Jaw, EdentulousNCT03862482
Peri-Implant Healing Around Two Different Machined-Collar Designs After 25 Years of Function
A study testing Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1 (Configuration 1), Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2 (Configuration 2) and Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2 (Configuration 3) in people with Jaw, Edentulous, run by Université de Montréal at 1 site in Canada.
Trial summary
Brånemark System® dental implant osseointegration was introduced in 1965 as a novel approach to the replacement of missing teeth. Although this implant's machined, screw-shaped surface had excellent, well-documented, short- and long-term clinical success (Adell, R. Read more about this study
- Who is it for?
- Ages 48 to 82 yearsHealthy volunteers can take part
- Conditions the study is for
- Jaw, Edentulous
- What is being tested?
- Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1 (Configuration 1), Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2 (Configuration 2) and Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2 (Configuration 3)
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 22 participants
- Where
- 1 siteCanada
- Study dates
- 3 Jun 2019to 31 Dec 2019
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 48 to 82 years
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- non-smoker
- no temporomandibular joint (TMJ) disorder or facial pain
- having participated in the original study (1993 - 1996) at which time the minimum participants' age was 25 years and the maximum 56 years
Who cannot join
- refusal to sign informed consent documents
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Prospective Randomised Clinical Trial Evaluating the Effects of Two Different Implant Collar Designs on Peri-Implant Healing and Functional Osseointegration After 25 Years of Function With Full Arch Mandibular Prostheses
Brånemark System® dental implant osseointegration was introduced in 1965 as a novel approach to the replacement of missing teeth. Although this implant's machined, screw-shaped surface had excellent, well-documented, short- and long-term clinical success (Adell, R. 1987; Albrektsson, T., et al., 1981; Albrektsson, T., et al., 1986; Brånemark, P-I. , 1983; Brånemark P-I. 1987), newer implant designs were introduced that could enhance fusion of the implant to jaw bones, and better resist functional forces. One such implant, Screw-Vent®, has a fixture macro structure very similar to that of the Brånemark® implant. However, its fixture surface was acid etched (1-3µm) which could enhance osseointegration, and it has a longer, narrower machined internal-hex, friction-fit collar that could better resist functional forces.These characteristics should lead to less bone loss (Niznick, G. A., 1989). However, one clinical study (De Bruyen, et al., 1992) reported greater short-term bone loss with this implant compared to the Brånemark® implant, possibly due to its longer machined collar, and advocated long-term clinical studies. Therefore, this prospective within-subject clinical trial was undertaken in 1993 to first compare the Brånemark® implant with another implant, Swede-Vent®, a copy of the Brånemark® macro structure except for its fixture surface that was identically micro textured as that of Screw-Vent® by the same manufacturer. The effect on bone healing could then be compared between Brånemark®'s machined and Swede-Vent®'s micro textured fixture surfaces in the short- and long-terms. Since Screw-Vent®'s fixture surface was identically micro textured as that of Swede-Vent®, the investigators could then evaluate and compare the effects on bone healing of Screw-Vent®'s longer, narrower, internal-connection machined collar to the identical shorter, wider, external-connection machined collars of the Swede-Vent® and Brånemark® implants. All three two-part, platform-matched, parallel-wall implants were made of commercially pure titanium, had a very similar fixture macro design, were approved by the Food and Drug Administration (USA) and Health and Welfare Canada, and were commercially available in North America. Brånemark® and Screw-Vent® implants are still available, but the Swede-Vent® implant is not.
Read the detailed description
Therefore, between 1993 and 1996, 58 of 60 eligible participants had been recruited into a prospective, randomized clinical trial. This trial had been peer reviewed, had received ethical approval, and had taken place at the Université de Montréal's Faculty of Dental Medicine and its affiliated hospital dental department. Follow-up documentation occurred at one year, two years, and 15 to 20 years following prostheses attachment (ClinicalTrials Identification Number NCT01641198), and the results were published (Camarda, et al., 2018). The present study reports on data collected at the 25-year (24.6 ± 0.19 years, mean ± SE) follow-up (ClinicalTrials Identification Number NCT03862482), focusing specifically on the evaluation and comparison of the effects on peri-implant healing and functional osseointegration of the two different machined collar designs. That is to say, the identical shorter, wider, external-connection Brånemark® and Swede-Vent® collars versus the longer, narrower, internal-connection Screw-Vent® collar. Twenty-two of the original participants (41.5%, age 71.1 ± 1.2 years, 11 women, 110 implants) were enrolled into this study. All study procedures were performed in accordance with the Helsinki Declaration and its later amendments, and all participants signed informed consent documents prior to inclusion into this study.
