Trial summary

Every year millions of mammograms are performed worldwide, representing the primary examination for the early diagnosis of breast cancer. Despite continuous advances in medicine and technology, an aspect of mammography has not changed in over fifty years: the breast is still compressed on the detector because this… Read more about this study

Who is it for?
Ages 18 months and older, women only
Conditions the study is for
Mammography, Breast Cancer
What is being tested?
Self compression arm
Could I receive a placebo?
No, everyone receives an active treatment
How many people
502 participants
Where
1 siteItaly
Study dates
25 Jan 2018to 31 Dec 2020
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 months and older
  • Women only
  • No healthy volunteers
  • Child, Adult, Older adult

Who may be able to join

  • Women in follow-up after surgery
  • Symptomatic women undergoing mammography
  • Early diagnosis in asymptomatic women outside the organized screening program (these women are predominantly aged 40-44 / 75-85)
  • Women with familiar risk

Who cannot join

  • Augmentation prostheses
  • Women in screening with active invitation
  • Physical impossibility to use the self-compression command
  • Inability to provide consent

Trial locations and contacts

1 site in 1 country.

Italy1 site
  • Laura Canovi

    Reggio Emilia, RE, 42123

Other trials in Italy

About this study

Official title: Self-compression Mammography in Clinical Practice: A Randomized Clinical Trial Compared to Standard Compression Mammography

Every year millions of mammograms are performed worldwide, representing the primary examination for the early diagnosis of breast cancer. Despite continuous advances in medicine and technology, an aspect of mammography has not changed in over fifty years: the breast is still compressed on the detector because this allows to reduce the thickness of the breast thus improving the quality of the diagnostic image and reducing the dose of radiation necessary to obtain a clear image. Many women perceive as painful this compression, including women who have been treated for breast cancer.

Pain can discourage asymptomatic women to present themselves periodically to screening mammography, while an increasing number of women in follow-up after conservative surgery have to withstand the pain caused by mammography.

Read more

Some studies mention various factors that are responsible for pain when performing mammography: breast sensitivity, anxiety level, expected pain and staff attitude. Some studies have also identified breast density, breast volume and menstrual phase as other influencing factors, although not all studies support these hypothesis. The technical characteristics of the equipment can greatly affect annoyance, sense of oppression, pain. The technological proposals to reduce the discomfort of the patients concern various items: flexible compressors, self-compression devices under the supervision of the technician who performs the positioning and the minimum initial compression, environmental factors such as equipment noise reduction, chromatic, sound and sensory effects (eg: aromatic diffusers).

The aim of our study is to evaluate the effectiveness of the self-compression compared to the standard one, in reducing annoyance, a sense of oppression and pain, and to evaluate the difference of the average glandular dose given to the woman for each projection.

Self-compression may help reaching better compression tolerating the discomfort and pain induced thus allowing to achieve a lower thickness, a lower glandular dose and a better image.

Being tested
Self compression arm
Keywords
Pain and discomfort
Medical subject headings
Breast Neoplasms, Pain

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Self compression armOther

    The optimal compression level up will be under the supervision of the radiographer who will interpose the compression when a level is reached beyond which there is no further reduction in thickness (15 daN). If the woman stops at a compression of less than 10 daN and that the radiographer considers not adequate to perform a quality mammogram, the radiographer will perform the compression in conventional mode and record the passage of compression mode.

Study groups in NCT04009278
Study groupRoleWhat they receive
1. Self-compression armExperimentalIntervention consist in a explanation by the radiographer to the woman how to use the self-compression device, then position the woman's breasts and reach a compression of 5 daN, that this is a minimum but sub-optimal level of compression, and that at that point the woman will have to complete the compression to reach the optimal compression level up to an acceptable pain.
Receives: Other: Self compression arm
2. Control armNo interventionThe mammography will be performed as normal clinical practice, with compression controlled by the radiographer.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Average glandular dose administered (mSv)

    Average glandular dose administered during mammography is automatically computed by the machine according to an algorithm using the data on the quantity of radiation emitted and the radiation captured by the detector.

    Measured: This outcome is measured at the baseline mammography.

