AzTrials
AzTrials

Dorsal DisplacementNCT03848702

Nonoperative Treatment of Dorsally Dislocated Distal Radius Fractures in Adults With an Individualized 3D Printed Brace.

A study testing Distal radius fracture brace in people with Dorsal Displacement, run by VieCuri Medical Centre at 1 site in Netherlands.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Study design: Two consecutive prospective case series. Study population: Part 1 will enroll 10 healthy volunteers (50 years or older). Part 2 will enroll 10 elderly patients (50 years or older) with a dorsally displaced distal radius fracture (AO type 23-A-C) that is acceptably reduced. Read more about this study

Who is it for?
Ages 50 years and olderHealthy volunteers can take part
Conditions the study is for
Dorsal Displacement
What is being tested?
Distal radius fracture brace
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
15 participants
Where
1 siteNetherlands
Study dates
1 Jul 2017to 1 Jul 2018
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 50 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Part 1:
  • Age 50 years or older
  • Healthy volunteer without distal radius fracture
  • No restrictions in activities of daily living prior to enrolment*
  • Signed informed consent by participant * Participant should exercises complete self-control over urination and defecation, but use of incontinence material is allowed.
  • Part 2:
Show all 10Show fewer
  • Patients (50 years or older) with an acute**, unilateral distal radius fracture with dorsal displacement (AO type 23-A, B, or C) that is acceptably reduced (by simple closed reduction with vertical longitudinal traction)
  • No restrictions in activities of daily living pre-fracture*
  • Signed informed consent by patient
  • Participant should exercises complete self-control over urination and defecation, but use of incontinence material is allowed. ** Patients should report to the Emergency Department within 48h post-trauma.

Who cannot join

  • Part 1:
  • Preexisting anatomical deviation of the ipsi- or contralateral wrist
  • Conditions that affect function of the wrist or hand
  • Insufficient comprehension of the Dutch or language to understand the study documents
  • Participant unwilling or unable to comply with the study protocol and follow-up visit schedule
  • Known allergy for brace material (PLA or alternative)
Show all 15Show fewer
  • Part 2:
  • Preexisting anatomical deviation of the ipsi- or contralateral wrist
  • Additional traumatic injuries that affect treatment, rehabilitation, or function of the affected hand
  • Pathological, recurrent, or open fracture
  • Impaired wrist function pre-trauma at either wrist (e.g., arthrosis, rheumatoid disorder, or neurological disorder)
  • Bone disorder that may impair bone healing, excluding osteoporosis
  • Patient unwilling or unable to comply with the treatment protocol and follow-up visit schedule
  • Insufficient comprehension of the Dutch language to understand the study documents
  • Known allergy for brace material (PLA or alternative).

Trial locations and contacts

1 site in 1 country.

Netherlands1 site
  • VieCuri MC

    Venlo, Limburg, 5912 BL

Other trials in Netherlands

About this study

Official title: Nonoperative Treatment of Dorsally Dislocated Distal Radius Fractures in Adults With an Individualized 3D Printed Brace; a Tolerability Study in Healthy Volunteers and Patients (DRFB)

Study design: Two consecutive prospective case series. Study population: Part 1 will enroll 10 healthy volunteers (50 years or older). Part 2 will enroll 10 elderly patients (50 years or older) with a dorsally displaced distal radius fracture (AO type 23-A-C) that is acceptably reduced. In both parts, participants should have no restrictions in activities of daily living pre-fracture and no evident anatomical difference between both wrists.

Intervention:

Read more

Part 1: Participants will wear the brace continuously for one week. Part 2: Participants will wear the brace as treatment of the fracture for five weeks (instead of a plaster cast).

Main study parameters/endpoints: In parts 1 and 2, the primary outcome measure will be a Visual Analog Scale (VAS) score for wearing comfort. Secondary outcome measures are the occurrence of fracture redislocation (part 2 only), pain (VAS), inconvenience during NL61002.078.17 / DRFB-Tolerability Distal Radius Fracture Brace Tolerability Version number: 1.1, d.d. April 24, 2017 8 of 34 activities of daily living (Katz Index), and adverse reactions like pain, skin pressure, skin irritation/redness, sensibility issues, or device-related problems.

Read the detailed description

Rationale: Each year, approximately 34,500 adults in The Netherlands sustain a fracture of the distal radius (wrist fracture). Incidence peaks in the elderly. The currently preferred treatment is closed reduction and nonoperative treatment by immobilization in a plaster cast for 4-6 weeks. Surgery is only performed if closed reduction fails or redislocation occurs. Plaster immobilization is inconvenient and interferes with daily activities. More importantly, standard nonoperative treatment often fails; in 40-60% of the fractures, redislocation requires surgery. Surgical treatment is about 9 times more expensive than nonoperative treatment and not without risks. This project aims to develop an innovative nonoperative treatment option. The central idea is to produce a 3D-printed brace for the fractured wrist using a mirrored CT-scan of the contralateral, unfractured wrist as a model. This innovative approach has the advantage that it does not depend on surgery and provides a better and potentially more durable positioning than the currently applied plaster cast. We expect that redislocation will occur less frequently, so surgery may be avoided. In contrast to a traditional plaster cast, the newly developed brace is water resistant/repellant, lighter, and enables movement of the hand. It enables daily activities and improves independency in the elderly with a wrist fracture. The treatment has been successfully evaluated in an ex vivo model. The clinical implementation will follow a step-wise approach.

