AzTrials
AzTrials

Coronary Heart DiseaseNCT04104854

Safety and Efficacy of DCB Therapy for de Novo Lesions Under the Guidance of QFR in CHD Patients (UNIQUE-DCB-I Study )

A study testing drug coated balloon in people with Coronary Heart Disease, run by Nanjing First Hospital, Nanjing Medical University at 1 site in China.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record
Search all trials

Trial summary

Since Gruntzig successfully performed percutaneous coronary balloon angioplasty in 1977, percutaneous coronary intervention has developed rapidly. From bare metal stents to drug-eluting stents (DES), the symptoms and prognosis of patients with coronary heart disease (CHD) have been greatly improved. Read more about this study

Who is it for?
Ages 18 to 90 years
Conditions the study is for
Coronary Heart Disease
What is being tested?
drug coated balloon
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
220 participants
Where
1 siteChina
Study dates
1 Jan 2026to 1 Dec 2028
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 90 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • ●Meet the diagnostic criteria for stable angina pectoris, unstable angina pectoris and acute myocardial infarction and QFR<0.8 of target lesion

Who cannot join

  • QFR less than 0.8, dissection above type B and thrombosis formation after pre-dilation of coronary artery lesions
  • Severe congestive heart failure [LVEF <30% or NYHA( New York Heart Association) III/IV)]
  • Severe valvular heart disease
  • Life expectancy no more than 1 year or factors causing difficulties in clinical follow up
  • Intolerance to aspirin and/or clopidogrel
  • Known intolerance or allergy to heparin, contrast agents, paclitaxel, iopromide, rapamycin, polylactic acid-glycolic acid copolymer, Co-Cr alloy or platinum-chromium alloy
Show all 10Show fewer
  • Leukopenia or thrombopenia
  • A history of peptic ulcer or GI bleeding in the previously
  • Stroke within 6 months prior to the operation
  • A history of severe hepatic or renal failure

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

China1 site
  • Nanjing First Hospital

    Nanjing, Jiangsu, 210006

    Fei Ye, MD, +86 13327823900, doctor_ye@126.com

    Xiangqi Wu, MD, +86 15250997876, 15250997876@163.com

Other trials in China

About this study

Official title: Safety and Efficacy of Drug Coated Balloon Therapy for de Novo Lesions in Patients With Coronary Heart Disease Under the Guidance of QFR (UNIQUE-DCB-I Study )

Since Gruntzig successfully performed percutaneous coronary balloon angioplasty in 1977, percutaneous coronary intervention has developed rapidly. From bare metal stents to drug-eluting stents (DES), the symptoms and prognosis of patients with coronary heart disease (CHD) have been greatly improved. Although DES has reduced the probability of in-stent restenosis (ISR) and thrombosis compared with BMS since its clinical application, it can not completely solve this problem. Even if the new generation of DES requires revascularization, the incidence of ISR is still as high as 5%-10%. DES treatment is associated with delayed endothelial healing, late acquired poor stent adherence and new atherosclerosis, which lead to late ISR and thrombosis. In addition, DES is still not ideal for the treatment of small vessel disease, diffuse long lesion and bifurcation lesion. Therefore, drug coated balloon (DCB) has attracted people's attention. Balloon-loaded antiproliferative drugs can fully release the drugs to the vascular wall during balloon dilation, which can inhibit the restenosis process from the beginning of injury, and show good efficacy and safety in some specific lesions. Many clinical studies have shown that DCB has good efficacy and safety in some specific lesions (ISR, small vessel disease, bifurcation disease, in situ lesion). Especially in the treatment of ISR, researchers believe that its efficacy is not inferior to DES, and it has the advantage of non-metal residues.

Quantitative flow ratio (QFR) is the second generation FFR detection method based on angiographic images. The diagnostic accuracy of QFR 0.80 for myocardial ischemic stenosis was 92.7%. Compared with QCA, the positive predictive value and negative predictive value of QFR were also significantly better than those of QCA. The latest FAVOR II results also confirm that QFR is more sensitive and specific in diagnosing myocardial ischemia caused by coronary artery stenosis than QCA, and confirm the feasibility of using QFR online in catheter lab to evaluate the functional significance of coronary artery critical lesions. However, there is no report on the treatment of de novo lesions in patients with coronary heart disease by DCB under the guidance of QFR. The aim of this study was to evaluate the safety and efficacy of drug balloon therapy for de novo lesions in patients with CHD under the guidance of QFR compared with DES implantation.

Read the detailed description

The current study is designed as a multicenter, randomized and prospective study aiming to evaluate the safety and efficacy of drug balloon therapy for de novo lesions in patients with CHD under the guidance of QFR compared with DES implantation. Based on previous study, the incidence rate of target lesion failure is 5%-10% in patients with CHD undergoing DES implantation. And in the investigators study the expected incidence rate of target lesion failure is up to 5.0 % in patients with CHD after treatment with DCB. Moreover, the investigators estimated 10% loss follow-up of these patients in each arm. As a result, a total of 220 patients with CHD were required, and with 110 patients per group as a ratio of 1:1 randomization.