- Conditions
- Jaw, Edentulous
- Being tested
- Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1 (Configuration 1), Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2 (Configuration 2), Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2 (Configuration 3)
- Keywords
- Dental Implants, Microtextured Fixture, Machined Collar
- Medical subject headings
- Jaw, Edentulous
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1 (Configuration 1)Device
Brånemark® implant placed at sites 2 (left medial) and 5 (right distal), Swede-Vent® implant placed at sites 1 (left distal) and 4 (right medial), Screw-Vent® implant placed at site 3 (para symphysis)
Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2 (Configuration 2)Device
Brånemark® implant placed at site 3 (para symphysis), Swede-Vent® implant placed at sites 2 (left medial) and 5 (right distal), Screw-Vent® implant placed at sites 1 (left distal) and 4 (right medial)
Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2 (Configuration 3)Device
Brånemark® implant placed at sites 1 (left distal) and 4 (right medial), Swede-Vent® implant placed at site 3 (para symphysis), Screw-Vent® implant placed at sites 2 (left medial) and 5 (right distal)
| Study group | Role | What they receive |
|---|---|---|
| Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1 (Configuration 1) | Active comparator | Device placement: B (Brånemark® dental implant) placed at two sites, SW (Swede-Vent® dental implant) placed at two sites, SC (Screw-Vent® dental implant) placed at one site Receives: Device: Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1 (Configuration 1) |
| Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2 (Configuration 2) | Experimental | Device placement: B (Brånemark® dental implant) placed at one site, SW (Swede-Vent® dental implant) placed at two sites, SC (Screw-Vent® dental implant) placed at two sites Receives: Device: Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2 (Configuration 2) |
| Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2 (Configuration 3) | Experimental | Device placement: B (Brånemark® dental implant) placed at two sites, SW (Swede-Vent® dental implant) placed at one site, SC (Screw-Vent® dental implant) placed at two sites Receives: Device: Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2 (Configuration 3) |
What is being measured
The primary outcome is the main question the study is designed to answer.
Comparison of Distance Between First Bone to Implant Contact Point (fBIC) and Microgap (MG), After 25 Years of Function, Between All B, All SW, and All SC Dental Implant Units in All Three Configurations
Distance between first bone-to-implant contact point (fBIC) and microgap (MG) at the crest was measured (mm) at mesial and distal sides of each implant/abutment complex on conventional peri-apical radiographs using a standardized equipment and measurement protocol (Camarda, et al., 2018) after 25 years of function. Values fBIC-MG (Mean ± SE) ("-" for bone loss) were calculated, recorded and compared between all B and all SW, between all B and all SC and between all SW and all SC dental implant units in all three Configurations
Measured: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Secondary outcomes (5)
Comparison of Prosthesis, Abutment, and Implant Mobility or Looseness: Absence (0) or Presence (1) of Mobility or Looseness After 25 Years of Function
Mobility was measured by applying manual pressure on the handles of two instruments, each placed on opposite sides of the prostheses and abutments, and was recorded as 0 (no mobility or looseness) or 1 (mobility or looseness). Values (Mean ± SE) were calculated, recorded and compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)
Measured: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Comparison of Soft Tissue Healing: Height (mm) of Keratinized Tissue After 25 Years of Function
Height of the keratinized tissue was measured (mm) using a ColorVue UNC12 Hu-Friedy probe on the buccal and lingual implant/abutment surfaces. Values (Mean ± SE) were calculated, recorded and compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)
Measured: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Comparison of Soft Tissue Healing: Probing Depth (mm) After 25 Years of Function
Using a ColorVue UNC12 Hu-Friedy probe, probing depth was measured (mm) on the buccal, lingual, mesial and distal implant/abutment surfaces. Values (Mean ± SE) were calculated, recorded and compared between B and SW, between B and SC and between SW and SC for Configuration 1(Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent ®1, Screw-Vent® 2)
Measured: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Comparison of Soft Tissue Healing: Absence (0) or Presence (1) of Plaque and/or Gingival Bleeding After 25 Years of Function
Absence (0) or presence (1) of plaque and/or gingival bleeding on probing was evaluated using the dichotomous/binary plaque index (dPI) (Galgut, P. A., 1999) and bleeding index (dBI), respectively (Galgut, P.A., 1999). Values (Mean ± SE) were compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent ®1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)
Measured: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Comparison of Soft Tissue Healing: Absence (0) or Presence (1) of Purulent Exudate After 25 Years of Function
Absence (0) or presence (1) of purulent exudate on probing was evaluated. Values (Mean ± SE) were recorded, and compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)
Measured: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted5 Mar 2019
- Study start3 Jun 2019
- Primary completion16 Aug 2019
- Study completion31 Dec 2019
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Publications (12)Papers the sponsor has linked to this study.
