AzTrials
AzTrials

MRINCT03915015

VAPORHCS/OHSU J: MRI and Devices

A study testing MRI in people with MRI, run by Oregon Health and Science University at 2 sites in United States.

Recruiting

Looking for participants now. Contact the study team or a site below to ask about taking part.

Sites and contacts
Official record
Search all trials

Trial summary

This is a database study of clinically indicated MRIs on patients with permanent pacemakers and implantable cardioverter defibrillators. Read more about this study

Who is it for?
Ages 9 to 99 years
Conditions the study is for
MRI
What is being tested?
MRI
Could I receive a placebo?
No, everyone receives an active treatment
How many people
10,000 participants
Where
2 sitesUnited States
Study dates
19 Jul 2012to 31 Dec 2030
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 9 to 99 years
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Who may be able to join

  • Patients with an absolute clinical need for MR imaging and PPM (year 1996 model or later) or ICD's (year 2000 or later)

Who cannot join

  • Patients with pacemaker models before 1996 and ICD models before year 2000.
  • Pacemaker dependent patients with ICD.
  • Patients who weighing less than 80 lbs.
  • Patients who complete the MRI standard screening form and are deemed inappropriate for MRI for any reason
  • Pregnant patients will be excluded in their first trimester and will not get gadolinium at any time during their pregnancy
  • Patient with abandoned/capped leads or leads implanted <4 weeks unless the procedure is deemed critical by the referring physician and approved by the PI

Trial locations and contacts

2 sites in 1 country. Contact the study team or a site near you to ask about taking part.

Charles Henrikson, MD contact

503-494-7400

henrikso@ohsu.edu

United States2 sites, 2 recruiting
  • Oregon Health and Scince University

    Portland, Oregon, 97239

    Charles Henrikson, MD

    Recruiting
  • Portland Veterans Administration Medical Center

    Portland, Oregon, 97239

    Peter Jessel, MD

    Recruiting

Other trials in United States

About this study

Official title: VAPORHCS/OHSU J: Safety of Clinically Indicated Magnetic Resonance Imaging in Patients With Permanent Pacemakers (PPM) and Implanted Cardioverter Defibrillators (ICDs)

This is a database study of clinically indicated MRIs on patients with permanent pacemakers and implantable cardioverter defibrillators.

