Assessing the Accuracy of the OptoWire DeuxTM in a Wire to Wire Comparison

A study testing Drift assessment of OptoWire Deux FFR wire (1) and Drift assessment of OptoWire Deux FFR wire (2) in people with Coronary Artery Disease and Coronary Stenosis, run by Centre hospitalier de l'Université de Montréal (CHUM) at 1 site in Canada.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The goal of the ACCURACY study is to assess the differences, if any, in FFR measurements made by the OptoWire Deux FFR guidewire by comparison of simultaneous data of two different OptoWire DeuxTM guidewires (group 1). Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Drift assessment of OptoWire Deux FFR wire (1) and Drift assessment of OptoWire Deux FFR wire (2)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
45 participants
Where
1 siteCanada
Study dates
1 Feb 2019to 31 Mar 2020
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Single de novo coronary lesion or in-stent restenosis lesion with an operator assessed reference diameter ≥2.0 mm requiring FFR measurement based on the operator's clinical judgment

Who cannot join

  • Patients with ST-segment-elevation myocardial infarction (STEMI), culprit lesion of non-ST-segment-elevation myocardial infarction (NSTEMI), New York Heart Association class IV heart failure, suspected or visible thrombus, dissection or excessive calcification or tortuosity in the target vessel, or a stenosis in a bypass graft will be excluded.

Trial locations and contacts

1 site in 1 country.

Canada1 site
  • Centre Hospitalier de l'Université de Montréal

    Montreal, Quebec, H2X0C1

Other trials in Canada

About this study

The goal of the ACCURACY study is to assess the differences, if any, in FFR measurements made by the OptoWire Deux FFR guidewire by comparison of simultaneous data of two different OptoWire DeuxTM guidewires (group 1). In addition, the investigators will compare (group 2) the FFR measurements obtained from an OptoWire Deux FFR guidewire and compare it to the FFR measurement by a VERRATA-TM guidewire to assess coronary stenosis in the routine clinical practice.

Read the detailed description

This is a single center, prospective, non-blinded clinical investigation enrolling consecutive patients with coronary lesion candidate for FFR assessment. The study aim to assess the differences, if any, in FFR measurements made by the OptoWire Deux FFR guidewire by comparison of simultaneous data of two different OptoWire DeuxTM guidewires (group 1, n=30). In addition, The investigators will compare (group 2, n=15) the FFR measurements obtained from an OptoWire Deux FFR guidewire and compare it to the FFR measurement by a VERRATA-TM guidewire to assess coronary stenosis in the routine clinical practice. The clinical investigation will be conducted in the Centre Hospitalier de l'Université de Montréal (CHUM). No clinical follow-up is requested after the end of the procedure.

Being tested
Drift assessment of OptoWire Deux FFR wire (1), Drift assessment of OptoWire Deux FFR wire (2)
Medical subject headings
Coronary Artery Disease, Coronary Stenosis, Atherosclerosis, Angina, Stable, Angina, Unstable, Non-ST Elevated Myocardial Infarction

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Drift assessment of OptoWire Deux FFR wire (1)Device

    Simultaneous data of two different OptoWire DeuxTM guidewires (group 1) to assess a single coronary stenosis and detect any difference if any.

  • Drift assessment of OptoWire Deux FFR wire (2)Device

    Simultaneous data of one Optowire Deux TM guide wires and one VERRATA-TM FFR wire (group 2) to assess a single coronary stenosis and detect any difference if any.

Study groups in NCT03815032
Study groupRoleWhat they receive
Optowire Deux FFR assessment (1)ExperimentalA total of 45 consecutive patients will be recruited: group 1 (n=30): To assess the differences in FFR measurements (drift) made by the OptoWire Deux FFRTM guidewire by comparison of simultaneous data of two different OptoWire DeuxTM guidewires
Receives: Device: Drift assessment of OptoWire Deux FFR wire (1)
Optowire Deux FFR assessment (2)Experimentalgroup 2 (n=15): To assess the differences in FFR measurements (drift) obtained from an OptoWire DeuxTM FFR guidewire and compare it to the FFR measurement by a VERRATATM guidewire
Receives: Device: Drift assessment of OptoWire Deux FFR wire (2)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. delta FFR

    To assess the magnitude of reading delta from wire to wire in a percutaneous coronary intervention

    Measured: Day 1

Secondary outcomes (5)
  1. Drift recording

    The rate of significant drift, defined as Pd/Pa <0.97 or >1.03

    Measured: Day 1

  2. Delta from guidewire to guidewire

    Assess the magnitude of reading delta from guidewire to guidewire prior to equalization.

    Measured: Day 1

  3. Stents

    The number of stents used.

    Measured: Day 1

  4. Stents on FFR wire

    The number of stents placed over an OptoWire DeuxTM guidewire.

    Measured: Day 1

  5. Workhorse guidewire

    Number of Workhorse guidewire used.

    Measured: Day 1

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted24 Jan 2019
  2. Study start1 Feb 2019
  3. Primary completion30 Jan 2020
  4. Study completion31 Mar 2020

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Non-randomised
Intervention model
Single group
Masking
None (open label)
Enrolment
45 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03815032
Sponsor's protocol ID
18.238
Acronym
ACCURACY
Status last verified
Jan 2019
First submitted
7 Jan 2019
Last updated
20 Jul 2020
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No

Publications

  • Pothineni NV, Shah NN, Rochlani Y, Nairooz R, Raina S, Leesar MA, Uretsky BF, Hakeem A. U.S. Trends in Inpatient Utilization of Fractional Flow Reserve and Percutaneous Coronary Intervention. J Am Coll Cardiol. 2016 Feb 16;67(6):732-733. doi: 10.1016/j.jacc.2015.11.042. No abstract available.

    PubMed 26868697
  • Fearon WF. Percutaneous coronary intervention should be guided by fractional flow reserve measurement. Circulation. 2014 May 6;129(18):1860-70. doi: 10.1161/CIRCULATIONAHA.113.004300. No abstract available.

    PubMed 24799502

Questions about this trial

What is this clinical trial studying?

A study testing Drift assessment of OptoWire Deux FFR wire (1) and Drift assessment of OptoWire Deux FFR wire (2) in people with Coronary Artery Disease and Coronary Stenosis, run by Centre hospitalier de l'Université de Montréal (CHUM) at 1 site in Canada.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 20 Jul 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

delta FFR (time frame: Day 1). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03815032, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 20 Jul 2020.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.