14 Dec 2018 (actual)
- First posted
- 23 Nov 2018 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The aim of this study was to evaluate the effect of casein phosphopeptide amorphous calcium phosphate fluoride paste (CPP-ACPF) associated with low level laser therapy (LLLT) in the symptomatology and on the quality of life of the individuals with dentin hypersensitivity in a randomized placebo-controlled clinical trial. Volunteers 18 to 50 years old with hypersensitive teeth were randomized into 4 groups: GPlacebo - positioning of the laser tip without light emission + placebo dentifrice; GCPPACPF - positioning of the laser tip without light emission + CPP-ACPF application; GLaser - laser tip positioning with light emission + placebo dentifrice; GLaserCPPACPF - positioning and light emission of the laser beam + CPP-ACPF.
Detailed description
GLaser received the laser application using the infrared light spectrum with wavelength of 808 nm with its active AsGaAl medium in two points of the vestibular face of the hypersensitive teeth. At each point it was applied 60 J / cm², for 16 seconds. Three laser's sessions were applied with a time interval of 24 hours between them. GLaserCPPACPF first received the CPPACPF application and then the laser application according to the manufacturer's recommendations. Before initiating laser therapy, the equipment was calibrated with a tester (MMOptics Ltda®, Brazil).
The GCPPACPF volunteers were submitted to the application of the CPPACPF'S containing tooth paste MI Paste Plus™ (Recaldent™, GC América, USA) on the vestibular surfaces of hypersensitive teeth with the aid of a microbrush applicator (Microbrush, 3M ESPE, Brazil) for 05 minutes. Then, a rubber cup (Unid Microdont, Brazil) mounted on a low speed handpiece (500, Kavo, Germany) was used to scrub the desensitizing gel during 20 seconds on each tooth, according to the manufacturer's specifications. GPlacebo followed the same protocol used in GCPPACPF. In addition to the desensitizing treatments, all GCPPACPF and GPlacebo volunteers received the positioning of the laser tip to mimic the light emission produced in GLaser and GLaserCPPACPF. The noise emitted by the laser device was mimic through the sound reproduction of a smartphone application (HD Voice Recorder - iPhone 6s, Apple®, USA).
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Double blind (participant, outcomes assessor)
- Number of arms
- 4
| Arm | Type | Receives |
|---|---|---|
| GPlacebo | Placebo comparator | Other: PlaceboIn this group, a water soluble gel without addition any desensitizing agent (K-Y®, Johnson \& Johnson, Brazil) was applied to hypersensitive dentin. The GPlacebo volunteers were submitted to the application of placebo dentifrice on the vestibular surfaces of hypersensitive teeth with the aid of a microbrush applicator (Microbrush, 3M ESPE, Brazil) and left undisturbed on the surface during 05 minutes. Then, a rubber cup (Unid Microdont, Brazil) mounted on a low speed handpiece (500, Kavo, Germany) was used to scrub the placebo gel for 20 seconds on each tooth. |
| GCPPACPF | Experimental | Other: CPPACPFIn this group, a toothpaste MI Paste Plus™ (Recaldent™, GC América, USA) was applied to hypersensitive dentin. The GCPPACPF volunteers were submitted to the application of the paste dentifrice on the vestibular surfaces of hypersensitive teeth with the aid of a microbrush applicator (Microbrush, 3M ESPE, Brazil) and left undisturbed on the surface during 05 minutes. Then, a rubber cup (Unid Microdont, Brazil) mounted on a low speed handpiece (500, Kavo, Germany) were used to scrub the desensitizing gel for 20 seconds on each tooth. |
| GLaser | Experimental | Other: LaserIn this group, the diode laser with an active medium of Asauxa bauxite (Photon Lase III, DMC Equipamentos Ltda, Brazil) was applied in hypersensitive dentin. GLaser received the laser application using the infrared light spectrum with wavelength of 808 nm with its active AsGaAl medium in two points of the vestibular face of the hypersensitive teeth. It was applied at each point 60 J / cm², for 16 seconds. The laser was applied in 3 sessions with a time interval of 24 hours between them. |
| GLaserCPPACPF | Experimental | Other: LaserCPPACPFIn this group the laser + CPP-ACPF was applied. The laser was used with light intensity medium Asauxa (Photon Lase III, DMC Equipamentos Ltda, Brazil) and a toothpaste containing CPP-ACPF MI Paste Plus™ (Recaldent™, GC América, USA) was applied in hypersensitive dentin. GLaserCPPacpf first named a toothpaste application and them the laser application, according to the manufacturer's recommendations. |
Who may qualify
- Ages
- 18 to 50 years
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult
Key inclusion criteria (1 listed)
