Visual Pathway DisorderproVVFNCT04110015
Assessment of Visual Function in Ophthalmic Disorders Using Virtual Visual Field Analysis
An observational study of Visual Pathway Disorder and Glaucoma, run by New York City Health and Hospitals Corporation at 1 site in United States.
Trial summary
1. To evaluate the accuracy of virtual visual field (VVF) headsets equipped the standard visual field software in its ability to assess visual function in various retinal, glaucoma and neuro-ophthalmic disorders by comparing retinal fundus and optic nerve images, optical coherence tomography and neuroimages to the VVF… Read more about this study
- Who is it for?
- Ages 18 years and olderHealthy volunteers can take part
- Conditions the study is for
- Visual Pathway Disorder, Glaucoma, Retinal Disease
- What is being tested?
- virtual visual field
- Type of treatment
- Medical device
- How many people
- 120 participants
- Where
- 1 siteUnited States
- Study dates
- 1 Oct 2020to 23 Aug 2021
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Study population: All consecutive patients (>18yrs old) with glaucoma, retinal or neurological disorders able to understand, consent and deemed physically able to perform the visual field tests.
Who may be able to join
- Patients with retina, glaucoma and neuroophthalmic disorders
- Patients with normal eye exams to act as controls
- Must be able to comprehend instructions and perform visual fields
Who cannot join
- Patients <18years old
- Patients unable to comprehend visual field instructions or unwilling to participate
- Patients lacking a complete clinical file or lacking a specific diagnosis
Trial locations and contacts
1 site in 1 country.
About this study
- To evaluate the accuracy of virtual visual field (VVF) headsets equipped the standard visual field software in its ability to assess visual function in various retinal, glaucoma and neuro-ophthalmic disorders by comparing retinal fundus and optic nerve images, optical coherence tomography and neuroimages to the VVF produced.
- To test the null hypothesis that VVF testing compares favorably to the gold standard, Humphrey visual field (HVF) by comparing testing time, mean sensitivity, markers of reliability including false positives and negatives and fixation losses and global indices such as mean deviation and pattern standard deviation.
Read the detailed description
- Study Style: Prospective, Controlled Clinical Trial
- Objectives:
- To determine the capacity for a portable head-mounted virtual visual field-testing device, with capacity for remote testing, to accurately analyze visual function in various retina, neuro-ophthalmic and glaucoma disorders.
- To compare virtual visual field results with the "gold standard," Humphrey visual fields.
- Subjects: Consecutive patients already scheduled for visual fields for various retina, glaucoma and neuro-ophthalmic conditions and normal controls.
SETTING AND PROTOCOL FOR HUMAN RESEARCH:
- Location: Ophthalmology Department, Jacobi Medical Center, Bronx New York.
- Recruitment: Patients already presenting to the eye clinic or seen on the wards at Jacobi Medical Center will be offered a chance to participate as volunteers. No other active recruitment will be done.
- Retention and Dropout: Investigators will encourage patients to complete their testing. However, it will be made clear that they can drop out at any time without need to provide a reason. Dropouts will be replaced with other consenting patients.
- Protocol (Interventions and Timing):
- Consecutive patients presenting to the Jacobi eye clinic and wards who are diagnosed with neurologic, glaucoma and retina conditions and already are scheduled to have Humphrey visual field analysis, will be asked if they would like to voluntarily participate in this study.
- Interested patients will be have the study explained to them and an informed consent taken by the study resident/technician.
- The standard Humphrey visual field (HVF) will be conducted by the technician (5-10 minutes) in the usual manner.
- The option of doing the virtual fields immediately, on the same day, will be offered vs returning to conduct the test within 3 months.
- The virtual reality headset will be applied and instructions in the patient's preferred language provided through the earpiece of the virtual visual field (VVF). When the patient indicates they wish to proceed, the test will be started by the technician.
- The technician is already versed in conducting both versions of the visual field tests.
- Clinical Analysis: All fields will be stored digitally within each Health Insurance Portability and Accountability Act (HIPAA) compliant device-specific website for later analyses by respective Attendings (glaucoma, retina and neuro-ophthalmology/neurology).
