Mechanical VentilationNCT04012489
Breath and Air Stacking on Respiratory Mechanics in Tracheostomized Patients
A study testing Breath Stacking and Air Stacking in people with Mechanical Ventilation and Lung Infection, run by Brazilian Institute of Higher Education of Censa at 1 site in Brazil.
Trial summary
The researchers hypothesized that the aid of the resuscitator by the technique Air Stacking increase lung volume, promoting increased lung compliance and improvement of the ventilatory pattern. In addition, Air Stacking does not depend on patient collaboration. Read more about this study
- Who is it for?
- Ages 18 to 65 years
- Conditions the study is for
- Mechanical Ventilation, Lung Infection
- What is being tested?
- Breath Stacking and Air Stacking
- Type of treatment
- Surgery or procedure
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 20 participants
- Where
- 1 siteBrazil
- Study dates
- 25 Feb 2018to 14 May 2019
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 65 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Patients without mechanical ventilation for more than 72 hours
- Mucus hypersecretion (defined as the need for suctioning < 2-h intervals)
Who cannot join
- bronchospasm.
- Pleural effusion or pneumothorax undrained.
- Bronchopleural or tracheoesophageal fistula.
- Neuromuscular disease.
Trial locations and contacts
1 site in 1 country.
Brazil1 site
Luciano M Chicayban
Campos dos Goytacazes, Rio de Janeiro, 28015150
About this study
Official title: Comparison Between Breath Stacking and Air Stacking on Respiratory Mechanics and Ventilatory Pattern in Tracheostomized Patients: Randomized Crossover Trial
The researchers hypothesized that the aid of the resuscitator by the technique Air Stacking increase lung volume, promoting increased lung compliance and improvement of the ventilatory pattern. In addition, Air Stacking does not depend on patient collaboration. The objective of this study was to compare the effects of breath stacking and air stacking techniques on respiratory mechanics and ventilatory pattern in patients admitted to the ICU
- Conditions
- Mechanical Ventilation, Lung Infection
- Being tested
- Breath Stacking, Air Stacking
- Keywords
- Physical Therapy Modalities, Respiratory Care Units, Respiratory Mechanics
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Breath StackingProcedure or surgery
Patients were connected to a unidirectional valve coupled to artificial airway (tracheostomy), with bacteriological filter. The ventilator was coupled to the unidirectional valve to measure inspiratory volume mobilized in each cycle and a connection to adapt a manometer. The patient performed successive inspirations for a maximum period of 30 seconds or until unidirectional valve opening or volume increase was observed for 2 consecutive efforts. Ten cycles of the technique were performed, with an interval of 30 seconds.
Air StackingProcedure or surgery
The same system of monitoring and adaptation of the ventilometer and manometer was carried out. A manual resuscitator coupled to a unidirectional valve was used, both connected to the tracheostomy, with a filter interface. Slow and successive inspirations were performed through slow compression of the resuscitator until the maximum inspiratory pressure reached 40 cmH2O. Ten cycles of the technique were performed, with an interval of 30 seconds.
| Study group | Role | What they receive |
|---|---|---|
| Breath Stacking | Active comparator | Breath stacking: patients were connected to a unidirectional valve coupled to artificial airway (tracheostomy), with bacteriological filter. The ventilator was coupled to the unidirectional valve to measure inspiratory volume mobilized in each cycle and a connection to adapt a manometer. The patient performed successive inspirations for a maximum period of 30 seconds or until unidirectional valve opening or volume increase was observed for 2 consecutive efforts. Ten cycles of the technique were performed, with an interval of 30 seconds. Receives: Procedure: Breath Stacking |
| Air Stacking | Experimental | Air stacking: the same system of monitoring and adaptation of the ventilometer and manometer was carried out. A manual resuscitator coupled to a unidirectional valve was used, both connected to the tracheostomy, with a filter interface. Slow and successive inspirations were performed through slow compression of the resuscitator until the maximum inspiratory pressure reached 40 cmH2O. Ten cycles of the technique were performed, with an interval of 30 seconds. Receives: Procedure: Air Stacking |
What is being measured
The primary outcome is the main question the study is designed to answer.
Static compliance of respiratory system
Compliance was assessed through the occlusion maneuver at the end of inspiration, considering tidal volume, plateau pressure and PEEP. Three measurements were taken at each moment, the mean being used.
Measured: Baseline (before) and immediately after Breath Stacking or Air Stacking
Total Resistance of respiratory system
The total resistance of the respiratory system was evaluated through the occlusion maneuver at the end of the inspiration, considering the resistive pressure, measured by the difference between the maximum plateau pressure. Three measurements were taken at each moment, the mean being used.
