AzTrials
AzTrials

Radial Artery Injury at Wrist and Hand LevelOPEN-RadialNCT04002791

Patent Hemostasis With Vasoband Versus TR Band

A study testing VasoBand in people with Radial Artery Injury at Wrist and Hand Level, run by Total Cardiovascular Solutions at 1 site in India.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

In patients referred for cardiac catheterization to be performed using transradial access, a randomized comparison will be performed with the primary endpoint of patency of radial artery at the time of application of hemostatic compression band. Read more about this study

Who is it for?
Ages 18 to 99 years
What is being tested?
VasoBand
Type of treatment
Medical device
Could I receive a placebo?
Yes, some participants may receive a placebo
How many people
253 participants
Where
1 siteIndia
Study dates
16 Mar 2019to 16 Oct 2019
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 99 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients referred for cardiac catheterization undergoing transradial access

Who cannot join

  • Previous ipsilateral radial artery cannulation, oral systemic anticoagulation therapy, thrombolytic therapy in the previous 7 days.

Trial locations and contacts

1 site in 1 country.

India1 site
  • Apex Heart Institute

    Ahmedabad, Gujarat

Other trials in India

About this study

Official title: Randomized COmparison of Isolated Radial Artery ComPrEssioN Versus Radial and Ipsilateral Ulnar Artery Compression in Achieving Patent Hemostasis: OPEN-Radial Trial

In patients referred for cardiac catheterization to be performed using transradial access, a randomized comparison will be performed with the primary endpoint of patency of radial artery at the time of application of hemostatic compression band. The single radial only TR-Band (Terumo, Japan) will be compared to the dual balloon Vasoband (Vasoinnovations, USA) capable of ipsilateral ulnar artery compression.

Read the detailed description

Introduction:

TRA is increasing in utilization across the world due to its established benefits of reduction in access site complications, cost, and increase in patient comfort (1). The most common structural consequence of TRA is radial artery occlusion (RAO). It occurs in 2-10% of patients undergoing TRA (2). Several pharmacologic as well as non-pharmacologic practices have been associated with RAO. Maintaining a hardware profile smaller than the inner diameter of radial artery has been associated with better radial artery patency rates after the procedure (3). Use of unfractionated heparin and other parenteral anticoagulants administered during the procedure has also been associated with reduction in RAO, with a dose-dependent effect with better reduction with higher doses of heparin (4,5).

One of the most effective intervention for reduction of RAO is avoidance of flow cessation in radial artery during hemostatic compression (6). This technique, called "patent hemostasis", has been shown to unequivocally and sizably reduce the incidence of RAO. In patients with small diameter radial arteries as well as low blood pressures, the ability to achieve and maintain patent hemostasis has been observed to be lower than those otherwise. In view of the co-dominant nature of forearm arterial circulation, the radial and ulnar arteries are interdependent and compression of ipsilateral ulnar artery has been shown to increase flow as well as peak flow velocity in the radial artery (7). Ipsilateral ulnar artery compression during hemostatic compression of a punctured radial artery, has been shown to sizably and significantly reduce the incidence of RAO compared to patent hemostasis (8). Randomized and observational datasets utilizing this technique published so far have been using two devices to achieve radial and ulnar compression, with difficult ergonomics leading to frequent dislodgment of ulnar compression during the radial artery hemostatic process.

The investigators intend to study the comparative efficacy of the first dedicated dual compression device in achieving patent hemostasis compared to the current popular radial artery compression device.

Patients and Methods:

Patients referred for diagnostic cardiac catheterization using TRA will be screened. Those providing written informed consent, will be enrolled in the study. A transradial cardiac catheterization will be performed using the standard technique as described below.

Catheterization Technique:

After sterile preparation as well as local anesthetic infiltration, 5 French hydrophilic introducer sheath will be introduced in the radial artery using standard puncture technique (9). Once the introducer is in the radial artery lumen, 200 µg of nitroglycerin, 2.5 mg of verapamil and 5000 IU of unfractionated heparin will be administered intra-arterially. 5 French or lower profile hardware will be used as per operator discretion to complete the procedure.

Once the procedure is completed, the patient will be randomized to:

Group 1, which will include patients receiving hemostatic compression using the current standard of care TR band (Terumo Corporation, Japan). The band will be applied according to the instructions for use, with optimal pressure applied to achieve full hemostasis.

Group 2, will consist of patients who will receive Vaso-band (VasoInnovations, Inc, USA), applied according to instructions for use, with ulnar balloon inflated for the first 60 minutes of radial artery hemostatic compression, with the radial balloon inflated to obtain full hemostasis, after the sheath is removed.

