Within and Between-rater Reproducibility and Validity of a Novel Portable Laser Height Meter

An observational study of Body Height and Lasers, run by Aalborg University Hospital at 1 site in Denmark.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Height may be used to calculate body mass index and reference interval for normal lung function, together with serving as an indicator for possible vertebral fractures in osteoporosis and growth retardation in children. Height is typically measured using the "gold standard" a fixed stadiometer in a clinical setting. Read more about this study

Who is it for?
Ages 18 years and olderHealthy volunteers can take part
Conditions the study is for
Body Height, Lasers, Reproducibility of Results
How many people
32 participants
Where
1 siteDenmark
Study dates
26 Aug 2019to 28 Aug 2019
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Study population: We expect to enrol approximately 30 adults, 18+ years old men and women in the study. Participants will be recruited through convenience sampling in order to maximise recruitment efforts during the time of the study.

Who may be able to join

  • Age 18 years or older.

Who cannot join

  • None

Trial locations and contacts

1 site in 1 country.

Denmark1 site
  • Aalborg University Hospital

    Aalborg, 9000

Other trials in Denmark

About this study

Height may be used to calculate body mass index and reference interval for normal lung function, together with serving as an indicator for possible vertebral fractures in osteoporosis and growth retardation in children. Height is typically measured using the "gold standard" a fixed stadiometer in a clinical setting. However, newer studies have investigated alternative ways of measuring height using portable measuring devices with laser distance metres. The advantage with this type of measure is the ability to potentially perform reliable measure in settings outside clinical controlled settings. Recently, a measuring device which required adjustments of measuring axes by hand was developed, which resulted in a measurement error of 0.35 cm compared with 0.20-0.30 cm in fixed stadiometers. In order to optimise this, it was suggested that future measuring devices using laser distance meters should be fixed in one or more measurement axes. Thus, a novel portable height device, which is fixated in two axes using a laser distance metre has been developed.

Read the detailed description

Objectives:

Primary objective: To investigate inter- and intra-rater reproducibility of the portable height device

Secondary objectives:To assess agreement between the portable height device and wall-fixed digital stadiometer.

____

Participants: Approximately 30 adults, 18+ years old men and women in the study is expected to be enrolled. Participants will be recruited through convenience sampling in order to maximise recruitment efforts during the time of the study. Data on gender, age, and height will be collected.

____

Ethics: Written informed consent will be obtained from all participants prior to the study. The local ethics committee will be consulted for approval of the study. Approval will also be obtained from the Danish Data Protection Agency.

____

Measuring devices:

Portable laser measuring device: A laser distance meter (Bosch Zamo, Robert Bosch GmbH, Gerlingen-Schillerhöhe, Germany) will be mounted perpendicularly to the end of a wooden lath (3x4x50 cm). The other end of the lath will be mounted perpendicular to a T-shaped metal plate which will fixate the x- and z-axis of the laser measuring device. The portable height device will measure vertically down in its z-axis from the participant's vertex to the floor in front of the participant.

Stadiometer (reference standard): a fixed stadiometer will be used as a reference (Harpenden Stadiometer, Holtain Limited, Crosswell, UK).

____

Procedure:

Measurements will be performed at Aalborg University Hospital, Aalborg, Denmark. Two raters will independently perform height measurements in two separate rooms with each measuring device (portable height device and fixed stadiometer) on all participants. Each rater will perform three measures per device. During measurements, participants will be asked to stand flat on the floor (hard surface) without shoes. Furthermore, participants will be asked to stand with their heels positioned together and against the wall during both type of measurements. Each rater will make sure that participants' heads are be positioned in the Frankfurt plane, and encourage participants to stand with a straight back against the wall.

Stadiometer (reference standard): The measuring device will be pulled down to the skull. Afterwards, the participant will be asked to take a deep breath and hold it, after which the measurement will be performed.

Portable laser measuring device: The lath with the laser distance meter will be placed on top of the participant's vertex and fixated in two axes by holding the T-shaped piece against the wall. The lath will be rotated until the laser distance meter points vertically, which is done using a bubble level mounted on the end of the lath. The laser distance meter will be activated by clicking on the "START" button. Participants are asked to take a deep breath and hold it, after which the measurement will be locked and recorded. Following each measurement, the participant will take a step away from the measuring area and afterwards step back again to replicate the measurement procedure.

Blinding: All 30 participants will be measured using the laser distance meter first by each rater. When this stage is complete, measurements will be secured and inaccessible, in order to blind the raters when performing stadiometer measurements afterwards. It is assumed that each rater will not be able to remember each participants' height when 30 participants are measured consecutively. After the stadiometer measurements have been performed, data will also be secured and inaccessible. Afterwards, this entire procedure will be repeated once more. Measurements will be collected using a data capturing tool Research electronic data capture (REDCap).

