Cardiac ArrhythmiaNCT04227119

Hemodynamics Measurement in Radiofrequency Catheter Ablation

A study testing Irrigated ablation catheter and Balloon tipped PA catheter in people with Cardiac Arrhythmia, run by Emory University at 2 sites in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This study will occur in patients undergoing routine cardiac ablation of his/her arrhythmia with planned use of an irrigated ablation catheter. The main objective of this study is to take intracardiac pressure measurements and pressure waveforms with both a "gold standard" balloon tipped pulmonary artery catheter… Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Cardiac Arrhythmia
What is being tested?
Irrigated ablation catheter and Balloon tipped PA catheter
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
11 participants
Where
2 sitesUnited States
Study dates
23 Jan 2020to 18 May 2020
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • patient undergoing routine cardiac ablation of his/her arrhythmia with planned use of an irrigated ablation catheter

Who cannot join

  • inability to provide informed consent

Trial locations and contacts

2 sites in 1 country.

United States2 sites
  • Emory Clinic

    Atlanta, Georgia, 30322

  • Emory University Hospital

    Atlanta, Georgia, 30322

Other trials in United States

About this study

This study will occur in patients undergoing routine cardiac ablation of his/her arrhythmia with planned use of an irrigated ablation catheter. The main objective of this study is to take intracardiac pressure measurements and pressure waveforms with both a "gold standard" balloon tipped pulmonary artery catheter placed for this study and an irrigated ablation catheter placed as standard of care for the procedure.

Read the detailed description

Measuring internal heart pressures allows for the assessment and diagnosis of a variety of cardiac conditions which are commonly found in patients undergoing catheter ablation, including congestive heart failure, diastolic dysfunction, and valvular heart disease. Currently it is unknown if taking pressure measurements with the ablation catheter is accurate and it is not standard practice to insert the additional 'gold standard' pressure sensing catheter. Catheter ablation of cardiac arrhythmia is performed to offer symptomatic relief from a variety of atrial, ventricular and atrio-ventricular rhythms. Irrigated ablation catheters are commonly used for ablation of arrhythmias arising from the left heart and coronary sinus. These catheters contain internal channels allowing for infusion of an external fluid directly to the tip of the catheter, where the fluid is sprayed through numerous end holes allowing for cooling of the catheter ablation tip.

Fluid filled catheters are also the primary tool utilized to assess intravascular and intracardiac pressures and hemodynamics in the cardiac catheterization suite and intensive care unit. However, the fluid filled catheters commonly used for these assessments are single lumen with a single end hole and generally have a larger minimal diameters compared to the ablation catheter. "Dampening" of pressure waveforms are observed in smaller diameter catheters and may lead to underestimation of peak pressure and overestimation of the nadir pressure gradient. It is unknown if transduction of pressures from the tip of an irrigated ablation catheter will yield equivalent results compared to use of a single 5 French (5F) sized lumen catheter.

This study will seek to enroll patients already scheduled to have a cardiac ablation for a clinical arrhythmia at Emory University Hospital. After completion of the standard ablation, the ablation catheter will be positioned in the heart and pressures will be measured. Next, a standard pressure sensing catheter will be positioned in the same area in the heart and pressures will be measured. The pressure values for each heart chamber assessed will be compared between the catheters. The purpose of this study is to test the hypothesis that transduction of intracardiac pressures using an irrigated ablation catheter placed as standard of care for the ablation procedure is equivalent to transduction of pressures using a standard 5F balloon tipped PA catheter placed only for this research study.

Being tested
Irrigated ablation catheter, Balloon tipped PA catheter
Keywords
Cardiology, Electrophysiology
Medical subject headings
Arrhythmias, Cardiac

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Irrigated ablation catheterDevice

    After completion of ablation, the ablation catheter will be serially positioned in the cardiac chambers (either the left or right side of the heart). The stop cock will be turned to the pressure transducer and waveforms will be stored corresponding to each chamber.

  • Balloon tipped PA catheterDevice

    After removal of the irrigated ablation catheter, a 5F balloon tipped PA catheter which will be positioned under fluoroscopic guidance in each previously evaluated chamber and the chambers will be measured again.

Study groups in NCT04227119
Study groupRoleWhat they receive
Irrigated ablation catheter and 5F balloon tipped PA catheterExperimentalParticipants undergoing cardiac ablation will have cardiac pressures measured with an irrigated ablation catheter (standard protocol for this procedure) and a 5F balloon tipped pulmonary artery (PA) catheter (for study purposes only).
Receives: Device: Irrigated ablation catheter; Device: Balloon tipped PA catheter

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Systolic Pressure Value

    The systolic pressure values for atrium and ventricle heart chambers are presented for the irrigated ablation catheter derived measurements and the balloon tipped PA catheter measurements.

    Measured: Day 1 (during procedure)

  2. Diastolic Pressure Value

    The diastolic pressure values for ventricle heart chambers are presented for the irrigated ablation catheter derived measurements and the balloon tipped PA catheter measurements.

    Measured: Day 1 (during procedure)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted13 Jan 2020
  2. Study start23 Jan 2020
  3. Primary completion18 May 2020
  4. Study completion18 May 2020

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
11 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04227119
Sponsor's protocol ID
IRB00116832
Status last verified
May 2021
First submitted
10 Jan 2020
Last updated
14 Jun 2021
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Irrigated ablation catheter and Balloon tipped PA catheter in people with Cardiac Arrhythmia, run by Emory University at 2 sites in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 14 Jun 2021. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 2 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 14 Jun 2021). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Systolic Pressure Value (time frame: Day 1 (during procedure)). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 14 Jun 2021.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in