AzTrials
AzTrials

Diabetes Mellitus, Type 2NCT04261738

Effects of HBO on Glucose in Patients With DM

A study testing Hyperbaric Oxygen in people with Diabetes Mellitus, Type 2 and Diabetes Mellitus, Type 1, run by Legacy Health System at 1 site in United States.

Terminated

Stopped early. The study ended before it was planned to and will not resume.

Official record
Search all trials

Trial summary

The purpose of this Research Study is: 1. To determine the reliability and performance of the Dexcom G6® continuous glucose monitoring (CGM) system in patients with diabetes undergoing hyperbaric oxygen (HBO2) exposure. The study-specific blood glucose meter and CGM system are approved by the FDA (U.S. Read more about this study

Who is it for?
Ages 18 years and olderHealthy volunteers can take part
What is being tested?
Hyperbaric Oxygen
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
6 participants
Where
1 siteUnited States
Study dates
2 Sep 2022to 4 Sep 2025
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Diagnosis of type 1 or type 2 diabetes
  • Willing to have 2 subcutaneous glucose monitors for 10 days
  • Willing to be NPO after midnight on the day of the study session
  • Willing to come to the hyperbaric facility on successive days (one control session and one hyperbaric treatment), spending approximately 3 hours in the facility on each day of testing
  • Willing to undergo multiple fingersticks on the days of testing
  • Willing to have a peripheral intravenous catheter placed for blood sampling
  • Willing to perform four daily fingerstick blood glucose checks throughout the study period

Who cannot join

  • Contraindication to HBO2 as determined by the study investigator (e.g., pregnancy)
  • Previous treatment with HBO2 within 30 days of enrollment
  • Current use of CGM is not an exclusion, but participants must use study equipment during the study
  • Current use of an insulin pump
  • Known allergy to medical-grade adhesives
  • Extensive skin changes/disease that preclude wearing the sensor on normal skin (e.g. extensive psoriasis, recent burns or severe sunburn, extensive eczema, extensive scarring, extensive tattoos, dermatitis herpetiformis)

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Legacy Emanuel Medical Center

    Portland, Oregon, 97227

Other trials in United States

About this study

Official title: Effects of Hyperbaric Oxygen Therapy on Glucose Homeostasis in Patients Living With Diabetes Mellitus

The purpose of this Research Study is:

  1. To determine the reliability and performance of the Dexcom G6® continuous glucose monitoring (CGM) system in patients with diabetes undergoing hyperbaric oxygen (HBO2) exposure. The study-specific blood glucose meter and CGM system are approved by the FDA (U.S. Food and Drug Administration).
  2. To determine whether HBO2 exposure causes blood glucose to drop as a result of the treatment.
  3. To determine whether HBO2 causes a change in blood glucagon (a hormone that raises blood glucose).

Investigators will be comparing changes in blood glucose and glucagon in volunteers with diabetes who will be exposed to a single hyperbaric oxygen treatment (pressurization to 2.4 atmospheres absolute for 90 minutes) to a control period of 2 hours where volunteers will simulate a hyperbaric treatment while sitting in an examination room breathing room air at sea level pressure. Investigators will be measuring blood glucose with a variety of devices including a continuous glucose monitor, two point-of-care glucometers, and the hospital inpatient laboratory measurement of venous blood.

Read the detailed description

The purpose of this Research Study is to determine whether the Dexcom G6® continuous glucose monitoring (CGM) system accurately estimates blood glucose in diabetic patients undergoing hyperbaric oxygen (HBO2) exposure. The study-specific CGM system is approved by the FDA (U.S. Food and Drug Administration).

Subjects will have the Dexcom CGM inserted underneath the skin of their abdomen. This is done in the office. It is secured to the skin by use of an adhesive patch. The sensor measures glucose levels just underneath the skin. A transmitter is fastened on top of the sensor and sends this information wirelessly to a receiver or compatible smart device. Study participants will also have second sensor inserted in the subcutaneous tissue on the back of the arm as a backup in case of data loss. The subjects will wear the sensors for at least 48 hours and then return to the Hyperbaric Medicine Clinic.

At the Hyperbaric Medicine Clinic, study staff will check the CGM system to make sure it has been working properly. The first 2-hour session will be a control where participants will sit quietly (as they would in the hyperbaric chamber) and will not be allowed to consume carbohydrates unless directed to by the hyperbaric department hypoglycemia protocol. The following day for the HBO2 session, subjects will be fitted for an oxygen hood and given a standard HBO2 treatment. Investigators will obtain concurrent transcutaneous oximetry measurements (TCOM) attached no farther than 3 cm from the commercial CGM on the abdomen to measure tissue oxygenation in the region of the CGM only during HBO2 exposure.