____

Statistics:

Participants: Age will be reported in mean with standard deviations, and gender will be reported in proportions. Both height measures will have 95% confidence intervals reported.

Agreement:Mean of all three measurements per rater per measuring device per participants will be calculated. The difference between the means will be calculated by subtracting the mean laser measurement from the mean stadiometer measurement. This will also be performed with only the mean of the two first measurements, and finally also the first measurement. Thus, it would be possible to evaluate whether one measurement would have similar agreement with two or three measurements. Bland Altman plots with limits of agreement (LOA) will be generated together with standard error of measurements (SEM) and coefficient of variation (c.v) for all the above-mentioned combinations.

Reliability: Intraclass Correlation Coefficients (ICC) with 95% confidence intervals between measuring devices will be calculated.

Software: Statistics will be performed using Microsoft Excel for Mac version 16.28 (Microsoft Office, Microsoft Corporation, WA) and IBM SPSS Statistics for MacOS version 25.0 (IBM Corporation, Armonk, NY).

____

Conflicts of interest: The authors report no conflicts of interest.

____

Dissemination: This study is planned to be published in an English-language journal. The reporting of the study will follow the current guidelines for reliability and agreement studies (GRRAS).

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Reliability

    Inter- and intra-rater reproducibility of the portable height device

    Measured: At baseline

Secondary outcomes (1)
  1. Agreement

    Agreement between the portable height device and wall-fixed digital stadiometer

    Measured: At baseline

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted28 Aug 2019
  2. Study start26 Aug 2019
  3. Primary completion28 Aug 2019
  4. Study completion28 Aug 2019

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Other
Time perspective
Cross-sectional
Enrolment
32 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04070638
Sponsor's protocol ID
2019-100
Status last verified
Oct 2019
First submitted
22 Aug 2019
Last updated
4 Oct 2019
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided: Data will be available upon reasonable request.

Publications

  • Deurenberg P, Weststrate JA, Seidell JC. Body mass index as a measure of body fatness: age- and sex-specific prediction formulas. Br J Nutr. 1991 Mar;65(2):105-14. doi: 10.1079/bjn19910073.

    PubMed 2043597
  • Renstrom SB, Andersen CS, Pedersen CH, Madsen FF. Correct measurement of height is important when assessing lung function values. Dan Med J. 2012 Feb;59(2):A4376.

    PubMed 22293049
  • Siminoski K, Warshawski RS, Jen H, Lee K. The accuracy of historical height loss for the detection of vertebral fractures in postmenopausal women. Osteoporos Int. 2006 Feb;17(2):290-6. doi: 10.1007/s00198-005-2017-y. Epub 2005 Sep 6.

    PubMed 16143833
  • Duggan MB. Anthropometry as a tool for measuring malnutrition: impact of the new WHO growth standards and reference. Ann Trop Paediatr. 2010;30(1):1-17. doi: 10.1179/146532810X12637745451834.

    PubMed 20196929
  • Voss LD, Bailey BJ, Cumming K, Wilkin TJ, Betts PR. The reliability of height measurement (the Wessex Growth Study). Arch Dis Child. 1990 Dec;65(12):1340-4. doi: 10.1136/adc.65.12.1340.

    PubMed 2270942
  • Mayol-Kreiser SN, Garcia-Turner VM, Johnston CS. Examining the utility of a laser device for measuring height in free-living adults and children. Nutr J. 2015 Sep 8;14:93. doi: 10.1186/s12937-015-0082-4.

    PubMed 26350125
  • Bauman A, Ernst K, Hayden M, Roe DJ, Murray R, Agawo M, Munga S, Schmahl E, Taren D. Assessing Community Health: An Innovative Tool for Measuring Height and Length. J Trop Pediatr. 2018 Apr 1;64(2):146-150. doi: 10.1093/tropej/fmx046.

    PubMed 28673047
  • Harris PA, Taylor R, Thielke R, Payne J, Gonzalez N, Conde JG. Research electronic data capture (REDCap)--a metadata-driven methodology and workflow process for providing translational research informatics support. J Biomed Inform. 2009 Apr;42(2):377-81. doi: 10.1016/j.jbi.2008.08.010. Epub 2008 Sep 30.

    PubMed 18929686
  • Kottner J, Audige L, Brorson S, Donner A, Gajewski BJ, Hrobjartsson A, Roberts C, Shoukri M, Streiner DL. Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed. Int J Nurs Stud. 2011 Jun;48(6):661-71. doi: 10.1016/j.ijnurstu.2011.01.016. Epub 2011 Apr 23.

    PubMed 21514934

Questions about this trial

What is this clinical trial studying?

An observational study of Body Height and Lasers, run by Aalborg University Hospital at 1 site in Denmark.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 4 Oct 2019. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Denmark. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Reliability (time frame: At baseline). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04070638, which also lists 9 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 4 Oct 2019.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in