CataractNCT04220255
Clinical Outcome at 5 Years After Implantation of the Liberty677MY Multifocal Intraocular Lens
An observational study of Cataract, run by Medicontur Medical Engineering Ltd at 1 site in Hungary.
Trial summary
The study will assess visual outcomes, light disturbances and patients' satisfaction after implantation with the Liberty677MY multifocal IOL, as well as protection of PCO development within 5 year follow-up. Read more about this study
- Who is it for?
- Ages 40 to 86 years
- Conditions the study is for
- Cataract
- What is being tested?
- Liberty677MY Multifocal IOL
- Type of treatment
- Medical device
- How many people
- 50 participants
- Where
- 1 siteHungary
- Study dates
- 1 Nov 2019to 31 Dec 2020
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 40 to 86 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: Pseudophakic patients implanted with Liberty 677MY in 2014-2015 during the study under the ethical approval: 059823/2014/OTIG
Who may be able to join
- pseudophakic patients implanted with Liberty 677MY in 2014-2015 during the study under the ethical approval: 059823/2014/OTIG
Who cannot join
- diabetic retinopathy
- iris neovascularisation
- serious intraoperative complications
- congenital eye abnormality
- glaucoma
- pseudoexfoliation syndrome
Show all 23Show fewer
- amblyopia
- uveitis
- long-term anti-inflammatory treatment
- AMD (advanced AMD)
- retinal detachment
- prior ocular surgery in personal medical history (except cataract surgery aiming the implantation of the multifocal IOL)
- previous laser treatment
- corneal diseases
- severe retinal diseases (dystrophy, degeneration)
- severe myopia (if required IOL power is lower than 10 D)
- inadequate visualization of the fundus on preoperative examination
- patients deemed by the clinical investigator because of any systemic disease.
- pregnancy
- eye trauma in medical history
- current use of systemic steroids or topical ocular medication
- preoperative smaller pupil size of 6 mm under topical mydriasis
- kappa angle >5°
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Clinical Outcome at 5 Years After Implantation of Medicontur Multifocal Intraocular Lens Liberty 677MY: Visual Outcomes, Patients' Satisfaction, YAG Capsulotomy Rate
The study will assess visual outcomes, light disturbances and patients' satisfaction after implantation with the Liberty677MY multifocal IOL, as well as protection of PCO development within 5 year follow-up.
Read the detailed description
The Liberty677MY multifocal IOL is designed for restoring near, intermediate and distance vision. The technology of Liberty 677MY is based on the elevated phase shift technology (patent pending). Previous evaluations showed the strength of studied IOL both in laboratory and clinical conditions.
Patients will be examined 5 years after implantation. The examination will include the measurement of the best corrected distance, intermediate and near visual acuity (assessed with Early Treatment Diabetic Retinopathy Study (ETDRS) charts), intraocular pressure (contact Goldman tonometry), biomicroscopic and fundocsopic examination, contrast sensitivity (CSV-1000), defocus curve, reading capability, pupilometry in different light conditions and PCO evaluation, Nd:YAG capsulotomy rate, photo-documentation of anterior segment. YAG capsulotomy will be indicated in case of posterior capsule opacification (PCO). The criteria for YAG capsulotomy will be visual acuity decreased 2 or more lines when using (ETDRS) charts. Details of all related and unrelated complications will be documented, including severity, time of onset, specific treatment and clinical outcome. The investigators will also record whether the capsulorhexis is on or partially off the optic.
- Conditions
- Cataract
- Being tested
- Liberty677MY Multifocal IOL
- Medical subject headings
- Cataract
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Liberty677MY Multifocal IOLDevice
multifocal intraocular lens (IOL)
What is being measured
The primary outcome is the main question the study is designed to answer.
Uncorrected Decimal VA (6 m)
Visual acuity (VA) was tested monocularly (each eye separately) and binocularly (both eyes together) 5 years after implantation, unaided at a distance of 6 meters (m) using Early Treatment Diabetic Retinopathy ( ETDRS) charts and assessed in logarithm of the minimum angle of resolution (LogMAR).
Measured: 5 years after implantation
Uncorrected Decimal VA (60 cm)
Visual acuity (VA) was tested monocularly (each eye separately) and binocularly (both eyes together) 5 years after implantation, unaided at a distance of 60 centimeters (cm) using ETDRS charts, assessed in LogMAR.
Measured: 5 years after implantation
Uncorrected Decimal VA (40 cm)
Visual acuity (VA) was tested monocularly (each eye separately) and binocularly (both eyes together) 5 years after implantation, unaided at a distance of 40 centimeters (cm) using ETDRS charts, assessed in LogMAR.
