VitrectomyNCT04076072
Beveled-Tip Versus(vs) Standard-Tip Vitrectomy Probe
A study testing Utravit High-Speed 10000 cpm Beveled Probe and standard vitrector probe- Alcon (non-beveled) Ultravit 7500 cpm in people with Vitrectomy, run by Vanderbilt University Medical Center at 1 site in United States.
Trial summary
The purpose of this study is to compare the efficiency of the new Utravit High-Speed 10000 cpm Beveled Probe to the current standard vitrector probe- Alcon (non-beveled) Ultravit 7500 cpm. Read more about this study
- Who is it for?
- Ages 18 years and olderHealthy volunteers can take part
- Conditions the study is for
- Vitrectomy
- What is being tested?
- Utravit High-Speed 10000 cpm Beveled Probe and standard vitrector probe- Alcon (non-beveled) Ultravit 7500 cpm
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 40 participants
- Where
- 1 siteUnited States
- Study dates
- 1 Sep 2019to 1 Jan 2022
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- The study population will be male and female patients 18 years old or older with the presence of pathology requiring routine vitreoretinal surgery (vitreous opacities, vitreous hemorrhage, vitreomacular traction, macular hole, epiretinal membrane) without previous history of vitreoretinal surgery. Ability to consent to procedure.
Who cannot join
- Previous incisional intraocular surgery other than uncomplicated cataract surgery with intraocular lens placement
- Inability to consent for procedure
Trial locations and contacts
1 site in 1 country.
United States1 site
Vanderbilt University Medical Center
Nashville, Tennessee, 37232
About this study
Official title: High-speed Beveled Tip Versus Standard Tip Vitrectomy Probe: a Prospective Randomized Clinical Trial
The purpose of this study is to compare the efficiency of the new Utravit High-Speed 10000 cpm Beveled Probe to the current standard vitrector probe- Alcon (non-beveled) Ultravit 7500 cpm.
Study Design:
This is a randomized controlled trial comparing the efficiency of the Ultravit High-Speed Beveled Probe with the current Alcon vitrector probe in a cohort of patients undergoing routine vitrectomy surgery.
Hypothesis:
The Advanced Ultravit high-speed beveled probe will show non-inferiority to the standard, Alcon (non-beveled) Ultravit 7500 cpm with regards to time to completion of vitrectomy and surgical outcomes.
Read the detailed description
High-speed beveled tip versus standard tip vitrectomy probe: a prospective randomized clinical trial
Background:
The Advanced Ultravit High-Speed Beveled Probe (Alcon) has a beveled-tip design that allows the cutting port to come closer to the retina compared to the previous vitrectr probe design. This allows the surgeon to maneuver in tight tissue planes and increases the functionality of the vitrector probe. This in combination with the increased cut rate of 10,000 independent cuts per minute reduces traction on the retina and increases efficiency of vitreous removal.
Purpose:
The purpose of this study is to compare the efficiency of the new Utravit High-Speed 10000 cpm Beveled Probe to the current standard vitrector probe- Alcon (non-beveled) Ultravit 7500 cpm.
Study Design:
This is a prospective, randomized controlled trial comparing the efficiency of the Advanced Ultravit High-Speed Beveled Probe with the current Alcon vitrector probe in a cohort of patients undergoing routine vitrectomy surgery.
Primary objectives:
-Intraoperative efficiency of vitrectomy surgery regarding time to completion of core vitrectomy and shave of vitreous base
Exploratory Objective:
-Intraoperative complications (e.g. iatrogenic retinal breaks, intraocular bleeding, retinal detachment)
Postoperative complications:
The study will not be sufficiently powered to assess safety. Surgeons will want to make sure there is no significant increase in complications with a different probe. However, any post operative complications would merely be an association, without any causality attributed.
Primary Endpoint:
A clinically significant difference in time to completion of core vitrectomy and shave of vitreous base between the two groups with 80% power at a 95% confidence interval.
A p-value of less than 0.05 will be deemed as statistically significant.
Sample Size Calculation Target: 40 participants (20 in each cohort) Assuming an average core vitrectomy time of 12 +/- 3 minutes, a sample size of at least 32 is needed to adequately assess for a clinically significant difference between the two groups with 80% power at a 95% confidence interval. A p-value of less than 0.05 will be deemed as statistically significant.
