ICDPARCADIANCT04014946
Assessment of Risk Factors for Appropriate ICD (Implantable Cardioverter-defibrillator) Intervention in Patients With Ischemic Cardiomyopathy
A study testing ICD implantation in people with ICD and Cardiomyopathy Ischemic, run by Biotronik SE & Co. KG.
Trial summary
Design: PARCADIA is a prospective non-randomized non-interventional multi-center clinical investigation in Europe. Patients with depressed LV (left ventricular) function assessed on local standards, of ischemic origin and on chronic optimal medical therapy will be selected according to inclusion and exclusion… Read more about this study
- Who is it for?
- Ages 18 to 85 years
- Conditions the study is for
- ICD, Cardiomyopathy Ischemic, Primary Prevention
- What is being tested?
- ICD implantation
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 200 participants
- Where
- No sites listed yet
- Study dates
- 24 Jul 2012to 22 Jul 2020
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 85 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Patient with ischemic cardiomyopathy indicated for a de novo ICD implantation for primary prevention, according to ESC guidelines or local standards (MADIT II population)
- Written informed consent / willingness and ability to comply with the protocol
Who cannot join
- Contraindication for MRI
- Severe renal dysfunction (stage 4 or 5) resulting in contra-indication for the admission of gadolinium during MRI (See Appendix A for more details)
- Indication for secondary prevention ICD implantation
- Class I indication for cardiac resynchronization therapy
- Heart failure with New York Heart Association functional class IV
- LV ejection fraction >40%
Show all 10Show fewer
- Age <18 years and >85 years
- Women that are pregnant, lactating or planning to become pregnant
- Participating in any other clinical trial with active intervention(s) during the course of this study
- Life expectancy less than 1 year
About this study
Official title: Prospective Assessment of Risk Factors for Appropriate ICD Intervention in Patients With Ischemic Cardiomyopathy
Design: PARCADIA is a prospective non-randomized non-interventional multi-center clinical investigation in Europe. Patients with depressed LV (left ventricular) function assessed on local standards, of ischemic origin and on chronic optimal medical therapy will be selected according to inclusion and exclusion criteria, implanted with an ICD after executing baseline investigations and prospectively followed up for minimal 24 months and until the termination of the clinical investigation.
General objective: analysis of baseline risk factors to identify predictors for appropriate ICD intervention in patients with ischemic cardiomyopathy receiving an ICD for primary prevention (MADIT II population).
Read more
Hypothesis: The primary alternative hypothesis states that the mean relative infarct transmurality (RIT) is different in patients with (RITshock or ATP (Anti Tachy Pacing)) and without (RITno shock or ATP )appropriate ICD intervention, i.e. shock or ATP.
- Null hypothesis (H0): RITshock or ATP = RITno shock or ATP
- Alternative hypothesis (Ha): RITshock or ATP ≠ RITno shock or ATP
Sample size: 200 patients.
Follow-up: Enrolment visit, pre implant screening, ICD implantation, pre-hospital discharge visit, and follow-up (FUP) visits at 2, 6, 12, 18, 24 months including home monitoring. Additional routine FUP every 6 months until study termination after last enrolled patient has completed 2 years FUP.
Read the detailed description
Rationale: Implantation of an ICD as primary prevention therapy is indicated according to the current guidelines based on the low LVEF (Left Ventricular Ejection Fraction) as it was shown to significantly reduce mortality. Although of proven efficacy, ICD therapy is associated with survival benefit in only a small fraction of patients. It is estimated that 18 patients would have to receive an ICD to save one life, resulting in a huge burden on national health systems. Moreover, only about one quarter of all guideline eligible primary prevention ICD patients receive appropriate shocks. The above considerations support the need for an effective risk-stratification method to identify patients that benefit most (or least) from this therapy. Evaluation of ventricular anatomy and function by imaging techniques has become more important since this provides information on the substrate (myocardial scar) and trigger of life-threatening ventricular arrhythmias. Besides accurate estimation of left and right ventricular volumes and functions, Late Gadolinium Enhanced Cardiac Magnetic Resonance (LGE-CMR) imaging has a very high sensitivity to detect myocardial scar. Quantification of scar characteristics by cardiac MRI might be useful for the prediction of future arrhythmic events in patients with ischemic cardiomyopathy. However evidence is conflicting and published papers are hampered by limited patient numbers and can only be regarded in the light of generating hypothesis. The PARCADIA clinical investigation will explore the potential of cardiac MRI as a predictor for appropriate ICD intervention in a multicenter setting.
