AzTrials
AzTrials

Diabetes MellitusGluPopNCT03935919

Perioperative Continuous Glucose Monitoring in Patients Undergoing an Abdominal Surgery

An observational study of Diabetes Mellitus and Prediabetes, run by Insel Gruppe AG, University Hospital Bern at 1 site in Switzerland.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of this study it to assess whether the continuous glucose monitor system Dexcom G6® can be reliably used for perioperative glucose monitoring in 20 prediabetic or diabetic patients undergoing abdominal surgery in terms of data continuity, accuracy and patient tolerability. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Diabetes Mellitus, Prediabetes
How many people
20 participants
Where
1 siteSwitzerland
Study dates
13 Aug 2019to 1 Mar 2020
How long will I take part?
3 Weeks
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: The study will involve a total of 20 adults with pre-diabetes, type 1 or type 2 diabetes who will undergo elective abdominal surgery at the University Hospital Bern.

Who may be able to join

  • Aged ≥18 years
  • Pre-diabetic (HbA1c 5.7-6.5%) or diabetic (regardless of aetiology)
  • Scheduled to have elective abdominal surgery at the University Hospital Bern
  • Surgery duration >2 hours

Who cannot join

  • Planned MRI procedure during hospitalization
  • Inability to follow procedures
  • Incapacity to give informed consent
  • Presence of extensive skin abnormalities at the sensor insertion site (upper arm)
  • Known allergic/irritative skin reactions to dressings/adhesives
  • Haematocrit values outside the normal range
Show all 9Show fewer
  • Patients with immunosuppression defined as neutrophil count <0.5x10^9/L
  • Patients on isolation precautions (contact, droplet, airborne)
  • Pregnancy or breast-feeding

Trial locations and contacts

1 site in 1 country.

Switzerland1 site
  • Department of Diabetes, Endocrinology, Clinical Nutrition and Metabolism, Inselspital, Bern University Hospital

    Bern, 3010

Other trials in Switzerland

About this study

Official title: Perioperative Continuous Glucose Monitoring in Patients Undergoing an Abdominal Surgery - an Observational Study

The purpose of this study it to assess whether the continuous glucose monitor system Dexcom G6® can be reliably used for perioperative glucose monitoring in 20 prediabetic or diabetic patients undergoing abdominal surgery in terms of data continuity, accuracy and patient tolerability.

Read the detailed description

The current recommended method for monitoring glucose control is bedside point of care capillary blood glucose testing. A significant limitation for this method is the frequency by which blood glucose testing is typically performed, at most 4-6 times daily. Continuous glucose monitoring (CGM) provides an alternative approach to measure glucose values with the advantage of greater frequency of monitoring as it is measured every few minutes.

Whilst CGM use in the outpatient setting is rising and has demonstrated benefits on glycaemic control, the accuracy of these devices perioperatively is less investigated. In this study the sixth-generation factory-calibrated real-time Dexcom G6® system will be used as a CGM and its glucose values perioperatively will be compared to the capillary glucose values which will be measured simultaneously by the Accu-Check Inform II (Roche Diagnostics) point-of-care blood glucose meter.

The Investigators aim to assess the feasibility and accuracy of perioperative CGM.

Keywords
perioperative glucose management, continuous glucose monitoring, diabetes
Medical subject headings
Diabetes Mellitus, Prediabetic State

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Sensor accuracy in the perioperative period

    Mean Absolute Relative Difference (MARD) between Dexcom G6 sensor glucose values and capillary blood glucose values measured using the Accu-Check Inform II meter in the perioperative period (%)

    Measured: 1 day

Secondary outcomes (38)
  1. Mean absolute relative difference between sensor glucose and reference glucose in the preoperative period (%)

    Mean absolute relative difference between sensor glucose and reference glucose (for reference values >3.9 and <10.0mmol/l, for reference values ≤3.9mmol/l, for reference values ≥10.0mmol/l) in the preoperative period (%)

    Measured: 1 week

  2. Mean absolute relative difference between sensor glucose and reference glucose in the postoperative period (%)

    Mean absolute relative difference between sensor glucose and reference glucose (for reference values >3.9 and <10.0mmol/l, for reference values ≤3.9mmol/l, for reference values ≥10.0mmol/l) in the postoperative period (%)