Measured: Baseline (before) and immediately after Breath Stacking or Air Stacking
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted9 Jul 2019
- Study start25 Feb 2018
- Primary completion18 Oct 2018
- Study completion14 May 2019
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Mechanical VentilationStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- Single blind
- Who is masked
- Participant
- Enrolment
- 20 participants (actual)
Sponsor and investigators
- Lead sponsor
- Brazilian Institute of Higher Education of Censa
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Luciano Matos Chicayban, Brazilian Institute of Higher Education of Censa
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04012489
- Sponsor's protocol ID
- Air and Breath Stacking
- Status last verified
- Jul 2019
- First submitted
- 4 Jul 2019
- Last updated
- 9 Jul 2019
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
Study at a glance
From the registry record, last updated by the sponsor on 9 Jul 2019. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Comparison Between Breath Stacking and Air Stacking on Respiratory Mechanics and Ventilatory Pattern in Tracheostomized Patients: Randomized Crossover Trial
- ClinicalTrials.gov ID
- NCT04012489
- Acronym / sponsor ID
- Air and Breath Stacking
- Conditions
- Mechanical Ventilation, Lung Infection
- Keywords
- Physical Therapy Modalities, Respiratory Care Units, Respiratory Mechanics
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 20 participants (actual)
- Lead sponsor
- Brazilian Institute of Higher Education of CensaUniversity, hospital or other
- Study start
- 25 Feb 2018 (actual)
- Primary completion
- 18 Oct 2018 (actual)
- Study completion
- 14 May 2019 (actual)
- First posted
- 9 Jul 2019 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The researchers hypothesized that the aid of the resuscitator by the technique Air Stacking increase lung volume, promoting increased lung compliance and improvement of the ventilatory pattern. In addition, Air Stacking does not depend on patient collaboration. The objective of this study was to compare the effects of breath stacking and air stacking techniques on respiratory mechanics and ventilatory pattern in patients admitted to the ICU
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- Single blind (participant)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Breath Stacking | Active comparator | Procedure: Breath StackingBreath stacking: patients were connected to a unidirectional valve coupled to artificial airway (tracheostomy), with bacteriological filter. The ventilator was coupled to the unidirectional valve to measure inspiratory volume mobilized in each cycle and a connection to adapt a manometer. The patient performed successive inspirations for a maximum period of 30 seconds or until unidirectional valve opening or volume increase was observed for 2 consecutive efforts. Ten cycles of the technique were performed, with an interval of 30 seconds. |
| Air Stacking | Experimental | Procedure: Air StackingAir stacking: the same system of monitoring and adaptation of the ventilometer and manometer was carried out. A manual resuscitator coupled to a unidirectional valve was used, both connected to the tracheostomy, with a filter interface. Slow and successive inspirations were performed through slow compression of the resuscitator until the maximum inspiratory pressure reached 40 cmH2O. Ten cycles of the technique were performed, with an interval of 30 seconds. |
Who may qualify
- Ages
- 18 to 65 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (2 listed)
- Patients without mechanical ventilation for more than 72 hours
- Mucus hypersecretion (defined as the need for suctioning < 2-h intervals)
Key exclusion criteria (4 listed)
- bronchospasm.
- Pleural effusion or pneumothorax undrained.
- Bronchopleural or tracheoesophageal fistula.
- Neuromuscular disease.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Breath StackingPatients were connected to a unidirectional valve coupled to artificial airway (tracheostomy), with bacteriological filter. The ventilator was coupled to the unidirectional valve to measure inspiratory volume mobilized in each cycle and a connection to adapt a manometer. The patient performed successive inspirations for a maximum period of 30 seconds or until unidirectional valve opening or volume increase was observed for 2 consecutive efforts. Ten cycles of the technique were performed, with an interval of 30 seconds. | Procedure or surgery | Breath Stacking |
| Air StackingThe same system of monitoring and adaptation of the ventilometer and manometer was carried out. A manual resuscitator coupled to a unidirectional valve was used, both connected to the tracheostomy, with a filter interface. Slow and successive inspirations were performed through slow compression of the resuscitator until the maximum inspiratory pressure reached 40 cmH2O. Ten cycles of the technique were performed, with an interval of 30 seconds. | Procedure or surgery | Air Stacking |
Primary outcome
Static compliance of respiratory system
Time frame: Baseline (before) and immediately after Breath Stacking or Air Stacking
Compliance was assessed through the occlusion maneuver at the end of inspiration, considering tidal volume, plateau pressure and PEEP. Three measurements were taken at each moment, the mean being used.
Total Resistance of respiratory system
Time frame: Baseline (before) and immediately after Breath Stacking or Air Stacking
The total resistance of the respiratory system was evaluated through the occlusion maneuver at the end of the inspiration, considering the resistive pressure, measured by the difference between the maximum plateau pressure. Three measurements were taken at each moment, the mean being used.
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 9 Jul 2019.
Related trials for Mechanical Ventilation
Active, not recruiting
CT for Personalized Mechanical Ventilation
Ventilator-Induced Lung Injury, Sepsis Syndrome
Active, not recruitingObservational study
DIAPHRAGM STRENGTH AND LUNG VOLUMES
Mechanical Ventilation
Recruiting
Development and Preliminary Validation of Intelligent Video Laryngoscope for Emergency Use
Critically Ill Patients Requiring Mechanical Ventilation
Not yet recruiting
Mechanical Ventilator Adjustments and Patient Dyspnea
Respiratory Failure, Dyspnea During Mechanical Ventilation
Active, not recruitingObservational study
Potential Impact of the Use of the Application VentilO
Mechanical Ventilation Complication
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Breath Stacking and Air Stacking in people with Mechanical Ventilation and Lung Infection, run by Brazilian Institute of Higher Education of Censa at 1 site in Brazil.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 9 Jul 2019. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Brazil. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Static compliance of respiratory system (time frame: Baseline (before) and immediately after Breath Stacking or Air Stacking). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.