- Other trials for Jaw, EdentulousStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Triple blind
- Who is masked
- Participant, Care provider, Investigator
- Enrolment
- 22 participants (actual)
Sponsor and investigators
- Lead sponsor
- Université de Montréal
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Aldo Joseph Camarda, Université de Montréal
- Investigators
- Aldo J Camarda, DDS, MSc, Principal investigator, Université de MontréalRobert Durand, DMD, MSc, Principal investigator, Université de MontréalMarwa Benkarim, Principal investigator, Université de MontréalPierre Rompré, MSc, Principal investigator, Université de MontréalGeneviève Guertin, DMD, MSc, Principal investigator, Université de MontréalHugo Ciaburro, DMD, MSc, Study director, Université de Montréal
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03862482
- Sponsor's protocol ID
- CERC-19-015-P
- Status last verified
- May 2021
- First submitted
- 20 Feb 2019
- Last updated
- 14 Jun 2021
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No
Publications
Adell, R. (1987). Long-term treatment results. In: Brånemark, P-I., Zarb, G.A., Albrektsson, T. (Eds.). Tissue-integrated prostheses: osseointegration in clinical dentistry (pp. 175-285). Quintessence Publishing Co. Inc.
Albrektsson T, Branemark PI, Hansson HA, Lindstrom J. Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand. 1981;52(2):155-70. doi: 10.3109/17453678108991776.
PubMed 7246093Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants. 1986 Summer;1(1):11-25. No abstract available.
PubMed 3527955Bhaskaran V, Qualtrough AJ, Rushton VE, Worthington HV, Horner K. A laboratory comparison of three imaging systems for image quality and radiation exposure characteristics. Int Endod J. 2005 Sep;38(9):645-52. doi: 10.1111/j.1365-2591.2005.00998.x.
PubMed 16104978Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986 Feb 8;1(8476):307-10.
PubMed 2868172Branemark PI. Osseointegration and its experimental background. J Prosthet Dent. 1983 Sep;50(3):399-410. doi: 10.1016/s0022-3913(83)80101-2. No abstract available.
PubMed 6352924Brånemark P-I. (1987). Introduction to osseointegration. In Brånemark, P-I., Zarb, G.A., Albrektsson, T. (Eds.). Tissue-integrated prostheses: osseointegration in clinical dentistry (pp. 11-76). Quintessence Publishing Co. Inc.
De Bruyn H, Collaert B, Linden U, Flygare L. A comparative study of the clinical efficacy of Screw Vent implants versus Branemark fixtures, installed in a periodontal clinic. Clin Oral Implants Res. 1992 Mar;3(1):32-41. doi: 10.1034/j.1600-0501.1992.030106.x.
PubMed 1420725Galgut P. A comparison of different indices used in the clinical assessment of plaque and gingival bleeding. Clin Oral Investig. 1999 Jun;3(2):96-9. doi: 10.1007/s007840050085.
PubMed 10803118Niznick, G. A. (1989). Open letters no. 1 and no. 2 to the dental profession, Core-Vent Corporation Newsletter and manufacturer's product description. Encino, California USA.
Camarda AJ, Durand R, Benkarim M, Rompre PH, Guertin G, Ciaburro H. Prospective randomized clinical trial evaluating the effects of two different implant collar designs on peri-implant healing and functional osseointegration after 25 years. Clin Oral Implants Res. 2021 Mar;32(3):285-296. doi: 10.1111/clr.13699. Epub 2021 Jan 25.
