Heart Failure NYHA Class IIINCT04012944
SIRONA 2 Trial Heart Failure NYHA Class III
A study testing Cordella™ Pulmonary Artery Sensor System in people with Heart Failure NYHA Class III, run by Endotronix, Inc. at 7 sites in 3 countries.
Trial summary
This is a prospective, multi-center, open-label, single-arm CE-Mark trial to assess device safety and efficacy of the Cordella PA Sensor System in up to 75 New York Heart Association (NYHA) Class III Heart Failure patients who will receive the Cordella PA Sensor Implant. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Heart Failure NYHA Class III
- What is being tested?
- Cordella™ Pulmonary Artery Sensor System
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 81 participants
- Where
- 7 sitesin 3 countries
- Study dates
- 26 Jun 2019to Dec 2031
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Subject has given written informed consent
- Male or female, at least 18 years of age
- Diagnosis of HF ≥ 6 months with either preserved or reduced left ventricular ejection fraction (LVEF) and NYHA Class III HF at the time of Screening
- HF related hospitalization, HF treatment in a hospital day-care setting, or unplanned outpatient clinic HF visit within 12 months prior to consent and/or increase of N-terminal pro-Brain Natriuretic Peptide (NT-proBNP) (or Brain Natriuretic Peptide (BNP)) at time of Screening defined as:
- Subjects with LVEF ≤ 40%: NT-proBNP ≥ 1000 pg/mL (or BNP ≥ 250 pg/mL).
- Subjects with LVEF > 40%: NT-proBNP ≥ 700 pg/mL (or BNP ≥ 175 pg/mL). Thresholds for NT-proBNP and BNP (for both LVEF ≤ 40% and LVEF > 40%) will be corrected for body mass index (BMI) using a 4% reduction per BMI unit over 25 kg/m2
Show all 11Show fewer
- Subjects must be receiving appropriate medical management of HF for 3 months prior to Screening and clinically stable for at least 1 month prior to study entry
- Subjects who are physically able to hold the myCordella™ Patient Reader unit (approximate weight 600g) against the ventral thoracic surface for up to 2 minutes per day while in a seated position, as well as dock and undock the myCordella™ Patient Reader
- Subjects with sufficient eyesight, hearing, and mental capacity to respond to the myCordella™ Patient Reader's audio/visual cues and operate the myCordella™ Patient Reader
- Subject has sufficient Cellular and/or Wi- Fi Internet coverage at home
- Subject agrees to return to the treating Investigator for all scheduled follow up visits and can return to the hospital for follow up
Who cannot join
- Subjects with primary pulmonary hypertension
- Subjects with an active infection at the Cordella PA Sensor Implant Visit
- Subjects with history of pulmonary embolism or deep vein thrombosis
- Subjects who have had a major cardiovascular event (e.g., myocardial infarction, stroke) within 2 months of the Screening Visit
- Subjects whereby RHC is contraindicated
- Implanted with a Cardiac Rhythm Management (CRM) Device (Internal Cardiac Defibrillator (ICD) or pacemaker) or Cardiac Resynchronization Therapy (CRT)-Pacemaker (CRT-P) or CRT-Defibrillator (CRT-D) less than 90 days prior to screening visit
Show all 22Show fewer
- Any major surgery within 30 days of the Sensor Implant Visit.
- Subjects with a Glomerular Filtration Rate (GFR) <25 ml/min or who are on chronic renal dialysis
- Specific liver enzymes [Aspartate Aminotransferase (AST) (SGOT), and Alanine Aminotransferase (ALT) (SGPT) >3 times the upper limit of normal
- Received or are likely to receive an advanced therapy (e.g., mechanical circulatory support or lung or heart transplant) in the next 12 months
- Subjects with congenital heart disease or mechanical/tissue right heart valve(s)
- Subjects with known coagulation disorders
- Subjects with a hypersensitivity or allergy to platelet aggregation inhibitors including aspirin, clopidogrel, prasugrel, and ticagrelor; or patients unable to take dual antiplatelet or anticoagulants for one- month post implant
- Known history of life threatening allergy to contrast dye
- Subjects who are pregnant or breastfeeding
- Subjects who are unwilling or deemed by the Investigator to be unwilling to comply with the study protocol, or subjects with a history of non-compliance
- Severe illness, other than heart disease, which would limit survival to <1 year
- Subjects whose clinical condition, in the opinion of the Investigator, makes them an unsuitable candidate for the study
- Subjects enrolled in another investigational trial with an active Treatment Arm
- Subject who is in custody by order of an authority or a court of law
- Unrepaired severe valvular disease
- Subjects with an inferior vena cava (IVC) filter
Trial locations and contacts
7 sites in 3 countries.
