Trial summary
Trauma to the extremities such wrist, ankle, limb is very common and affects all population groups. It constitutes a significant public health issue. Standard radiography remains the basic imaging tool. However, as a 2-dimensional (2D) imaging modality it lacks sensitivity and specificity. Read more about this study
- Who is it for?
- Ages 18 to 99 years
- Conditions the study is for
- Fracture
- What is being tested?
- Tomo-E scan and Radiograph
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 30 participants
- Where
- 1 siteUnited States
- Study dates
- 5 Nov 2019to 3 Nov 2021
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 99 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Age 18 or older
- Undergone radiographic imaging of wrist for presumed or known scaphoid, wrist or distal radius fractures within 2 weeks or are scheduled to undergo such imaging.
- Able to provide informed consent
Who cannot join
- Patients will an intervening surgical procedure performed prior to study imaging.
- Institutionalized subject (prisoner or nursing home patient)
Trial locations and contacts
1 site in 1 country.
United States1 site
University of North Carolina at Chapel Hill
Chapel Hill, North Carolina, 27599
About this study
Trauma to the extremities such wrist, ankle, limb is very common and affects all population groups. It constitutes a significant public health issue. Standard radiography remains the basic imaging tool. However, as a 2-dimensional (2D) imaging modality it lacks sensitivity and specificity. Misdiagnosis rates are known to be high, especially for non-displaced fractures of the scaphoid and talus as well as erosions due to rheumatoid arthritis. Misdiagnosis leads to over treatment and unnecessary loss of productivity and quality of life including 6-12 weeks in a cast. Missed fractures can result in a chronic, non-healing fracture that may require surgical fixation and early arthritis of the joint. From a physician perspective, a missed diagnosis can result in a lawsuit and an expensive settlement/penalty.
Computed tomography (CT) offers high resolution and excellent visualization of bone and joint morphology, and Magnetic Resonance Imaging (MRI) delivers soft tissue and cartilage visibility. However, cost, space and workflow related issues make them prohibitive for small orthopedic clinics. Although the radiation dose of a CT scan has been reduced considerably in recent years, it is still significantly higher than a regular radiograph. The whole-body scanners also have difficulties in imaging patients in portable and weight-bearing conditions. Dedicated extremity CT scanners have been commercialized recently in an attempt to address the current deficiency. They still suffer from higher cost and at such have a limited installation base.
Read the detailed description
The aim of this one-year study is to demonstrate Tomo-E's clinical utility for diagnosis of wrist fractures. Tomo-E is a compact and stationary device that utilizes a distributed carbon nanotube (CNT) x-ray source array that will be specially designed for extremity imaging to collect all the projection views without any mechanical motion.
- Conditions
- Fracture
- Being tested
- Tomo-E scan, Radiograph
- Keywords
- Scaphoid Fracture, Wrist Fracture, Distal Radius Fracture
- Medical subject headings
- Fractures, Bone, Wrist Fractures
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Tomo-E scanDevice
Also called Digital Tomosynthesis
High-resolution limited-angle tomography positioning and examination will vary depending on injury.
RadiographDevice
Standard of Care radiographic imaging of wrist.
| Study group | Role | What they receive |
|---|---|---|
| All Participants | Experimental | Participants that have undergone standard of care, conventional 2D radiographic imaging of wrist for presumed or known scaphoid, wrist or distal radius fractures will receive the Tomo-E scans within two weeks. Receives: Device: Tomo-E scan; Device: Radiograph |
What is being measured
The primary outcome is the main question the study is designed to answer.
Sensitivity
The sensitivity of Tomo-E is defined as the ability of readers (radiologists) to detect wrist fractures in patients. Diagnostic accuracy will be defined by the presence of a fracture as clinically determined by the attending orthopedic surgeon. All Tomo-E scans will be reviewed in a standardized reader study at the conclusion of all study imaging to determine the overall sensitivity of the device.
Measured: 8 months
Secondary outcomes (1)
Specificity
The specificity of Tomo-E is defined as the ability to distinguish between individuals that do not have a wrist fracture. Diagnostic accuracy will be defined by the presence of a fracture as defined clinically by the attending orthopedic surgeon. All Tomo-E scans will be reviewed in a standardized reader study at the conclusion of all study imaging to determine the overall specificity of the device.
Measured: 8 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted21 Jun 2019
- Study start5 Nov 2019
- Primary completion3 Nov 2021
- Study completion3 Nov 2021
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for FractureStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 30 participants (actual)
Sponsor and investigators
- Lead sponsor
- University of North Carolina, Chapel Hill
- Sponsor type
- University, hospital or other
- Collaborators
- North Carolina Translational and Clinical Sciences Institute
- Responsible party
- Sponsor
- Investigators
- Daniel Nissman, MD, MPH, Principal investigator, UNC Chapel Hill
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03993691
- Sponsor's protocol ID
- 18-3132
- Status last verified
- Dec 2021
- First submitted
- 12 Jun 2019
- Last updated
- 3 Feb 2023
- Results posted
- Yes, on ClinicalTrials.gov
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- Yes: Identified individual data that supports the results will be shared beginning 9 to 36 months following publication provided the investigator who proposes to use the data has approval from an Institutional Review Board (IRB), Independent Ethics Committee (IEC), or Research Ethics Board (REB), as applicable, and executes a data use/sharing agreement with UNC.