PARCADIA is a prospective non-randomized non-interventional multi-center clinical investigation in Europe. Patients with depressed LV (Left Ventricular) function assessed on local standards, of ischemic (at least 40 days post-MI (myocardial infarction) or 3 months post revascularization) origin and on chronic optimal medical therapy will be selected according to inclusion and exclusion criteria, implanted with an ICD after executing baseline investigations and prospectively followed up for minimal 24 months and until the termination of the clinical investigation
General objective: analysis of baseline risk factors to identify predictors for appropriate ICD intervention in patients with ischemic cardiomyopathy receiving an ICD for primary prevention (MADIT II population).
The primary objective of the clinical investigation is to determine whether there is a relationship between appropriate ICD intervention (shock or ATP) and the Relative Infarct Transmurality (RIT) obtained from Late Gadolinium Enhanced Cardiac Magnetic Resonance (LGE-CMR) imaging in patients with ischemic cardiomyopathy, receiving an ICD for primary prevention.
Methodology: Screening: (within 6 months before enrolment) patients with LV depressed function due to Ischemic Cardiomyopathy with an indication for primary prevention ICD implantation according to ESC (European Society of Cardiology) guidelines or local standards will be screened within 6 months before enrolment.
pre implant diagnostics: within 3 months after enrolment LGE-CMR imaging, 24h holter, 12-lead ECG, will be performed and biochemical markers will be obtained.
ICD implantation: Implantation of a Lumax 540 single/dual chamber ICD or successor withiin 3 months after enrolment. The ICD will be programmed according to protocol.
Pre-hospital discharge an ICD interrogation wil be performed. Follow-up (FUP) visits at: 2, 6, 12, 18, 24 months with inclusion of standard 12-lead ECG, ICD check-up and cardiologist visit in the outpatient clinic. Additional routine FUP every 6 months until study termination after last enrolled patient has completed 2 years FUP.
- Conditions
- ICD, Cardiomyopathy Ischemic, Primary Prevention
- Being tested
- ICD implantation
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
ICD implantationDevice
Also called Lumax 540 single/dual chamber ICD or successor
implantation of the Lumax 540 single/dual chamber ICD or successor
| Study group | Role | What they receive |
|---|---|---|
| ICD implantation | Other | Implantation of a Lumax 540 single/dual chamber ICD or successor according to local practice within 3 months after enrolment. The patient will be implanted with a single or dual chamber device according to ESC guidelines. Receives: Device: ICD implantation |
What is being measured
The primary outcome is the main question the study is designed to answer.
Relative Infarct Transmurality
Percentage Relative Infarct Transmurality (RIT = transmural infarct mass / total infarct mass) obtained from LGE-CMR
Measured: Measured during Late gadolinium enhancement cardiovascular magnetic resonance (LGE-CMR) imaging within 3 months after inclusion and before ICD implantation
appropriate ICD intervention (shock or ATP)
assessment whether patient had appropriate ICD intervention (shock or ATP) or not during 24 months follow-up. ICD interventions will be labeled appropriate or non-appropriate by an independent endpoint committee.
