Surgical Site InfectionPALEXISNCT03820648
Wound Protector Dual-ring Alexis® in Pancreaticoduodenectomy
A study testing Alexis and Standard 3M™ Steri-Drape 2 in people with Surgical Site Infection, run by Azienda Ospedaliera Universitaria Integrata Verona at 1 site in Italy.
Trial summary
Surgical site infection (SSI) is a leading cause of preventable morbidity and mortality in North America and worldwide. This condition has consistently been reported to account for up to 25% of all healthcare-associated infections. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Surgical Site Infection
- What is being tested?
- Alexis and Standard 3M™ Steri-Drape 2
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 212 participants
- Where
- 1 siteItaly
- Study dates
- 7 Sep 2017to 9 Dec 2019
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Scheduled for elective PD
- Age ≥ 18 years
- Ability of the subject to understand character and individual consequences of the clinical trial
- Written informed consent
Who cannot join
- Under 18 years of age
- Unable to sign informed consent
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Wound Protector Dual-ring Alexis® in Pancreaticoduodenectomy: a Randomized Single-blind Controlled Clinical Trial
Surgical site infection (SSI) is a leading cause of preventable morbidity and mortality in North America and worldwide. This condition has consistently been reported to account for up to 25% of all healthcare-associated infections. In a cost analysis, SSIs post-pancreaticoduodenectomy (PD) dramatically increases the treatment costs. More importantly, postoperative wound infections delay postoperative adjuvant chemotherapy, which is indicated in the majority of patients undergoing PD for pancreatic cancer. Protective covers or 'wound protectors' are hypothesized to be an improvement over adhesive membrane barriers as they are believed to reduce intraoperative contamination while concomitantly preserving the temperature and humidity of the surgical wound. The aim of this study is to assess if the use of wound protector can reduce the wound infection rate in patients undergoing to PD.
Read the detailed description
Surgical site infection (SSI) is a leading cause of preventable morbidity and mortality in North America and worldwide. This condition has consistently been reported to account for up to 25% of all healthcare-associated infections. Prolonged hospitalization, more frequent hospital re-admissions after surgery and a greater than twofold increase in costs and mortality have consistently been associated with this condition over the past decade. The SSI is associated with an increased risk of postsurgical pain, poor wound healing and aesthetic results and an increased risk of incisional hernias. The literature shows an incidence rate of SSI at 30 days after surgery that reaches 51% of cases. In particular, the incidence of wound infection is 15%. In our experience, the rate of wound infection in patients undergoing Pancreaticoduodenectomy (PD) is 10%.
SSI is an infectious process that is localized to surgical incision level and it is classified as being either incisional or organ/space. Incisional SSI is further divided into those involving only skin and subcutaneous tissue (superficial incisional SSI) and those involving deeper soft tissues of the incision (deep incisional SSI).
In a cost analysis, SSIs post-PD dramatically increases the treatment costs. More importantly, postoperative wound infections delay postoperative adjuvant chemotherapy, which is indicated in the majority of patients undergoing PD for pancreatic cancer. During recent years there is also an increasing incidence of antibiotic-resistant pathogens in hospitals, so several studies have suggested primary or secondary prevention strategies to reduce SSI rate. In order to minimize the risk of SSI, various measures of perioperative care have already been adopted, including the cleaning of the skin, the hair removal of the intervention area, the prevention of intraoperative hypothermia and perioperative antibiotic therapy. However there are few studies on the effectiveness of surgical procedures for primary prevention to reduce the contamination in the surgical site, especially in patients undergoing major gastrointestinal surgery. The surgical procedures classified as contaminated or dirty (with a higher bacterial load within the surgical site and/or regarding gastrointestinal or biliary tracts) remain associated with an increased risk of SSI, about two times, compared to the interventions classified as clean or clean-contaminated. The PD is classified as surgery contaminated / dirty.