Procedures and Assessments:
All patients will undergo baseline testing in the study eye including:
- Best corrected Visual Acuity (BCVA)
- intraocular pressure (IOP)
- slit-lamp examination
- 360 degree indirect ophthalmoscopy
Enrollment Period:
9 months
Study Duration:
12 months
Methods:
On the day of surgery, patients will be randomized to the Ultravit High-Speed Beveled Probe or the current non-beveled Alcon Probe. All patients will undergo routine vitrectomy surgery as scheduled; patients will be masked to the vitrector probe used. Time to completion of vitrectomy and time to completion of vitreous base shave will be recorded by a masked timer.
All examination will be repeated as regularly scheduled postoperative visits by a masked reader.
Safety will be assessed at each visit by evaluation for any adverse events.
Randomization:
Randomization and data storage will occur in RedCap. Patients will be randomized the day of surgery. The randomization numbers will be generated using the following procedure to ensure that treatment assignment is unbiased and concealed from patients and investigator staff. A patient randomization list will be produced by the IRT provider using a validated system that automates the random assignment of patient numbers to randomization numbers. These randomization numbers are linked to the different treatment arms. The randomization scheme for patients will be reviewed and approved by a member of the Randomization Group.
Data collection measures:
- Unique Patient identifier
- Vision
- IOP
- Oculus sinister (Left Eye) /Ocular Dexter (Right Eye)
- Surgical Indication
- Time to completion of vitrectomy
- Time to completion of vitreous base shave
- Slit-lamp abnormalities
- Dilated Fundus Exam (DFE) abnormalities
- Post operation complications
- Data collection April 2019 to Dec 2019
- Data Analysis Jan 2020
Adverse Events:
Reporting of Adverse Events, Serious Adverse Events, and Unanticipated Problems Involving Risk to Participants or Others will be reported to the Institutional Review Board (IRB) pursuant to their policy as outlined under the VANDERBILT HUMAN RESEARCH PROTECTIONS PROGRAM Policy III.L.
Safety:
Risk Minimization:
The study will be conducted in accordance with the International Conference on Harmonization (ICH) along with the Good Clinical Practices (GCP) guidelines and all applicable local and U.S. federal regulatory requirements.
Prior to entry into the study or initiation of any study related procedures, the subject or legal representative must read, sign, and date the current institutional review board-approved version of the informed consent form. Fully informed consent or verbal consent must be obtained from the subject or legal representative in accordance with local legal requirements and IRB requirements.
Only potential subjects who meet the inclusion/exclusion criteria will be enrolled in to this protocol. The Principal Investigator will oversee all study procedures to ensure subject safety and protocol compliance.
Risk v. Benefits:
The prospective subject will be carefully screened to ensure inclusion/exclusion criteria are met.
There may be no direct benefit to the subjects ;however, the knowledge gained from this study may lead to improved methods of diagnosing, staging and managing Vitrectomy surgery in the future.
There will be no specific ethnic or age group targeted or excluded.
- Conditions
- Vitrectomy
- Being tested
- Utravit High-Speed 10000 cpm Beveled Probe, standard vitrector probe- Alcon (non-beveled) Ultravit 7500 cpm
- Keywords
- vitrectomy
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Utravit High-Speed 10000 cpm Beveled ProbeDevice
This is a randomized controlled trial comparing the Ultravit High-Speed Beveled Probe with the current Alcon vitrector probe in a cohort of patients undergoing routine vitrectomy surgery.
standard vitrector probe- Alcon (non-beveled) Ultravit 7500 cpmDevice
This is a randomized controlled trial comparing the Ultravit High-Speed Beveled Probe with the current Alcon vitrector probe in a cohort of patients undergoing routine vitrectomy surgery.
| Study group | Role | What they receive |
|---|---|---|
| Alcon Advanced Ultravit High-Speed Vitrectomy Probe | Active comparator | On the day of surgery, patients will be randomized to the Ultravit High-Speed Beveled Probe or the current non-beveled Alcon Probe. All patients will undergo routine vitrectomy surgery as scheduled; patients will be unaware of the vitrector probe used. Time to completion of vitrectomy and time to completion of vitreous base shave will be recorded by study staff unaware of the vitrector probe used. All examination will be repeated as regularly scheduled postoperative visits by a reader unaware of which probe was used. Safety will be assessed at each visit by evaluation for any adverse events. Receives: Device: Utravit High-Speed 10000 cpm Beveled Probe |
| Alcon Non-Beveled Tip Vitrectomy Probe | Active comparator | On the day of surgery, patients will be randomized to the Ultravit High-Speed Beveled Probe or the current non-beveled Alcon Probe. All patients will undergo routine vitrectomy surgery as scheduled; patients will be unaware of the vitrector probe used. Time to completion of vitrectomy and time to completion of vitreous base shave will be recorded by study staff unaware of the vitrector probe used. All examination will be repeated as regularly scheduled postoperative visits by a reader unaware of which probe was used. Safety will be assessed at each visit by evaluation for any adverse events. Receives: Device: standard vitrector probe- Alcon (non-beveled) Ultravit 7500 cpm |
What is being measured
The primary outcome is the main question the study is designed to answer.