7 sites in 3 countries
Germany3 sites
Uniklinik Köln, Klinik III für Innere Medizin Herzzentrum der Universität zu Köln
Cologne
Universitätsklinikum Giessen und Marburg GmbH, Standort Giessen Medizinische Klinik I, Abteilung Kardiologie und Angiologie
Giessen
Klinik für Kardiologie und Angiologie/ Studienambulanz Medizinische Hochschule Hannover (MHH)
Hanover
Belgium2 sites
Cardivascular Center OLV Aalst
Aalst
Ziekenhuis- Oost Limburg
Genk
Ireland2 sites
Mater Misericordiae University Hospital
Dublin
University Hospital Galway
Dublin
About this study
Official title: A Prospective, Multi-Center, Open-Label, Single-Arm Clinical Trial Evaluating the Safety and Efficacy of the Cordella™ Pulmonary Artery Sensor System in New York Heart Association (NYHA) Class III Heart Failure Patients (SIRONA 2 Trial)
This is a prospective, multi-center, open-label, single-arm CE-Mark trial to assess device safety and efficacy of the Cordella PA Sensor System in up to 75 New York Heart Association (NYHA) Class III Heart Failure patients who will receive the Cordella PA Sensor Implant.
Read the detailed description
The study objectives are:
- To establish that the Cordella PA Sensor can be safely delivered, deployed, and remain stable within the target pulmonary artery (PA) segment through 30 days post-implant.
- To compare Cordella PA Sensor System pressure measurements with fluid-filled catheter PA pressure measurements obtained by standard right heart catheterization (RHC) at 90 days post implant.
- Conditions
- Heart Failure NYHA Class III
- Being tested
- Cordella™ Pulmonary Artery Sensor System
- Keywords
- Heart Failure, Heart Diseases, Cardiovascular Disease
- Medical subject headings
- Heart Failure, Heart Diseases, Cardiovascular Diseases
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Cordella™ Pulmonary Artery Sensor SystemDevice
The Cordella PA Sensor System comprises seven subsystems that operate together to take daily Pulmonary Artery Pressure (PAP) readings at a patient's home and transmit the results to a care provider for evaluation.
- Cordella Sensor
- Cordella Delivery System
- myCordella Patient Reader
- Reader Dock
- Cordella Calibration Equipment (CalEQ)
- myCordella Hub
- Cordella Data Analysis Platform (CDAP).
| Study group | Role | What they receive |
|---|---|---|
| Cordella™ Pulmonary Artery Sensor System | Experimental | The Cordella PA Sensor System (CorPASS) is intended to measure, record, and transmit pulmonary artery pressure (PAP) data from NYHA Class III heart failure patients at home to clinicians for assessment and patient-centered heart failure management Receives: Device: Cordella™ Pulmonary Artery Sensor System |
What is being measured
The primary outcome is the main question the study is designed to answer.
Safety: Freedom from Adverse Events
To evaluate the primary safety endpoint: Freedom from AEs associated with use of the CorPASS through 30 days post Cordella PA Sensor implant, the number of subjects with and without any Adverse Device Events will be summarized.
Measured: 30 days
Accuracy of Cordella PA Sensor System pressure measurements, compared to standard-of-care fluid-filled catheter PA pressure measurements obtained by standard Right Heart Catheterization (RHC)
System accuracy will be compared to the accuracy of standard-of-care commercial products that use fluid-filled invasive catheters to measure PA pressure at 90 days post implant visit.
Measured: 90 days
Secondary outcomes (13)
Frequency of Adverse Events
Frequency of adverse events throughout the study
Measured: 30 days and 2 years
Device/system-related complications
The rate of device/system-related complications will be assessed throughout the study
Measured: 30 days and 2 years
Pressure sensor failure rate
Pressure sensor failure rate throughout the study
Measured: 30 days and 2 years
Accuracy using the Bland Altman Method
Accuracy of Cordella PA Sensor System pressure measurements, compared to standard-of-care fluid-filled catheter PA pressure measurements obtained by standard RHC using the Bland Altman method.
Measured: 90 days
Accuracy of Cordella PA Sensor pressure measurements
Accuracy of Cordella PA Sensor System pressure measurements, compared to standard-of-care fluid-filled catheter PA pressure measurements obtained by standard RHC
Measured: 12 months
Device Success
Percentage of device success as documented by ability of the System to successfully transmit collected PAP data to a secure database
Measured: 90 days
Change in Pulmonary Artery (PA) pressure
Change in PA pressure:
- Pre- and post-implant
- Before and after 6-Minute Walk Test
- Sitting vs supine PA pressure measurements
Measured: 90 days and 2 years
HF related hospitalizations, treatments in a hospital day-care setting, or urgent outpatient clinic visits.
