Phase I study evaluating the feasibility of using electromagnetic navigation (EMN) for the catheter implantation procedure required of cervical brachytherapy. The addition of EMN to the current HDR brachytherapy workflow has the potential to dramatically improve implant quality and efficiency for the gynecological… Read more about this study

Who is it for?
Any age, women only
Conditions the study is for
Cervical Cancer
What is being tested?
Electromagnetic Navigation
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
10 participants
Where
1 siteCanada
Study dates
1 Oct 2019to Feb 2021
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • Women only
  • No healthy volunteers
  • Child, Adult, Older adult

Who may be able to join

  • Women diagnosed with FIGO stage IB2-IVA (locally advanced) cervical cancer being treated with combined 3D interstitial / intracavitary HDR brachytherapy in 4 fractions and concurrent chemotherapy
  • Minimum of 2 brachytherapy implantation procedures.
  • The Syed-Neblett applicator is indicated for use due to the extent/complexity of the disease
  • Given informed consent to take part in the study

Who cannot join

  • Metastatic disease
  • Bilateral or unilateral hip prostheses
  • Pacemakers

Trial locations and contacts

1 site in 1 country.

Canada1 site, 1 recruiting
  • Sunnybrook Health Sciences Centre

    Toronto, Ontario, M4N 3M5

    Ananth Ravi, PhD

    Recruiting

Other trials in Canada

About this study

Official title: ElectroMagnetic-guided Interstitial Catheter Navigation for Gynecological brachyTherapy: A Phase I Trial

Phase I study evaluating the feasibility of using electromagnetic navigation (EMN) for the catheter implantation procedure required of cervical brachytherapy. The addition of EMN to the current HDR brachytherapy workflow has the potential to dramatically improve implant quality and efficiency for the gynecological interstitial brachytherapy program. Implant quality has been reported to be an important predictive factor for local control and late toxicity.

Read the detailed description

Cervical cancer poses a significant local and global health problem. In 2017 over 1,500 Canadian women were predicted to develop cervical cancer, and another 400 were approximated to die from the disease. Cervical cancer rates have steadily decreased in developed nations largely due to regular gynaecological screening and public human papillomavirus vaccination programs; however, the disease accounts for up to 12% of all female cancer diagnoses in developing nations, and poses a disproportionate burden on aboriginal women across Canada. Much work needs to be done to address disparities in care and treatment for cervical cancer, both in Canada and worldwide.

FIGO stage IA - IB1 is considered localized disease and treated primarily with surgery. In contrast to early stage disease, tumours that extend greater than 4 cm and beyond the cervix are considered locally advanced. The standard of care for locally advanced cervical cancer defined as FIGO stages IB2 - IVA is external beam radiation therapy with concurrent chemotherapy followed by brachytherapy.

Brachytherapy is a crucial component of therapeutic management that has been shown to be associated with improved local control. High dose rate brachytherapy involves the treatment of local bulky disease using a remotely loaded Iridium-192 source. Brachytherapy delivery exploits rapid dose fall off, allowing for the central pelvis to receive a very high dose while sparing the bladder, rectum, sigmoid and small bowel. This dose escalation is beyond what is conventionally achievable using external radiation therapy methods. More specifically, image guided adaptive brachytherapy employing intracavitary applicators allows for dose optimization and improves target dose coverage for limited size tumours.

Intracavitary applicators have been shown to be adequate from covering symmetric small tumours less than 30 cc. However, for large or complex asymmetric tumours with/without vaginal involvement they are not sufficient to cover the target while respecting normal tissue tolerances. To compensate for these limitations, improvements in local control have been achieved using a combined interstitial and intracavitary technique for larger tumours. Combined intracavitary - interstitial applicators have been designed to target tumours that are not adequately covered by intracavitary applicators alone. The addition of the interstitial technique involves the insertion of catheters into the tumour enabling higher dose conformity and normal tissue sparing. This combined technique has been shown in large tumours with extensive parametrial involvement as well as in cases with unfavourable topography to be effective. Employing this combined technique, perineal-based interstitial image guided adaptive brachytherapy makes it possible to deliver higher doses to the high risk clinical target volume without increasing dose to the bladder, rectum or sigmoid.