The use of adhesive membrane barriers over the skin of the surgical site emerged 50 years ago as a possible solution to minimize endogenous cross-contamination during surgery. The initial idea relied on the principle of reducing exposure of the surgical site to bacteria inherent in the surrounding skin or to airborne bacteria in the operating room. Major applicability was expected in clean surgeries, where the skin is considered the main source of bacteria. Unfortunately, however, no evidence in support of plastic adhesive drapes was found in a recently updated systematic review of randomized controlled trials (RCTs) including five studies and 3082 patients. In fact, a 23% increase in the risk of SSI was found in the group that received adhesive drapes. In the 1960s, other devices were described and then developed based on the concept of combining a non-traumatic surgical wound retractor with a protective membrane covering of the incisional margin in abdominal surgeries. Such protective covers or 'wound protectors' (WP) were hypothesized to be an improvement over adhesive membrane barriers as they were believed to reduce intraoperative contamination while concomitantly preserving the temperature and humidity of the surgical wound. In support of this hypothesis, early studies demonstrated reduced exposure of the surgical wound to enteric bacteria at the end of gastrointestinal operations. These results were further supported by several RCTs, which demonstrated that wound protectors were efficacious in reducing the incidence of incisional SSI as compared to usual care in patients undergoing gastrointestinal surgeries. A recently meta-analysis of RCTs on the WP enrolled 6 studies and 1008 patients, finding that the pooled estimated risk of SSI among patients fitted with wound protectors during surgery was 0.55 (95% CI 0.31 to 0.98) times the pooled estimated risk of SSI in control groups.
The aim of this study is to assess if the use of WP can reduce the wound infection rate in patients undergoing to PD.
- Conditions
- Surgical Site Infection
- Being tested
- Alexis, Standard 3M™ Steri-Drape 2
- Medical subject headings
- Surgical Wound Infection
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
AlexisDevice
The Alexis® (Applied Medical) is a surgical device indicated for use in retracting and protecting an incision during laparoscopic or open surgery. It is intended to allow the surgeon to access through an atraumatic circumferentially 360 degrees retracted wound that provides maximum exposure with minimum incision size. Further, once positioned, the Alexis Wound Retractor is intended to protect against wound contamination.The device will be manufactured in five sizes, extra-small, small, medium, medium-large and large. The Alexis Wound Retractor has been found non-toxic and non-irritant when tested in accordance with ISO 10993, Part 1: Biological Evaluation of Medical Devices. The materials used in the manufacturing of the Alexis Wound Retractor have been tested in accordance with applicable standards and was determined to pass tensile strength, elongation, (ASTM D 412) and Tear Strength (ASTM D 624). Functional performance testing has been completed and has passed the required testing.
Standard 3M™ Steri-Drape 2Device
Standard 3M™ Steri-Drape 2 is a standard drape applicated on the skin of the patient before the surgical incision.
| Study group | Role | What they receive |
|---|---|---|
| Alexis® device | Experimental | In this group, we will be used WP dual-ring Alexis® (Figure 1). The Alexis® 's size will be decided on the basis of abdominal incision (Alexis® X-Large or Alexis® XX-Large will be used for 11-17cm or 17-25 cm incision length respectively) Receives: Device: Alexis |
| Standard 3M™ Steri-Drape 2 | Active comparator | In this group, we will be used Standard 3M™ Steri-Drape 2 Receives: Device: Standard 3M™ Steri-Drape 2 |
What is being measured
The primary outcome is the main question the study is designed to answer.
Surgical site infection
Number of SSI onset in patients submitted to PD until the 30th day postoperative. This endpoint will be compared between the two groups.
Measured: 30th day postoperative
Secondary outcomes (3)
Device resistance
Number intraoperative device rupture in both groups. It will be also recorded the number of device lesions seen at the end of the surgical operation.
Measured: Intraoperative
Treatment costs related to increased hospital stays due to SSI
Number of additional days to the average hospital stays (7 days) of the patients submitted to PD at our Institute, related to the onset of SSI until the 30th day postoperative
Measured: 30th day postoperative
Costs related to the use of additional antibiotics administered for the treatment of SSI
Evaluation of the total costs of the additional antibiotic therapy administered for the treatment of SSI, developed within the 30th day postoperative, in the two patient groups. It will be considered like the ex-factory price of the drug.
