Pulmonary VentilationPhase 3NCT03873233
Flow Controlled Ventilation (FCV) With the Evone Ventilator and Tritube Versus Volume Controlled Ventilation (VCV)
A Phase 3 study testing Aisys Carestation ventilator and normal endotracheal tube and Evone ventilator and Tritube in people with Pulmonary Ventilation, run by University Hospital, Antwerp at 1 site in Belgium.
Trial summary
The Evone® ventilator is a new device capable of lung ventilation through a narrow-bore cannula, the Tritube.Two ventilation modes are possible: high frequency jet ventilation (HFJV) and flow-controlled ventilation (FCV). Read more about this study
- Who is it for?
- Ages 18 to 75 years
- Conditions the study is for
- Pulmonary Ventilation
- What is being tested?
- Aisys Carestation ventilator and normal endotracheal tube and Evone ventilator and Tritube
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 8 participants
- Where
- 1 siteBelgium
- Study dates
- 15 Mar 2019to 5 Aug 2019
- Phase
- Phase 3
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 75 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Scheduled for craniotomy in the supine position due to intracranial neoplasia
- American Society of Anesthesiologists (ASA) Class ≤ 3
- BMI < 30
Who cannot join
- Respiratory disease
- Severe cardiovascular disease
- Non-sinus rhythm
- Poorly controlled hypertension
- Patients with known allergies for rocuronium, propofol or remifentanil
- Emergency procedures
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Flow Controlled Ventilation With the Evone Ventilator and Tritube Versus Volume Controlled Ventilation: A Clinical Pilot Study Describing Oxygenation, Ventilation and Haemodynamic Variables
The Evone® ventilator is a new device capable of lung ventilation through a narrow-bore cannula, the Tritube.Two ventilation modes are possible: high frequency jet ventilation (HFJV) and flow-controlled ventilation (FCV). In this prospective pilot study the efficacy of FCV using the Evone® ventilator and Tritube is investigated when compared with Volume Controlled Ventilation (VCV) via a normal tracheal tube.
Read the detailed description
The Evone® (Ventinova Medical, Eindhoven, The Netherlands) is an automated mechanical ventilator providing pulmonary ventilation by generating a continuous flow into the patient's lungs during inspiration as well as a continuous flow during expiration (flow controlled ventilation, FVC). FCV is a relatively new concept in which ventilation via the Tritube (Ventinova), an ultrathin endotracheal tube, has been made possible due to active suctioning of gas from the lungs during expiration (expiratory ventilation assistance, (EVA)). Adjustable parameters that govern the FCV cycle are: Inspiration Flow, Inspiratory:Expiratory ratio (I:E ratio), maximum tracheal pressure (PMAX) and end expiratory pressure (EEP). Measured parameters are: end-tidal carbon dioxide partial pressure (PE'CO2 ) as measured by capnography, Minute Volume, Peak Tracheal Pressure, End Expiratory Pressure, Respiratory Frequency, I:E ratio and Tidal Volume ( VT). The ventilator screen continuously displays a capnograph with end-tidal CO2, intra-tracheal pressure and inspiratory tidal volume waveforms. In FCV mode, inspiration occurs with the pre-set, constant inspiratory flow until the intratracheal pressure reaches the pre-set value. Assisted expiration then occurs until the pre-set EEP is reached. Expiratory flow is controlled in such a way to achieve a mainly linear reduction in tracheal pressure, whilst ensuring the set I:E ratio. There are no inspiratory or expiratory pauses and EVA does not result in negative tracheal pressures. Thus, minute volume is determined by the set flow rate and the I:E ratio. The set inspiratory peak and end expiratory pressures determine the tidal volumes. Ventilatory frequency is a result of these parameter settings.
The Tritube is a 40 centimeter long narrow diameter cuffed tracheal tube (internal diameter 2.4 millimeter, outer diameter 4,4 millimeter) that can be used with either the manual Ventrain® or automated Evone® ventilator. It consists of three lumens: a ventilatory channel with Murphy eye, a channel for airway pressure measurement and a channel for inflating the high volume, low pressure polyurethane cuff. Preliminary data suggests that Evone® not only provides adequate ventilation via the Tritube, but in comparison with conventional modes of ventilation (volume-controlled, pressure-controlled modes) may result in improved alveolar gas distribution, ventilation/perfusion matching, respiratory mechanics and oxygenation. In this prospective pilot study the efficacy of FCV using the Evone® ventilator and Tritube is investigated when compared with VCV (Aisys Carestation, GE Healthcare, WI, USA) via a normal tracheal tube.
