AzTrials
AzTrials

Tooth MovementRCTNCT03876184

Alignment Efficiency and Coating Durability of Aesthetic Archwires

A study testing Aesthetic archwires in people with Tooth Movement, run by Universiti Sains Malaysia at 3 sites in Malaysia.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This study investigates the efficiency of orthodontic aesthetic archwires which are coated with tooth-colored materials and the durability of the coatings after being used. Theoretically, the coatings provide excellent aesthetics throughout treatment and faster tooth alignment. Read more about this study

Who is it for?
Ages 11 years and olderHealthy volunteers can take part
Conditions the study is for
Tooth Movement
What is being tested?
Aesthetic archwires
Could I receive a placebo?
No, everyone receives an active treatment
How many people
132 participants
Where
3 sitesMalaysia
Study dates
2 Oct 2017to 31 Jan 2020
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 11 years and older
  • All sexes
  • Healthy volunteers accepted
  • Child, Adult, Older adult

Who may be able to join

  • Patient aged 11 years old and above in permanent dentition with all teeth from upper and lower 6 - 6 are present, tooth apices are closed
  • Patients who require complete bond-up with upper and lower pre-adjusted edgewise bracket system, MBT prescription with bracket slot size 0.022"
  • Able to give consent* *Assent form is required for children below 18 years of age

Who cannot join

  • Patients with cleft lip and palate and other craniofacial deformities and syndromes
  • Patients with medical problems / medications that can influence rate of tooth movement
  • Teeth blocked out of the arch / ectopic teeth not allowing bracket placement and ligation at bond-up
  • Hypodontia with more than one tooth missing in any quadrant
  • Have had orthodontic treatment before

Trial locations and contacts

3 sites in 1 country.

Malaysia3 sites
  • Advanced Medical & Dental Institute

    Kepala Batas, Pulau Pinang, 13200

  • School of Dental Sciences

    Kubang Kerian, Kelantan, 16150

  • Desa Murni Dental Clinic

    Permatang Pauh, Pulau Pinang, 13500

Other trials in Malaysia

About this study

Official title: Randomised Controlled Trial of the Alignment Efficiency and Coating Durability of Aesthetic Archwires

This study investigates the efficiency of orthodontic aesthetic archwires which are coated with tooth-colored materials and the durability of the coatings after being used. Theoretically, the coatings provide excellent aesthetics throughout treatment and faster tooth alignment. However, from our clinical experience, these claims are the opposite. Cracks and ruptures as well as archwire fractures have been noted. Therefore, it is presumed that the aesthetic archwires may not be any different from the conventional uncoated archwires.

Read the detailed description

The development of superelastics nickel titanium (SE NiTi) has overcome problems with previous aligning archwires. This archwire is deemed to be the gold standard aligning archwire for Straight Wire® system due to its shape memory effect, high elasticity and low permanent deformation which delivers continuous force for orthodontic tooth alignment. The only drawbacks of this wire type are it is expensive, have high frictional resistance (Kapila et al., 1990) and is associated with hypersensitivity reaction in nickel allergic patients (Bass et al., 1993).

Development of teflon or polytetrafluoroethylene (PTFE) which is anti-adherent and possesses aesthetic property had been used as orthodontic bracket, archwire and ligature coating. This polymer consists of synthetic fluorine-containing resin or epoxy resin composed mainly of polytetrafluoroethylyene to simulate tooth colour. The polymeric chain with good mechanical stability had been shown to reduce the frictional resistance between bracket-archwire interface and when used as archwire ligature (Farronato et al., 2012, De Franco et al., 1995). PTFE-coated brackets were reported to minimise the formation of biofilm during treatment which can reduce the risk of enamel decalcification (Demling et al., 2010). Furthermore, the coated aesthetic archwires have potential to obviate any allergic reaction during orthodontic treatment in patients with known hypersensitivity to nickel alloy.

Manufacturers have claimed that the aesthetic archwires available in the market have good color stability (remains unchanged for 6 to 8-week duration), good coating durability and low friction, allowing faster tooth movement. However, to our experience, these claims are the opposite.

As these aesthetic archwires are much more expensive than the conventional superelastic nickel titanium, it is therefore important to establish a clinical data to allow clinicians and patients to make a justifiable choice on treatment and develop further research in this area.

Conditions
Tooth Movement
Being tested
Aesthetic archwires, Control group
Keywords
tooth alignment, coating loss, color change, patient perception, aesthetic archwire

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Aesthetic archwiresOther

    During bond-up, randomly allocated envelope will be opened and archwires will be ligated with elastomeric ligatures.After 4 weeks,the same archwires will be retied.Any fractured archwire will be recorded and discarded.The fractured wire will be replaced with conventional archwire and treatment continues.On the 2nd follow-up (at 8th week), the tested wires are collected, disinfected, dried and placed back in the allocated envelope.Upper and lower impressions will be taken.Questionnaires will be answered by participants.The trial ends and treatment continues as planned.Fractured archwire will be recorded and discarded.

