Chronic Kidney DiseasesNCT04127877
Bio Impedance-assisted Monitoring of Chronic Hemodialysis Patients
A study testing NICAS in people with Chronic Kidney Diseases and Hemodialysis Complication, run by Assuta Ashdod Hospital at 1 site in Israel.
Trial summary
Hemodynamic trends will be assessed using the device, in 100 dialysis sessions in 30 patients, who are prone to develop hypotensive episode during dialysis. Sitting blood pressures will be measured immediately prior to each hemodynamic measurement: before initiation of dialysis, every each hour and in the beginning of… Read more about this study
- Who is it for?
- Ages 18 to 85 years
- Conditions the study is for
- Chronic Kidney Diseases, Hemodialysis Complication
- What is being tested?
- NICAS
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 30 participants
- Where
- 1 siteIsrael
- Study dates
- 18 Nov 2018to 31 Dec 2020
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 85 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- -Chronic hemodialysis patients
Who cannot join
- Age limits
Trial locations and contacts
1 site in 1 country.
Israel1 site, 1 recruiting
- Recruiting
Nephrology and Hypertention Institute, hemodialysis unit
Ashdod, 7747629
Ze'ev Katzir, MD, 972 052 6300563, zeevk@assuta.co.il
About this study
Official title: Regional Electric Bio Impedance-assisted Monitoring of Cardiac, Vascular Resistance and Fluid Balance, in Chronic Hemodialysis Patients
Hemodynamic trends will be assessed using the device, in 100 dialysis sessions in 30 patients, who are prone to develop hypotensive episode during dialysis. Sitting blood pressures will be measured immediately prior to each hemodynamic measurement: before initiation of dialysis, every each hour and in the beginning of hypotension episode, just before the end and 10 min after the end of the treatment.
Gender, age, height, weight, electrode location and blood pressure data will be entered into the device. The device will measure and calculate hemodynamic parameters on each heart beat during 60 s and provides the averaged parameters.
Read more
Technology for hemodynamic measurements:
The device (NICaS, NI Medical) is a noninvasive regional bioimpedance cardiac measurement and analysis system (FDA 510k clearance no. K080941, 12 June 2009). The US Food and Drug Administration indication for use of the device states 'NICaS is intended to monitor and display hemodynamic parameters in males and females with known or suspected cardiac disorders needing cardiac assessment'.
SV will be measured by applying an alternating electrical current of 1.4mA at 30 kHz frequency through the patient's body via two pairs of tetrapolar sensors, one pair placed on the wrist of the nonaccess arm above the radial pulse and the other pair on the contralateral ankle above the posterior tibial pulse (Figure 1).
Figure 1 : Sensor location
SV is calculated by Frinerman's formula:
SV¼(dR/R) - q - (L2/Ri) - (ab)/b - KW - HF [2-4], where dR is the impedance change in the arterial system as a result of intraarterial expansion during systole, R is basal resistance, q is blood electrical resistance, L is the patient's height, Ri is basal resistance corrected for gender and age, KWis the correction of weight according to ideal values, HF is a hydration factor that takes into account the ratio between R and body mass index (BMI), which is correlated to body water volume, ab is the electrocardiogram (ECG) R-R wave interval and b is the diastolic time interval. SV is automatically calculated every 20 s and is the average of three measurements obtained consecutively during 60 s of monitoring. The SV index is calculated as SV/body surface area using the Du Bois formula [11]. Heart rate is calculated from a one channel ECG and cardiac (output) index¼SV index - heart rate/1000. Using an oscillometric method, sitting systolic and diastolic blood pressure measurements were made automatically by the dialysis machine. Mean arterial pressure [2 - (diastolicsystolic)/3], cardiac power index [CPI; mean arterial pressure (MAP) -cardiac index - 0.0022 w/m2; normal range 0.45-0.85w/m2] [12, 13] and total peripheral resistance (MAP/ cardiac index - 80 dyn - s/cm5 - m2; normal range 1600-3000 dyn - s/cm5- m2) [13] will be calculated.
As the device measures pulsatile flow and is blinded to constant flow, fluid removal during dialysis has no impact on measurement accuracy. This was recently validated by correlating SV to ECG measurements during hemodialysis treatments. Good correlation was maintained during treatment. Further, NICaS performance immunity to fluid reduction was demonstrated by the maintenance of correlation to ECG results throughout dialysis treatments [9]. The results are drawn on hemodynamic graphs showing the MAP (y-axis) as a function of cardiac index (x-axis); curves of total peripheral resistance index (TPRI) and CPI are displayed. Ranges for the normal population are depicted by a dotted octagon.