All participants meeting inclusion criteria and having signed Informed Consent will undergo anesthesia and monitoring as per standard of care for the designated surgical procedure (5 lead ECG, non-invasive blood pressure cuff, saturation monitor). Neuromuscular blockade will be monitored by use of the TOF Watch®SX (train-of- four). Depth of anesthesia will be monitored by use of NeuroSENSE ®NS 701 Monitor( NeuroWave Systems incorporated - Cleveland Heights,OH). Following placement of a peripheral intravenous infusion, induction of standard intravenous anesthesia (propofol/remifentanil) and deep neuromuscular relaxation (rocuronium) will be established. Following 3 minutes of preoxygenation (Fractional end-tidal oxygen concentration (FE'O2> 0.9), patients will be intubated with a conventional cuffed tracheal tube cut to 24 centimeter length via oral route and ventilated in standard VCV mode with Fractional Inspired Oxygen concentration (FIO2) at 0.3 percent, Positive End Expiratory Pressure (PEEP + 5cmH2O) and frequency (f) of 12 breaths per minute. Tidal volume will be adjusted to ensure normocapnia. A radial arterial catheter will be placed and attached to a FloTrac sensor and Vigileo monitor ( Edwards Lifesciences, Irvine CA, USA) for continuous measuring of arterial blood pressure and cardiac output. It will facilitate blood gas sampling. Bladder temperature is monitored by means of a urinary catheter and patient is kept warm by means of a warming mattress and air warming blanket. After this preparation phase and prior to start of surgery, each subject will undergo two randomly allocated study periods: one with VCV, the other with FCV. In both cases FIO2 will be 0.3%, EEP at +5 cmH2O and I:E 1:1. Before starting the study protocol all subjects will be pre-oxygenated with 100% Oxygen for three minutes and undergo a recruitment manoeuvre. The recruitment manoevre will be conducted as follows: respiratory rate 12 breaths/minute, tidal volume 6mL/kg, initial PEEP 5cm H2O, with PEEP increasing in 5cm H2O increments to 15cm H2O per 5 breaths and then in decremental steps of 5cm H2O per 5 breaths back to 5 cm H2O PEEP. Peak pressure will be limited to 35 cm H2O.The respiratory circuit will then be disconnected for one minute. This provides sufficient time for placement of the Tritube through the tracheal tube when the subject is randomised to FCV in the first study period. For subjects initially randomised to VCV, VCV will be continued after this sham manoevre. Data collection starts after 15 minutes to allow stabilisation of respiratory and hemodynamic variables. Following data collection, a second 3 minutes pre-oxygenation period with recruitment manoevre and 1 minute apnea will be used before switching to the second ventilation mode.
- Conditions
- Pulmonary Ventilation
- Being tested
- Aisys Carestation ventilator and normal endotracheal tube, Evone ventilator and Tritube
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Aisys Carestation ventilator and normal endotracheal tubeDevice
Fraction of Inspired Oxygen (FIO2) 0.3 End Expiratory Pressure (EEP) at +5 cm H2O Ratio of duration of inspiration to the duration of expiration (I:E ratio) 1:1 Tidal Volume: 6 mL/kg Zero inspiratory pause Respiratory frequency will be adapted to produce an End-Tidal CO2 35-40 mmHg
Evone ventilator and TritubeDevice
Fraction of Inspired Oxygen (FIO2) 0.3 Ratio of duration of inspiration to the duration of expiration (I:E ratio) 1:1 End Expiratory Pressure (EEP) at +5 cm H2O Flow: start with 10 L/min and adjusted along with the peak inspiratory pressure to produce a tidal volume of 6 mL/kg and End-Tidal CO2 35-40 mmHg
| Study group | Role | What they receive |
|---|---|---|
| Volume Controlled Ventilation | Active comparator | Volume Controlled Ventilation with Aisys Carestation ventilator and normal endotracheal tube' Receives: Device: Aisys Carestation ventilator and normal endotracheal tube |
| Flow Controlled Ventilation | Active comparator | Flow Controlled Ventilation with Evone ventilator and Tritube Receives: Device: Evone ventilator and Tritube |
What is being measured
The primary outcome is the main question the study is designed to answer.