Objective: Part 1 aims to determine the tolerability of the 3D-printed brace when worn by healthy volunteers (50 years of order), performing their normal daily activities. In part 2, the objective is to determine tolerability of the 3D-printed brace in patients (50 years or older) with an extra-articular distal radius fracture with dorsal displacement, performing their normal daily activities.

Being tested
Distal radius fracture brace

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Distal radius fracture braceDevice

    The distal radius fracture brace is constructed from biocompatible materials (like polylactic acid; PLA) and the skin is protected by commercially available and approved waterproof padding (like Aquacast®). The major brace components are connected and reinforced with carbon rods and plastic bolt-nut connections. PLA is extensively used, for example in surgical implants, but also as biological alternative for plastics. Aquacast® is approved and used as waterproof padding in swim plaster. The biomechanical function of the distal radius brace has been tested successfully in an ex vivo setting (results to be published). The DRFB includes the distal forearm, wrist an base of the hand. The thumb and fingers are free and the DRFB provides more movement than classical casting.

Study groups in NCT03848702
Study groupRoleWhat they receive
Healthy volunteersExperimentalAll volunteers wore the DRFB
Receives: Device: Distal radius fracture brace
Patients with DRFExperimentalAll patients wore the DRFB
Receives: Device: Distal radius fracture brace

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. VAS score

    the primary outcome measure will be the change in 1 week (part 1) and over several weeks (part 2) on a 10-centimeter Visual Analog Scale (VAS) score for wearing comfort, in which 0 implies no comfort. and 10 implies extremely comfortable.

    Measured: Day 1, day 3 and 7 for part 1. Week 1, week 2 and week 5 for part 2

Secondary outcomes (4)
  1. Redislocation

    Redislocation is determined by the radiologic outcome:

    • Dorsal tilt > 15˚ on lateral X-ray
    • Volar tilt >20˚ on lateral X-ray
    • Shortening >5mm pertaining to the ulna in PA direction
    • Intraarticular step-off ≥ 2mm
    • Radial inclination < 15˚ in PA direction
    • Subluxation of the lunate According to guidelines on these parameters, redislocation is diagnosed.

    Measured: Week 1, week 2 and week 5 (only part 2)

  2. Pain Level

    Pain level caused by the brace will be determined using a 10-centimeter Visual Analog Scale (VAS), in which 0 implies no pain and 10 implies the worst possible pain.

    Measured: Day 1, day 3 and 7 for part 1. Week 1, week 2 and week 5 for part 2

  3. Inconvenience

    Inconvenience during activities of daily living using the Katz Index. The Katz Index asks for limitations in washing, clothing, indoor transfers, toilet visit, continence and eating. The range for the Katz index is 0 to 6 where 6 indicates full function, 4 indicates moderate impairment and 2 or less indicates severe functional impairment.

    Measured: Day 1, day 3 and 7 for part 1. Week 1, week 2 and week 5 for part 2

  4. Adverse reactions (pain, skin pressure, skin irritation/redness, sensibility issues or device-related problems

    Adverse reactions like pain, skin pressure, skin irritation/redness, sensibility issues, or device-related problems.

    Measured: Day 1, day 3 and 7 for part 1. Week 1, week 2 and week 5 for part 2

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted21 Feb 2019
  2. Study start1 Jul 2017
  3. Primary completion1 Jun 2018
  4. Study completion1 Jul 2018

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Randomised
Intervention model
Parallel groups
Model description
Two consecutive prospective case series to investigate brace feasibility.
Masking
Double blind
Who is masked
Participant, Care provider
Enrolment
15 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03848702
Sponsor's protocol ID
Nl61002.078.17
Status last verified
Feb 2019
First submitted
13 Feb 2019
Last updated
22 Feb 2019
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Janzing HMJ, Bessems SAM, Ligthart MAP, Van Lieshout EMM, Theeuwes HP, Barten DG, Verhofstad MHJ. Treatment of dorsally dislocated distal radius fractures with individualized 3D printed bracing: an exploratory study. 3D Print Med. 2020 Aug 18;6(1):22. doi: 10.1186/s41205-020-00075-4.

    PubMed 32809083

Questions about this trial

What is this clinical trial studying?

A study testing Distal radius fracture brace in people with Dorsal Displacement, run by VieCuri Medical Centre at 1 site in Netherlands.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 10 inclusion and 15 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 22 Feb 2019. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Netherlands. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

VAS score (time frame: Day 1, day 3 and 7 for part 1. Week 1, week 2 and week 5 for part 2). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03848702, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 22 Feb 2019; AzTrials last refreshed its copy on 8 Nov 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.