Measured: Until the 24 month follow-up
Secondary outcomes (23)
LV function (EF)
Left Ventricular function (Ejection Fraction in %) measured during LGE-CMR at baseline before ICD implantation
Measured: Baseline
LV mass
LV mass measured during LGE-CMR at baseline before ICD implantation
Measured: Baseline
total infarct mass
total infarct mass measured during GGE-CMR at baseline before ICD implantation
Measured: Baseline
transmural infarct mass
transmural infarct mass measured during LGE-CMR at baseline before ICD implantation
Measured: Baseline
mean Heart Rate (HR)
mean HR measured by 24-hrs Holter
Measured: Baseline
Day and night HR
Day and night HR measured by 24-hrs Holter
Measured: baseline
spontaneous episodes of atrial and ventricular arrhythmias
number of spontaneous episodes of atrial and ventricular arrhythmias measured by 24-hrs Holter
Measured: baseline
heart rate variability (SDNN: Standard deviation of consecutive normal-to-normal intervals)
heart rate variability (SDNN) measured by 24-hrs Holter
Measured: baseline
HR
HR on 12 lead ECG
Measured: baseline
rhythm
rhythm on 12 lead ECG
Measured: baseline
QRS width
QRS width on 12 lead ECG
Measured: baseline
serum sodium and potassium
concentration of serum sodium and potassium (in mmol/l ) (blood sample)
Measured: baseline
serum creatinine
concentration of serum creatinine (in umol/l) (blood sample)
Measured: baseline
uric acid
concentration of uric acid (in mmol/l) (blood sample)
Measured: baseline
albumin
concentration of albumin (in g/l) (blood sample)
Measured: baseline
HbA1c (Hemoglobin A1c)
concentration HbA1c (mmol/mol) (blood sample)
Measured: baseline
NT-proBNP (N-terminal pro-hormone Brain Natriuretic Peptide)
concentration NT-proBNP (in pg/ml) (blood sample)
Measured: baseline
hsTNT/I (high sensitive Troponin-T/I)
concentration hsTNT/I (in ng/ml) (blood sample)
Measured: baseline
aldosterone
concentration aldosterone (in pmol/l) (blood sample)
Measured: baseline
incidence of hypertension
Baseline clinical demographics: hypertension in clinical history
Measured: baseline
incidence of diabetes
Baseline clinical demographics: diabetes in clinical history
Measured: baseline
incidence of hypercholesterolemia
Baseline clinical demographics: hypercholesterolemia in clinical history
Measured: baseline
PVC/hr: Premature ventricular contraction per hour
PVC/hr: Premature ventricular contraction per hour on 24hrs Holter
Measured: baseline
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted10 Jul 2019
- Study start24 Jul 2012
- Primary completion28 May 2020
- Study completion22 Jul 2020
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for ICDStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Prevention
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- The study model is single group. At the analysis the patients will be divided in two groups bij outcome of ICD therapy/no ICD therapy. The endpoints related to the primary hypothesis are appropriate ICD intervention (shock or ATP) and Relative Infarct Transmurality (RIT = transmural infarct mass / total infarct mass) obtained from LGE-CMR. ICD interventions will be labeled appropriate or non-appropriate by an independent endpoint committee. * RITshock or ATP: RIT expectation value in patients with ≥1 appropriate shock or ATP therapy until the 24mo follow-up * RIT no shock or ATP: RIT expectation value in patients without any appropriate shock or ATP therapy until the 24mo follow-up
- Masking
- None (open label)
- Enrolment
- 200 participants (actual)
Sponsor and investigators
- Lead sponsor
- Biotronik SE & Co. KG
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04014946
- Sponsor's protocol ID
- TA97
- Acronym
- PARCADIA
- Status last verified
- Sep 2020
- First submitted
- 10 May 2019
- Last updated
- 29 Sep 2020
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 29 Sep 2020. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Prospective Assessment of Risk Factors for Appropriate ICD Intervention in Patients With Ischemic Cardiomyopathy
- ClinicalTrials.gov ID
- NCT04014946
- Acronym / sponsor ID
- PARCADIA / TA97
- Conditions
- ICD, Cardiomyopathy Ischemic, Primary Prevention
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 200 participants (actual)
- Lead sponsor
- Biotronik SE & Co. KGIndustry (pharma, biotech, devices)
- Study start
- 24 Jul 2012 (actual)
- Primary completion
- 28 May 2020 (actual)
- Study completion
- 22 Jul 2020 (actual)
- First posted
- 10 Jul 2019 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Design: PARCADIA is a prospective non-randomized non-interventional multi-center clinical investigation in Europe. Patients with depressed LV (left ventricular) function assessed on local standards, of ischemic origin and on chronic optimal medical therapy will be selected according to inclusion and exclusion criteria, implanted with an ICD after executing baseline investigations and prospectively followed up for minimal 24 months and until the termination of the clinical investigation.
General objective: analysis of baseline risk factors to identify predictors for appropriate ICD intervention in patients with ischemic cardiomyopathy receiving an ICD for primary prevention (MADIT II population).
Hypothesis: The primary alternative hypothesis states that the mean relative infarct transmurality (RIT) is different in patients with (RITshock or ATP (Anti Tachy Pacing)) and without (RITno shock or ATP )appropriate ICD intervention, i.e. shock or ATP.