The combined interstitial and intracavitary brachytherapy workflow for locally advanced cervical cancer at the Odette Cancer Centre typically consists of four treatment fractions. The workflow begins with a pre-brachytherapy assessment MRI that is taken before brachytherapy treatment to assist in preplanning of catheter depth and location. At the time of this MRI the patient will have a vaginal cylinder in place. 1-2 weeks after the MRI, the implant and treatment is performed. Prior to the implantation procedure, the patient is given light sedation and a spinal anesthetic, subsequently a vaginal cylinder (Best Medical Systems, Inc, Springfield VA) is inserted into the patient. A perineal template that contains a central opening is fit on the vaginal cylinder. The template is then advanced until it is appositional on the perineum of the patient. Plastic catheters (6F 24 cm) containing metal stylets are inserted through the template and along the grooves of the vaginal cylinder thereby penetrating the perineum and the vagina, respectively. The number, position and depth of the catheters that are used are based on the pre-brachytherapy assessment MRI. After the implantation procedure the template is sutured to the patient and the patient is transferred to an MRI suite where an image of her anatomy is acquired with the catheters and applicators in place. The patient is then sent for a CT scan that is to be used for treatment planning.

Treatment planning involves the registration of the CT and MR datasets. The MR images are used to identify the soft tissue organs at risk and the targets. The CT is used to identify the catheters implanted in the patient. Using the knowledge of where the applicator/catheters are with respect to the targets and organs at risk, a dose distribution is designed to target the cancer while sparing normal tissue. On the same day as the implantation, one treatment fraction is delivered and the patient is admitted overnight. The next day the patient may as a standard of care, depending on the clinical indication undergo one or two additional fractions, separated by at least 6 hours. A week later the same process for the first two fractions will be repeated for the remaining two fractions.

During the insertion of catheters, it has been recognized that they can converge or diverge as they pierce stiff tissues along the implantation path. Without proper image guidance, a template guided interstitial implant could result in an increase in risk of normal tissue complications. Real-time image guidance for catheter insertion is institution dependent, at the Odette Cancer Centre trans-abdominal ultrasound is used for placement of the tandem and more recently the trans-rectal ultrasound has been investigated for catheter placement. Other forms of real-time catheter guidance used at different centres include fluoroscopy, computed tomography (CT), and magnetic resonance imaging (MRI).

The quality of interstitial brachytherapy implants has been reported to be an important predictive factor for local control and late toxicity. The quality of the implant is dependent on the geometry of the catheters, and real time image guidance for interstitial cervical brachytherapy is markedly lacking.

At the Odette Cancer Centre, a four-patient study was conducted to characterize the amount of catheter deflection and angulation during gynaecological high-dose-rate interstitial brachytherapy. Results from this study demonstrated that the mean value of the maximum catheter deflection at the level of the GTV was 9.1 mm +/- 3.2 mm (range 3.0 - 18.4 mm) and can approach as much as 2 cm at the level of the GTV. Although the catheter deflection observed in this study did not result in any significant dosimetric impact the sample size was small and the authors of the study suggested that further investigation into real-time catheter guidance may be necessary into alleviating this deviation to prevent suboptimal plan quality.

Electromagnetic tracking can minimize the uncertainties related to implant quality. The operation of an electromagnetic tracking device depends on a field generator producing a magnetic field that extends across the anatomy of interest. The tracked sensor in this system induces a distance-dependent voltage that is used to determine the spatial position of the sensor within the volume of interest. This technology is extensively used in clinical practice, examples include, surgical interventions, guidance of biopsies, and motion monitoring.

Electromagnetic navigation can be incorporated into the cervical interstitial brachytherapy workflow as a form of real-time catheter guidance. By incorporating this guidance into the current workflow it is possible that a higher degree of accuracy in catheter placement will be achieved when used in conjunction with image-guided brachytherapy. This study seeks to evaluate the efficacy of electromagnetic navigation on the perineal-based interstitial cervix image-guided brachytherapy workflow as part of a phase I clinical trial.