Read the detailed description
Hemodynamic trends will be assessed using the device, in 100 dialysis sessions in 30 patients, who are prone to develop hypotensive episode during dialysis. Sitting blood pressures will be measured immediately prior to each hemodynamic measurement: before initiation of dialysis, every each hour and in the beginning of hypotension episode, just before the end and 10 min after the end of the treatment.
Gender, age, height, weight, electrode location and blood pressure data will be entered into the device. The device will measure and calculate hemodynamic parameters on each heart beat during 60 s and provides the averaged parameters.
Technology for hemodynamic measurements:
The device (NICaS, NI Medical) is a noninvasive regional bioimpedance cardiac measurement and analysis system (FDA 510k clearance no. K080941, 12 June 2009). The US Food and Drug Administration indication for use of the device states 'NICaS is intended to monitor and display hemodynamic parameters in males and females with known or suspected cardiac disorders needing cardiac assessment'.
SV will be measured by applying an alternating electrical current of 1.4mA at 30 kHz frequency through the patient's body via two pairs of tetrapolar sensors, one pair placed on the wrist of the nonaccess arm above the radial pulse and the other pair on the contralateral ankle above the posterior tibial pulse (Figure 1).
Figure 1 : Sensor location
SV is calculated by Frinerman's formula:
SV¼(dR/R) - q - (L2/Ri) - (ab)/b - KW - HF [2-4], where dR is the impedance change in the arterial system as a result of intraarterial expansion during systole, R is basal resistance, q is blood electrical resistance, L is the patient's height, Ri is basal resistance corrected for gender and age, KWis the correction of weight according to ideal values, HF is a hydration factor that takes into account the ratio between R and body mass index (BMI), which is correlated to body water volume, ab is the electrocardiogram (ECG) R-R wave interval and b is the diastolic time interval. SV is automatically calculated every 20 s and is the average of three measurements obtained consecutively during 60 s of monitoring. The SV index is calculated as SV/body surface area using the Du Bois formula [11]. Heart rate is calculated from a one channel ECG and cardiac (output) index¼SV index - heart rate/1000. Using an oscillometric method, sitting systolic and diastolic blood pressure measurements were made automatically by the dialysis machine. Mean arterial pressure [2 - (diastolicsystolic)/3], cardiac power index [CPI; mean arterial pressure (MAP) -cardiac index - 0.0022 w/m2; normal range 0.45-0.85w/m2] [12, 13] and total peripheral resistance (MAP/ cardiac index - 80 dyn - s/cm5 - m2; normal range 1600-3000 dyn - s/cm5- m2) [13] will be calculated.
As the device measures pulsatile flow and is blinded to constant flow, fluid removal during dialysis has no impact on measurement accuracy. This was recently validated by correlating SV to ECG measurements during hemodialysis treatments. Good correlation was maintained during treatment. Further, NICaS performance immunity to fluid reduction was demonstrated by the maintenance of correlation to ECG results throughout dialysis treatments [9]. The results are drawn on hemodynamic graphs showing the MAP (y-axis) as a function of cardiac index (x-axis); curves of total peripheral resistance index (TPRI) and CPI are displayed. Ranges for the normal population are depicted by a dotted octagon.
- Conditions
- Chronic Kidney Diseases, Hemodialysis Complication
- Being tested
- NICAS
- Medical subject headings
- Renal Insufficiency, Chronic
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
NICASDevice
Electric regional bio impedance device
| Study group | Role | What they receive |
|---|---|---|
| CHRONIC HEMODIALYSIS PATIENTS, NICAS-ASSISTED MONITORING | Experimental | Chronic hemodialysis patients, NICAS-assisted monitored Receives: Device: NICAS |
| Control hemodialysis patients | No intervention | Chronic hemodialysis patients, conventional clinical care and monitoring. |
What is being measured
The primary outcome is the main question the study is designed to answer.