Time to Completion of Core Vitrectomy and Shave of Vitreous Base
Intraoperative efficiency of vitrectomy surgery regarding time to completion of core vitrectomy and shave of vitreous base
Measured: Time to completion of core vitrectomy and shave of vitreous base (12 ± 3 minutes )
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted3 Sep 2019
- Study start1 Sep 2019
- Primary completion1 Jan 2022
- Study completion1 Jan 2022
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for VitrectomyStudies of the same condition, open and under way.
- More trials run by Vanderbilt University Medical CenterThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Health services research
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Model description
- This is a randomized controlled trial comparing the Ultravit High-Speed Beveled Probe with the current Alcon vitrector probe in a cohort of patients undergoing routine vitrectomy surgery.
- Masking
- Triple blind
- Who is masked
- Participant, Care provider, Investigator
- Enrolment
- 40 participants (actual)
Sponsor and investigators
- Lead sponsor
- Vanderbilt University Medical Center
- Sponsor type
- University, hospital or other
- Collaborators
- Alcon Research
- Responsible party
- Principal investigator, Shriji Patel, Vanderbilt University Medical Center
- Investigators
- Shriji N Patel, MD, Principal investigator, Vanderbilt Eye Institute
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04076072
- Sponsor's protocol ID
- 190728
- Status last verified
- Sep 2022
- First submitted
- 29 Aug 2019
- Last updated
- 21 Oct 2022
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 21 Oct 2022. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- High-speed Beveled Tip Versus Standard Tip Vitrectomy Probe: a Prospective Randomized Clinical Trial
- ClinicalTrials.gov ID
- NCT04076072
- Acronym / sponsor ID
- 190728
- Conditions
- Vitrectomy
- Keywords
- vitrectomy
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 40 participants (actual)
- Lead sponsor
- Vanderbilt University Medical CenterUniversity, hospital or other
- Collaborators
- Alcon Research
- Study start
- 1 Sep 2019 (actual)
- Primary completion
- 1 Jan 2022 (actual)
- Study completion
- 1 Jan 2022 (actual)
- First posted
- 3 Sep 2019 (actual)
- Results
- Posted 21 Oct 2022
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of this study is to compare the efficiency of the new Utravit High-Speed 10000 cpm Beveled Probe to the current standard vitrector probe- Alcon (non-beveled) Ultravit 7500 cpm.
Study Design:
This is a randomized controlled trial comparing the efficiency of the Ultravit High-Speed Beveled Probe with the current Alcon vitrector probe in a cohort of patients undergoing routine vitrectomy surgery.
Hypothesis:
The Advanced Ultravit high-speed beveled probe will show non-inferiority to the standard, Alcon (non-beveled) Ultravit 7500 cpm with regards to time to completion of vitrectomy and surgical outcomes.
Detailed description
High-speed beveled tip versus standard tip vitrectomy probe: a prospective randomized clinical trial
Background:
The Advanced Ultravit High-Speed Beveled Probe (Alcon) has a beveled-tip design that allows the cutting port to come closer to the retina compared to the previous vitrectr probe design. This allows the surgeon to maneuver in tight tissue planes and increases the functionality of the vitrector probe. This in combination with the increased cut rate of 10,000 independent cuts per minute reduces traction on the retina and increases efficiency of vitreous removal.
Purpose:
The purpose of this study is to compare the efficiency of the new Utravit High-Speed 10000 cpm Beveled Probe to the current standard vitrector probe- Alcon (non-beveled) Ultravit 7500 cpm.
Study Design:
This is a prospective, randomized controlled trial comparing the efficiency of the Advanced Ultravit High-Speed Beveled Probe with the current Alcon vitrector probe in a cohort of patients undergoing routine vitrectomy surgery.