- Data Collection:
- The patients' demographic details, visual field pattern deviation, and global indices (mean deviation, f and pattern standard deviation) and reliability indices (fixation losses, false positives/negatives will be documented in the data collection Excel sheet.
- Supporting ancillary tests (optical coherence tomography, retina photography and neuroimaging) will be collected for each patient and reported findings documented. These tests are part of normal standard of care assessment of patients at Jacobi Medical Center.
STUDY POPULATION:
- Consecutive clinic and ward patients (>18yrs old) with glaucoma, retinal or neurological disorders able to understand, consent and deemed physically able to perform the visual field tests.
- Power Calculation:
- Alpha 0.05
- Power 80%
- Using the findings of mean deviation (MD) in perception of light from a previous VVF glaucoma study : mean (SD)=-3.78 (7.49) dB units in glaucoma patients and 0.587 (2.588) dB in the controls.
- 39 patients and 39 controls in each sub-population (retina, glaucoma and neuro-ophthalmology) will be required to sufficiently power the study. Round numbers of 40 cases and 40 controls for each study to be sufficiently powered.
For all three studies, 120 study cases in total will be tested with clinical conditions and 120 normal cases as normal controls. 240 cases in total will be tested.There will be confounding variables that can be addressed with subgroup analysis or multivariate regression analysis.
INFORMED CONSENT:
- The informed consent to participate in the study will be taken at the site of testing at Jacobi Medical Center.
- The informed consent will be taken by one of the study residents or the study technician.
STATISTICAL ANALYSIS: Excel and SAS (Statistical Analysis Software, SAS institute Inc. Cary, North Carolina, USA) software will be used for descriptive assessment and statistical analysis of the data set and generation of graphs.
- Data will be used to test the hypothesis that the virtual visual field headset is able to accurately detect visual field defects in ophthalmic conditions and develops visual field maps and global indices that compare favorably with the gold standard, Humphrey visual fields.
- Interim analyses will be conducted for each sub-population (glaucoma, retina, neurology) when they reach the power number ~40.
- Once all data is de-identified, it will be analyzed using SAS software.
- Descriptive data will be determined with basic percentages.
- Aggregate means of global indices of each study group: retina disorders, glaucoma of all stages (1-mild; 2-moderate; 3-severe; 4-indeterminate) and neuro-ophthalmic conditions, will be compared with their control group and VVF compared to HVFusing t-test, Chi-square, Mann-Whitney and Kruskal-Wallis tests.
- Correlation between the parameters of virtual visual field test and Humphrey visual field including time for test, mean sensitivity (MS, expressed in decibels), fixation loss (FL), false negative (FN), false positive (FP), mean deviation (MD) and pattern standard deviation (PSD) will be assessed using linear regression models that will account for confounding variables such as age, visual acuity and other ocular conditions.
- Statistical significance will be set at p<0.05.
- Conditions
- Visual Pathway Disorder, Glaucoma, Retinal Disease
- Being tested
- virtual visual field
- Medical subject headings
- Glaucoma, Retinal Diseases
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
virtual visual fieldDevice
Patients with identified conditions will be invited to do a virtual visual field test with virtual reality headsets.
| Study group | Role | What they receive |
|---|---|---|
| Neurology patients | Any patients with neurological disorders Receives: Device: virtual visual field | |
| Glaucoma patients | Any patients with chronic open angle and chronic angle closure glaucoma of all stages Receives: Device: virtual visual field | |
| Retina patients | Any patients with known retinal conditions Receives: Device: virtual visual field |
What is being measured
The primary outcome is the main question the study is designed to answer.