PubMed 33314332Camarda AJ, Milot P, Ciaburro H, Rompre PH, Sallaleh I, Do CMA. Long-term randomized clinical trial evaluating the effects of fixture surface acid-etching and machined collar design on bone healing. Quintessence Int. 2018;49(9):733-743. doi: 10.3290/j.qi.a41013.
PubMed 30202836
Study at a glance
From the registry record, last updated by the sponsor on 14 Jun 2021. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Prospective Randomised Clinical Trial Evaluating the Effects of Two Different Implant Collar Designs on Peri-Implant Healing and Functional Osseointegration After 25 Years of Function With Full Arch Mandibular Prostheses
- ClinicalTrials.gov ID
- NCT03862482
- Acronym / sponsor ID
- CERC-19-015-P
- Conditions
- Jaw, Edentulous
- Keywords
- Dental Implants, Microtextured Fixture, Machined Collar
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 22 participants (actual)
- Lead sponsor
- Université de MontréalUniversity, hospital or other
- Study start
- 3 Jun 2019 (actual)
- Primary completion
- 16 Aug 2019 (actual)
- Study completion
- 31 Dec 2019 (actual)
- First posted
- 5 Mar 2019 (actual)
- Results
- Posted 14 Jun 2021
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Brånemark System® dental implant osseointegration was introduced in 1965 as a novel approach to the replacement of missing teeth. Although this implant's machined, screw-shaped surface had excellent, well-documented, short- and long-term clinical success (Adell, R. 1987; Albrektsson, T., et al., 1981; Albrektsson, T., et al., 1986; Brånemark, P-I. , 1983; Brånemark P-I. 1987), newer implant designs were introduced that could enhance fusion of the implant to jaw bones, and better resist functional forces. One such implant, Screw-Vent®, has a fixture macro structure very similar to that of the Brånemark® implant. However, its fixture surface was acid etched (1-3µm) which could enhance osseointegration, and it has a longer, narrower machined internal-hex, friction-fit collar that could better resist functional forces.These characteristics should lead to less bone loss (Niznick, G. A., 1989). However, one clinical study (De Bruyen, et al., 1992) reported greater short-term bone loss with this implant compared to the Brånemark® implant, possibly due to its longer machined collar, and advocated long-term clinical studies. Therefore, this prospective within-subject clinical trial was undertaken in 1993 to first compare the Brånemark® implant with another implant, Swede-Vent®, a copy of the Brånemark® macro structure except for its fixture surface that was identically micro textured as that of Screw-Vent® by the same manufacturer. The effect on bone healing could then be compared between Brånemark®'s machined and Swede-Vent®'s micro textured fixture surfaces in the short- and long-terms. Since Screw-Vent®'s fixture surface was identically micro textured as that of Swede-Vent®, the investigators could then evaluate and compare the effects on bone healing of Screw-Vent®'s longer, narrower, internal-connection machined collar to the identical shorter, wider, external-connection machined collars of the Swede-Vent® and Brånemark® implants. All three two-part, platform-matched, parallel-wall implants were made of commercially pure titanium, had a very similar fixture macro design, were approved by the Food and Drug Administration (USA) and Health and Welfare Canada, and were commercially available in North America. Brånemark® and Screw-Vent® implants are still available, but the Swede-Vent® implant is not.