Measured: 30th day postoperative
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted29 Jan 2019
- Study start7 Sep 2017
- Primary completion9 Dec 2019
- Study completion9 Dec 2019
Why it stopped: no differences between the groups at the interim analysis
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (1)Papers the sponsor has linked to this study.
- Other trials for Surgical Site InfectionStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Model description
- The study is an RCT, single-blinded, conducts in patients with cancer submitted to PD (1:1). In the experimental group, we will use the dual-ring WP Alexis (Applied Medical, Rancho Santa Margarita, California, USA), while in the control group we will use the standard 3M™ Steri-Drape 2. There is planned a clinical visit of follow-up on the 30th day from the operation day (as in clinical practice).
- Masking
- Single blind
- Who is masked
- Participant
- Enrolment
- 212 participants (actual)
Sponsor and investigators
- Lead sponsor
- Azienda Ospedaliera Universitaria Integrata Verona
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03820648
- Sponsor's protocol ID
- CE 1369 cesc
- Acronym
- PALEXIS
- Status last verified
- Dec 2019
- First submitted
- 26 Sep 2018
- Last updated
- 14 Jan 2020
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
De Pastena M, Marchegiani G, Paiella S, Fontana M, Esposito A, Casetti L, Secchettin E, Manzini G, Bassi C, Salvia R. Use of an intraoperative wound protector to prevent surgical-site infection after pancreatoduodenectomy: randomized clinical trial. Br J Surg. 2020 Aug;107(9):1107-1113. doi: 10.1002/bjs.11527. Epub 2020 Mar 12.
PubMed 32162321
Study at a glance
From the registry record, last updated by the sponsor on 14 Jan 2020. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Wound Protector Dual-ring Alexis® in Pancreaticoduodenectomy: a Randomized Single-blind Controlled Clinical Trial
- ClinicalTrials.gov ID
- NCT03820648
- Acronym / sponsor ID
- PALEXIS / CE 1369 cesc
- Conditions
- Surgical Site Infection
- Study type
- Interventional
- Recruitment status
- TerminatedReason stopped: no differences between the groups at the interim analysis
- Enrolment
- 212 participants (actual)
- Lead sponsor
- Azienda Ospedaliera Universitaria Integrata VeronaUniversity, hospital or other
- Study start
- 7 Sep 2017 (actual)
- Primary completion
- 9 Dec 2019 (actual)
- Study completion
- 9 Dec 2019 (actual)
- First posted
- 29 Jan 2019 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Surgical site infection (SSI) is a leading cause of preventable morbidity and mortality in North America and worldwide. This condition has consistently been reported to account for up to 25% of all healthcare-associated infections. In a cost analysis, SSIs post-pancreaticoduodenectomy (PD) dramatically increases the treatment costs. More importantly, postoperative wound infections delay postoperative adjuvant chemotherapy, which is indicated in the majority of patients undergoing PD for pancreatic cancer. Protective covers or 'wound protectors' are hypothesized to be an improvement over adhesive membrane barriers as they are believed to reduce intraoperative contamination while concomitantly preserving the temperature and humidity of the surgical wound. The aim of this study is to assess if the use of wound protector can reduce the wound infection rate in patients undergoing to PD.
Detailed description
Surgical site infection (SSI) is a leading cause of preventable morbidity and mortality in North America and worldwide. This condition has consistently been reported to account for up to 25% of all healthcare-associated infections. Prolonged hospitalization, more frequent hospital re-admissions after surgery and a greater than twofold increase in costs and mortality have consistently been associated with this condition over the past decade. The SSI is associated with an increased risk of postsurgical pain, poor wound healing and aesthetic results and an increased risk of incisional hernias. The literature shows an incidence rate of SSI at 30 days after surgery that reaches 51% of cases. In particular, the incidence of wound infection is 15%. In our experience, the rate of wound infection in patients undergoing Pancreaticoduodenectomy (PD) is 10%.
