AzTrials
AzTrials

Arteriovenous Graft StenosisNCT03839264

Optimal Screening Program in Detecting Stenosis and Predicting Thrombosis in Hemodialysis Graft

An observational study of Arteriovenous Graft Stenosis and Arteriovenous Graft Thrombosis, run by Azienda Ospedaliera Universitaria Integrata Verona at 1 site in Italy.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

A well-functioning vascular access is essential for providing adequate life-sustaining treatment in patients with end stage renal disease on maintenance hemodialysis. The preferred long-term vascular access is the arteriovenous fistula (AVF), which is created using the vessels of the patient by surgically connecting… Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Graft stenosis and thrombosis
How many people
48 participants
Where
1 siteItaly
Study dates
1 Aug 2011to 30 Sep 2018
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Haemodialysis patients with an AV graft as vascular access

Who may be able to join

  • All the patients with a polytetrafluroethylene (PTFE) graft as haemodialysis vascular access who were treated at the haemodialysis Unit of the Polyclinic of B.go Roma Hospital in Verona during the recruitment period and who agreed to take part at the study

Who cannot join

  • No one.

Trial locations and contacts

1 site in 1 country.

Italy1 site
  • Azienda Ospedaliera Integrata di Verona - Policlinico Borgo Roma

    Verona, 37135

Other trials in Italy

About this study

Official title: Diagnostic Accuracy of the Available Screening Tools in Detecting Stenosis and Predicting Incipient Thrombosis in Arteriovenous Graft for Hemodialysis: a Comparative Analysis

A well-functioning vascular access is essential for providing adequate life-sustaining treatment in patients with end stage renal disease on maintenance hemodialysis. The preferred long-term vascular access is the arteriovenous fistula (AVF), which is created using the vessels of the patient by surgically connecting an artery with a superficial vein to increase the blood flow (Qa) in the venous system, which will dilate allowing the insertion of two needles, one to carry the blood to the dialyzer, and the other to return the cleansed blood to the body with the aid of a dialysis machine. Unfortunately, the high prevalence of vascular disease of the hemodialysis patients make difficult to create an adequate AVF in as many as 20 to 60% of the patients.In these persons, a valid alternative is the arteriovenous graft: in graft method an artery is surgically connected to a vein with a short piece of synthetic soft tube which is implanted under the skin. Needles are inserted in the graft during the dialysis treatment. Compared to an AV, however, graft is at higher risk of complications. The most frequent complication is thrombosis (i.e. the formation of blood clot inside the graft). Usually, thrombosis is the consequence of an underlying significant stenosis (i.e. a greater than 50% narrowing of the vessel or graft lumen by comparison with the lumen of a normal adjacent vessel or graft) and its hemodynamic consequences of decreasing the access blood flow (Qa) and/or increasing pressure within the graft. Therefore, all vascular access guidelines recommend regular noninvasive screening programs of grafts for timely identification of a stenosis associated with some type of functional or hemodynamic impairment, because its repair may prevent thrombosis and lengthen the useful life of the access. Screening methods include clinical monitoring and surveillance, which uses special equipment either to assess the hemodynamic consequences of stenosis by measuring Qa and static venous intra-access pressure ratio (VAPR) or to visualize the stenosis by means of duplex ultrasound (DU). Guidelines also state that there is insufficient evidence to prefer one method to another due to the lack of adequate comparative studies. The purpose of our study is to identify an optimal screening program for stenosis detection and elective repair by comparing the diagnostic performance for stenosis and incipient thrombosis of all the available screening tools in the same graft population

Read the detailed description

A well-functioning vascular access (a system that allows the blood of the patient to leave the body, be brought to the artificial kidney or dialyzer to be cleaned and return the cleansed blood to the body) is essential for providing adequate life-sustaining treatment in patients with end stage renal disease on maintenance haemodialysis.

The preferred long-term vascular access is the arteriovenous fistula (AVF), which is created using the vessels of the patient by surgically connecting an artery with a superficial vein to increase the blood flow (Qa) in the venous system, which after few weeks will dilate (maturation) allowing the insertion of two needles, one to carry the blood to the dialyzer (arterial needle), and the other to return the cleansed blood to the body (venous needle) with the aid of a dialysis machine, equipped with a blood pump and pressure sensors at the level of the "arterial" and "venous" needle to monitor for needles dislodgment.

Unfortunately, the high prevalence of vascular disease of the haemodialysis patients makes difficult to create an adequate AVF in as many as 20 to 60% of the patients.

In these persons, a valid alternative is the arteriovenous graft: in graft method an artery is surgically connected to a vein with a short piece of synthetic soft tube which is implanted under the skin. Needles are inserted in the graft during the dialysis treatment.