Being tested
drug coated balloon
Keywords
Quantitative flow ratio, drug coated balloon, Drug eluted stent, percutaneous coronary intervention
Medical subject headings
Coronary Disease

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • drug coated balloonDevice

    Balloon/vessel diameter ratio 0.8-1.0, 8-12 ATM (atmosphere), lasting for >30 seconds

Study groups in NCT04104854
Study groupRoleWhat they receive
drug coated balloonExperimentalA total of 110 patients are assigned to drug coated balloon treated group after randomization schedule.
Receives: Device: drug coated balloon
drug eluted stent implantationNo interventionA total of 110 patients are assigned to drug eluted stent treated group after randomization schedule.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. The incidence rate of late lumen loss after percutaneous coronary intervention in patients with CHD

    The incidence rate of late lumen loss between DCB treated group and DES treated group evaluated by quantitative coronary analysis in patients with CHD

    Measured: Follow-up coronary angiography at 12 months after the procedure

Secondary outcomes (2)
  1. The incidence rate of device-related ischemic events

    The incidence rate of device-related ischemic events including cardiovascular death, target vessel related myocardial infarction and ischemia-driven revascularization between DCB treated group and DES treated group

    Measured: Clinical follow up at 30 days, 6, 9 and 12 months after the procedure

  2. The incidence rate of patient-related ischemic events

    The incidence rate of patient-related ischemic events including all myocardial infarction , any revascularization and all-cause death between DCB treated group and DES treated group

    Measured: Clinical follow up at 30 days, 6, 9 and 12 months after the operation

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted26 Sep 2019
  2. Study start1 Jan 2026 (estimated)
  3. Primary completion1 Dec 2028 (estimated)
  4. Study completion1 Dec 2028 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
220 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04104854
Sponsor's protocol ID
KY201909
Status last verified
May 2025
First submitted
23 Sep 2019
Last updated
31 May 2025
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No

Publications

  • de la Torre Hernandez JM, Garcia Camarero T, Lozano Ruiz-Poveda F, Urbano-Carrillo CA, Sanchez Perez I, Cano-Garcia M, Saez R, Andres Morist A, Molina E, Pinar E, Torres A, Lezcano EJ, Gutierrez H, Arnold RJ, Zueco J. Angiography and Optical Coherence Tomography Assessment of the Drug-Coated Balloon ESSENTIAL for the Treatment of In-Stent Restenosis. Cardiovasc Revasc Med. 2020 Apr;21(4):508-513. doi: 10.1016/j.carrev.2019.07.021. Epub 2019 Jul 23.

    PubMed 31401071
  • Rissanen TT, Uskela S, Eranen J, Mantyla P, Olli A, Romppanen H, Siljander A, Pietila M, Minkkinen MJ, Tervo J, Karkkainen JM; DEBUT trial investigators. Drug-coated balloon for treatment of de-novo coronary artery lesions in patients with high bleeding risk (DEBUT): a single-blind, randomised, non-inferiority trial. Lancet. 2019 Jul 20;394(10194):230-239. doi: 10.1016/S0140-6736(19)31126-2. Epub 2019 Jun 13.

    PubMed 31204115
  • Bech GJ, Pijls NH, De Bruyne B, Peels KH, Michels HR, Bonnier HJ, Koolen JJ. Usefulness of fractional flow reserve to predict clinical outcome after balloon angioplasty. Circulation. 1999 Feb 23;99(7):883-8. doi: 10.1161/01.cir.99.7.883.

    PubMed 10027810
  • Xu B, Tu S, Qiao S, Qu X, Chen Y, Yang J, Guo L, Sun Z, Li Z, Tian F, Fang W, Chen J, Li W, Guan C, Holm NR, Wijns W, Hu S. Diagnostic Accuracy of Angiography-Based Quantitative Flow Ratio Measurements for Online Assessment of Coronary Stenosis. J Am Coll Cardiol. 2017 Dec 26;70(25):3077-3087. doi: 10.1016/j.jacc.2017.10.035. Epub 2017 Oct 31.

    PubMed 29101020

Questions about this trial

What is this clinical trial studying?

A study testing drug coated balloon in people with Coronary Heart Disease, run by Nanjing First Hospital, Nanjing Medical University at 1 site in China.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 10 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 31 May 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Fei Ye, MD (+86 13327823900, doctor_ye@126.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

The incidence rate of late lumen loss after percutaneous coronary intervention in patients with CHD (time frame: Follow-up coronary angiography at 12 months after the procedure). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04104854, which also lists 4 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 31 May 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in