Conditions
Cervical Cancer
Being tested
Electromagnetic Navigation
Keywords
Interstitial Brachytherapy, Electromagnetic tracking, Implant quality, Image guidance
Medical subject headings
Uterine Cervical Neoplasms

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Electromagnetic NavigationDevice

    Electromagnetic navigation is a form of surgical navigation that can be incorporated into the cervical interstitial brachytherapy workflow to improve the current standards of guidance.

Study groups in NCT03781271
Study groupRoleWhat they receive
Fraction 1-Addition of EMNExperimentalDuring the fraction 1 insertion, the custom MRI-compatible vaginal cylinder will be placed in the patient, and will contain the 6 degree-of-freedom (DOF) sensor. The electromagnetic navigation system and computer will have been setup in the operating room (OR) prior to the procedure and will be used to actively insert up to 25 catheters into the target. The catheters will be inserted using a custom metallic stylet that has a custom 5-DOF sensor embedded in the tip for tracking its position in real-time. The physician may use ultrasound for assistance in target visualization as well. Catheter deflections will be detected and corrected for in real-time by the radiation oncologist as the catheter is inserted into the patient during the procedure, this will occur when the EM system is in use.
Receives: Device: Electromagnetic Navigation
Fraction 3-Addition of EMNExperimentalFor the second group of patients in the trial the same protocol will be followed as in the first group, the only difference will be that the electromagnetic navigation is used during the second implantation procedure immediately preceding fraction 3 as opposed to fraction 1, the time at which it was used for the first group of patients.
Receives: Device: Electromagnetic Navigation

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Treatment Plan Target Volume and Organs at Risk Dosimetry

    The treatment plans generated during the course of treatment for participants will be evaluated. The evaluation of the treatment plans will use the dose received by specific target structures and the dose received by structures that are defined as organs at risk. The specific metric that will be used represents how much dose is received by a certain percentage of a volume. For example, the D98 GTV refers to how much dose is received by 98 percent of the gross tumour volume. The dose is a value that is measured in the unit, Gray. In addition to the dose constraint for the D98 GTV the other dose constraints that will be used for evaluation purposes are, D90 HR-CTV, D98 HR-CTV, D98 IR-CTV and OAR constraints. A significance level of 5% will be used to identify differences between the dose constraints for treatment plans that are generated when EMN is used and when EMN is not used.

    Measured: 14 days

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted19 Dec 2018
  2. Study start1 Oct 2019
  3. Primary completionOct 2020 (estimated)
  4. Study completionFeb 2021 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Device feasibility
Allocation
Non-randomised
Intervention model
Crossover
Model description
2 arms of patients will undergo standard routine brachytherapy treatment. A part of the treatment involves the placement of catheters. For both arms of the study the placement of these catheters will be assisted by an electromagnetic navigation system. The difference between the arms will be that the navigation system will be used at different times in the course of their brachytherapy treatment to eliminate bias. One group will undergo electromagnetic navigation assisted catheter placement during their first fraction of treatment while the second arm will undergo electromagnetic navigation assisted catheter placement during their third fraction of treatment.
Masking
None (open label)
Enrolment
10 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03781271
Sponsor's protocol ID
143-2018
Acronym
E-MINT
Status last verified
Mar 2020
First submitted
26 Nov 2018
Last updated
17 Mar 2020
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Yes: Results will be made available to relevant stakeholders within the Odette Cancer Centre as these results may assist in the translation of this trial into routine clinical practice.

Questions about this trial

What is this clinical trial studying?

A study testing Electromagnetic Navigation in people with Cervical Cancer, run by Sunnybrook Health Sciences Centre at 1 site in Canada.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 17 Mar 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Ananth Ravi, PhD (416 480 6100 ext. 1092, ananth.ravi@sunnybrook.ca), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Treatment Plan Target Volume and Organs at Risk Dosimetry (time frame: 14 days). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Mar 2020.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in