    Measured: 1-2 weeks

  3. Median absolute relative difference between sensor glucose and reference glucose in the preoperative period (%)

    Median absolute relative difference between sensor glucose and reference glucose (for reference values >3.9 and <10.0mmol/l, for reference values ≤3.9mmol/l, for reference values ≥10.0mmol/l) in the preoperative period (%)

    Measured: 1 week

  4. Median absolute relative difference between sensor glucose and reference glucose in the perioperative period (%)

    Median absolute relative difference between sensor glucose and reference glucose (for reference values >3.9 and <10.0mmol/l, for reference values ≤3.9mmol/l, for reference values ≥10.0mmol/l) in the perioperative period (%)

    Measured: 1 day

  5. Median absolute relative difference between sensor glucose and reference glucose in the postoperative period (%)

    Median absolute relative difference between sensor glucose and reference glucose (for reference values >3.9 and <10.0mmol/l, for reference values ≤3.9mmol/l, for reference values ≥10.0mmol/l) in the postoperative period (%)

    Measured: 1-2 weeks

  6. Percentage of sensor measurements in the preoperative period within the limits specified by the International Organization of Standardization (ISO) : 15197:2013 criteria

    Proportion of sensor measurements in the preoperative period within ±15% of reference glucose if the reference value is ≥5.6mmol/l and within 0.8mmol/l if the reference values is <5.6mmol/l (%)

    Measured: 1 week

  7. Percentage of sensor measurements in the perioperative period within the limits specified by the ISO: 15197:2013 criteria

    Proportion of sensor measurements in the perioperative period within ±15% of reference glucose if the reference value is ≥5.6mmol/l and within 0.8mmol/l if the reference values is <5.6mmol/l (%)

    Measured: 1 day

  8. Percentage of sensor measurements in the postoperative period within the limits specified by the ISO: 15197:2013 criteria

    Proportion of sensor measurements in the postoperative period within ±15% of reference glucose if the reference value is ≥5.6mmol/l and within 0.8mmol/l if the reference values is <5.6mmol/l (%)

    Measured: 1-2 weeks

  9. Bias and 95% limits of agreement of sensor glucose compared to reference glucose in the preoperative period

    Calculation of bias and 95% limits of agreement of sensor glucose compared to reference glucose in the preoperative period

    Measured: 1 week

  10. Bias and 95% limits of agreement of sensor glucose compared to reference glucose in the perioperative period

    Calculation of bias and 95% limits of agreement of sensor glucose compared to reference glucose in the perioperative period

    Measured: 1 day

  11. Bias and 95% limits of agreement of sensor glucose compared to reference glucose in the postoperative period

    Calculation of bias and 95% limits of agreement of sensor glucose compared to reference glucose in the postoperative period

    Measured: 1-2 weeks

  12. Clarke error grid analysis in the preoperative period

    Proportion of sensor glucose values in Clark's error grid zones (A, B, A+B, C, D, E)in the preoperative period (%)

    Measured: 1 week

  13. Clarke error grid analysis in the perioperative period

    Proportion of sensor glucose values in Clark's error grid zones (A, B, A+B, C, D, E) in the perioperative period (%)

    Measured: 1 day

  14. Clarke error grid analysis in the postoperative period

    Proportion of sensor glucose values in Clark's error grid zones (A, B, A+B, C, D, E) in the postoperative period (%)

    Measured: 1-2 weeks

  15. Sensor availability in the preoperative period (%)

    Proportion of study period with available sensor glucose values in the preoperative period

    Measured: 1 week

  16. Sensor availability in the perioperative period (%)

    Proportion of study period with available sensor glucose values in the perioperative period

    Measured: 1 day

  17. Sensor availability in the postoperative period (%)

    Proportion of study period with available sensor glucose values in the postoperative period

    Measured: 1-2 weeks

  18. Number of sensor replacement events in the preoperative period

    Number of times that the sensor needed to be replaced in the preoperative period

    Measured: 1 week

  19. Number of sensor replacement events in the perioperative period

    Number of times that the sensor needed to be replaced in the perioperative period