  2. Image quality: radiographers' scale.

    Radiographers evaluate the image quality after exam with a radiographer specific 3-item scale (contrast, resolution, compression) on a 0 to 5 point scale. Higher values mean better quality.

    Measured: This outcome is measured at the baseline mammography.

  3. Image quality: radiologists' scale.

    Radiologists evaluate the image quality after exam a radiologist specific 3-item scale (contrast, resolution, compression) on a 0 to 5 point scale. Higher values mean better quality.

    Measured: This outcome is measured at the baseline mammography.

Secondary outcomes (8)
  1. Breast thickness at the time of exposure (cm)

    Breast thickness is measured automatically by the machine. This endpoint will be evaluated using single exposure as statistical unit, taking into account the autocorrelation of the 4 exposures in the same woman.

    Measured: This outcome is measured at the baseline mammography.

  2. Maximum compression (daN)

    Compression is measured automatically by the machine. This endpoint will be evaluated using single exposure as statistical unit, taking into account the autocorrelation of the 4 exposures in the same woman.

    Measured: This outcome is measured at the baseline mammography.

  3. Pain during compression

    visual assessment scale

    Measured: pain will be evaluated immediately after baseline mammography execution

  4. Memory of pain in previous mammography

    visual assessment scale

    Measured: before the follow up mammography, i.e. approximately 1 year after baseline mammography

  5. Anxiety

    questionnaire: State Trait Anxiety Inventory for adults - form Y (D. Spielberger).

    The scale has 20 items for assessing trait anxiety and 20 for state anxiety. All items are rated on a 4-point scale. Higher scores indicate greater anxiety.

    Measured: Anxiety will be measured just before the baseline mammography and before the follow up mammography, i.e. approximately 1 year after baseline mammography.

  6. Discomfort

    Discomfort will be measured with a one-item scale with five-point range (no, slight, moderate, considerable and severe discomfort).

    Measured: Discomfort will be measured just after the baseline mammography.

  7. Execution time of the exam:

    We evaluate: - total time (from randomization to close examination). Times are automatically registered by the radiology information system.

    • Second breast time (from the acquisition of the second right breast projection to the acquisition of the second left breast projection)

    Measured: This outcome is measured at the baseline mammography.

  8. Participation in follow up mammography

    Number of women presenting to follow up mammography (1 year +/-2 months)/number of recruited women referred to follow up mammography after 1 year

    Measured: 1 year (+/- 2 months) after baseline mammography

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted5 Jul 2019
  2. Study start25 Jan 2018
  3. Primary completion31 Jul 2019
  4. Study completion31 Dec 2020

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Supportive care
Allocation
Randomised
Intervention model
Parallel groups
Model description
The study will be proposed to women presenting for a clinical mammography . Randomization will be determined by the machine's order entry system. All women will have a mammogram performed on the Pristina. In the control arm, mammography will be performed as normal clinical practice, with compression controlled by the radiographer. In the experimental arm the radiographer will first explain to the woman how to use the self-compression device, then position the woman's breasts and reach a compression of 5 daN, that this is a minimum but sub-optimal level of compression, and that at that point the woman will have to complete the compression to reach the optimal compression level up to an acceptable pain.
Masking
Single blind
Who is masked
Outcomes assessor
Enrolment
502 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04009278
Sponsor's protocol ID
RCT Pristina 2/TR
Acronym
Pristina2/TR
Status last verified
Jan 2021
First submitted
9 Jan 2019
Last updated
12 Jun 2025
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: The differences in average glandular dose between the two groups will be compared with a student test if the distributions can be assimilated to a normal one and with non-parametric test in case of non-normality of the distributions. If the average glandular dose is not lower in the study group (superiority test) and / or the proportion of women with suboptimal compression (\<10daN) and\> = in the experimental group, the image quality measured with a qualitative subjective scale of the radiologist with a non-parametric test (superiority test). For secondary endpoints, the results will be compared between the two arms with student tests for the medium with normal distribution, non-parametric tests for non-normal distributions, while for the proportions a chi-square test will be performed.

Publications

  • Miller D, Livingstone V, Herbison P. Interventions for relieving the pain and discomfort of screening mammography. Cochrane Database Syst Rev. 2008 Jan 23;2008(1):CD002942. doi: 10.1002/14651858.CD002942.pub2.