Compared to an AV, however, graft is at higher risk of complications. The most frequent and feared complication is thrombosis (i.e. the formation of blood clot inside the graft).

Usually, thrombosis is the consequence of an underlying stenosis (i.e. a greater than 50% narrowing of the vessel or graft lumen by comparison with the lumen of a normal adjacent vessel or graft due to the thickening of the vessels and/or the graft wall) and its hemodynamic consequences of decreasing the access blood flow (Qa) and/or increasing pressure within the graft. Less frequently thrombosis occurs in the absence of significant stenosis and may be triggered by a drop in the patient's arterial blood pressure (hypotension).

All vascular access guidelines recommend regular non-invasive screening programs of grafts for timely identification of a stenosis associated with some type of functional or hemodynamic impairment, because its repair may prevent thrombosis and lengthen the useful life of the access.

Non-invasive screening methods include clinical monitoring (i.e. noting signs of access dysfunction during the haemodialysis session) and surveillance, which uses special equipment either to assess the hemodynamic consequences of stenosis by measuring Qa and static venous intra-access pressure ratio (VAPR) or to visualize the stenosis by means of duplex ultrasound (DU).

In graft, all guidelines have opted for surveillance. However, they also state that there is insufficient evidence to prefer one technique to another because of the lack of adequate comparative studies.

Indeed, the great majority of the studies have evaluated the ability of detecting stenosis and predicting incipient thrombosis (within 1 to 3 months) by one surveillance method, and very few have compared two-to-three techniques at the best (1).

The purpose of the investigators was to compare in the same graft population the diagnostic performance of all the currently available screening tools in detecting stenosis and predicting incipient thrombosis (to identify the best criteria for elective stenosis repair).

The primary aim of the study was to identify an optimal screening program to reduce the risk of thrombosis in graft by assessing the diagnostic accuracy (i.e. sensitivity, false positive rate, positive and negative predictive value, and area under the receiver operator curve) of all the available screening tools and the occurrence of acute hypotension and identify the best threshold/s for continuous variables in a) detecting stenosis, b) predicting incipient thrombosis (within a 4-month period following graft assessment for stenosis).

The following screening methods will be tested:

  1. Monitoring: monitoring was considered positive when signs of graft dysfunction were noted during dialysis (difficult cannulation, aspiration of clots, inability to achieve the prescribed dialysis pump blood flow (Qb), excessive post-dialysis bleeding) or a >0.3 drop in single pool dialysis dose was documented;
  2. Dynamic pressures: pressures were measured in the initial 5 minutes of dialysis, using 15 G needles and detected by the dialysis machine using the pressure sensors connected with the "arterial" (dynamic arterial pressure in mmHg: dAP) and "venous" needle (dynamic venous pressure in mmHg: dVP) at a standard Qb 250 ml/min. dAP was expressed as the ratio with Qb (dAP/Qb, in mmHg/ml/min);
  3. Derived static intra-access venous pressure ratio (VAPR): was obtained in the initial 5 minutes of dialysis by the dVP, Qb, haematocrit and systemic systolic and diastolic blood pressure values, according to literature in mmHg/mmHg;
  4. Access blood flow (Qa, in ml/min) was measured by the Ultrasound dilution method during dialysis (QaU) using the Transonic HD03 device, in the same dialysis session in which pressures were measured: each value is the mean of triplicate measurement;
  5. Duplex Ultrasound (DU) was performed just before dialysis or in a non-dialysis day, using the Logiq 7 device (General Electric, Milwaukee). Grayscale and color imaging of the of the whole access circuit (feeding artery, graft and draining veins) was performed in the longitudinal and transverse plane to assess the presence of stenosis. Each stenosis was graded with regard to: (1) location (by defining "inflow stenosis" any stenosis located at the feeding artery, the arterial anastomosis or intragraft upstream the cannulation area, and "outflow stenosis" any stenosis located intragraft downstream the cannulation area, at the venous anastomosis, or at the draining veins); and (2) percent lumen reduction, determined by the ratio of the minimal intraluminal diameter at the stenosis to the nearby normal vessel or graft segment using an electronic calliper: a stenosis was considered significant (StD) when the lumen reduction was > 50% and/or downstream spectral doppler peak velocity of systolic blood flow (PSV) was > 400 cm/sec. Measurement of Qa is made in a straight portion of the brachial artery in the mid-third of the upper arm. The diameter of the blood flow was measured directly on the vessel thanks to b-flow color technology. Sampling volume was placed in the centre of the lumen and in the longitudinal plane. Typically, measurements were obtained over a sequence of 3 to 5 cardiac cycles (to allow for time-averaged mean velocities, TAV). TAV was calculated directly by the device from a doppler spectral waveform by the duplex scanner system. The Qa (in ml/min) is calculated by the device as the product of the artery diameter and the TAV. The mean value of at least 3 separate measurements was reported.