Measured: 5 years after implantation
Corrected Decimal VA (6 m)
Visual acuity (VA) was tested monocularly (each eye separately) and binocularly (both eyes together) 5 years after implantation, unaided at a distance of 6 meters (m) using ETDRS charts, assessed in LogMAR.
Measured: 5 years after implantation
Corrected Decimal VA (60 cm)
Visual acuity (VA) was tested monocularly (each eye separately) and binocularly (both eyes together) 5 years after implantation, unaided at a distance of 60 centimeters (cm) using ETDRS charts , assessed in LogMAR.
Measured: 5 years after implantation
Corrected Decimal VA (40 cm)
Visual acuity (VA) was tested monocularly (each eye separately) and binocularly (both eyes together) 5 years after implantation, unaided at a distance of 40 centimeters (cm) using ETDRS charts, assessed in LogMAR.
Measured: 5 years after implantation
Defocus Curve Profiles
Visual acuity measurement (assessed in logarithm of the minimum angle of resolution (LogMAR)) taken with different levels of optical defocus was tested monocularly (each eye separately) and binocularly (both eyes together).
Measured: 5 years after implantation
Contrast Sensitivity CSV-1000
Binocular Assessment of contrast sensitivity at threshold using the Contrast sensitivity vision (CSV) CSV-1000 in photopic and mesopic conditions with or without glare.
Measured: 5 years after implantation
Secondary outcomes (1)
Posterior capsule opacification (PCO) rate
Measured: 5 years after implantation
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted7 Jan 2020
- Study start1 Nov 2019
- Primary completion31 Dec 2020
- Study completion31 Dec 2020
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (1)Papers the sponsor has linked to this study.
- Other trials for CataractStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 50 participants (actual)
Sponsor and investigators
- Lead sponsor
- Medicontur Medical Engineering Ltd
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04220255
- Sponsor's protocol ID
- MC_Liberty677MY_HU_2019
- Status last verified
- May 2023
- First submitted
- 20 Dec 2019
- Last updated
- 1 Jun 2023
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Undecided
Publications
Gyory JF, Srinivasan S, Madar E, Balla L. Long-term performance of a diffractive-refractive trifocal IOL with centralized diffractive rings: 5-year prospective clinical trial. J Cataract Refract Surg. 2021 Oct 1;47(10):1258-1264. doi: 10.1097/j.jcrs.0000000000000670.
PubMed 33974369
Study at a glance
From the registry record, last updated by the sponsor on 1 Jun 2023. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Clinical Outcome at 5 Years After Implantation of Medicontur Multifocal Intraocular Lens Liberty 677MY: Visual Outcomes, Patients' Satisfaction, YAG Capsulotomy Rate
- ClinicalTrials.gov ID
- NCT04220255
- Acronym / sponsor ID
- MC_Liberty677MY_HU_2019
- Conditions
- Cataract
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 50 participants (actual)
- Lead sponsor
- Medicontur Medical Engineering LtdIndustry (pharma, biotech, devices)
- Study start
- 1 Nov 2019 (actual)
- Primary completion
- 31 Dec 2020 (actual)
- Study completion
- 31 Dec 2020 (actual)
- First posted
- 7 Jan 2020 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The study will assess visual outcomes, light disturbances and patients' satisfaction after implantation with the Liberty677MY multifocal IOL, as well as protection of PCO development within 5 year follow-up.
Detailed description
The Liberty677MY multifocal IOL is designed for restoring near, intermediate and distance vision. The technology of Liberty 677MY is based on the elevated phase shift technology (patent pending). Previous evaluations showed the strength of studied IOL both in laboratory and clinical conditions.