    PubMed 18254010
  • Andrews FJ. Pain during mammography: implications for breast screening programmes. Australas Radiol. 2001 May;45(2):113-7. doi: 10.1046/j.1440-1673.2001.00889.x.

    PubMed 11380352
  • Poulos A, McLean D, Rickard M, Heard R. Breast compression in mammography: how much is enough? Australas Radiol. 2003 Jun;47(2):121-6. doi: 10.1046/j.0004-8461.2003.01139.x.

    PubMed 12780439
  • Mercer CE, Hogg P, Lawson R, Diffey J, Denton ER. Practitioner compression force variability in mammography: a preliminary study. Br J Radiol. 2013 Feb;86(1022):20110596. doi: 10.1259/bjr.20110596.

    PubMed 23385990
  • Mendat CC, Mislan D, Hession-Kunz L. Patient comfort from the technologist perspective: factors to consider in mammographic imaging. Int J Womens Health. 2017 May 18;9:359-364. doi: 10.2147/IJWH.S129817. eCollection 2017.

    PubMed 28572739
  • Davey B. Pain during mammography: possible risk factors and ways to alleviate pain. Radiography. 2007;13:5

  • de Groot JE, Branderhorst W, Grimbergen CA, den Heeten GJ, Broeders MJM. Towards personalized compression in mammography: a comparison study between pressure- and force-standardization. Eur J Radiol. 2015 Mar;84(3):384-391. doi: 10.1016/j.ejrad.2014.12.005. Epub 2014 Dec 13.

    PubMed 25554008
  • Feder K, Grunert JH. Is Individualizing Breast Compression during Mammography useful? - Investigations of pain indications during mammography relating to compression force and surface area of the compressed breast. Rofo. 2017 Jan;189(1):39-48. doi: 10.1055/s-0042-119450. Epub 2016 Dec 21.

    PubMed 28002858
  • Guidelines for Quality Assurance in Mammography Screening, third edition, The National Cancer Screening Service Board 2008

  • de Groot JE, Broeders MJ, Grimbergen CA, den Heeten GJ. Pain-preventing strategies in mammography: an observational study of simultaneously recorded pain and breast mechanics throughout the entire breast compression cycle. BMC Womens Health. 2015;15:26. doi: 10.1186/s12905-015-0185-2. Epub 2015 Mar 15.

    PubMed 25783657
  • Van Goethem M, Mortelmans D, Bruyninckx E, Verslegers I, Biltjes I, Van Hove E, De Schepper A. Influence of the radiographer on the pain felt during mammography. Eur Radiol. 2003 Oct;13(10):2384-9. doi: 10.1007/s00330-002-1686-6. Epub 2002 Nov 14.

    PubMed 14534806
  • Lau S, Abdul Aziz YF, Ng KH. Mammographic compression in Asian women. PLoS One. 2017 Apr 18;12(4):e0175781. doi: 10.1371/journal.pone.0175781. eCollection 2017.

    PubMed 28419125
  • Taplin SH, Rutter CM, Finder C, Mandelson MT, Houn F, White E. Screening mammography: clinical image quality and the risk of interval breast cancer. AJR Am J Roentgenol. 2002 Apr;178(4):797-803. doi: 10.2214/ajr.178.4.1780797.

    PubMed 11906848
  • Shrestha S, Poulos A, The effect of verbal information on the experience of discomfort in mammography, Radiography, Volume 7, Issue 4, Pages 271-277; 2001

  • Kornguth PJ, Keefe FJ, Wright KR, Delong DM. Mammography pain in women treated conservatively for breast cancer. J Pain. 2000 Winter;1(4):268-74. doi: 10.1054/jpai.2000.7884.

    PubMed 14622609

Questions about this trial

What is this clinical trial studying?

A study testing Self compression arm in people with Mammography and Breast Cancer, run by Azienda USL Reggio Emilia - IRCCS at 1 site in Italy.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 12 Jun 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Average glandular dose administered (mSv) (time frame: This outcome is measured at the baseline mammography.). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04009278, which also lists 16 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 12 Jun 2025.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in