Frequency of HF hospitalizations, HF treatments in a hospital day-care setting, or urgent outpatient clinic HF visits.
Measured: 90 days and 2 years
Quality of Life measured by Kansas City Cardiomyopathy Questionnaire (KCCQ)
The Quality of Life KCCQ questionnaire is a measure of health-related quality of life. It is a 23-item, self-administered instrument that quantifies physical function, symptoms (frequency, severity and recent change), social function, self-efficacy and knowledge, and quality of life related to Heart Failure. Out of 23-items, 10 scores will be calculated: Physical Limitation, Symptom Stability, Symptom Frequency, Symptom Burden, Total Symptom Score, Self-Efficacy, Quality of Life, Social Limitation, Overall Summary Score, Clinical Summary Score .Presentation will be done by means of descriptive statistics including the absolute value and change from baseline by visit.
Measured: 90 days and 2 years
Adherence to regular myCordella™ Peripherals measurements measured as a percentage of subjects who adhere to regular myCordella™ Peripherals measurements
Subjects will be instructed to perform daily measurements throughout the study. Subject compliance will be defined as at least 5 days of data collection/transmissions per week.
Measured: 90 days and 2 years
Heart Failure related medication changes
Heart failure related medication change will be collected and summarized by visit presenting the percentage of subjects with and without any change in Heart Failure related medication
Measured: 90 days and 2 years
Functional Status Change as measured by New York Heart Association (NYHA) functional classification
The NYHA functional classification categorizes the extent of heart failure by placing subjects in one of four (I, II, III, IV) categories based on how much they are limited during physical activity and symptoms of shortness of breath and/or angina. Shifts in NYHA functional classification from baseline over all post-baseline visits will be presented.
Measured: 90 days and 2 years
Functional Status Change as measured by 6-Minute Walk Test
Subjects complete a six (6) minute walk test at the study visits described in the study protocol. Total distance walked (meters) will be collected and analyzed by means of descriptive statistics including the absolute value and change from baseline by visit.
Measured: 90 days and 2 years
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted9 Jul 2019
- Study start26 Jun 2019
- Primary completion30 Oct 2021
- Study completionDec 2031 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Heart Failure NYHA Class IIIStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 81 participants (actual)
Sponsor and investigators
- Lead sponsor
- Endotronix, Inc.
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Edward Karst, Study director, Edwards Lifesciences
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04012944
- Sponsor's protocol ID
- ETX-HFS-PA-02
- Status last verified
- May 2026
- First submitted
- 12 Jun 2019
- Last updated
- 27 Jul 2026
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
Study at a glance
From the registry record, last updated by the sponsor on 27 Jul 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Prospective, Multi-Center, Open-Label, Single-Arm Clinical Trial Evaluating the Safety and Efficacy of the Cordella™ Pulmonary Artery Sensor System in New York Heart Association (NYHA) Class III Heart Failure Patients (SIRONA 2 Trial)
- ClinicalTrials.gov ID
- NCT04012944
- Acronym / sponsor ID
- ETX-HFS-PA-02
- Conditions
- Heart Failure NYHA Class III
- Keywords
- Heart Failure, Heart Diseases, Cardiovascular Disease
- Study type
- Interventional
- Recruitment status
- Active, not recruiting
- Enrolment
- 81 participants (actual)
- Lead sponsor
- Endotronix, Inc.Industry (pharma, biotech, devices)
- Study start
- 26 Jun 2019 (actual)
- Primary completion
- 30 Oct 2021 (actual)
- Study completion
- Dec 2031 (estimated)
- First posted
- 9 Jul 2019 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This is a prospective, multi-center, open-label, single-arm CE-Mark trial to assess device safety and efficacy of the Cordella PA Sensor System in up to 75 New York Heart Association (NYHA) Class III Heart Failure patients who will receive the Cordella PA Sensor Implant.
Detailed description
The study objectives are:
- To establish that the Cordella PA Sensor can be safely delivered, deployed, and remain stable within the target pulmonary artery (PA) segment through 30 days post-implant.
- To compare Cordella PA Sensor System pressure measurements with fluid-filled catheter PA pressure measurements obtained by standard right heart catheterization (RHC) at 90 days post implant.