Primary objectives:
-Intraoperative efficiency of vitrectomy surgery regarding time to completion of core vitrectomy and shave of vitreous base
Exploratory Objective:
-Intraoperative complications (e.g. iatrogenic retinal breaks, intraocular bleeding, retinal detachment)
Postoperative complications:
The study will not be sufficiently powered to assess safety. Surgeons will want to make sure there is no significant increase in complications with a different probe. However, any post operative complications would merely be an association, without any causality attributed.
Primary Endpoint:
A clinically significant difference in time to completion of core vitrectomy and shave of vitreous base between the two groups with 80% power at a 95% confidence interval.
A p-value of less than 0.05 will be deemed as statistically significant.
Sample Size Calculation Target: 40 participants (20 in each cohort) Assuming an average core vitrectomy time of 12 +/- 3 minutes, a sample size of at least 32 is needed to adequately assess for a clinically significant difference between the two groups with 80% power at a 95% confidence interval. A p-value of less than 0.05 will be deemed as statistically significant.
Procedures and Assessments:
All patients will undergo baseline testing in the study eye including:
- Best corrected Visual Acuity (BCVA)
- intraocular pressure (IOP)
- slit-lamp examination
- 360 degree indirect ophthalmoscopy
Enrollment Period:
9 months
Study Duration:
12 months
Methods:
On the day of surgery, patients will be randomized to the Ultravit High-Speed Beveled Probe or the current non-beveled Alcon Probe. All patients will undergo routine vitrectomy surgery as scheduled; patients will be masked to the vitrector probe used. Time to completion of vitrectomy and time to completion of vitreous base shave will be recorded by a masked timer.
All examination will be repeated as regularly scheduled postoperative visits by a masked reader.
Safety will be assessed at each visit by evaluation for any adverse events.
Randomization:
Randomization and data storage will occur in RedCap. Patients will be randomized the day of surgery. The randomization numbers will be generated using the following procedure to ensure that treatment assignment is unbiased and concealed from patients and investigator staff. A patient randomization list will be produced by the IRT provider using a validated system that automates the random assignment of patient numbers to randomization numbers. These randomization numbers are linked to the different treatment arms. The randomization scheme for patients will be reviewed and approved by a member of the Randomization Group.
Data collection measures:
- Unique Patient identifier
- Vision
- IOP
- Oculus sinister (Left Eye) /Ocular Dexter (Right Eye)
- Surgical Indication
- Time to completion of vitrectomy
- Time to completion of vitreous base shave
- Slit-lamp abnormalities
- Dilated Fundus Exam (DFE) abnormalities
- Post operation complications
- Data collection April 2019 to Dec 2019
- Data Analysis Jan 2020
Adverse Events:
Reporting of Adverse Events, Serious Adverse Events, and Unanticipated Problems Involving Risk to Participants or Others will be reported to the Institutional Review Board (IRB) pursuant to their policy as outlined under the VANDERBILT HUMAN RESEARCH PROTECTIONS PROGRAM Policy III.L.
Safety:
Risk Minimization:
The study will be conducted in accordance with the International Conference on Harmonization (ICH) along with the Good Clinical Practices (GCP) guidelines and all applicable local and U.S. federal regulatory requirements.
Prior to entry into the study or initiation of any study related procedures, the subject or legal representative must read, sign, and date the current institutional review board-approved version of the informed consent form. Fully informed consent or verbal consent must be obtained from the subject or legal representative in accordance with local legal requirements and IRB requirements.
Only potential subjects who meet the inclusion/exclusion criteria will be enrolled in to this protocol. The Principal Investigator will oversee all study procedures to ensure subject safety and protocol compliance.
Risk v. Benefits:
The prospective subject will be carefully screened to ensure inclusion/exclusion criteria are met.
There may be no direct benefit to the subjects ;however, the knowledge gained from this study may lead to improved methods of diagnosing, staging and managing Vitrectomy surgery in the future.
There will be no specific ethnic or age group targeted or excluded.