Virtual visual field result
Gray scale pattern will reveal areas of vision loss or visual depression; this will have a numerical total deviation plot giving numbers in decibels of the points in the visual field of depressed or lost points of vision. Global indices also will be recorded; these give numerical quantification in decibel units of visual field loss. and include: mean deviation - the average of all decreased perception, pattern deviation which highlights localized losses and pattern standard deviation which quantifies the amount of loss and gauges progression. Time take to complete fields and reliability indices will be recorded: fixation losses, false positives, false negatives
Measured: with 3 months
Humphrey visual field result
Gray scale pattern will reveal areas of vision loss or visual depression; this will have a numerical total deviation plot giving numbers in decibels of the points in the visual field of depressed or lost points of vision. Global indices also will be recorded; these give numerical quantification in decibel units of visual field loss. and include: mean deviation - the average of all decreased perception, pattern deviation which highlights localized losses and pattern standard deviation which quantifies the amount of loss and gauges progression.
Measured: within 3 months
Secondary outcomes (1)
Comparison of Virtual Visual field (VVF) to Humphrey visual fields (HVF)
Comparison of patterns, global indices and reliability indices between VVF and controls and then VVF and HVF.
Measured: At end of study when we have all the data ~ one year
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted1 Oct 2019
- Study start1 Oct 2020
- Primary completion30 Oct 2020
- Study completion23 Aug 2021
Why it stopped: New heightened internet security at HHC and VVF device no longer compliant with intranet and internet access at hospital
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Visual Pathway DisorderStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 120 participants (actual)
Sponsor and investigators
- Lead sponsor
- New York City Health and Hospitals Corporation
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Joyce Mbekeani, New York City Health and Hospitals Corporation
- Investigators
- JOYCE MBEKEANI, Principal investigator, Albert Einstein College of Medicine
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04110015
- Sponsor's protocol ID
- 2019-10418
- Other IDs
- 2019
- Acronym
- proVVF
- Status last verified
- Aug 2021
- First submitted
- 21 Sep 2019
- Last updated
- 30 Aug 2021
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No: No plans to share data.
Study at a glance
From the registry record, last updated by the sponsor on 30 Aug 2021. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Assessment of Visual Function in Ophthalmic Disorders Using Virtual Visual Field Analysis
- ClinicalTrials.gov ID
- NCT04110015
- Acronym / sponsor ID
- proVVF / 2019-10418
- Conditions
- Visual Pathway Disorder, Glaucoma, Retinal Disease
- Study type
- Observational
- Recruitment status
- TerminatedReason stopped: New heightened internet security at HHC and VVF device no longer compliant with intranet and internet access at hospital
- Enrolment
- 120 participants (actual)
- Lead sponsor
- New York City Health and Hospitals CorporationUniversity, hospital or other
- Study start
- 1 Oct 2020 (actual)
- Primary completion
- 30 Oct 2020 (actual)
- Study completion
- 23 Aug 2021 (actual)
- First posted
- 1 Oct 2019 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
- To evaluate the accuracy of virtual visual field (VVF) headsets equipped the standard visual field software in its ability to assess visual function in various retinal, glaucoma and neuro-ophthalmic disorders by comparing retinal fundus and optic nerve images, optical coherence tomography and neuroimages to the VVF produced.
- To test the null hypothesis that VVF testing compares favorably to the gold standard, Humphrey visual field (HVF) by comparing testing time, mean sensitivity, markers of reliability including false positives and negatives and fixation losses and global indices such as mean deviation and pattern standard deviation.
Detailed description
- Study Style: Prospective, Controlled Clinical Trial
- Objectives:
- To determine the capacity for a portable head-mounted virtual visual field-testing device, with capacity for remote testing, to accurately analyze visual function in various retina, neuro-ophthalmic and glaucoma disorders.
- To compare virtual visual field results with the "gold standard," Humphrey visual fields.
- Subjects: Consecutive patients already scheduled for visual fields for various retina, glaucoma and neuro-ophthalmic conditions and normal controls.
SETTING AND PROTOCOL FOR HUMAN RESEARCH:
- Location: Ophthalmology Department, Jacobi Medical Center, Bronx New York.
- Recruitment: Patients already presenting to the eye clinic or seen on the wards at Jacobi Medical Center will be offered a chance to participate as volunteers. No other active recruitment will be done.