Subsequently all grafts underwent the biplanar Digital Subtraction Angiography (DSA), our gold standard for stenosis detection. The access was visualized in its entirety from the feeding artery to the right atrium seeking for the presence of stenosis. Each stenosis was graded with regard to location and degree as outlined for DU and was considered significant (StA) when the lumen reduction was > 50%. To ensure blinding the investigator performing DSA was unaware of the results of the other screening strategies.

Secondary aims of the study were to assess:

  1. the relationship between Qa measurement by ultrasound dilution (QaU) and DU (QaD);
  2. the intra-assay variability of QaU and QaD measurements;
  3. The inter-assay variability of QaU, dAP/Qb, dVP, and VAPR measurements;
  4. the concordance of 2 different radiologists in detecting presence of significant stenosis (>50%) at DSA.
Being tested
Graft stenosis and thrombosis
Keywords
diagnostic accuracy, screening

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Graft stenosis and thrombosisDiagnostic test

Study groups in NCT03839264
Study groupRoleWhat they receive
Graft stenosis and thrombosisDiagnostic performance for stenosis at angiography of non invasive screening tools (duplex ultrasound, access blood flow (Qa), dynamic and static dialysis machine venous pressures, dynamic dialysis machine arterial pressure, and monitoring) and incipient thrombosis (within 4-month period) of the presence and degree of stenosis at angiography, non invasive screening techniques and acute hypotensive episode/s during the follow-up
Receives: Diagnostic Test: Graft stenosis and thrombosis

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Presence of a significant stenosis at DSA (yes/not)

    presence of a greater than 50% reduction in the vessel or graft lumen diameter by comparison with the lumen diameter of a normal adjacent vessel or graft in mm/mm.

    Measured: 1 hour

  2. Presence of significant stenosis at DU (yes/not)

    presence of a greater than 50% reduction in the vessel or graft lumen diameter by comparison with the lumen diameter of a normal adjacent vessel or graft in mm/mm and/or a peak systolic velocity > 400 cm/sec at the stenotic site

    Measured: 30 minutes

  3. Abnormal clinical monitoring (yes/not)

    signs of graft dysfunction noted during dialysis: difficult cannulation, aspiration of clots, inability to achieve the prescribed dialysis pump blood flow (Qb), excessive post-dialysis bleeding or a >0.3 drop in single pool dialysis dose

    Measured: 15 minutes

  4. Qa measured by ultrasound dilution: QaU (ml/min)

    Qa was measured by the Ultrasound dilution method during dialysis using the Transonic HD03 device, in the same dialysis session in which pressures were measured: each value is the mean of triplicate measurement

    Measured: 15 minutes

  5. Qa measured by DU: QaD (ml/min)

    Measurement of Qa is made in a straight portion of the brachial artery in the mid-third of the upper arm. The diameter of the blood flow was measured directly on the vessel thanks to b-flow color technology. Sampling volume was placed in the centre of the lumen and in the longitudinal plane. Typically, measurements were obtained over a sequence of 3 to 5 cardiac cycles (to allow for time-averaged mean velocities, TAV). TAV was calculated directly by the device from a doppler spectral waveform by the duplex scanner system. The Qa (in ml/min) is calculated by the device as the product of the artery diameter and the TAV. The mean value of at least 3 separate measurements was reported.

    Measured: 10 minutes

  6. Dynamic arterial pressure / dialysis pump blood flow: dAP/Qb (mmHg/ml/min)

    Dynamic arterial pressure (dAP) was measured in the initial 5 minutes of dialysis and detected by the dialysis machine using the pressure sensor connected with the "arterial" needle and expressed as the ratio with dialysis blood pump flow Qb.

    Measured: 5 minutes

  7. dynamic venous pressure: dVP (mmHg)

    Dynamic venous pressure (dVP) was measured in the initial 5 minutes of dialysis and detected by the dialysis machine using the pressure sensor connected with the "venous" needle

    Measured: 5 minutes

  8. Derived static venous pressure ratio: VAPR (mmHg/mmHg)

    obtained in the initial 5 minutes of dialysis by the dVP, Qb, haematocrit and systemic systolic and diastolic blood pressure values, according to literature in mmHg/mmHg

    Measured: 10 minutes

  9. occurrence of symptomatic acute hypotension during the follow up (yes/not)

    during the follow up an episode of acute symptomatic hypotension in the intra- and inter-dialytic interval was recorded. Hypotension was defined as a sudden fall of systemic blood pressure associated with one or more of fainting palpitation, nausea, blurred vision, feeling weak or cold

    Measured: 4 months

Secondary outcomes (4)
  1. correlation coefficient (r) between QaU and QaD measurements (ml/min / ml/mn)

    the correlation between the Qa values measured by ultrasound dilution and DU (ml of blood flowing within the access per minute, ml/min)

    Measured: 30 minutes

  2. Concordance for the presence of significant stenosis between two radiologists (yes/not)

    the concordance of radiologist 1 and radiologist 2 in detecting the presence of significant stenosis at DSA.