Hemodynamic adverse events
Extreme blood pressure decrease, hospitalization, death
Measured: One year
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted16 Oct 2019
- Study start18 Nov 2018
- Primary completion31 Dec 2019 (estimated)
- Study completion31 Dec 2020 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Chronic Kidney DiseasesStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Prevention
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Model description
- Randomized Controlled study
- Masking
- None (open label)
- Enrolment
- 30 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Assuta Ashdod Hospital
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Adi Leiba, Assuta Ashdod Hospital
- Investigators
- Adi Leiba, Prof, Principal investigator, ASSUTA HOSPITAL ASHDOD
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04127877
- Sponsor's protocol ID
- 0069-18
- Status last verified
- Oct 2019
- First submitted
- 13 Oct 2019
- Last updated
- 16 Oct 2019
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 16 Oct 2019. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Regional Electric Bio Impedance-assisted Monitoring of Cardiac, Vascular Resistance and Fluid Balance, in Chronic Hemodialysis Patients
- ClinicalTrials.gov ID
- NCT04127877
- Acronym / sponsor ID
- 0069-18
- Conditions
- Chronic Kidney Diseases, Hemodialysis Complication
- Study type
- Interventional
- Recruitment status
- Unknown status
- Enrolment
- 30 participants (estimated)
- Lead sponsor
- Assuta Ashdod HospitalUniversity, hospital or other
- Study start
- 18 Nov 2018 (actual)
- Primary completion
- 31 Dec 2019 (estimated)
- Study completion
- 31 Dec 2020 (estimated)
- First posted
- 16 Oct 2019 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Hemodynamic trends will be assessed using the device, in 100 dialysis sessions in 30 patients, who are prone to develop hypotensive episode during dialysis. Sitting blood pressures will be measured immediately prior to each hemodynamic measurement: before initiation of dialysis, every each hour and in the beginning of hypotension episode, just before the end and 10 min after the end of the treatment.
Gender, age, height, weight, electrode location and blood pressure data will be entered into the device. The device will measure and calculate hemodynamic parameters on each heart beat during 60 s and provides the averaged parameters.
Technology for hemodynamic measurements:
The device (NICaS, NI Medical) is a noninvasive regional bioimpedance cardiac measurement and analysis system (FDA 510k clearance no. K080941, 12 June 2009). The US Food and Drug Administration indication for use of the device states 'NICaS is intended to monitor and display hemodynamic parameters in males and females with known or suspected cardiac disorders needing cardiac assessment'.
SV will be measured by applying an alternating electrical current of 1.4mA at 30 kHz frequency through the patient's body via two pairs of tetrapolar sensors, one pair placed on the wrist of the nonaccess arm above the radial pulse and the other pair on the contralateral ankle above the posterior tibial pulse (Figure 1).
Figure 1 : Sensor location
SV is calculated by Frinerman's formula:
SV¼(dR/R) - q - (L2/Ri) - (ab)/b - KW - HF [2-4], where dR is the impedance change in the arterial system as a result of intraarterial expansion during systole, R is basal resistance, q is blood electrical resistance, L is the patient's height, Ri is basal resistance corrected for gender and age, KWis the correction of weight according to ideal values, HF is a hydration factor that takes into account the ratio between R and body mass index (BMI), which is correlated to body water volume, ab is the electrocardiogram (ECG) R-R wave interval and b is the diastolic time interval. SV is automatically calculated every 20 s and is the average of three measurements obtained consecutively during 60 s of monitoring. The SV index is calculated as SV/body surface area using the Du Bois formula [11]. Heart rate is calculated from a one channel ECG and cardiac (output) index¼SV index - heart rate/1000. Using an oscillometric method, sitting systolic and diastolic blood pressure measurements were made automatically by the dialysis machine. Mean arterial pressure [2 - (diastolicsystolic)/3], cardiac power index [CPI; mean arterial pressure (MAP) -cardiac index - 0.0022 w/m2; normal range 0.45-0.85w/m2] [12, 13] and total peripheral resistance (MAP/ cardiac index - 80 dyn - s/cm5 - m2; normal range 1600-3000 dyn - s/cm5- m2) [13] will be calculated.
As the device measures pulsatile flow and is blinded to constant flow, fluid removal during dialysis has no impact on measurement accuracy. This was recently validated by correlating SV to ECG measurements during hemodialysis treatments. Good correlation was maintained during treatment. Further, NICaS performance immunity to fluid reduction was demonstrated by the maintenance of correlation to ECG results throughout dialysis treatments [9]. The results are drawn on hemodynamic graphs showing the MAP (y-axis) as a function of cardiac index (x-axis); curves of total peripheral resistance index (TPRI) and CPI are displayed. Ranges for the normal population are depicted by a dotted octagon.
Detailed description
Hemodynamic trends will be assessed using the device, in 100 dialysis sessions in 30 patients, who are prone to develop hypotensive episode during dialysis. Sitting blood pressures will be measured immediately prior to each hemodynamic measurement: before initiation of dialysis, every each hour and in the beginning of hypotension episode, just before the end and 10 min after the end of the treatment.
Gender, age, height, weight, electrode location and blood pressure data will be entered into the device. The device will measure and calculate hemodynamic parameters on each heart beat during 60 s and provides the averaged parameters.
Technology for hemodynamic measurements:
The device (NICaS, NI Medical) is a noninvasive regional bioimpedance cardiac measurement and analysis system (FDA 510k clearance no. K080941, 12 June 2009). The US Food and Drug Administration indication for use of the device states 'NICaS is intended to monitor and display hemodynamic parameters in males and females with known or suspected cardiac disorders needing cardiac assessment'.