  • Control groupOther

    During bond-up, randomly allocated envelope will be opened and archwires will be ligated with elastomeric ligatures.After 4 weeks,the same archwires will be retied.Any fractured archwire will be recorded and discarded.The fractured wire will be replaced with conventional archwire and treatment continues.On the 2nd follow-up (at 8th week), the tested wires are collected, disinfected, dried and placed back in the allocated envelope.Upper and lower impressions will be taken.This group will not answer the questionnaire.The trial ends and treatment continues as planned.Fractured archwire will be recorded and discarded.

Study groups in NCT03876184
Study groupRoleWhat they receive
RMO FLi® Tooth-coloured superelastic Nickel TitaniumExperimentalThis group has been allocated with upper and lower round 0.014" RMO FLi® Tooth-coloured superelastic Nickel Titanium aesthetic archwires for a duration of 8 weeks.
Receives: Other: Aesthetic archwires
G&H G4 Tooth-coloured superelastic Nickel TitaniumExperimentalThis group has been allocated with upper and lower round 0.014" G\&H G4 Tooth-coloured superelastic Nickel Titanium aesthetic archwires for a duration of 8 weeks.
Receives: Other: Aesthetic archwires
Orthocare Euroform® Cosmetic Tooth-coloured superelastic Nickel TitaniumExperimentalThis group has been allocated with upper and lower round 0.014" Orthocare Euroform® Cosmetic Tooth-coloured superelastic Nickel Titanium aesthetic archwires for a duration of 8 weeks.
Receives: Other: Aesthetic archwires
Conventional superelastic Nickel TitaniumActive comparatorThis group has been allocated with conventional upper and lower round 0.014" superelastic Nickel Titanium archwires for a duration of 8 weeks.
Receives: Other: Control group

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Alignment efficiency

    The tooth irregularity between pre- and post-experiment dental casts are measured in millimetres. The difference between the two measurement will be calculated in percentage.

    Measured: 8 weeks

Secondary outcomes (3)
  1. Coating loss

    The amount of coating loss between the used and unused archwires will be measured in percentage.

    Measured: 8 weeks

  2. Color change

    The difference in colour (colour change) between used and unused archwires will be measured in CIE L* a* b* colour space units.

    Measured: 8 weeks

  3. Participant perception towards aesthetic archwires

    Patient perception will be assessed using oral aesthetic subjective impact scale (OASIS) questionnaires after the use of aesthetic archwires (at week 8). The cumulative score will be used to determine the perception (14 and below = positive perception; 15 and above = negative perception).

    Measured: 8 weeks

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted15 Mar 2019
  2. Study start2 Oct 2017
  3. Primary completion31 Jan 2020
  4. Study completion31 Jan 2020

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Quadruple blind
Who is masked
Participant, Care provider, Investigator, Outcomes assessor
Enrolment
132 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03876184
Sponsor's protocol ID
USM/JEPeM/17010022
Acronym
RCT
Status last verified
May 2021
First submitted
10 Mar 2019
Last updated
11 May 2021
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Yes: All IPD that underlie results in publication

Publications

  • Bass JK, Fine H, Cisneros GJ. Nickel hypersensitivity in the orthodontic patient. Am J Orthod Dentofacial Orthop. 1993 Mar;103(3):280-5. doi: 10.1016/0889-5406(93)70009-D.

    PubMed 8456786
  • Kapila S, Angolkar PV, Duncanson MG Jr, Nanda RS. Evaluation of friction between edgewise stainless steel brackets and orthodontic wires of four alloys. Am J Orthod Dentofacial Orthop. 1990 Aug;98(2):117-26. doi: 10.1016/0889-5406(90)70005-W.

    PubMed 2378317
  • Farronato G, Maijer R, Caria MP, Esposito L, Alberzoni D, Cacciatore G. The effect of Teflon coating on the resistance to sliding of orthodontic archwires. Eur J Orthod. 2012 Aug;34(4):410-7. doi: 10.1093/ejo/cjr011. Epub 2011 Apr 8.

    PubMed 21478301
  • Demling A, Elter C, Heidenblut T, Bach FW, Hahn A, Schwestka-Polly R, Stiesch M, Heuer W. Reduction of biofilm on orthodontic brackets with the use of a polytetrafluoroethylene coating. Eur J Orthod. 2010 Aug;32(4):414-8. doi: 10.1093/ejo/cjp142. Epub 2010 Feb 5.

    PubMed 20139131
  • De Franco DJ, Spiller RE Jr, von Fraunhofer JA. Frictional resistances using Teflon-coated ligatures with various bracket-archwire combinations. Angle Orthod. 1995;65(1):63-72; discussion 73-4. doi: 10.1043/0003-3219(1995)0652.0.CO;2.

    PubMed 7726464

Questions about this trial

What is this clinical trial studying?

A study testing Aesthetic archwires in people with Tooth Movement, run by Universiti Sains Malaysia at 3 sites in Malaysia.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 11 May 2021. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 3 sites in Malaysia. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Alignment efficiency (time frame: 8 weeks). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03876184, which also lists 5 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 11 May 2021.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in