Observation of systemic arterial oxygen partial pressure (PaO2) values in both ventilation modes during normocapnia (PE'CO2 35-40 mm Hg) .
Following stable ventilation for 15 minutes with respect to randomised ventilation mode, arterial blood gas will be taken.
Measured: Following stable ventilation for 15 minutes in randomised ventilation modus, data collection starts and ends before start of surgery.
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted13 Mar 2019
- Study start15 Mar 2019
- Primary completion5 Aug 2019
- Study completion5 Aug 2019
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Pulmonary VentilationStudies of the same condition, open and under way.
- More trials run by University Hospital, AntwerpThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase 3
- Primary purpose
- Other
- Allocation
- Randomised
- Intervention model
- Crossover
- Model description
- Patients undergoing craniotomy will be ventilated during surgery using both conventional VCV and FVC modes. Standard baseline VCV is used for induction and stabilization of anesthesia. The order of ventilation mode is randomly assigned.
- Masking
- None (open label)
- Enrolment
- 8 participants (actual)
Sponsor and investigators
- Lead sponsor
- University Hospital, Antwerp
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Joke De Wachter, University Hospital, Antwerp
- Investigators
- Vera Saldien, MD, Principal investigator, University Hospital, Antwerp
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03873233
- Sponsor's protocol ID
- 18/45/512
- Status last verified
- Sep 2019
- First submitted
- 7 Feb 2019
- Last updated
- 6 Sep 2019
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
Study at a glance
From the registry record, last updated by the sponsor on 6 Sep 2019. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Flow Controlled Ventilation With the Evone Ventilator and Tritube Versus Volume Controlled Ventilation: A Clinical Pilot Study Describing Oxygenation, Ventilation and Haemodynamic Variables
- ClinicalTrials.gov ID
- NCT03873233
- Acronym / sponsor ID
- 18/45/512
- Conditions
- Pulmonary Ventilation
- Phase
- Phase 3
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 8 participants (actual)
- Lead sponsor
- University Hospital, AntwerpUniversity, hospital or other
- Study start
- 15 Mar 2019 (actual)
- Primary completion
- 5 Aug 2019 (actual)
- Study completion
- 5 Aug 2019 (actual)
- First posted
- 13 Mar 2019 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The Evone® ventilator is a new device capable of lung ventilation through a narrow-bore cannula, the Tritube.Two ventilation modes are possible: high frequency jet ventilation (HFJV) and flow-controlled ventilation (FCV). In this prospective pilot study the efficacy of FCV using the Evone® ventilator and Tritube is investigated when compared with Volume Controlled Ventilation (VCV) via a normal tracheal tube.
Detailed description
The Evone® (Ventinova Medical, Eindhoven, The Netherlands) is an automated mechanical ventilator providing pulmonary ventilation by generating a continuous flow into the patient's lungs during inspiration as well as a continuous flow during expiration (flow controlled ventilation, FVC). FCV is a relatively new concept in which ventilation via the Tritube (Ventinova), an ultrathin endotracheal tube, has been made possible due to active suctioning of gas from the lungs during expiration (expiratory ventilation assistance, (EVA)). Adjustable parameters that govern the FCV cycle are: Inspiration Flow, Inspiratory:Expiratory ratio (I:E ratio), maximum tracheal pressure (PMAX) and end expiratory pressure (EEP). Measured parameters are: end-tidal carbon dioxide partial pressure (PE'CO2 ) as measured by capnography, Minute Volume, Peak Tracheal Pressure, End Expiratory Pressure, Respiratory Frequency, I:E ratio and Tidal Volume ( VT). The ventilator screen continuously displays a capnograph with end-tidal CO2, intra-tracheal pressure and inspiratory tidal volume waveforms. In FCV mode, inspiration occurs with the pre-set, constant inspiratory flow until the intratracheal pressure reaches the pre-set value. Assisted expiration then occurs until the pre-set EEP is reached. Expiratory flow is controlled in such a way to achieve a mainly linear reduction in tracheal pressure, whilst ensuring the set I:E ratio. There are no inspiratory or expiratory pauses and EVA does not result in negative tracheal pressures. Thus, minute volume is determined by the set flow rate and the I:E ratio. The set inspiratory peak and end expiratory pressures determine the tidal volumes. Ventilatory frequency is a result of these parameter settings.