Study design
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Cordella™ Pulmonary Artery Sensor System | Experimental | Device: Cordella™ Pulmonary Artery Sensor SystemThe Cordella PA Sensor System (CorPASS) is intended to measure, record, and transmit pulmonary artery pressure (PAP) data from NYHA Class III heart failure patients at home to clinicians for assessment and patient-centered heart failure management |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (11 listed)
- Subject has given written informed consent
- Male or female, at least 18 years of age
- Diagnosis of HF ≥ 6 months with either preserved or reduced left ventricular ejection fraction (LVEF) and NYHA Class III HF at the time of Screening
- HF related hospitalization, HF treatment in a hospital day-care setting, or unplanned outpatient clinic HF visit within 12 months prior to consent and/or increase of N-terminal pro-Brain Natriuretic Peptide (NT-proBNP) (or Brain Natriuretic Peptide (BNP)) at time of Screening defined as:
- Subjects must be receiving appropriate medical management of HF for 3 months prior to Screening and clinically stable for at least 1 month prior to study entry
Key exclusion criteria (22 listed)
- Subjects with primary pulmonary hypertension
- Subjects with an active infection at the Cordella PA Sensor Implant Visit
- Subjects with history of pulmonary embolism or deep vein thrombosis
- Subjects who have had a major cardiovascular event (e.g., myocardial infarction, stroke) within 2 months of the Screening Visit
- Subjects whereby RHC is contraindicated
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Cordella™ Pulmonary Artery Sensor SystemThe Cordella PA Sensor System comprises seven subsystems that operate together to take daily Pulmonary Artery Pressure (PAP) readings at a patient's home and transmit the results to a care provider for evaluation. 1. Cordella Sensor 2. Cordella Delivery System 3. myCordella Patient Reader 4. Reader Dock 5. Cordella Calibration Equipment (CalEQ) 6. myCordella Hub 7. Cordella Data Analysis Platform (CDAP). | Device | Cordella™ Pulmonary Artery Sensor System |
Primary outcome
Safety: Freedom from Adverse Events
Time frame: 30 days
To evaluate the primary safety endpoint: Freedom from AEs associated with use of the CorPASS through 30 days post Cordella PA Sensor implant, the number of subjects with and without any Adverse Device Events will be summarized.
Accuracy of Cordella PA Sensor System pressure measurements, compared to standard-of-care fluid-filled catheter PA pressure measurements obtained by standard Right Heart Catheterization (RHC)
Time frame: 90 days
System accuracy will be compared to the accuracy of standard-of-care commercial products that use fluid-filled invasive catheters to measure PA pressure at 90 days post implant visit.
13 secondary outcomes
Frequency of Adverse Events
Time frame: 30 days and 2 years
Device/system-related complications
Time frame: 30 days and 2 years
Pressure sensor failure rate
Time frame: 30 days and 2 years
Accuracy using the Bland Altman Method
Time frame: 90 days
Accuracy of Cordella PA Sensor pressure measurements
Time frame: 12 months
Device Success
Time frame: 90 days
Change in Pulmonary Artery (PA) pressure
Time frame: 90 days and 2 years
HF related hospitalizations, treatments in a hospital day-care setting, or urgent outpatient clinic visits.
Time frame: 90 days and 2 years
Quality of Life measured by Kansas City Cardiomyopathy Questionnaire (KCCQ)
Time frame: 90 days and 2 years
Adherence to regular myCordella™ Peripherals measurements measured as a percentage of subjects who adhere to regular myCordella™ Peripherals measurements
Time frame: 90 days and 2 years
Heart Failure related medication changes
Time frame: 90 days and 2 years
Functional Status Change as measured by New York Heart Association (NYHA) functional classification
Time frame: 90 days and 2 years
Functional Status Change as measured by 6-Minute Walk Test
Time frame: 90 days and 2 years
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 27 Jul 2026.
Related trials for Heart Failure NYHA Class III
Recruiting
PrEcision Pacing in HFpEF: the PEP-HFpEF Trial
Heart Failure and Preserved Ejection Fraction, Heart Failure New York Heart Association Class III
Active, not recruiting
Neural Cardiac Therapy for Heart Failure Study (NECTAR-HF)
Heart Failure, Congestive Heart Failure
Recruiting
Barostim-Enabled NEurohormonal Intervention For Improving Treatment of Heart Failure
Heart Failure, Heart Failure NYHA Class II
Not yet recruiting
Inspiratory Muscle Training in Hospitalized Patients With Heart Failure Awaiting Advanced Therapies
Heart Failure, Heart Failure New York Heart Association Class III
Recruiting
NORM-HF Pivotal Study
Heart Failure, NYHA Class III Heart Failure
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Edward Karst study director
Edwards Lifesciences
7 sites in 3 countries: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Cordella™ Pulmonary Artery Sensor System in people with Heart Failure NYHA Class III, run by Endotronix, Inc. at 7 sites in 3 countries.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 11 inclusion and 22 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: under way, not looking for participants, as of the sponsor's last update on 27 Jul 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 7 sites in Germany, Belgium, Ireland. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Safety: Freedom from Adverse Events (time frame: 30 days). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 27 Jul 2026.