The hyperbaric oxygen therapy chamber can accommodate 12 patients at a time. Study subjects could be in the chamber along with regularly scheduled patients. In the chamber the pressure will increase to approximately 2-1/2 times normal atmospheric pressure (2.4 atmospheres absolute [ATA]). Once they reach the treatment pressure, subjects will breathe oxygen by placing the hood over their head and securing it in place. They will breathe oxygen for a 30-minute period, and then take the hood off for 5 minutes for an "air break." They will have a total of three 30-minute oxygen periods and two 5-minute air breaks. A subject will be in the hyperbaric chamber for approximately 2 hours.

Blood sampling will be identical for both the control and HBO2 exposure days. Subjects will have a peripheral intravenous (IV) catheter placed and a total of 12 samples collected to measure venous blood glucose (12 timepoints), glucagon levels (3 timepoints) and HgA1c, (one time). A RN or MD will be inside the chamber to monitor the subjects and to obtain the IV blood samples. Because CGMs have not been established to be reliable under HBO2 conditions in patients with DM, the protocol will collect Point-of-Care (POC) glucose measurements using the hospital's standard glucometer (Nova Biomedical, Waltham, MA) and the AccuChek Inform II POC glucometer (Roche Diagnostics, Indianapolis, IN) at each testing point. This will be done using a lancet to pierce the skin of the fingertip to get a drop of blood.

Subjects in both groups will also be required to perform home glucose monitoring (4 times per day) and record mealtimes and the time of any medications taken throughout the study period.

Subjects will return to the clinic on Day 10. The CGM sensor will be removed and the transmitter and display device collected by staff. Removed sensors will be returned to the manufacturer for analysis. That is the end of the subject's study participation.

Being tested
Hyperbaric Oxygen
Keywords
hyperbaric oxygen, continuous glucose monitor, hbo, cgm
Medical subject headings
Diabetes Mellitus, Type 2, Diabetes Mellitus, Type 1

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Hyperbaric OxygenDevice

    Also called HBOT, HBO2

    Volunteers will be given a standard hyperbaric oxygen treatment (2.4 ATA x 90 minutes)

Study groups in NCT04261738
Study groupRoleWhat they receive
ControlNo interventionThe first 2-hour session will be a control where participants will sit quietly (as they would in the hyperbaric chamber) and will not be allowed to consume carbohydrates unless directed to by the hyperbaric department hypoglycemia protocol.
Hyperbaric OxygenExperimentalThe following day for the HBO2 session, subjects will be fitted for an oxygen hood and given a standard HBO2 treatment. In the chamber the pressure will increase to approximately 2-1/2 times normal atmospheric pressure (2.4 atmospheres absolute [ATA]). Once they reach the treatment pressure, subjects will breathe oxygen by placing the hood over their head and securing it in place. They will breathe oxygen for a 30-minute period, and then take the hood off for 5 minutes for an "air break." They will have a total of three 30-minute oxygen periods and two 5-minute air breaks. A subject will be in the hyperbaric chamber for approximately 2 hours.
Receives: Device: Hyperbaric Oxygen

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. CGM Reading

    Estimated glucose value from the continuous glucose monitor

    Measured: 10 days

  2. CGM Reading from Data Logger

    Estimated glucose value from the data logger

    Measured: 10 days

  3. Fingerstick point of care glucose

    Estimated glucose value from fingersticks during control and HBOT arms

    Measured: 2 days

  4. Fingerstick point of care glucose

    Estimated glucose value from fingersticks during the length of the study (4 times/day)

    Measured: 10 days

  5. Hospital laboratory glucose

    Estimated glucose value from venous blood during control and HBOT arms

    Measured: 2 days

  6. Hba1c

    Baseline Hba1c

    Measured: One time only on day 3 of study

Secondary outcomes (1)
  1. Glucagon

    We will determine whether HBOT has any effect on glucagon levels on control and HBOT arm

    Measured: 2 days

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted10 Feb 2020
  2. Study start2 Sep 2022
  3. Primary completion4 Sep 2025
  4. Study completion4 Sep 2025

Why it stopped: Facility closure, awaiting relocation

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Non-randomised
Intervention model
Sequential
Model description
Control exposure followed by Hyperbaric Oxygen exposure
Masking
None (open label)
Enrolment
6 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04261738
Sponsor's protocol ID
HB-002
Status last verified
May 2024
First submitted
6 Feb 2020
Last updated
26 Aug 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Publications

  • Huang E, Demirel S, Bliss C, Savaser D, Castle JR. Reliability of the Dexcom G6 Continuous Glucose Monitor During Hyperbaric Oxygen Exposure. Diabetes Technol Ther. 2020 May;22(5):360-366. doi: 10.1089/dia.2019.0390. Epub 2020 Feb 6.

    PubMed 31916854

Questions about this trial

What is this clinical trial studying?

A study testing Hyperbaric Oxygen in people with Diabetes Mellitus, Type 2 and Diabetes Mellitus, Type 1, run by Legacy Health System at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 7 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: stopped early, as of the sponsor's last update on 26 Aug 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study was stopped early (reason given: Facility closure, awaiting relocation). Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

CGM Reading (time frame: 10 days). The study lists 6 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04261738, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 26 Aug 2026; AzTrials last refreshed its copy on 7 Nov 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in