    Measured: 1 day

  20. Number of sensor replacement events in the postoperative period

    Number of times that the sensor needed to be replaced in the postoperative period

    Measured: 1-2 weeks

  21. Number of adverse device effects in the preoperative period

    Adverse event related to the use of study devices (e.g. skin irritative and allergic reactions, bleeding) in the preoperative period

    Measured: 1 week

  22. Number of adverse device effects in the perioperative period

    Adverse event related to the use of study devices (e.g. skin irritative and allergic reactions, bleeding) in the perioperative period

    Measured: 1 day

  23. Number of adverse device effects in the postoperative period

    Adverse event related to the use of study devices (e.g. skin irritative and allergic reactions, bleeding) in the postoperative period

    Measured: 1-2 weeks

  24. Percentage of time in the preoperative period with sensor glucose levels within target range

    Proportion of time in the preoperative period with sensor glucose levels between 3.9-10.0mmol/l

    Measured: 1 week

  25. Percentage of time in the perioperative period with sensor glucose levels within target range

    Proportion of time in the perioperative period with sensor glucose levels between 3.9-10.0mmol/l

    Measured: 1 day

  26. Percentage of time in the postoperative period with sensor glucose levels within target range

    Proportion of time in the postoperative period with sensor glucose levels between 3.9-10.0mmol/l

    Measured: 1-2 weeks

  27. Percentage of time in the preoperative period with sensor glucose levels below target range

    Proportion of time in the preoperative period with sensor glucose levels below 3.9mmol/l

    Measured: 1 week

  28. Percentage of time in the perioperative period with sensor glucose levels below target range

    Proportion of time in the perioperative period with sensor glucose levels below 3.9mmol/l

    Measured: 1 day

  29. Percentage of time in the postoperative period with sensor glucose levels below target range

    Proportion of time in the postoperative period with sensor glucose levels below 3.9mmol/l

    Measured: 1-2 weeks

  30. Percentage of time in the preoperative period with sensor glucose levels above target range

    Proportion of time in the preoperative period with sensor glucose levels above 10.0mmol/l

    Measured: 1 week

  31. Percentage of time in the perioperative period with sensor glucose levels above target range

    Proportion of time in the perioperative period with sensor glucose levels above 10.0mmol/l

    Measured: 1 day

  32. Percentage of time in the postoperative period with sensor glucose levels above target range

    Proportion of time in the postoperative period with sensor glucose levels above 10.0mmol/l

    Measured: 1-2 weeks

  33. Mean sensor glucose value in the preoperative period

    Mean value of the sensor glucose levels in the preoperative period

    Measured: 1 week

  34. Mean sensor glucose value in the perioperative period

    Mean value of the sensor glucose levels in the perioperative period

    Measured: 1 day

  35. Mean sensor glucose value in the postoperative period

    Mean value of the sensor glucose levels in the postoperative period

    Measured: 1-2 weeks

  36. Standard deviation of sensor glucose levels in the preoperative period

    Standard Deviation of the sensor glucose levels in the preoperative period

    Measured: 1 week

  37. Standard deviation of sensor glucose levels in the perioperative period

    Standard Deviation of the sensor glucose levels in the perioperative period

    Measured: 1 day

  38. Standard deviation of sensor glucose levels in the postoperative period

    Standard Deviation of the sensor glucose levels in the postoperative period

    Measured: 1-2 weeks

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted2 May 2019
  2. Study start13 Aug 2019
  3. Primary completion26 Feb 2020
  4. Study completion1 Mar 2020

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
20 participants (actual)
Target duration
3 Weeks
IDs, dates and publications
ClinicalTrials.gov ID
NCT03935919
Sponsor's protocol ID
GluPop
Acronym
GluPop
Status last verified
Apr 2020
First submitted
28 Apr 2019
Last updated
8 Apr 2020
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

An observational study of Diabetes Mellitus and Prediabetes, run by Insel Gruppe AG, University Hospital Bern at 1 site in Switzerland.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 8 Apr 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Switzerland. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Sensor accuracy in the perioperative period (time frame: 1 day). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Apr 2020.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in