Detailed description
Therefore, between 1993 and 1996, 58 of 60 eligible participants had been recruited into a prospective, randomized clinical trial. This trial had been peer reviewed, had received ethical approval, and had taken place at the Université de Montréal's Faculty of Dental Medicine and its affiliated hospital dental department. Follow-up documentation occurred at one year, two years, and 15 to 20 years following prostheses attachment (ClinicalTrials Identification Number NCT01641198), and the results were published (Camarda, et al., 2018). The present study reports on data collected at the 25-year (24.6 ± 0.19 years, mean ± SE) follow-up (ClinicalTrials Identification Number NCT03862482), focusing specifically on the evaluation and comparison of the effects on peri-implant healing and functional osseointegration of the two different machined collar designs. That is to say, the identical shorter, wider, external-connection Brånemark® and Swede-Vent® collars versus the longer, narrower, internal-connection Screw-Vent® collar. Twenty-two of the original participants (41.5%, age 71.1 ± 1.2 years, 11 women, 110 implants) were enrolled into this study. All study procedures were performed in accordance with the Helsinki Declaration and its later amendments, and all participants signed informed consent documents prior to inclusion into this study.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Triple blind (participant, care provider, investigator)
- Number of arms
- 3
| Arm | Type | Receives |
|---|---|---|
| Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1 (Configuration 1) | Active comparator | Device: Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1 (Configuration 1)Device placement: B (Brånemark® dental implant) placed at two sites, SW (Swede-Vent® dental implant) placed at two sites, SC (Screw-Vent® dental implant) placed at one site |
| Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2 (Configuration 2) | Experimental | Device: Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2 (Configuration 2)Device placement: B (Brånemark® dental implant) placed at one site, SW (Swede-Vent® dental implant) placed at two sites, SC (Screw-Vent® dental implant) placed at two sites |
| Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2 (Configuration 3) | Experimental | Device: Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2 (Configuration 3)Device placement: B (Brånemark® dental implant) placed at two sites, SW (Swede-Vent® dental implant) placed at one site, SC (Screw-Vent® dental implant) placed at two sites |
Who may qualify
- Ages
- 48 to 82 years
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (3 listed)
- non-smoker
- no temporomandibular joint (TMJ) disorder or facial pain
- having participated in the original study (1993 - 1996) at which time the minimum participants' age was 25 years and the maximum 56 years
Key exclusion criteria (1 listed)
- refusal to sign informed consent documents
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1 (Configuration 1)Brånemark® implant placed at sites 2 (left medial) and 5 (right distal), Swede-Vent® implant placed at sites 1 (left distal) and 4 (right medial), Screw-Vent® implant placed at site 3 (para symphysis) | Device | Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1 (Configuration 1) |
| Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2 (Configuration 2)Brånemark® implant placed at site 3 (para symphysis), Swede-Vent® implant placed at sites 2 (left medial) and 5 (right distal), Screw-Vent® implant placed at sites 1 (left distal) and 4 (right medial) | Device | Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2 (Configuration 2) |
| Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2 (Configuration 3)Brånemark® implant placed at sites 1 (left distal) and 4 (right medial), Swede-Vent® implant placed at site 3 (para symphysis), Screw-Vent® implant placed at sites 2 (left medial) and 5 (right distal) | Device | Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2 (Configuration 3) |
Primary outcome
Comparison of Distance Between First Bone to Implant Contact Point (fBIC) and Microgap (MG), After 25 Years of Function, Between All B, All SW, and All SC Dental Implant Units in All Three Configurations
Time frame: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Distance between first bone-to-implant contact point (fBIC) and microgap (MG) at the crest was measured (mm) at mesial and distal sides of each implant/abutment complex on conventional peri-apical radiographs using a standardized equipment and measurement protocol (Camarda, et al., 2018) after 25 years of function. Values fBIC-MG (Mean ± SE) ("-" for bone loss) were calculated, recorded and compared between all B and all SW, between all B and all SC and between all SW and all SC dental implant units in all three Configurations
5 secondary outcomes
Comparison of Prosthesis, Abutment, and Implant Mobility or Looseness: Absence (0) or Presence (1) of Mobility or Looseness After 25 Years of Function
Time frame: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Comparison of Soft Tissue Healing: Height (mm) of Keratinized Tissue After 25 Years of Function
Time frame: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Comparison of Soft Tissue Healing: Probing Depth (mm) After 25 Years of Function
Time frame: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Comparison of Soft Tissue Healing: Absence (0) or Presence (1) of Plaque and/or Gingival Bleeding After 25 Years of Function
Time frame: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Comparison of Soft Tissue Healing: Absence (0) or Presence (1) of Purulent Exudate After 25 Years of Function
Time frame: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 14 Jun 2021.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- BackgroundAdell, R. (1987). Long-term treatment results. In: Brånemark, P-I., Zarb, G.A., Albrektsson, T. (Eds.). Tissue-integrated prostheses: osseointegration in clinical dentistry (pp. 175-285). Quintessence Publishing Co. Inc.
- Background: PubMed 7246093Albrektsson T, Branemark PI, Hansson HA, Lindstrom J. Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand. 1981;52(2):155-70. doi: 10.3109/17453678108991776.