- Retention and Dropout: Investigators will encourage patients to complete their testing. However, it will be made clear that they can drop out at any time without need to provide a reason. Dropouts will be replaced with other consenting patients.
- Protocol (Interventions and Timing):
- Consecutive patients presenting to the Jacobi eye clinic and wards who are diagnosed with neurologic, glaucoma and retina conditions and already are scheduled to have Humphrey visual field analysis, will be asked if they would like to voluntarily participate in this study.
- Interested patients will be have the study explained to them and an informed consent taken by the study resident/technician.
- The standard Humphrey visual field (HVF) will be conducted by the technician (5-10 minutes) in the usual manner.
- The option of doing the virtual fields immediately, on the same day, will be offered vs returning to conduct the test within 3 months.
- The virtual reality headset will be applied and instructions in the patient's preferred language provided through the earpiece of the virtual visual field (VVF). When the patient indicates they wish to proceed, the test will be started by the technician.
- The technician is already versed in conducting both versions of the visual field tests.
- Clinical Analysis: All fields will be stored digitally within each Health Insurance Portability and Accountability Act (HIPAA) compliant device-specific website for later analyses by respective Attendings (glaucoma, retina and neuro-ophthalmology/neurology).
- Data Collection:
- The patients' demographic details, visual field pattern deviation, and global indices (mean deviation, f and pattern standard deviation) and reliability indices (fixation losses, false positives/negatives will be documented in the data collection Excel sheet.
- Supporting ancillary tests (optical coherence tomography, retina photography and neuroimaging) will be collected for each patient and reported findings documented. These tests are part of normal standard of care assessment of patients at Jacobi Medical Center.
STUDY POPULATION:
- Consecutive clinic and ward patients (>18yrs old) with glaucoma, retinal or neurological disorders able to understand, consent and deemed physically able to perform the visual field tests.
- Power Calculation:
- Alpha 0.05
- Power 80%
- Using the findings of mean deviation (MD) in perception of light from a previous VVF glaucoma study : mean (SD)=-3.78 (7.49) dB units in glaucoma patients and 0.587 (2.588) dB in the controls.
- 39 patients and 39 controls in each sub-population (retina, glaucoma and neuro-ophthalmology) will be required to sufficiently power the study. Round numbers of 40 cases and 40 controls for each study to be sufficiently powered.
For all three studies, 120 study cases in total will be tested with clinical conditions and 120 normal cases as normal controls. 240 cases in total will be tested.There will be confounding variables that can be addressed with subgroup analysis or multivariate regression analysis.
INFORMED CONSENT:
- The informed consent to participate in the study will be taken at the site of testing at Jacobi Medical Center.
- The informed consent will be taken by one of the study residents or the study technician.
STATISTICAL ANALYSIS: Excel and SAS (Statistical Analysis Software, SAS institute Inc. Cary, North Carolina, USA) software will be used for descriptive assessment and statistical analysis of the data set and generation of graphs.
- Data will be used to test the hypothesis that the virtual visual field headset is able to accurately detect visual field defects in ophthalmic conditions and develops visual field maps and global indices that compare favorably with the gold standard, Humphrey visual fields.
- Interim analyses will be conducted for each sub-population (glaucoma, retina, neurology) when they reach the power number ~40.
- Once all data is de-identified, it will be analyzed using SAS software.
- Descriptive data will be determined with basic percentages.
- Aggregate means of global indices of each study group: retina disorders, glaucoma of all stages (1-mild; 2-moderate; 3-severe; 4-indeterminate) and neuro-ophthalmic conditions, will be compared with their control group and VVF compared to HVFusing t-test, Chi-square, Mann-Whitney and Kruskal-Wallis tests.
- Correlation between the parameters of virtual visual field test and Humphrey visual field including time for test, mean sensitivity (MS, expressed in decibels), fixation loss (FL), false negative (FN), false positive (FP), mean deviation (MD) and pattern standard deviation (PSD) will be assessed using linear regression models that will account for confounding variables such as age, visual acuity and other ocular conditions.