SSI is an infectious process that is localized to surgical incision level and it is classified as being either incisional or organ/space. Incisional SSI is further divided into those involving only skin and subcutaneous tissue (superficial incisional SSI) and those involving deeper soft tissues of the incision (deep incisional SSI).
In a cost analysis, SSIs post-PD dramatically increases the treatment costs. More importantly, postoperative wound infections delay postoperative adjuvant chemotherapy, which is indicated in the majority of patients undergoing PD for pancreatic cancer. During recent years there is also an increasing incidence of antibiotic-resistant pathogens in hospitals, so several studies have suggested primary or secondary prevention strategies to reduce SSI rate. In order to minimize the risk of SSI, various measures of perioperative care have already been adopted, including the cleaning of the skin, the hair removal of the intervention area, the prevention of intraoperative hypothermia and perioperative antibiotic therapy. However there are few studies on the effectiveness of surgical procedures for primary prevention to reduce the contamination in the surgical site, especially in patients undergoing major gastrointestinal surgery. The surgical procedures classified as contaminated or dirty (with a higher bacterial load within the surgical site and/or regarding gastrointestinal or biliary tracts) remain associated with an increased risk of SSI, about two times, compared to the interventions classified as clean or clean-contaminated. The PD is classified as surgery contaminated / dirty.
The use of adhesive membrane barriers over the skin of the surgical site emerged 50 years ago as a possible solution to minimize endogenous cross-contamination during surgery. The initial idea relied on the principle of reducing exposure of the surgical site to bacteria inherent in the surrounding skin or to airborne bacteria in the operating room. Major applicability was expected in clean surgeries, where the skin is considered the main source of bacteria. Unfortunately, however, no evidence in support of plastic adhesive drapes was found in a recently updated systematic review of randomized controlled trials (RCTs) including five studies and 3082 patients. In fact, a 23% increase in the risk of SSI was found in the group that received adhesive drapes. In the 1960s, other devices were described and then developed based on the concept of combining a non-traumatic surgical wound retractor with a protective membrane covering of the incisional margin in abdominal surgeries. Such protective covers or 'wound protectors' (WP) were hypothesized to be an improvement over adhesive membrane barriers as they were believed to reduce intraoperative contamination while concomitantly preserving the temperature and humidity of the surgical wound. In support of this hypothesis, early studies demonstrated reduced exposure of the surgical wound to enteric bacteria at the end of gastrointestinal operations. These results were further supported by several RCTs, which demonstrated that wound protectors were efficacious in reducing the incidence of incisional SSI as compared to usual care in patients undergoing gastrointestinal surgeries. A recently meta-analysis of RCTs on the WP enrolled 6 studies and 1008 patients, finding that the pooled estimated risk of SSI among patients fitted with wound protectors during surgery was 0.55 (95% CI 0.31 to 0.98) times the pooled estimated risk of SSI in control groups.
The aim of this study is to assess if the use of WP can reduce the wound infection rate in patients undergoing to PD.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (participant)
- Number of arms
- 2
- Model description
- The study is an RCT, single-blinded, conducts in patients with cancer submitted to PD (1:1). In the experimental group, we will use the dual-ring WP Alexis (Applied Medical, Rancho Santa Margarita, California, USA), while in the control group we will use the standard 3M™ Steri-Drape 2. There is planned a clinical visit of follow-up on the 30th day from the operation day (as in clinical practice).