- Background: PubMed 3527955Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants. 1986 Summer;1(1):11-25. No abstract available.
- Background: PubMed 16104978Bhaskaran V, Qualtrough AJ, Rushton VE, Worthington HV, Horner K. A laboratory comparison of three imaging systems for image quality and radiation exposure characteristics. Int Endod J. 2005 Sep;38(9):645-52. doi: 10.1111/j.1365-2591.2005.00998.x.
- Background: PubMed 2868172Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986 Feb 8;1(8476):307-10.
- Background: PubMed 6352924Branemark PI. Osseointegration and its experimental background. J Prosthet Dent. 1983 Sep;50(3):399-410. doi: 10.1016/s0022-3913(83)80101-2. No abstract available.
- BackgroundBrånemark P-I. (1987). Introduction to osseointegration. In Brånemark, P-I., Zarb, G.A., Albrektsson, T. (Eds.). Tissue-integrated prostheses: osseointegration in clinical dentistry (pp. 11-76). Quintessence Publishing Co. Inc.
- Background: PubMed 1420725De Bruyn H, Collaert B, Linden U, Flygare L. A comparative study of the clinical efficacy of Screw Vent implants versus Branemark fixtures, installed in a periodontal clinic. Clin Oral Implants Res. 1992 Mar;3(1):32-41. doi: 10.1034/j.1600-0501.1992.030106.x.
- Background: PubMed 10803118Galgut P. A comparison of different indices used in the clinical assessment of plaque and gingival bleeding. Clin Oral Investig. 1999 Jun;3(2):96-9. doi: 10.1007/s007840050085.
- BackgroundNiznick, G. A. (1989). Open letters no. 1 and no. 2 to the dental profession, Core-Vent Corporation Newsletter and manufacturer's product description. Encino, California USA.
- Results publication: PubMed 33314332Camarda AJ, Durand R, Benkarim M, Rompre PH, Guertin G, Ciaburro H. Prospective randomized clinical trial evaluating the effects of two different implant collar designs on peri-implant healing and functional osseointegration after 25 years. Clin Oral Implants Res. 2021 Mar;32(3):285-296. doi: 10.1111/clr.13699. Epub 2021 Jan 25.
- Results publication: PubMed 30202836Camarda AJ, Milot P, Ciaburro H, Rompre PH, Sallaleh I, Do CMA. Long-term randomized clinical trial evaluating the effects of fixture surface acid-etching and machined collar design on bone healing. Quintessence Int. 2018;49(9):733-743. doi: 10.3290/j.qi.a41013.
- Individual participant dataSharing planned: No
Related trials for Jaw, Edentulous
Active, not recruiting
L-PRF Block vs Composite Graft for Horizontal Ridge Augmentation
Alveolar Ridge Resorption After Extraction, Alveolar Bone Loss
Not yet recruitingObservational study
Digital and Conventional Clasp-retained Partial Dentures (DIGICLASP)
Partial Edentulism
Recruiting
Dynamic vs. Static Jaw Relations in Implant-Supported Prostheses: Chewing Efficiency
Chewing Efficiency in Completely Edentulous Patients Rehabilitated With Implant-Supported Full-Arch Prostheses
Active, not recruiting
Multicenter Study to Evaluate the Clinical Outcome of PrimeTaper EV Implant in Single Tooth Restorations
Jaw, Edentulous, Partially
Recruiting
Clinical and Radiographic Evaluation of UV-Treated Dental Implants With or Without Melatonin in the Upper Posterior Jaw
Jaw, Edentulous, Partially, Bone Resorption
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Aldo J Camarda, DDS, MSc principal investigator
Université de Montréal
Robert Durand, DMD, MSc principal investigator
Université de Montréal
Marwa Benkarim principal investigator
Université de Montréal
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1 (Configuration 1), Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2 (Configuration 2) and Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2 (Configuration 3) in people with Jaw, Edentulous, run by Université de Montréal at 1 site in Canada.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 14 Jun 2021. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 14 Jun 2021). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Comparison of Distance Between First Bone to Implant Contact Point (fBIC) and Microgap (MG), After 25 Years of Function, Between All B, All SW, and All SC Dental Implant Units in All Three Configurations (time frame: After 25 years (24.6 ± 0.19 years, mean ± SE) of function). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT03862482, which also lists 12 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 14 Jun 2021.