Read the detailed description
  1. Abstract Ferromagnetic Implants such as PPM's and ICD's are traditionally accepted as contraindications to MRI due to safety concerns. The hypothesis is that these procedures can be safely performed when appropriate safety precautions and vetting practices are implemented. This is a cohort study. 1000 patients with a clinical need for MRI will be included in the study at OHSU. The type of device and leads will be ascertained and a safety protocol will be strictly adhered to.
  2. Background It has been estimated that 50-75% of patients with implanted devices (pacemakers and ICDs) will develop an indication for magnetic resonance imaging (MRI) examination. Thus, there are approximately 200,000 patients annually denied MRI scans because of the presence of PPMs and ICDs in the United States. The current standard of care is not to perform these scans, and instead to utilize other (inferior) imaging, and make clinical decisions without the benefit of MRI imaging. This is the current standard of care of OHSU, where only pacemaker patients who are not pacemaker dependent can undergo MRI scans, per radiology policy. However, this leads to gaps in care for some patients who would clearly benefit from an MRI scan. In some centers, it has been shown that when proper precautions are taken, MRIs can be safely performed on patients with PPMs and ICDs. The published experience from Johns Hopkins reports over 500 scans performed without any adverse outcomes.(1) There are also several smaller studies documenting the safe experience with MRI scanning in device patients (reviewed in (1), table 4) The main concerns which have led to restrictions on MRIs in patients with cardiac rhythm devices are the following:(2)
  3. Force and torque-ferromagnetic devices in a magnetic field are subject to static and gradient magnetic field induced force and torque. However, the maximum force that a modern PPM or ICD generator would be subject to is 100g, far under what would be needed to dislodge a device.
  4. Current induction-the gradient magnetic fields in the MRI scanner could induce current in conductors in the field. However, the maximum observed current in vitro has been less than 0.5mA, far less than what is required to capture myocardium.
  5. Heating-Leads and other metallic devices can act as antennae, and may heat in the magnetic field, however, no heating greater than 0.5deg C were observed in vitro.
  6. Inappropriate pacing/shock/inhibition of pacing-Pacemakers and ICDs have the possibility of receiving electromagnetic interference from the MRI and having this lead to inappropriate pacing, inhibition of pacing, ICD shocks, reprogramming, or loss of function. While all of the concerns are real and have been reported in earlier generation devices, with proper patient selection and monitoring during the scan, MRIs can be performed safely on most device patients. Johns Hopkins has an experience of over 500 scans without any adverse events.(1) The proposed protocol here follows exactly the Hopkins protocol, and, indeed, the OHSU data will be combined with the Hopkins data for future publications. To review the most recent Johns Hopkins publication:(1) 555 MRI studies in 438 device (PPM and ICD) patients were reported. All MRI scans were clinically indicated, and a device clinician, familiar with device interrogation and programming, was physically present for the entire duration of the scan. All patients were continuously monitored via telemetry and pulse oximetry during the MRI. For pacemaker patients, if they are pacemaker dependent they were reprogrammed to a non-sensing mode for the scan. If they were not pacemaker dependent, they were left in their usual mode. For ICD patients, if they were not pacemaker dependent, they were left in their usual mode. However, pacemaker dependent ICD patients were not scanned, as ICDs generally do not have a non-sensing pacing mode. Therapy for tachycardia was disabled in all ICDs for the scan. There were three clinical events during scans, all were "power on resets", which means that the device resets to "out of the box" original factory settings. One of these patients had an ICD, felt tugging in his chest during the scan, and the scan was not completed. The other two power on resets were in PPM patients, in whom the scan was completed. Neither were pacemaker dependent, and neither noticed anything abnormal during the scan. All three patients had normally functioning devices following the scan, and at followup. In the overall patient population in the Hopkins study, no single patient had a malfunction of a device immediately following the scan. There was a slight change in the electrical parameters of the leads, on average, but this did not result in the need for any intervention on any patient.
  7. Objectives The primary objective of this study is to develop a protocol, consistent with DHHS/CMS guidelines and requirements to further document safety in clinically indicated MR imaging in patients with implanted cardioverter defibrillators (ICD's) and pacemakers.
  8. Study Procedures MRI's will be conducted on patients who require a clinically indicated MRI only. All studies will be done in the 1.5 Tesla MRI unit. ECG monitoring pads will be placed on the patients for the duration of the study. An external defibrillator and ACLS drugs will be on hand. Heart rate, blood pressure, O2 saturation will also be monitored non-invasively throughout the study. All devices will undergo a complete interrogation prior to imaging. Parameters such as atrial and ventricular pacing thresholds, R and P wave amplitudes, lead impedance, and battery status will be measured and recorded. PPMs will be programmed to an asynchronous mode if dependent and to an inhibited mode in patients without pacemaker dependence. The pacemaker function of ICD's in pacemaker independent patients will be programmed to ventricular inhibited (VVI) mode at 50 bpm. Pacemaker dependent patients with ICDs will be excluded. In addition, there is a theoretical concern that patients who have capped or abandoned leads in their chest may be at risk for heating. While there is little or no objective data to support this concern, given this theoretical concern, patients in this category will only be admitted to the study if the referring physician deems the MRI critical and after the PI has carefully considered the risk/benefit ration for each patient who falls in to this category. Similarly, there historically has also been a concern that newly implanted leads (<4 weeks) are at risk for lead to dislodgement d/t possible torque from the MRI environment. This too is only a theoretical concern and there is little or no scientific evidence to support this claim. Nevertheless, patients with newly implanted pacemaker/ICD leads will be considered by the PI for protocol inclusion only if the referring physician deems the MRI to be critical and after considering the risk/benefit to each individual patient. After the appropriate MRI protocol for each MRI patient's unique condition has been completed, the device will be re-programmed to its original settings and completely interrogated to detect any changes in device performance. The duration of the study extends to the post procedure interrogation at 1-6 weeks post MRI. IF the PPM or ICD reveals any malfunction post imaging (not seen yet), the patient will be followed by the electrophysiology service and appropriate follow-up management will be arranged.
  9. Study Statistics
  10. Primary outcome variable. Patient safety and device malfunction during or after MRI
  11. Secondary outcome variables. None
  12. Statistical plan including sample size justification and interim data analysis. We hope to enroll 1000 patients over 4 years to further evaluate safety.
  13. Early stopping rules. N/A
  14. Risks
  15. Medical risks, listing all procedures, their major and minor risks and expected frequency. There are no studies showing any health hazards associated with magnetic field exposure. PPM and ICD implants subjected to the strong electromagnetic field of MR imaging are thought to be susceptible to movement and torque. Other traditional concerns include malfunction due to demagnetization or magnetic activation leading to inappropriate pacing and shocks and artificial sensing of electromagnetic interference from MRI leading to inappropriate inhibition and/or activation of antitachycardia therapy, device malfunction and induced arrhythmias, as detailed in the background section above. Heating of the device and surrounding tissues leading to fibrosis and increased capture thresholds have also been a theoretical concern. However, recent work has revealed the safety of PPM's and certain ICD's in the MR environment given appropriate precautions(1, 3, 4).
  16. Steps taken to minimize the risks. Appropriate measures discussed in the protocol section will be taken to minimize risks associated with device exposure to MRI. Consistent with standard MRI policy, patients in the first trimester of pregnancy and patients with history of allergic reactions to gadolinium will undergo imaging without any contrast media.
  17. Plan for reporting unanticipated problems or study deviations. Patient data will be monitored on a per patient basis. Pre-vs. post MRI device testing data will be compared and any significant differences immediately reported to the IRB.
  18. Benefits a. Description of the probable benefits for the participant and for society. The patient will benefit from a standardized protocol to minimize the risk of an MR scan deemed necessary for his/her care which would otherwise be denied or performed without any organized framework. Society will benefit because of the increasing number of implanted devices and expanding use of MRI.