The Tritube is a 40 centimeter long narrow diameter cuffed tracheal tube (internal diameter 2.4 millimeter, outer diameter 4,4 millimeter) that can be used with either the manual Ventrain® or automated Evone® ventilator. It consists of three lumens: a ventilatory channel with Murphy eye, a channel for airway pressure measurement and a channel for inflating the high volume, low pressure polyurethane cuff. Preliminary data suggests that Evone® not only provides adequate ventilation via the Tritube, but in comparison with conventional modes of ventilation (volume-controlled, pressure-controlled modes) may result in improved alveolar gas distribution, ventilation/perfusion matching, respiratory mechanics and oxygenation. In this prospective pilot study the efficacy of FCV using the Evone® ventilator and Tritube is investigated when compared with VCV (Aisys Carestation, GE Healthcare, WI, USA) via a normal tracheal tube.
All participants meeting inclusion criteria and having signed Informed Consent will undergo anesthesia and monitoring as per standard of care for the designated surgical procedure (5 lead ECG, non-invasive blood pressure cuff, saturation monitor). Neuromuscular blockade will be monitored by use of the TOF Watch®SX (train-of- four). Depth of anesthesia will be monitored by use of NeuroSENSE ®NS 701 Monitor( NeuroWave Systems incorporated - Cleveland Heights,OH). Following placement of a peripheral intravenous infusion, induction of standard intravenous anesthesia (propofol/remifentanil) and deep neuromuscular relaxation (rocuronium) will be established. Following 3 minutes of preoxygenation (Fractional end-tidal oxygen concentration (FE'O2> 0.9), patients will be intubated with a conventional cuffed tracheal tube cut to 24 centimeter length via oral route and ventilated in standard VCV mode with Fractional Inspired Oxygen concentration (FIO2) at 0.3 percent, Positive End Expiratory Pressure (PEEP + 5cmH2O) and frequency (f) of 12 breaths per minute. Tidal volume will be adjusted to ensure normocapnia. A radial arterial catheter will be placed and attached to a FloTrac sensor and Vigileo monitor ( Edwards Lifesciences, Irvine CA, USA) for continuous measuring of arterial blood pressure and cardiac output. It will facilitate blood gas sampling. Bladder temperature is monitored by means of a urinary catheter and patient is kept warm by means of a warming mattress and air warming blanket. After this preparation phase and prior to start of surgery, each subject will undergo two randomly allocated study periods: one with VCV, the other with FCV. In both cases FIO2 will be 0.3%, EEP at +5 cmH2O and I:E 1:1. Before starting the study protocol all subjects will be pre-oxygenated with 100% Oxygen for three minutes and undergo a recruitment manoeuvre. The recruitment manoevre will be conducted as follows: respiratory rate 12 breaths/minute, tidal volume 6mL/kg, initial PEEP 5cm H2O, with PEEP increasing in 5cm H2O increments to 15cm H2O per 5 breaths and then in decremental steps of 5cm H2O per 5 breaths back to 5 cm H2O PEEP. Peak pressure will be limited to 35 cm H2O.The respiratory circuit will then be disconnected for one minute. This provides sufficient time for placement of the Tritube through the tracheal tube when the subject is randomised to FCV in the first study period. For subjects initially randomised to VCV, VCV will be continued after this sham manoevre. Data collection starts after 15 minutes to allow stabilisation of respiratory and hemodynamic variables. Following data collection, a second 3 minutes pre-oxygenation period with recruitment manoevre and 1 minute apnea will be used before switching to the second ventilation mode.