    Measured: 1 hour

  3. intra-assay coefficient of variation of QaU and QaD (%)

    the coefficient of variation was obtained by dividing the standard deviation by the mean value of multiple measurements

    Measured: 15 minutes

  4. inter-assay coefficient of variation of QaU, dAP/Qb,dVP and VAPR (%)

    the coefficient of variation was obtained by dividing the standard deviation by the mean value of multiple measurements obtained over 1 week period for dAP/Qb, dVP and VAPR and within 1 month period for QaU

    Measured: 1 month

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted15 Feb 2019
  2. Study start1 Aug 2011
  3. Primary completion30 May 2018
  4. Study completion30 Sep 2018

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Other
Enrolment
48 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03839264
Sponsor's protocol ID
AOVerona
Status last verified
Jan 2019
First submitted
29 Jun 2017
Last updated
15 Feb 2019
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Yes: The following data will be available to other researchers from professor Albino Poli on request: patient age, gender, comorbidities and time on dialysis; graft age, site, configuration and previous interventions; results of angiography and screening tools (duplex ultrasound, dialysis dynamic and static venous pressures, dialysis arterial pressure/blood pump flow, ultrasound dilution access blood flow, monitoring) and outcomes during the follow-up (symptomatic hypotension, graft potency, thrombosis).

Publications

  • Vascular Access 2006 Work Group. Clinical practice guidelines for vascular access. Am J Kidney Dis. 2006 Jul;48 Suppl 1:S176-247. doi: 10.1053/j.ajkd.2006.04.029. No abstract available.

    PubMed 16813989
  • Tordoir J, Canaud B, Haage P, Konner K, Basci A, Fouque D, Kooman J, Martin-Malo A, Pedrini L, Pizzarelli F, Tattersall J, Vennegoor M, Wanner C, ter Wee P, Vanholder R. EBPG on Vascular Access. Nephrol Dial Transplant. 2007 May;22 Suppl 2:ii88-117. doi: 10.1093/ndt/gfm021. No abstract available.

    PubMed 17507428
  • Polkinghorne K; Caring for Australians with Renal Impairment (CARI). The CARI guidelines. Vascular access surveillance. Nephrology (Carlton). 2008 Jul;13 Suppl 2:S1-11. doi: 10.1111/j.1440-1797.2008.00992.x. No abstract available.

    PubMed 18713118
  • Tessitore N, Bedogna V, Verlato G, Poli A. Clinical access assessment. J Vasc Access. 2014;15 Suppl 7:S20-7. doi: 10.5301/jva.5000242. Epub 2014 Apr 12.

    PubMed 24817450
  • Frinak S, Zasuwa G, Dunfee T, Besarab A, Yee J. Dynamic venous access pressure ratio test for hemodialysis access monitoring. Am J Kidney Dis. 2002 Oct;40(4):760-8. doi: 10.1053/ajkd.2002.35687.

    PubMed 12324911
  • Krivitski NM. Theory and validation of access flow measurement by dilution technique during hemodialysis. Kidney Int. 1995 Jul;48(1):244-50. doi: 10.1038/ki.1995.290.

    PubMed 7564085
  • Tessitore N, Bedogna V, Verlato G, Poli A. The rise and fall of access blood flow surveillance in arteriovenous fistulas. Semin Dial. 2014 Mar;27(2):108-18. doi: 10.1111/sdi.12187. Epub 2014 Feb 5.

    PubMed 24494667
  • Tessitore N, Bedogna V, Melilli E, Millardi D, Mansueto G, Lipari G, Mantovani W, Baggio E, Poli A, Lupo A. In search of an optimal bedside screening program for arteriovenous fistula stenosis. Clin J Am Soc Nephrol. 2011 Apr;6(4):819-26. doi: 10.2215/CJN.06220710. Epub 2011 Mar 31.

    PubMed 21454718

Questions about this trial

What is this clinical trial studying?

An observational study of Arteriovenous Graft Stenosis and Arteriovenous Graft Thrombosis, run by Azienda Ospedaliera Universitaria Integrata Verona at 1 site in Italy.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 15 Feb 2019. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Presence of a significant stenosis at DSA (yes/not) (time frame: 1 hour). The study lists 9 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03839264, which also lists 8 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 Feb 2019; AzTrials last refreshed its copy on 27 Oct 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in