Study design
- Primary purpose
- Health services research
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Triple blind (participant, care provider, investigator)
- Number of arms
- 2
- Model description
- This is a randomized controlled trial comparing the Ultravit High-Speed Beveled Probe with the current Alcon vitrector probe in a cohort of patients undergoing routine vitrectomy surgery.
| Arm | Type | Receives |
|---|---|---|
| Alcon Advanced Ultravit High-Speed Vitrectomy Probe | Active comparator | Device: Utravit High-Speed 10000 cpm Beveled ProbeOn the day of surgery, patients will be randomized to the Ultravit High-Speed Beveled Probe or the current non-beveled Alcon Probe. All patients will undergo routine vitrectomy surgery as scheduled; patients will be unaware of the vitrector probe used. Time to completion of vitrectomy and time to completion of vitreous base shave will be recorded by study staff unaware of the vitrector probe used. All examination will be repeated as regularly scheduled postoperative visits by a reader unaware of which probe was used. Safety will be assessed at each visit by evaluation for any adverse events. |
| Alcon Non-Beveled Tip Vitrectomy Probe | Active comparator | Device: standard vitrector probe- Alcon (non-beveled) Ultravit 7500 cpmOn the day of surgery, patients will be randomized to the Ultravit High-Speed Beveled Probe or the current non-beveled Alcon Probe. All patients will undergo routine vitrectomy surgery as scheduled; patients will be unaware of the vitrector probe used. Time to completion of vitrectomy and time to completion of vitreous base shave will be recorded by study staff unaware of the vitrector probe used. All examination will be repeated as regularly scheduled postoperative visits by a reader unaware of which probe was used. Safety will be assessed at each visit by evaluation for any adverse events. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (1 listed)
- The study population will be male and female patients 18 years old or older with the presence of pathology requiring routine vitreoretinal surgery (vitreous opacities, vitreous hemorrhage, vitreomacular traction, macular hole, epiretinal membrane) without previous history of vitreoretinal surgery. Ability to consent to procedure.
Key exclusion criteria (2 listed)
- Previous incisional intraocular surgery other than uncomplicated cataract surgery with intraocular lens placement
- Inability to consent for procedure
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Utravit High-Speed 10000 cpm Beveled ProbeThis is a randomized controlled trial comparing the Ultravit High-Speed Beveled Probe with the current Alcon vitrector probe in a cohort of patients undergoing routine vitrectomy surgery. | Device | Alcon Advanced Ultravit High-Speed Vitrectomy Probe |
| standard vitrector probe- Alcon (non-beveled) Ultravit 7500 cpmThis is a randomized controlled trial comparing the Ultravit High-Speed Beveled Probe with the current Alcon vitrector probe in a cohort of patients undergoing routine vitrectomy surgery. | Device | Alcon Non-Beveled Tip Vitrectomy Probe |
Primary outcome
Time to Completion of Core Vitrectomy and Shave of Vitreous Base
Time frame: Time to completion of core vitrectomy and shave of vitreous base (12 ± 3 minutes )
Intraoperative efficiency of vitrectomy surgery regarding time to completion of core vitrectomy and shave of vitreous base
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 21 Oct 2022.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Individual participant dataSharing planned: No
Related trials for Vitrectomy
RecruitingPhase 3
Treatment of Retinal Detachment in People Who Have Not Had Cataract Surgery With Vitrectomy vs Vitrectomy and Cataract Removal
Rhegmatogenous Retinal Detachment
Not yet recruiting
Vitrectomy Combined With Povidone-Iodine Vitreous Irrigation for Infectious Endophthalmitis
Endophthalmitis, Infectious Endophthalmitis
RecruitingPhase 1/2
Topical Netarsudil for the Prevention of Proliferative Vitreoretinopathy in Patients With Retinal Detachment
Rhegmatogenous Retinal Detachment, Proliferative Vitreoretinopathy
Not yet recruitingPhase 4
Continuous Delivery of Ranibizumab Via the Port Delivery System for Proliferative Diabetic Retinopathy-related Vitreous Hemorrhage With Pars Plana Vitrectomy and Limited PRP.
Proliferative Diabetic Retinopathy, Diabetic Retinopathy
RecruitingPhase 1/2
Autologous Transplantation of Induced Pluripotent Stem Cell-Derived Retinal Pigment Epithelium for Geographic Atrophy Associated With Age-Related Macular Degeneration
Dry Age-Related Macular Degeneration, Geographic Atrophy
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Shriji N Patel, MD principal investigator
Vanderbilt Eye Institute
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Utravit High-Speed 10000 cpm Beveled Probe and standard vitrector probe- Alcon (non-beveled) Ultravit 7500 cpm in people with Vitrectomy, run by Vanderbilt University Medical Center at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 21 Oct 2022. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 21 Oct 2022). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Time to Completion of Core Vitrectomy and Shave of Vitreous Base (time frame: Time to completion of core vitrectomy and shave of vitreous base (12 ± 3 minutes )). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 21 Oct 2022.