AzTrials
AzTrials

Aortic Valve StenosisMASH-TAVINCT03811119

Manta™ Versus Suture-based Closure After Transcatheter Aortic Valve Implantation Trial

A study testing MANTA vascular closure device and Suture based vascular closure device in people with Aortic Valve Stenosis, run by Erasmus Medical Center at 1 site in Netherlands.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

To investigate whether the collagen-based MANTA vascular closure device (VCD) is superior to suture-based VCDs in preventing vascular access site complications in patients undergoing transfemoral transcatheter aortic valve replacement. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Aortic Valve Stenosis
What is being tested?
MANTA vascular closure device and Suture based vascular closure device
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
151 participants
Where
1 siteNetherlands
Study dates
30 Oct 2018to 30 Apr 2020
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients undergoing elective transfemoral TAVI for severe aortic valve stenosis with any commercially-available transcatheter heart valve (THV)
  • Common femoral artery diameter > 5.0mm (14 - 22F compatible)

Who cannot join

  • Symptomatic leg ischaemia
  • Previous thromboendarterectomy or plastic patch of the common femoral artery
  • Previous implantation of a suture-based VCD less than 30 days before, or a plug-based VCD within 6 months
  • Unilateral or bilateral lower extremity amputation
  • Systemic infection or a local infection at or near the access site
  • Allergy to the components any of both devices (i.e. bovine materials or any other device material, including collagen and/or collagen products, polyglycolic or polylactic acid, stainless steel or nickel)
Show all 15Show fewer
  • Active bleeding or bleeding diathesis including thrombocytopenia (platelet count <50,000 cells/UL), thrombasthenia, hemophilia, or von Willebrand disease
  • Patients in whom continuous oral anticoagulation therapy cannot be stopped for the peri-procedural period or patients with INR >1.8 at the time of the procedure
  • Patient unable to be adequately anti-coagulated for the procedure
  • Morbidly obese or cachectic (BMI >40 kg/m2 or <20 kg/m2)
  • Anatomical and procedural contraindication for suture-based or Manta closure (lack of proper puncture site in the common femoral artery in terms of calcification, size, and atherosclerotic disease)
  • Absence of computed tomographic data of the access site before the procedure
  • Patient cannot adhere to or complete the investigational protocol for any reason including but not limited to geographical residence, psychiatric condition or life threatening disease
  • Known pregnancy at time of randomization (in women of childbearing potential a negative pregnancy test is mandatory)
  • Participating in trials in which the primary endpoint includes bleeding or vascular complications

Trial locations and contacts

1 site in 1 country.

Netherlands1 site
  • Erasmus University Medical Center Rotterdam

    Rotterdam, 3000 CA

Other trials in Netherlands

About this study

Official title: MANTA™ Versus Suture-based Closure After Transcatheter Aortic Valve Implantation Trial

To investigate whether the collagen-based MANTA vascular closure device (VCD) is superior to suture-based VCDs in preventing vascular access site complications in patients undergoing transfemoral transcatheter aortic valve replacement.

Read the detailed description

see summary

Being tested
MANTA vascular closure device, Suture based vascular closure device
Keywords
Vascular Closure Devices, Transcatheter Aortic Valve Implantation
Medical subject headings
Aortic Valve Stenosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • MANTA vascular closure deviceDevice

    Collagen based vascular closure device

  • Suture based vascular closure deviceDevice

    Suture based vascular closure device (ProGlide)

Study groups in NCT03811119
Study groupRoleWhat they receive
MANTA vascular closure deviceActive comparatorArteriotomy closure with a collagen-based vascular closure device (MANTA™)
Receives: Device: MANTA vascular closure device
Suture based vascular closure deviceActive comparatorArteriotomy closure with 2 or more suture-based vascular closure devices (ProGlide)
Receives: Device: Suture based vascular closure device

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Composite rate of major- and minor vascular complications according to VARC-2

    The primary endpoint will consist of the composite of major- and minor vascular complications according to the Valve Academic Research Consortium (VARC)-2 at 30 days follow-up.

    Measured: Between transcatheter aortic valve implantation and 30 days follow-up

Secondary outcomes (10)
  1. Number of Participants with a Major Vascular Complication according to VARC-2

    total number of participants major vascular complications

    Measured: Between transcatheter aortic valve implantation and 30 days follow-up

  2. Number of Participants with a Minor Vascular Complication according to VARC-2

    total number of participants minor vascular complications

    Measured: Between transcatheter aortic valve implantation and 30 days follow-up

  3. All-cause death rate

    A distinction between cardiac-, non-cardiac vascular and non-cardiovascular death will be made

    Measured: Between transcatheter aortic valve implantation and 30 days follow-up

  4. Number of Participants with a major- or life threatening bleeding according to VARC-2

    total number of participants with major/life-threatening bleedings

    Measured: Between transcatheter aortic valve implantation and 30 days follow-up

  5. Need for transfusions for access site related bleeding/complications

    Total number of transfusions of RBC because of site-related bleeding

    Measured: Between transcatheter aortic valve implantation and 30 days follow-up

  6. Number of Participants with vascular closure device failure

    Failure of a closure device to achieve haemostasis at the arteriotomy site leading to alternative treatment (other than manual compression or adjunctive endovascular ballooning)

    Measured: Between transcatheter aortic valve implantation and 30 days follow-up

  7. Time to hemostasis

    After the use of a vascular closure device the time to hemostasis will be classified as immediate hemostasis, hemostasis after 5 minutes manual compression, hemostasis after 10 minutes manual compression, hemostasis after endovascular ballooning, hemostasis after endovascular intervention or hemostasis after surgical intervention

    Measured: During the TAVI procedure

  8. Total procedure time

    The total procedural time in minutes will be compared between the two treatment arms

    Measured: During the TAVI procedure

  9. Number of Participants with a clinically relevant bleeding defined as BARC 2, 3 and 5

    Clinically relevant bleeding defined as BARC 2, 3 and 5

    Measured: Between transcatheter aortic valve implantation and 30 days follow-up

  10. Length of hospital stay

    The total length of hospital stay in days will be compared between the two treatment arms

    Measured: Up to a maximum of 30 days after the TAVI procedure

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted22 Jan 2019
  2. Study start30 Oct 2018
  3. Primary completion1 Feb 2020
  4. Study completion30 Apr 2020

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Model description
Open label randomized trial
Masking
None (open label)
Enrolment
151 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03811119
Sponsor's protocol ID
MASH TAVI 06-09-2018
Acronym
MASH-TAVI
Status last verified
Mar 2021
First submitted
17 Jan 2019
Last updated
29 Mar 2021
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: no sharing of individual data (no permission from participants. GDPR)

Questions about this trial

What is this clinical trial studying?

A study testing MANTA vascular closure device and Suture based vascular closure device in people with Aortic Valve Stenosis, run by Erasmus Medical Center at 1 site in Netherlands.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 15 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 29 Mar 2021. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Netherlands. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Composite rate of major- and minor vascular complications according to VARC-2 (time frame: Between transcatheter aortic valve implantation and 30 days follow-up). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 Mar 2021.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in