Study design
- Primary purpose
- Other
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- None (open label)
- Number of arms
- 2
- Model description
- Patients undergoing craniotomy will be ventilated during surgery using both conventional VCV and FVC modes. Standard baseline VCV is used for induction and stabilization of anesthesia. The order of ventilation mode is randomly assigned.
| Arm | Type | Receives |
|---|---|---|
| Volume Controlled Ventilation | Active comparator | Device: Aisys Carestation ventilator and normal endotracheal tubeVolume Controlled Ventilation with Aisys Carestation ventilator and normal endotracheal tube' |
| Flow Controlled Ventilation | Active comparator | Device: Evone ventilator and TritubeFlow Controlled Ventilation with Evone ventilator and Tritube |
Who may qualify
- Ages
- 18 to 75 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (3 listed)
- Scheduled for craniotomy in the supine position due to intracranial neoplasia
- American Society of Anesthesiologists (ASA) Class ≤ 3
- BMI < 30
Key exclusion criteria (6 listed)
- Respiratory disease
- Severe cardiovascular disease
- Non-sinus rhythm
- Poorly controlled hypertension
- Patients with known allergies for rocuronium, propofol or remifentanil
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Aisys Carestation ventilator and normal endotracheal tubeFraction of Inspired Oxygen (FIO2) 0.3 End Expiratory Pressure (EEP) at +5 cm H2O Ratio of duration of inspiration to the duration of expiration (I:E ratio) 1:1 Tidal Volume: 6 mL/kg Zero inspiratory pause Respiratory frequency will be adapted to produce an End-Tidal CO2 35-40 mmHg | Device | Volume Controlled Ventilation |
| Evone ventilator and TritubeFraction of Inspired Oxygen (FIO2) 0.3 Ratio of duration of inspiration to the duration of expiration (I:E ratio) 1:1 End Expiratory Pressure (EEP) at +5 cm H2O Flow: start with 10 L/min and adjusted along with the peak inspiratory pressure to produce a tidal volume of 6 mL/kg and End-Tidal CO2 35-40 mmHg | Device | Flow Controlled Ventilation |
Primary outcome
Observation of systemic arterial oxygen partial pressure (PaO2) values in both ventilation modes during normocapnia (PE'CO2 35-40 mm Hg) .
Time frame: Following stable ventilation for 15 minutes in randomised ventilation modus, data collection starts and ends before start of surgery.
Following stable ventilation for 15 minutes with respect to randomised ventilation mode, arterial blood gas will be taken.
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 6 Sep 2019.
Related trials for Pulmonary Ventilation
Enrolling by invitation
Personalized Ventilator Settings for Patients on ECMO
Acute Respiratory Distress Syndrome (ARDS), Extracorporeal Membrane Oxygenation
Active, not recruiting
CT for Personalized Mechanical Ventilation
Ventilator-Induced Lung Injury, Sepsis Syndrome
Not yet recruiting
Effect of Box Breathing Exercise on Anxiety, Pain, and Pulmonary Function Tests in Patients Undergoing Colonoscopy
Colonoscopy
Not yet recruitingObservational study
Development and Multicenter Validation of an Explainable System for Neonatal ARDS-Compatible Phenotyping
Acute Respiratory Distress Syndrome
Not yet recruiting
Regional Lung Ventilation During Prone Position in in Intubated Children
Pediatric Acute Respiratory Failure
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Vera Saldien, MD principal investigator
University Hospital, Antwerp
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A Phase 3 study testing Aisys Carestation ventilator and normal endotracheal tube and Evone ventilator and Tritube in people with Pulmonary Ventilation, run by University Hospital, Antwerp at 1 site in Belgium.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 6 Sep 2019. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Belgium. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
What does this phase mean?
Phase 3 studies compare the treatment with the current standard treatment or a placebo in a large group, to confirm how well it works and watch for side effects.
Not every study follows the same path, and some studies (observational studies, device studies) have no phase.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Observation of systemic arterial oxygen partial pressure (PaO2) values in both ventilation modes during normocapnia (PE'CO2 35-40 mm Hg) . (time frame: Following stable ventilation for 15 minutes in randomised ventilation modus, data collection starts and ends before start of surgery.). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Sep 2019.