- The presence of at least two hypersensitive teeth;
Key exclusion criteria (9 listed)
- Milk's proteins allergy;
- Systemic diseases;
- Teeth with carious lesions or pulpitis;
- Teeth with defective restorations;
- Teeth with with cleft enamel;
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| PlaceboIn this group, a water soluble gel without addition any desensitizing agent (K-Y®, Johnson \& Johnson, Brazil) was applied to hypersensitive dentin. The GPlacebo volunteers were submitted to the application of placebo dentifrice on the vestibular surfaces of hypersensitive teeth with the aid of a microbrush applicator (Microbrush, 3M ESPE, Brazil) and left undisturbed on the surface during 05 minutes. Then, a rubber cup (Unid Microdont, Brazil) mounted on a low speed handpiece (500, Kavo, Germany) was used to scrub the placebo gel for 20 seconds on each tooth. | Other | GPlacebo |
| CPPACPFIn this group, a toothpaste MI Paste Plus™ (Recaldent™, GC América, USA) was applied to hypersensitive dentin. The GCPPACPF volunteers were submitted to the application of the paste dentifrice on the vestibular surfaces of hypersensitive teeth with the aid of a microbrush applicator (Microbrush, 3M ESPE, Brazil) and left undisturbed on the surface during 05 minutes. Then, a rubber cup (Unid Microdont, Brazil) mounted on a low speed handpiece (500, Kavo, Germany) were used to scrub the desensitizing gel for 20 seconds on each tooth. | Other | GCPPACPF |
| LaserIn this group, the diode laser with an active medium of Asauxa bauxite (Photon Lase III, DMC Equipamentos Ltda, Brazil) was applied in hypersensitive dentin. GLaser received the laser application using the infrared light spectrum with wavelength of 808 nm with its active AsGaAl medium in two points of the vestibular face of the hypersensitive teeth. It was applied at each point 60 J / cm², for 16 seconds. The laser was applied in 3 sessions with a time interval of 24 hours between them. | Other | GLaser |
| LaserCPPACPFIn this group the laser + CPP-ACPF was applied. The laser was used with light intensity medium Asauxa (Photon Lase III, DMC Equipamentos Ltda, Brazil) and a toothpaste containing CPP-ACPF MI Paste Plus™ (Recaldent™, GC América, USA) was applied in hypersensitive dentin. GLaserCPPacpf first named a toothpaste application and them the laser application, according to the manufacturer's recommendations. | Other | GLaserCPPACPF |
Primary outcome
Efficacy of treatment in dental sensitivity intensity change as assessed by VAS
Time frame: 1 month
Self reported dentin sensitivity intensity before and after desensitizing treatment. Giving an score for each tooth by marking in the Visual Analogue Scale (VAS) from 0-10 (0-no pain and 10-pain as bad as it can be). With lower values representing a better outcome.
Quality of life change
Time frame: 1 month
Self reported dentin sensitivity intensity impact in the quality's of life before and after desensitizing treatment. By answering an specific questionnaire: Dentine Hypersensitivity Experience Questionnaire, measured in a likert scale from 7 to 1 (Where 7 is strongly agree and 1 is strongly disagree). With lower values representing a better outcome.
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 17 Apr 2019.
- Individual participant dataSharing planned: Undecided
Related trials for Dentin Sensitivity
Not yet recruiting
A Study to Assess the Efficacy of a Calcium Sodium Phosphosilicate Toothpaste for the Relief of Dentine Hypersensitivity
Dentin Sensitivity
Active, not recruiting
Clinical Evaluation of Short Dentin Etching
Hypersensitivity Dentin, Dental Restoration Failure of Marginal Integrity
Recruiting
Peroxide Versus Non-Peroxide In-Office Tooth Bleaching
Tooth Discoloration, Tooth Staining
Recruiting
Dentine Hypersensitivity Using Dentine Adhesive With Strontium-doped Bioactive Glass-Ceramic
Dentine Hypersensitivity
Not yet recruiting
A Clinical Study to Assess the Efficacy of a Calcium Sodium Phosphosilicate Toothpaste for the Relief of Dentine Hypersensitivity
Dentin Sensitivity
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Cecy M Silva, PhD principal investigator
clinical professor
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing CPPACPF, Laser and LaserCPPACPF in people with Dentin Sensitivity, run by Universidade Federal do Para at 1 site in Brazil.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 17 Apr 2019. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Brazil. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. Some participants in this study may receive a placebo. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Efficacy of treatment in dental sensitivity intensity change as assessed by VAS (time frame: 1 month). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Apr 2019.