- Statistical significance will be set at p<0.05.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
- Number of arms
- 3
| Arm | Type | Receives |
|---|---|---|
| Neurology patients | – | Device: virtual visual fieldAny patients with neurological disorders |
| Glaucoma patients | – | Device: virtual visual fieldAny patients with chronic open angle and chronic angle closure glaucoma of all stages |
| Retina patients | – | Device: virtual visual fieldAny patients with known retinal conditions |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
- Study population
- All consecutive patients (>18yrs old) with glaucoma, retinal or neurological disorders able to understand, consent and deemed physically able to perform the visual field tests.
Key inclusion criteria (3 listed)
- Patients with retina, glaucoma and neuroophthalmic disorders
- Patients with normal eye exams to act as controls
- Must be able to comprehend instructions and perform visual fields
Key exclusion criteria (3 listed)
- Patients <18years old
- Patients unable to comprehend visual field instructions or unwilling to participate
- Patients lacking a complete clinical file or lacking a specific diagnosis
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| virtual visual fieldPatients with identified conditions will be invited to do a virtual visual field test with virtual reality headsets. | Device | Glaucoma patients, Neurology patients, Retina patients |
Primary outcome
Virtual visual field result
Time frame: with 3 months
Gray scale pattern will reveal areas of vision loss or visual depression; this will have a numerical total deviation plot giving numbers in decibels of the points in the visual field of depressed or lost points of vision. Global indices also will be recorded; these give numerical quantification in decibel units of visual field loss. and include: mean deviation - the average of all decreased perception, pattern deviation which highlights localized losses and pattern standard deviation which quantifies the amount of loss and gauges progression. Time take to complete fields and reliability indices will be recorded: fixation losses, false positives, false negatives
Humphrey visual field result
Time frame: within 3 months
Gray scale pattern will reveal areas of vision loss or visual depression; this will have a numerical total deviation plot giving numbers in decibels of the points in the visual field of depressed or lost points of vision. Global indices also will be recorded; these give numerical quantification in decibel units of visual field loss. and include: mean deviation - the average of all decreased perception, pattern deviation which highlights localized losses and pattern standard deviation which quantifies the amount of loss and gauges progression.
1 secondary outcome
Comparison of Virtual Visual field (VVF) to Humphrey visual fields (HVF)
Time frame: At end of study when we have all the data ~ one year
Results and safety
The study was stopped early (reason given: New heightened internet security at HHC and VVF device no longer compliant with intranet and internet access at hospital). Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 30 Aug 2021.
- Individual participant dataSharing planned: No. No plans to share data.
Related trials for Visual Pathway Disorder
Active, not recruitingPhase 1/2
Selumetinib in Treating Young Patients With Recurrent or Refractory Low Grade Glioma
Low Grade Glioma, Recurrent Childhood Pilocytic Astrocytoma
Active, not recruitingPhase 3
A Study of the Drugs Selumetinib Versus Carboplatin/Vincristine in Patients With Neurofibromatosis and Low-Grade Glioma
Low Grade Glioma, Neurofibromatosis Type 1
Recruiting
Validating a Neurocognitive Remediation Model for Visual-Attentional Pathway in Chinese Developmental Dyslexia
Dyslexia
Enrolling by invitationObservational study
Implementation of the NEDS EyeCTester App
Optic Nerve Disease, Macular Disease
Recruiting
Non-invasive Brain Stimulation Using Tdcs of the Third (of Many) Visual Pathways
SCHIZOPHRENIA 1 (Disorder), Schizo Affective Disorder
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
JOYCE MBEKEANI principal investigator
Albert Einstein College of Medicine
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Visual Pathway Disorder and Glaucoma, run by New York City Health and Hospitals Corporation at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: stopped early, as of the sponsor's last update on 30 Aug 2021. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study was stopped early (reason given: New heightened internet security at HHC and VVF device no longer compliant with intranet and internet access at hospital). Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Virtual visual field result (time frame: with 3 months). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 30 Aug 2021.