- Null hypothesis (H0): RITshock or ATP = RITno shock or ATP
- Alternative hypothesis (Ha): RITshock or ATP ≠ RITno shock or ATP
Sample size: 200 patients.
Follow-up: Enrolment visit, pre implant screening, ICD implantation, pre-hospital discharge visit, and follow-up (FUP) visits at 2, 6, 12, 18, 24 months including home monitoring. Additional routine FUP every 6 months until study termination after last enrolled patient has completed 2 years FUP.
Detailed description
Rationale: Implantation of an ICD as primary prevention therapy is indicated according to the current guidelines based on the low LVEF (Left Ventricular Ejection Fraction) as it was shown to significantly reduce mortality. Although of proven efficacy, ICD therapy is associated with survival benefit in only a small fraction of patients. It is estimated that 18 patients would have to receive an ICD to save one life, resulting in a huge burden on national health systems. Moreover, only about one quarter of all guideline eligible primary prevention ICD patients receive appropriate shocks. The above considerations support the need for an effective risk-stratification method to identify patients that benefit most (or least) from this therapy. Evaluation of ventricular anatomy and function by imaging techniques has become more important since this provides information on the substrate (myocardial scar) and trigger of life-threatening ventricular arrhythmias. Besides accurate estimation of left and right ventricular volumes and functions, Late Gadolinium Enhanced Cardiac Magnetic Resonance (LGE-CMR) imaging has a very high sensitivity to detect myocardial scar. Quantification of scar characteristics by cardiac MRI might be useful for the prediction of future arrhythmic events in patients with ischemic cardiomyopathy. However evidence is conflicting and published papers are hampered by limited patient numbers and can only be regarded in the light of generating hypothesis. The PARCADIA clinical investigation will explore the potential of cardiac MRI as a predictor for appropriate ICD intervention in a multicenter setting.
PARCADIA is a prospective non-randomized non-interventional multi-center clinical investigation in Europe. Patients with depressed LV (Left Ventricular) function assessed on local standards, of ischemic (at least 40 days post-MI (myocardial infarction) or 3 months post revascularization) origin and on chronic optimal medical therapy will be selected according to inclusion and exclusion criteria, implanted with an ICD after executing baseline investigations and prospectively followed up for minimal 24 months and until the termination of the clinical investigation
General objective: analysis of baseline risk factors to identify predictors for appropriate ICD intervention in patients with ischemic cardiomyopathy receiving an ICD for primary prevention (MADIT II population).
The primary objective of the clinical investigation is to determine whether there is a relationship between appropriate ICD intervention (shock or ATP) and the Relative Infarct Transmurality (RIT) obtained from Late Gadolinium Enhanced Cardiac Magnetic Resonance (LGE-CMR) imaging in patients with ischemic cardiomyopathy, receiving an ICD for primary prevention.
Methodology: Screening: (within 6 months before enrolment) patients with LV depressed function due to Ischemic Cardiomyopathy with an indication for primary prevention ICD implantation according to ESC (European Society of Cardiology) guidelines or local standards will be screened within 6 months before enrolment.
pre implant diagnostics: within 3 months after enrolment LGE-CMR imaging, 24h holter, 12-lead ECG, will be performed and biochemical markers will be obtained.
ICD implantation: Implantation of a Lumax 540 single/dual chamber ICD or successor withiin 3 months after enrolment. The ICD will be programmed according to protocol.
Pre-hospital discharge an ICD interrogation wil be performed. Follow-up (FUP) visits at: 2, 6, 12, 18, 24 months with inclusion of standard 12-lead ECG, ICD check-up and cardiologist visit in the outpatient clinic. Additional routine FUP every 6 months until study termination after last enrolled patient has completed 2 years FUP.