Primary Study End-point: Radial artery patency at 0-15 minutes after application of radial artery hemostatic compression.

Monitoring of Patency:

The radial artery patency will be monitored immediately after application of the band using reverse Barbeau test in both groups, and patency will be re-evaluated at 15 minutes after band application, 30 minutes after band application, 60 minutes after band application, as well as upon removal of the band at 120 minutes.

If longer duration of application of pressure with the band is necessary in either group to achieve hemostasis, the bands will be applied for longer duration and the adequacy of hemostasis will be evaluated every 15 minutes after 120-minute duration and the band removed once adequately adequate hemostasis has been achieved.

Radial patency will be assessed at 60 minutes after the band is removed.

Baseline demographic as well as procedural data, pharmacologic data, as well as elaborately data will be collected on every patient.

Statistical Analysis Plan:

Categorical variables will be expressed as proportions, and differences between the two groups will be assessed using chi-square test, or Pearson test as deemed appropriate. Numeric variables will be assessed for normality of the distribution, and will be expressed as mean and standard deviation for normally distributed variables, and median as well as interquartile range for those without normal distribution. Parametric tests will be used to compare differences between the two groups for normally distributed numeric variables, and nonparametric tests will be used in those variables with a non-normal distribution. Multivariable analysis if necessary, will be performed using forward selection binary logistic regression for categorical dependent variable and linear regression for numeric variables. Received operative characteristic derived c-statistic will be used to assess the stability of the model.

Sample Size Calculation:

Based on the available literature, using the current standard of care TR band, patent hemostasis defined as patency of radial artery during hemostatic compression at 15 minutes into compression is achievable in 75% of patients undergoing TRA. The only published randomized trial using prophylactic ipsilateral ulnar artery compression during radial artery hemostatic compression has shown 96% achievement of patent hemostasis at 15 minutes after onset of compression. Using this using these data, using a chi-square model, a sample size of 250 to 300 patients equally divided between two groups, is necessary to achieve a 90% power with an alpha editor of 0.05. Expecting a 10% crossover rate will be accommodated a sample size of 200 patients will be needed. After randomizing 200 patients, an interim analysis will be performed. If event rates are low, the sample-size will be increased to 350 patients.

Being tested
VasoBand

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • VasoBandDevice

    Dual-bladder radial artery hemostatic compression device capable of ipsilateral ulnar artery compression

Study groups in NCT04002791
Study groupRoleWhat they receive
Group 1: TR Band ArmPlacebo comparatorPatients will receive hemostatic compression using the current standard of care TR band (Terumo Corporation, Japan). The band will be applied according to the instructions for use, with optimal pressure applied using "Patent hemostasis protocol" to achieve full hemostasis.
Receives: Device: VasoBand
Group 2: Vaso-band ArmActive comparatorPatients will receive Vaso-band (VasoInnovations, Inc, USA), applied with ulnar balloon inflated with 15 ml of air, and the radial balloon inflated after the sheath is removed, to apply optimal pressure for obtaining full hemostasis. Ulnar balloon will be deflated after 60 minutes of radial artery hemostatic compression.
Receives: Device: VasoBand

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of Patients Who Achieved Patent Hemostasis

    Patent hemostasis achievement at 0-15 minutes after onset of radial artery hemostatic compression

    Measured: 0-15 minutes

Secondary outcomes (1)
  1. Number of Participants With Radial Artery Occlusion One Hour After Removal of Hemostatic Compression

    Absence of Patency of radial artery at 1-hour after removal of hemostatic compression

    Measured: 0-60 minutes

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted1 Jul 2019
  2. Study start16 Mar 2019
  3. Primary completion16 Oct 2019
  4. Study completion16 Oct 2019

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Prevention
Allocation
Randomised
Intervention model
Parallel groups
Model description
Randomized comparison of patent hemostasis achievement with single bladder radial artery compression device with a dual-bladder ulnar compression capable radial artery compression device.
Masking
None (open label)
Enrolment
253 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04002791
Sponsor's protocol ID
A98
Acronym
OPEN-Radial
Status last verified
Oct 2020
First submitted
10 May 2019
Last updated
13 Nov 2020
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No: Individual participant data will be deidentified and will not be shared

Questions about this trial

What is this clinical trial studying?

A study testing VasoBand in people with Radial Artery Injury at Wrist and Hand Level, run by Total Cardiovascular Solutions at 1 site in India.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 13 Nov 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in India. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. Some participants in this study may receive a placebo. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 13 Nov 2020). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Number of Patients Who Achieved Patent Hemostasis (time frame: 0-15 minutes). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 13 Nov 2020.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in