Study at a glance
From the registry record, last updated by the sponsor on 3 Feb 2023. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Wrist Fracture Evaluation With a Desktop Orthopedic Tomosynthesis System
- ClinicalTrials.gov ID
- NCT03993691
- Acronym / sponsor ID
- 18-3132
- Conditions
- Fracture
- Keywords
- Scaphoid Fracture, Wrist Fracture, Distal Radius Fracture
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 30 participants (actual)
- Lead sponsor
- University of North Carolina, Chapel HillUniversity, hospital or other
- Collaborators
- North Carolina Translational and Clinical Sciences Institute
- Study start
- 5 Nov 2019 (actual)
- Primary completion
- 3 Nov 2021 (actual)
- Study completion
- 3 Nov 2021 (actual)
- First posted
- 21 Jun 2019 (actual)
- Results
- Posted 7 Nov 2022
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Trauma to the extremities such wrist, ankle, limb is very common and affects all population groups. It constitutes a significant public health issue. Standard radiography remains the basic imaging tool. However, as a 2-dimensional (2D) imaging modality it lacks sensitivity and specificity. Misdiagnosis rates are known to be high, especially for non-displaced fractures of the scaphoid and talus as well as erosions due to rheumatoid arthritis. Misdiagnosis leads to over treatment and unnecessary loss of productivity and quality of life including 6-12 weeks in a cast. Missed fractures can result in a chronic, non-healing fracture that may require surgical fixation and early arthritis of the joint. From a physician perspective, a missed diagnosis can result in a lawsuit and an expensive settlement/penalty.
Computed tomography (CT) offers high resolution and excellent visualization of bone and joint morphology, and Magnetic Resonance Imaging (MRI) delivers soft tissue and cartilage visibility. However, cost, space and workflow related issues make them prohibitive for small orthopedic clinics. Although the radiation dose of a CT scan has been reduced considerably in recent years, it is still significantly higher than a regular radiograph. The whole-body scanners also have difficulties in imaging patients in portable and weight-bearing conditions. Dedicated extremity CT scanners have been commercialized recently in an attempt to address the current deficiency. They still suffer from higher cost and at such have a limited installation base.
Detailed description
The aim of this one-year study is to demonstrate Tomo-E's clinical utility for diagnosis of wrist fractures. Tomo-E is a compact and stationary device that utilizes a distributed carbon nanotube (CNT) x-ray source array that will be specially designed for extremity imaging to collect all the projection views without any mechanical motion.
Study design
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| All Participants | Experimental | Device: Tomo-E scan, Device: RadiographParticipants that have undergone standard of care, conventional 2D radiographic imaging of wrist for presumed or known scaphoid, wrist or distal radius fractures will receive the Tomo-E scans within two weeks. |
Who may qualify
- Ages
- 18 to 99 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (3 listed)
- Age 18 or older
- Undergone radiographic imaging of wrist for presumed or known scaphoid, wrist or distal radius fractures within 2 weeks or are scheduled to undergo such imaging.
- Able to provide informed consent
Key exclusion criteria (2 listed)
- Patients will an intervening surgical procedure performed prior to study imaging.
- Institutionalized subject (prisoner or nursing home patient)
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Tomo-E scanAlso: Digital TomosynthesisHigh-resolution limited-angle tomography positioning and examination will vary depending on injury. | Device | All Participants |
| RadiographStandard of Care radiographic imaging of wrist. | Device | All Participants |
Primary outcome
Sensitivity
Time frame: 8 months
The sensitivity of Tomo-E is defined as the ability of readers (radiologists) to detect wrist fractures in patients. Diagnostic accuracy will be defined by the presence of a fracture as clinically determined by the attending orthopedic surgeon. All Tomo-E scans will be reviewed in a standardized reader study at the conclusion of all study imaging to determine the overall sensitivity of the device.
1 secondary outcome
Specificity
Time frame: 8 months
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 3 Feb 2023.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Individual participant dataSharing planned: Yes. Identified individual data that supports the results will be shared beginning 9 to 36 months following publication provided the investigator who proposes to use the data has approval from an Institutional Review Board (IRB), Independent Ethics Committee (IEC), or Research Ethics Board (REB), as applicable, and executes a data use/sharing agreement with UNC.
Related trials for Fracture
Active, not recruitingPhase 2
BDSF Vs DHS With Anterotational Screw in Vertical FNF
Evaluation of BDSF in FNF
Active, not recruitingPhase 2
Stoppa Approach Vs Anterior & Posterior Fixation in Management of BC Fracture Acetabulum
Evaluation of Isolated Stoppa Approach in BC Fracture Acetabulum
Not yet recruiting
Allograft vs. Autograft Nonunion
Nonunion Fracture
Not yet recruiting
Outpatient Floor Pedal Bike Utilization
Femur Fracture, Tibia Fracture
Not yet recruiting
Repair of Extra-articular Fractures of the Metacarpals and First Phalanges of the Long Fingers
Hand Fractures
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Daniel Nissman, MD, MPH principal investigator
UNC Chapel Hill
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Tomo-E scan and Radiograph in people with Fracture, run by University of North Carolina, Chapel Hill at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 3 Feb 2023. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 7 Nov 2022). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Sensitivity (time frame: 8 months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 3 Feb 2023.