8 Costs

  1. Detail costs of study procedure(s) or drug (s) or substance(s) to participants and identify who will pay for them.

The patient and his/her insurance will be responsible for the cost of the clinically indicated MRI.

Conditions
MRI
Being tested
MRI

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • MRIDiagnostic test

    MRI

Study groups in NCT03915015
Study groupRoleWhat they receive
the studyOtherPatients with a PPM or ICD getting a clinically indicated MRI
Receives: Diagnostic Test: MRI

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. MRI Safety during MRI scan in patients with PPMs/ICDs.

    Percent of patients successfully completing MRI scan without complication per interrogation of their device and clinical assessment.

    Measured: During MRI scan.

  2. MRI Safety following MRI scan in patients with PPMs/ICDs.

    Percent of patients successfully following up after MRI scan without complication per interrogation of their device and clinical assessment.

    Measured: 1-6 week follow up in device clinic

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted16 Apr 2019
  2. Study start19 Jul 2012
  3. Primary completion31 Dec 2030 (estimated)
  4. Study completion31 Dec 2030 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
10,000 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03915015
Sponsor's protocol ID
8423
Status last verified
Apr 2024
First submitted
13 Mar 2019
Last updated
15 Apr 2024
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Publications

  • Yadava M, Nugent M, Krebsbach A, Minnier J, Jessel P, Henrikson CA. Magnetic resonance imaging in patients with cardiac implantable electronic devices: a single-center prospective study. J Interv Card Electrophysiol. 2017 Oct;50(1):95-104. doi: 10.1007/s10840-017-0262-6. Epub 2017 Jul 22.

    PubMed 28733766
  • Nazarian S, Hansford R, Roguin A, Goldsher D, Zviman MM, Lardo AC, Caffo BS, Frick KD, Kraut MA, Kamel IR, Calkins H, Berger RD, Bluemke DA, Halperin HR. A prospective evaluation of a protocol for magnetic resonance imaging of patients with implanted cardiac devices. Ann Intern Med. 2011 Oct 4;155(7):415-24. doi: 10.7326/0003-4819-155-7-201110040-00004.

    PubMed 21969340

Questions about this trial

What is this clinical trial studying?

A study testing MRI in people with MRI, run by Oregon Health and Science University at 2 sites in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: looking for participants now, as of the sponsor's last update on 15 Apr 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 2 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Charles Henrikson, MD (503-494-7400, henrikso@ohsu.edu), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

MRI Safety during MRI scan in patients with PPMs/ICDs. (time frame: During MRI scan.). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03915015, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 Apr 2024.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in