| Arm | Type | Receives |
|---|---|---|
| Alexis® device | Experimental | Device: AlexisIn this group, we will be used WP dual-ring Alexis® (Figure 1). The Alexis® 's size will be decided on the basis of abdominal incision (Alexis® X-Large or Alexis® XX-Large will be used for 11-17cm or 17-25 cm incision length respectively) |
| Standard 3M™ Steri-Drape 2 | Active comparator | Device: Standard 3M™ Steri-Drape 2In this group, we will be used Standard 3M™ Steri-Drape 2 |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (4 listed)
- Scheduled for elective PD
- Age ≥ 18 years
- Ability of the subject to understand character and individual consequences of the clinical trial
- Written informed consent
Key exclusion criteria (2 listed)
- Under 18 years of age
- Unable to sign informed consent
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| AlexisThe Alexis® (Applied Medical) is a surgical device indicated for use in retracting and protecting an incision during laparoscopic or open surgery. It is intended to allow the surgeon to access through an atraumatic circumferentially 360 degrees retracted wound that provides maximum exposure with minimum incision size. Further, once positioned, the Alexis Wound Retractor is intended to protect against wound contamination.The device will be manufactured in five sizes, extra-small, small, medium, medium-large and large. The Alexis Wound Retractor has been found non-toxic and non-irritant when tested in accordance with ISO 10993, Part 1: Biological Evaluation of Medical Devices. The materials used in the manufacturing of the Alexis Wound Retractor have been tested in accordance with applicable standards and was determined to pass tensile strength, elongation, (ASTM D 412) and Tear Strength (ASTM D 624). Functional performance testing has been completed and has passed the required testing. | Device | Alexis® device |
| Standard 3M™ Steri-Drape 2Standard 3M™ Steri-Drape 2 is a standard drape applicated on the skin of the patient before the surgical incision. | Device | Standard 3M™ Steri-Drape 2 |
Primary outcome
Surgical site infection
Time frame: 30th day postoperative
Number of SSI onset in patients submitted to PD until the 30th day postoperative. This endpoint will be compared between the two groups.
3 secondary outcomes
Device resistance
Time frame: Intraoperative
Treatment costs related to increased hospital stays due to SSI
Time frame: 30th day postoperative
Costs related to the use of additional antibiotics administered for the treatment of SSI
Time frame: 30th day postoperative
Results and safety
The study was stopped early (reason given: no differences between the groups at the interim analysis). Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 14 Jan 2020.
- Derived from this study: PubMed 32162321De Pastena M, Marchegiani G, Paiella S, Fontana M, Esposito A, Casetti L, Secchettin E, Manzini G, Bassi C, Salvia R. Use of an intraoperative wound protector to prevent surgical-site infection after pancreatoduodenectomy: randomized clinical trial. Br J Surg. 2020 Aug;107(9):1107-1113. doi: 10.1002/bjs.11527. Epub 2020 Mar 12.
- Individual participant dataSharing planned: No
Related trials for Surgical Site Infection
Not yet recruitingObservational study
Pilot Study on the Effectiveness and Safety of OPTILENE® SILVER MESH ELASTIC in Prevention of Surgical Site Infection (SSI) and Incisional Hernia (IH)
Abdominal Aortic Aneurysm, Morbid Obesity
RecruitingPhase 2
A Single Arm Phase II Trial in p16-positive Oropharynx Cancer of Selective Dose De-escalation of nodAl VolumEs at Minimal Risk and Primary Site Disease (SAVED)
Head and Neck Cancer, Head and Neck Squamous Cell Cancer
Recruiting
Safety and Efficacy of NTP in Thyroid Surgery: Pilot Study on Morbidity Prevention and Adjuvant Oncological Control
Thyroid Diseases, Wound Healing
RecruitingObservational study
Novosyn® CHD vs Polyglactin 910 Suture to Close Wounds After Emergency or Elective Laparotomy or Laparoscopic Surgery
Surgical Site Infection
Not yet recruiting
Safety Assessment of Placing a Single Dental Implant Without Antibiotic Prophylaxis in Simple Cases: A Pilot Study
Tooth Loss and Rehabillitation, Dental Implant Failure
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Alexis and Standard 3M™ Steri-Drape 2 in people with Surgical Site Infection, run by Azienda Ospedaliera Universitaria Integrata Verona at 1 site in Italy.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: stopped early, as of the sponsor's last update on 14 Jan 2020. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study was stopped early (reason given: no differences between the groups at the interim analysis). Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Surgical site infection (time frame: 30th day postoperative). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT03820648, which also lists 1 linked publication.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 14 Jan 2020.