Study design
- Primary purpose
- Prevention
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- The study model is single group. At the analysis the patients will be divided in two groups bij outcome of ICD therapy/no ICD therapy. The endpoints related to the primary hypothesis are appropriate ICD intervention (shock or ATP) and Relative Infarct Transmurality (RIT = transmural infarct mass / total infarct mass) obtained from LGE-CMR. ICD interventions will be labeled appropriate or non-appropriate by an independent endpoint committee. * RITshock or ATP: RIT expectation value in patients with ≥1 appropriate shock or ATP therapy until the 24mo follow-up * RIT no shock or ATP: RIT expectation value in patients without any appropriate shock or ATP therapy until the 24mo follow-up
| Arm | Type | Receives |
|---|---|---|
| ICD implantation | Other | Device: ICD implantationImplantation of a Lumax 540 single/dual chamber ICD or successor according to local practice within 3 months after enrolment. The patient will be implanted with a single or dual chamber device according to ESC guidelines. |
Who may qualify
- Ages
- 18 to 85 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (2 listed)
- Patient with ischemic cardiomyopathy indicated for a de novo ICD implantation for primary prevention, according to ESC guidelines or local standards (MADIT II population)
- Written informed consent / willingness and ability to comply with the protocol
Key exclusion criteria (10 listed)
- Contraindication for MRI
- Severe renal dysfunction (stage 4 or 5) resulting in contra-indication for the admission of gadolinium during MRI (See Appendix A for more details)
- Indication for secondary prevention ICD implantation
- Class I indication for cardiac resynchronization therapy
- Heart failure with New York Heart Association functional class IV
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| ICD implantationAlso: Lumax 540 single/dual chamber ICD or successorimplantation of the Lumax 540 single/dual chamber ICD or successor | Device | ICD implantation |
Primary outcome
Relative Infarct Transmurality
Time frame: Measured during Late gadolinium enhancement cardiovascular magnetic resonance (LGE-CMR) imaging within 3 months after inclusion and before ICD implantation
Percentage Relative Infarct Transmurality (RIT = transmural infarct mass / total infarct mass) obtained from LGE-CMR
appropriate ICD intervention (shock or ATP)
Time frame: Until the 24 month follow-up
assessment whether patient had appropriate ICD intervention (shock or ATP) or not during 24 months follow-up. ICD interventions will be labeled appropriate or non-appropriate by an independent endpoint committee.
23 secondary outcomes
LV function (EF)
Time frame: Baseline
LV mass
Time frame: Baseline
total infarct mass
Time frame: Baseline
transmural infarct mass
Time frame: Baseline
mean Heart Rate (HR)
Time frame: Baseline
Day and night HR
Time frame: baseline
spontaneous episodes of atrial and ventricular arrhythmias
Time frame: baseline
heart rate variability (SDNN: Standard deviation of consecutive normal-to-normal intervals)
Time frame: baseline
HR
Time frame: baseline
rhythm
Time frame: baseline
QRS width
Time frame: baseline
serum sodium and potassium
Time frame: baseline
serum creatinine
Time frame: baseline
uric acid
Time frame: baseline
albumin
Time frame: baseline
HbA1c (Hemoglobin A1c)
Time frame: baseline
NT-proBNP (N-terminal pro-hormone Brain Natriuretic Peptide)
Time frame: baseline
hsTNT/I (high sensitive Troponin-T/I)
Time frame: baseline
aldosterone
Time frame: baseline
incidence of hypertension
Time frame: baseline
incidence of diabetes
Time frame: baseline
incidence of hypercholesterolemia
Time frame: baseline
PVC/hr: Premature ventricular contraction per hour
Time frame: baseline
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 29 Sep 2020.
- Individual participant dataSharing planned: No
Related trials for ICD
Active, not recruiting
Assessment of Combined CCM and ICD Device in HFrEF
Heart Failure, Heart Failure With Reduced Ejection Fraction
RecruitingObservational study
Product Performance Report: Evaluate Long-term Reliability & Performance of Medtronic Marketed Cardiac Therapy Products
Arrhythmia, Bradycardia
Recruiting
Evaluating a Digital Aid to Improve ICD Decisions
Shared Decision-making
Active, not recruitingObservational study
TRAjectories and CLinical ExpeRiences of ICD Therapy Study
Implantable Defibrillator User
Recruiting
Danish Pragmatic Randomized Trial to Evaluate the Effect of HeartLogic-Guided Management on Heart Failure Outcomes
Heart Failure
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
Questions about this trial
What is this clinical trial studying?
A study testing ICD implantation in people with ICD and Cardiomyopathy Ischemic, run by Biotronik SE & Co. KG.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 10 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 29 Sep 2020. Status can change between updates, so confirm with the study contact before making plans.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Relative Infarct Transmurality (time frame: Measured during Late gadolinium enhancement cardiovascular magnetic resonance (LGE-CMR) imaging within 3 months after inclusion and before ICD implantation). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 Sep 2020.