Patients will be examined 5 years after implantation. The examination will include the measurement of the best corrected distance, intermediate and near visual acuity (assessed with Early Treatment Diabetic Retinopathy Study (ETDRS) charts), intraocular pressure (contact Goldman tonometry), biomicroscopic and fundocsopic examination, contrast sensitivity (CSV-1000), defocus curve, reading capability, pupilometry in different light conditions and PCO evaluation, Nd:YAG capsulotomy rate, photo-documentation of anterior segment. YAG capsulotomy will be indicated in case of posterior capsule opacification (PCO). The criteria for YAG capsulotomy will be visual acuity decreased 2 or more lines when using (ETDRS) charts. Details of all related and unrelated complications will be documented, including severity, time of onset, specific treatment and clinical outcome. The investigators will also record whether the capsulorhexis is on or partially off the optic.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
Who may qualify
- Ages
- 40 to 86 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- Pseudophakic patients implanted with Liberty 677MY in 2014-2015 during the study under the ethical approval: 059823/2014/OTIG
Key inclusion criteria (1 listed)
- pseudophakic patients implanted with Liberty 677MY in 2014-2015 during the study under the ethical approval: 059823/2014/OTIG
Key exclusion criteria (23 listed)
- diabetic retinopathy
- iris neovascularisation
- serious intraoperative complications
- congenital eye abnormality
- glaucoma
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Liberty677MY Multifocal IOLmultifocal intraocular lens (IOL) | Device | – |
Primary outcome
Uncorrected Decimal VA (6 m)
Time frame: 5 years after implantation
Visual acuity (VA) was tested monocularly (each eye separately) and binocularly (both eyes together) 5 years after implantation, unaided at a distance of 6 meters (m) using Early Treatment Diabetic Retinopathy ( ETDRS) charts and assessed in logarithm of the minimum angle of resolution (LogMAR).
Uncorrected Decimal VA (60 cm)
Time frame: 5 years after implantation
Visual acuity (VA) was tested monocularly (each eye separately) and binocularly (both eyes together) 5 years after implantation, unaided at a distance of 60 centimeters (cm) using ETDRS charts, assessed in LogMAR.
Uncorrected Decimal VA (40 cm)
Time frame: 5 years after implantation
Visual acuity (VA) was tested monocularly (each eye separately) and binocularly (both eyes together) 5 years after implantation, unaided at a distance of 40 centimeters (cm) using ETDRS charts, assessed in LogMAR.
Corrected Decimal VA (6 m)
Time frame: 5 years after implantation
Visual acuity (VA) was tested monocularly (each eye separately) and binocularly (both eyes together) 5 years after implantation, unaided at a distance of 6 meters (m) using ETDRS charts, assessed in LogMAR.
Corrected Decimal VA (60 cm)
Time frame: 5 years after implantation
Visual acuity (VA) was tested monocularly (each eye separately) and binocularly (both eyes together) 5 years after implantation, unaided at a distance of 60 centimeters (cm) using ETDRS charts , assessed in LogMAR.
Corrected Decimal VA (40 cm)
Time frame: 5 years after implantation
Visual acuity (VA) was tested monocularly (each eye separately) and binocularly (both eyes together) 5 years after implantation, unaided at a distance of 40 centimeters (cm) using ETDRS charts, assessed in LogMAR.
Defocus Curve Profiles
Time frame: 5 years after implantation
Visual acuity measurement (assessed in logarithm of the minimum angle of resolution (LogMAR)) taken with different levels of optical defocus was tested monocularly (each eye separately) and binocularly (both eyes together).
Contrast Sensitivity CSV-1000
Time frame: 5 years after implantation
Binocular Assessment of contrast sensitivity at threshold using the Contrast sensitivity vision (CSV) CSV-1000 in photopic and mesopic conditions with or without glare.
1 secondary outcome
Posterior capsule opacification (PCO) rate
Time frame: 5 years after implantation
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 1 Jun 2023.
- Derived from this study: PubMed 33974369Gyory JF, Srinivasan S, Madar E, Balla L. Long-term performance of a diffractive-refractive trifocal IOL with centralized diffractive rings: 5-year prospective clinical trial. J Cataract Refract Surg. 2021 Oct 1;47(10):1258-1264. doi: 10.1097/j.jcrs.0000000000000670.
- Individual participant dataSharing planned: Undecided
Related trials for Cataract
Recruiting
Implementing AI-based Glaucoma Screening Within Federally Qualified Health Centers
Glaucoma, Ocular Hypertension
Not yet recruiting
Trial to Investigate the Safety and Effectiveness of the KI-362-US1 (YP2.2VM) Intraocular Lens (IOL) in Adult Participants for Correction of Aphakia Following Cataract Extraction
Aphakia, Postcataract
Not yet recruiting
Effects of Oxygen Cage Support During Cataract Surgery
Cataract
Active, not recruitingObservational study
Age-Related Eye Disease Study (AREDS) Follow-Up
Age-Related Macular Degeneration, Cataract
RecruitingObservational study
Objective Depth-of-Focus Changes During Light Adjustable Lens UV Adjustments
Light Adjustable Lens, Objective Depth of Focus
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Cataract, run by Medicontur Medical Engineering Ltd at 1 site in Hungary.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 23 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 1 Jun 2023. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Hungary. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Uncorrected Decimal VA (6 m) (time frame: 5 years after implantation). The study lists 8 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT04220255, which also lists 1 linked publication.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 1 Jun 2023.