AzTrials
AzTrials

Aortic Valve DiseaseNCT04223713

4D- Flow- MRI After Aortic Valve Surgery

A study testing TriRec and Aortic valve replacement in people with Aortic Valve Disease, run by Deutsches Herzzentrum Muenchen at 1 site in Germany.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

This randomized controlled trial was designed to analyze flow patterns in the ascending aorta with MRI after either Trileaflet reconstruction of the aortic valve with autologous pericardium (TriRec) or surgical valve replacement with biological prosthesis. Read more about this study

Who is it for?
Ages 50 years and older
Conditions the study is for
Aortic Valve Disease
What is being tested?
TriRec and Aortic valve replacement
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
30 participants
Where
1 siteGermany
Study dates
14 Jan 2020to Aug 2021
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 50 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age > 50 years
  • Documented symptomatic moderate or greater aortic stenosis or severe aortic insufficiency
  • Aortic annulus > 19 mm
  • Written informed consent of the patients.

Who cannot join

  • Concomitant intervention of the aortic root, ascending aorta or aortic arch
  • Concomitant valve surgery
  • Emergency surgery for any reason
  • Neurological events (i.e. stroke, TIA) within the previous 6 months
  • Coagulation disorders (including thrombocytopenia < 100.000/ml)
  • Porcelain aorta/severe calcification of the ascending aorta
Show all 12Show fewer
  • Active endocarditis or other active systemic infections
  • Participating in another trial that may influence the outcome of this trial
  • Pregnancy
  • Dual antiplatelet therapy
  • Previous cardiac surgery (excluding percutaneous procedures)
  • Contraindication for MRI- examinations

Trial locations and contacts

1 site in 1 country.

Anatol Prinzing, MD contact

+49891218 ext. 2777

prinzing@dhm.mhn.de

Germany1 site, 1 recruiting
  • Deutsches Herzzentrum Muenchen, Department of Cardiovascular Surgery

    Munich, 80636

    Anatol Prinzing, MD

    Recruiting

Other trials in Germany

About this study

Official title: Changes of Aortic Flow Patterns Detected by 4D- Flow- MRI After Trileaflet Reconstruction of the Aortic Valve With Autologous Pericardium Compared to Prosthetic Valve Replacement With Biological Prosthesis

This randomized controlled trial was designed to analyze flow patterns in the ascending aorta with MRI after either Trileaflet reconstruction of the aortic valve with autologous pericardium (TriRec) or surgical valve replacement with biological prosthesis. The hypothesis is that after TriRec procedure more physiological flow patterns will be observed, compared to biological valve prosthesis.

Read the detailed description

Trileaflet reconstruction of the aortic valve with autologous pericardium (TriRec) is a new treatment option for diseased aortic valves and offers benefits compared to conventional valve replacement. At the moment no prospective randomized trials evaluating the role of the TriRec procedure are available and factors contributing to long- term durability are unknown.

The investigators want to examine aortic flow patterns with 4D- Flow- Magnetic Resonance Imaging (MRI) in patients after the TriRec procedure or biological prosthetic valve replacement in a prospective randomized trial. Flow patterns in the ascending aorta, examined with 4D- Flow- MRI, show nearly laminar flow patterns and no outflow obstruction in healthy subjects with tricuspid aortic valves. In contrast, helical flow patterns, turbulences and increased flow velocities are observed in diseased valves and also after valve replacement with mechanical or biological prostheses. These helical flow patterns seem to influence aortic wall remodeling and may contribute to structural valve dysfunction of biological prosthesis.

The investigators hypothesize that after TriRec procedure more physiological flow patterns will be observed, compared to biological valve prosthesis. The results can contribute to understand mechanisms for long- term performance of this technique and determine the role of this novel technique for treatment of aortic valve disease.

Being tested
TriRec, Aortic valve replacement
Keywords
aortic stenosis, aortic regurgitation, Trileaflet reconstruction of the aortic valve, Biological aortic valve prosthesis, aortic flow patterns, MRI
Medical subject headings
Aortic Valve Disease, Aortic Valve Stenosis, Aortic Valve Insufficiency

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • TriRecProcedure or surgery

    Trileaflet Reconstruction of the Aortic Valve

  • Aortic valve replacementProcedure or surgery

    Biological Prosthesis, Device: Edwards Perimount

Study groups in NCT04223713
Study groupRoleWhat they receive
TriRecExperimentalTrileaflet Reconstruction of the Aortic Valve
Receives: Procedure: TriRec
Aortic valve replacementExperimentalBiological prosthesis, Device: Edwards Perimount
Receives: Procedure: Aortic valve replacement

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Flow velocity in the ascending aorta (m/s)

    Flow velocity in meters/ second in the ascending aorta in patients receiving either TriRec or biological prosthetic valve replacement measured by 4D- Flow- MRI.

    Measured: Day 4-7 post surgery

Secondary outcomes (11)
  1. Flow vortices

    Flow vortices: defined as rotating particles around a point within the vessel with the rotational direction diverting > 90° from the physiological flow direction.

    Measured: Day 4-7 post surgery

  2. Flow helicality

    Blood revolving around an axis parallel to the main blood flow generating a corkscrew like figure

    Measured: Day 4-7 post surgery

  3. Systolic eccentricity

    Localization of the main blood flow vector (central, little, severe eccentricity).

    Measured: Day 4-7 post surgery

  4. Flow patterns in the left ventricular outflow tract.

    Flow patterns in the left ventricular outflow tract.

    Measured: Day 4-7 post surgery

  5. Effective orifice area (4D-Flow-MRI)

    Effective orifice area (cm2) of the reconstructed or replaced valve (4D- Flow- MRI)

    Measured: Day 4-7 post surgery

  6. Effective orifice area (TTE)

    Effective orifice area (cm2) of the reconstructed or replaced valve (transthoracic echocardiography (TTE)

    Measured: Day 4-7 post surgery

  7. Peak- and mean pressure gradients (mmHg, TTE)

    Peak- and mean pressure gradients (mmHg, TTE)

    Measured: Day 4-7 post surgery

  8. Left- ventricular diameters (mm, TTE)

    Left- ventricular diameters (mm, TTE)

    Measured: Day 4-7 post surgery

  9. Left- ventricular ejection fraction (%, TTE)

    Left- ventricular ejection fraction (%, TTE)

    Measured: Day 4-7 post surgery

  10. Quantification of aortic regurgitation (MRI)

    Quantification of aortic regurgitation (MRI)

    Measured: Day 4-7 post surgery

  11. Quantification of aortic regurgitation (TTE)

    Quantification of aortic regurgitation (TTE)

    Measured: Day 4-7 post surgery

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted10 Jan 2020
  2. Study start14 Jan 2020
  3. Primary completionAug 2021 (estimated)
  4. Study completionAug 2021 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
30 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04223713
Sponsor's protocol ID
77/19-S
Status last verified
Jan 2021
First submitted
29 Nov 2019
Last updated
4 Mar 2021
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

A study testing TriRec and Aortic valve replacement in people with Aortic Valve Disease, run by Deutsches Herzzentrum Muenchen at 1 site in Germany.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 12 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 4 Mar 2021. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Anatol Prinzing, MD (+49891218 ext. 2777, prinzing@dhm.mhn.de), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Flow velocity in the ascending aorta (m/s) (time frame: Day 4-7 post surgery). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 4 Mar 2021.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in