Abdominal Aortic AneurysmAAA-SHAPENCT04227054
Abdominal Aortic Aneurysm Sac Healing and Prevention of Endoleaks
A study testing IMPEDE-FX Embolization Plug in people with Abdominal Aortic Aneurysm, run by Shape Memory Medical, Inc. at 2 sites in New Zealand.
Trial summary
To determine the safety and efficacy of IMPEDE-FX Embolization Plug and/or IMPEDE-FX Rapid Fill to fill an abdominal aortic aneurysm (AAA) sac outside of an endovascular aneurysm repair (EVAR) stent graft. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Abdominal Aortic Aneurysm
- What is being tested?
- IMPEDE-FX Embolization Plug
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 15 participants
- Where
- 2 sitesNew Zealand
- Study dates
- 9 Sep 2020to 30 Aug 2028
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- ≥18 years of age
- A candidate for elective EVAR of an infrarenal aortic aneurysm ≥5.5 cm in diameter in men and ≥5.0 cm in women
Who cannot join
- An inability to provide informed consent
- Enrolled in another clinical study
- Concomitant iliac artery ectasia or aneurysm (common iliac artery diameter >24 mm)
- Patent AAA sac feeding vessels (within the sac) >4 mm in diameter
- Volume of AAA sac to be filled after stent graft placement <30 mL or >135 mL, based on pre-procedure CTA (i.e. aortic flow volume exclusive of stent graft volume)
- Use of aortic stent grafts other than the Gore Excluder AAA Endoprosthesis, Cook Zenith Flex AAA Endovascular Graft, Medtronic Endurant II Stent Graft, or Endologix Ovation Alto Abdominal Stent Graft System to treat the AAA
Show all 27Show fewer
- Planned use of the chosen stent graft outside its instructions for use (IFU)
- Planned use of fenestrated or chimney stent grafts
- Study participants in which stent graft placement is abandoned for any reason, and/or in which the investigator decides, during the course of the stent graft placement, that the study procedure may not be appropriate
- Planned use of embolic devices other than the investigational product to embolize the AAA sac
- Vascular disease and/or anatomy that preclude the safe access and positioning of a catheter to deliver the investigational product into the AAA sac
- Ruptured, leaking, or mycotic (infected) aneurysm
- Aneurysmal disease of the descending thoracic aorta
- Coagulopathy or uncontrolled bleeding disorder
- Long-term (>6 months prior to the procedure) use of direct oral anticoagulant or any vitamin K antagonist anticoagulant use
- Serum creatinine level >2.5 mg/dL;
- Cerebrovascular accident within 3 months prior to the procedure
- Myocardial infarction and/or major heart surgery within 3 months prior to the procedure
- Atrial fibrillation that is not well rate controlled
- Unable or unwilling to comply with study follow-up requirements
- Life expectancy of <2 years post-procedure
- Known hypersensitivity or contraindication to platinum, iridium, or polyurethane
- A condition that inhibits radiographic visualization during the implantation procedure
- History of allergy to contrast medium that cannot be managed medically
- Uncontrolled co-morbid medical condition, including mental health issues, that would adversely affect participation in the study
- Pregnant or a lactating female. For females of child-bearing potential, based on a positive pregnancy test within 7 days prior to the procedure or refusal to use a medically accepted method of birth control for the duration of the study
- Prisoner or member of other vulnerable population.
Trial locations and contacts
2 sites in 1 country.
New Zealand2 sites
Auckland City Hospital
Auckland, Auckland, 1023
Waikato Hospital
Hamilton, 3240
About this study
Official title: Abdominal Aortic Aneurysm Sac Healing and Prevention of Endoleaks - A Prospective Single Center Safety Study
To determine the safety and efficacy of IMPEDE-FX Embolization Plug and/or IMPEDE-FX Rapid Fill to fill an abdominal aortic aneurysm (AAA) sac outside of an endovascular aneurysm repair (EVAR) stent graft.
- Conditions
- Abdominal Aortic Aneurysm
- Being tested
- IMPEDE-FX Embolization Plug
- Medical subject headings
- Aortic Aneurysm, Abdominal
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
IMPEDE-FX Embolization PlugDevice
Fill an abdominal aortic aneurysm (AAA) sac outside of an endovascular aneurysm repair (EVAR) stent graft
| Study group | Role | What they receive |
|---|---|---|
| Intervention | Experimental | Not described Receives: Device: IMPEDE-FX Embolization Plug |
What is being measured
The primary outcome is the main question the study is designed to answer.
Incidence of related major adverse events (MAEs)
Incidence of related major adverse events (MAEs)
Measured: 30 days post-procedure
Efficacy - Technical Success
Technical success, defined as filling of the residual flow lumen of the AAA sac with investigational products
Measured: Immediately after the intervention
Secondary outcomes (7)
Incidence of related major adverse events (MAEs)
Incidence of related major adverse events (MAEs)
Measured: 5 years post-procedure
Incidence of related serious adverse events (SAEs)
Incidence of related serious adverse events (SAEs)
Measured: 5 years post-procedure
Efficacy - Type II endoleaks
Incidence of type II endoleaks
Measured: 5 years post-procedure
Efficacy - Type I and type III endoleaks
Incidence of type I and type III endoleaks
Measured: 5 years post-procedure
Efficacy - AAA sac diameter/volume
Change in AAA sac diameter/volume
Measured: 5 years post-procedure
Efficacy - Open repair
Rate of conversion to open AAA repair
Measured: 5 years post-procedure
Efficacy - Reinterventions
Rate of other reinterventions related to the AAA sac growth and/or complications
Measured: 5 years post-procedure
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted13 Jan 2020
- Study start9 Sep 2020
- Primary completion30 Aug 2023
- Study completion30 Aug 2028 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Abdominal Aortic AneurysmStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 15 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Shape Memory Medical, Inc.