SV will be measured by applying an alternating electrical current of 1.4mA at 30 kHz frequency through the patient's body via two pairs of tetrapolar sensors, one pair placed on the wrist of the nonaccess arm above the radial pulse and the other pair on the contralateral ankle above the posterior tibial pulse (Figure 1).
Figure 1 : Sensor location
SV is calculated by Frinerman's formula:
SV¼(dR/R) - q - (L2/Ri) - (ab)/b - KW - HF [2-4], where dR is the impedance change in the arterial system as a result of intraarterial expansion during systole, R is basal resistance, q is blood electrical resistance, L is the patient's height, Ri is basal resistance corrected for gender and age, KWis the correction of weight according to ideal values, HF is a hydration factor that takes into account the ratio between R and body mass index (BMI), which is correlated to body water volume, ab is the electrocardiogram (ECG) R-R wave interval and b is the diastolic time interval. SV is automatically calculated every 20 s and is the average of three measurements obtained consecutively during 60 s of monitoring. The SV index is calculated as SV/body surface area using the Du Bois formula [11]. Heart rate is calculated from a one channel ECG and cardiac (output) index¼SV index - heart rate/1000. Using an oscillometric method, sitting systolic and diastolic blood pressure measurements were made automatically by the dialysis machine. Mean arterial pressure [2 - (diastolicsystolic)/3], cardiac power index [CPI; mean arterial pressure (MAP) -cardiac index - 0.0022 w/m2; normal range 0.45-0.85w/m2] [12, 13] and total peripheral resistance (MAP/ cardiac index - 80 dyn - s/cm5 - m2; normal range 1600-3000 dyn - s/cm5- m2) [13] will be calculated.
As the device measures pulsatile flow and is blinded to constant flow, fluid removal during dialysis has no impact on measurement accuracy. This was recently validated by correlating SV to ECG measurements during hemodialysis treatments. Good correlation was maintained during treatment. Further, NICaS performance immunity to fluid reduction was demonstrated by the maintenance of correlation to ECG results throughout dialysis treatments [9]. The results are drawn on hemodynamic graphs showing the MAP (y-axis) as a function of cardiac index (x-axis); curves of total peripheral resistance index (TPRI) and CPI are displayed. Ranges for the normal population are depicted by a dotted octagon.
Study design
- Primary purpose
- Prevention
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Number of arms
- 2
- Model description
- Randomized Controlled study
| Arm | Type | Receives |
|---|---|---|
| CHRONIC HEMODIALYSIS PATIENTS, NICAS-ASSISTED MONITORING | Experimental | Device: NICASChronic hemodialysis patients, NICAS-assisted monitored |
| Control hemodialysis patients | No intervention | –Chronic hemodialysis patients, conventional clinical care and monitoring. |
Who may qualify
- Ages
- 18 to 85 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (1 listed)
- -Chronic hemodialysis patients
Key exclusion criteria (1 listed)
- Age limits
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| NICASElectric regional bio impedance device | Device | CHRONIC HEMODIALYSIS PATIENTS, NICAS-ASSISTED MONITORING |
Primary outcome
Hemodynamic adverse events
Time frame: One year
Extreme blood pressure decrease, hospitalization, death
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 16 Oct 2019.
- Individual participant dataSharing planned: No
Related trials for Chronic Kidney Diseases
Active, not recruitingPhase 2
Safety and Efficacy of Empagliflozin in Hemodialysis
End Stage Renal Disease
RecruitingPhase 3
Study to Assess the Efficacy, Pharmacokinetics, Safety and Tolerability of Atrasentan in Pediatric Patients With Primary IgAN
Berger Disease, Bergers Disease
Recruiting
Investigating Vascular Properties of HEMI and SPG Signals in Individuals With or at Risk for Chronic Kidney Disease
Chronic Kidney Disease, Hypertension (HTN)
Not yet recruiting
Hypothermic Kidney Machine Perfusion With Omnisol
End Stage Renal Disease (ESRD), Kidney Transplant
Not yet recruiting
An Individuation Intervention to Reduce Socioeconomic Disparities in Chronic Kidney Disease Care
Chronic Kidney Diseases
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Adi Leiba, Prof principal investigator
ASSUTA HOSPITAL ASHDOD
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing NICAS in people with Chronic Kidney Diseases and Hemodialysis Complication, run by Assuta Ashdod Hospital at 1 site in Israel.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 16 Oct 2019. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Israel. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
Contact Ze'ev Katzir, MD (972052 6300563, zeevk@assuta.co.il), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Hemodynamic adverse events (time frame: One year). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 16 Oct 2019.