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04227054
- Sponsor's protocol ID
- CRD1015
- Acronym
- AAA-SHAPE
- Status last verified
- Dec 2025
- First submitted
- 10 Jan 2020
- Last updated
- 22 Dec 2025
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 22 Dec 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Abdominal Aortic Aneurysm Sac Healing and Prevention of Endoleaks - A Prospective Single Center Safety Study
- ClinicalTrials.gov ID
- NCT04227054
- Acronym / sponsor ID
- AAA-SHAPE / CRD1015
- Conditions
- Abdominal Aortic Aneurysm
- Study type
- Interventional
- Recruitment status
- Active, not recruiting
- Enrolment
- 15 participants (estimated)
- Lead sponsor
- Shape Memory Medical, Inc.Industry (pharma, biotech, devices)
- Study start
- 9 Sep 2020 (actual)
- Primary completion
- 30 Aug 2023 (actual)
- Study completion
- 30 Aug 2028 (estimated)
- First posted
- 13 Jan 2020 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
To determine the safety and efficacy of IMPEDE-FX Embolization Plug and/or IMPEDE-FX Rapid Fill to fill an abdominal aortic aneurysm (AAA) sac outside of an endovascular aneurysm repair (EVAR) stent graft.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Intervention | Experimental | Device: IMPEDE-FX Embolization Plug |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (2 listed)
- ≥18 years of age
- A candidate for elective EVAR of an infrarenal aortic aneurysm ≥5.5 cm in diameter in men and ≥5.0 cm in women
Key exclusion criteria (27 listed)
- An inability to provide informed consent
- Enrolled in another clinical study
- Concomitant iliac artery ectasia or aneurysm (common iliac artery diameter >24 mm)
- Patent AAA sac feeding vessels (within the sac) >4 mm in diameter
- Volume of AAA sac to be filled after stent graft placement <30 mL or >135 mL, based on pre-procedure CTA (i.e. aortic flow volume exclusive of stent graft volume)
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| IMPEDE-FX Embolization PlugFill an abdominal aortic aneurysm (AAA) sac outside of an endovascular aneurysm repair (EVAR) stent graft | Device | Intervention |
Primary outcome
Incidence of related major adverse events (MAEs)
Time frame: 30 days post-procedure
Incidence of related major adverse events (MAEs)
Efficacy - Technical Success
Time frame: Immediately after the intervention
Technical success, defined as filling of the residual flow lumen of the AAA sac with investigational products
7 secondary outcomes
Incidence of related major adverse events (MAEs)
Time frame: 5 years post-procedure
Incidence of related serious adverse events (SAEs)
Time frame: 5 years post-procedure
Efficacy - Type II endoleaks
Time frame: 5 years post-procedure
Efficacy - Type I and type III endoleaks
Time frame: 5 years post-procedure
Efficacy - AAA sac diameter/volume
Time frame: 5 years post-procedure
Efficacy - Open repair
Time frame: 5 years post-procedure
Efficacy - Reinterventions
Time frame: 5 years post-procedure
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 22 Dec 2025.
- Individual participant dataSharing planned: No
Related trials for Abdominal Aortic Aneurysm
Not yet recruitingObservational study
Pilot Study on the Effectiveness and Safety of OPTILENE® SILVER MESH ELASTIC in Prevention of Surgical Site Infection (SSI) and Incisional Hernia (IH)
Abdominal Aortic Aneurysm, Morbid Obesity
RecruitingPhase 4
Effect of Remimazolam Versus Propofol Total Intravenous Anesthesia on Intraoperative Hemodynamic Stability in Patients Undergoing Thoracic or Abdominal Endovascular Aortic Repair
Aortic Aneurysm, Thoracoabdominal, Aortic Aneurysm, Abdominal
Not yet recruitingObservational study
Aortic Size and Height Indices in Abdominal Aortic Aneurysms
Abdominal Aortic Aneurysm, Abdominal Aortic Aneurysm, Ruptured
Not yet recruitingObservational study
Real-World Data Collection of GORE Devices Used In the Endovascular Treatment of Aortic Aneurysms Which Incorporate Visceral Arteries.
Complex Aortic Aneurysms, Thoracoabdominal Aneurysm
Enrolling by invitation
Endovascular Treatment of Thoracic Aortic Disease
Thoracic Aortic Aneurysms, Dissecting, Aneurysm
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
2 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing IMPEDE-FX Embolization Plug in people with Abdominal Aortic Aneurysm, run by Shape Memory Medical, Inc. at 2 sites in New Zealand.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 27 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: under way, not looking for participants, as of the sponsor's last update on 22 Dec 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 2 sites in New Zealand. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Incidence of related major adverse events (MAEs) (time frame: 30 days post-procedure). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 22 Dec 2025.