AzTrials
AzTrials

Bronchopulmonary DysplasiaNCT04274192

Effect of Synchronized vs. Continuous HFNC Using NAVA on WOB in Infants With BPD

A study testing Synchronized HFNC at 6 liters per minute (LPM), Continuous HFNC at 6 liters per minute (LPM) and Synchronized HFNC at 8 liters per minute (LPM) in people with Bronchopulmonary Dysplasia, run by University of Arkansas at 1 site in United States.

Terminated

Stopped early. The study ended before it was planned to and will not resume.

Official record
Search all trials

Trial summary

Patients will be randomized to begin the study with either NAVA-synchronized or continuous HFNC. Each patient will receive two 15-minute trials at different levels of continuous HFNC and two 15-minute trials at corresponding levels of synchronized HFNC. Read more about this study

Who is it for?
Ages 28 days to 1 year
Conditions the study is for
Bronchopulmonary Dysplasia
What is being tested?
Synchronized HFNC at 6 liters per minute (LPM), Continuous HFNC at 6 liters per minute (LPM) and Synchronized HFNC at 8 liters per minute (LPM)
Could I receive a placebo?
No, everyone receives an active treatment
How many people
1 participants
Where
1 siteUnited States
Study dates
9 Dec 2020to 28 Jan 2021
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 28 days to 1 year
  • All sexes
  • No healthy volunteers
  • Child

Who may be able to join

  • Chronological age greater than 28 days
  • Gestational age at birth less than 32 weeks and 6 days
  • Diagnosis of BPD (supplemental oxygen requirement for greater than or equal to 28 days)
  • Currently receiving noninvasive ventilation support (NIV NAVA, NIPPV, nCPAP, HFNC)

Who cannot join

  • Major congenital anomalies of the heart and lungs
  • Post menstrual age greater than 50 weeks 0 days
  • Oxygen requirement greater than 40%

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Arkansas Children's Hospital

    Little Rock, Arkansas, 72202

Other trials in United States

About this study

Official title: Effect of Synchronized vs. Continuous High Flow Nasal Cannula Using Neurally Adjusted Ventilatory Assist on Work of Breathing in Infants With Bronchopulmonary Dysplasia

Patients will be randomized to begin the study with either NAVA-synchronized or continuous HFNC. Each patient will receive two 15-minute trials at different levels of continuous HFNC and two 15-minute trials at corresponding levels of synchronized HFNC. In synchronized HFNC, using the NIV NAVA mode on the ventilator each subject will receive a constant minimum flow, but with each neurally triggered breath (as measured with an Edi catheter), an additional flow will be given to the patient. This differs from continuous HFNC in which the subject receives a constant flow without variation. Subjects will be observed during the entirety of these trials. Values for the primary and secondary outcomes will be monitored, recorded, and calculated.

Read the detailed description

Prior to the study period each subject will have the following monitoring equipment placed (if not already present): Edi catheter, transcutaneous monitor (TCM4, Radiometer, Brea, CA, USA) to measure CO2 and O2 levels, pulse oximeter probe (MasimoSET, Irvine, CA, USA) to measure oxygen saturations and heart rate, and RIP bands (SleepSense, MFI Medical, San Diego, CA, USA) around the chest and abdomen to measure breathing movements and relative tidal volume.

Each subject will be randomized on the day the study is to occur to begin with either NAVA-synchronized or continuous HFNC before crossing over to the other mode to serve as his/her own control. The same RAM cannula will be used in both study arms and will provide a leak of 60-80% as recommended by the product manual. The delivery of high flow during both synchronized and continuous HFNC will be given at two commonly provided levels of high flow: 6 LPM and 8 LPM, given in the same order in each mode (6 LPM then 8 LPM). Each subject will receive 15-minute trials of each mode-level combination, for a total of four trials. During each trial, the first 10 minutes will be used for stabilization, and the last 5 minutes will be used for data collection, as has been done in previous trials. Thus, the mode-level combinations of the trials will be as follows: for infants randomized to begin with synchronized support: synchronized-6 LPM, synchronized-8 LPM, unsynchronized-6 LPM, unsynchronized-8 LPM. For infants randomized to begin with unsynchronized support: unsynchronized-6 LPM, unsynchronized-8 LPM, synchronized-6 LPM, unsynchronized-8 LPM.

The flows described in the NAVA-synchronized trials refer to the peak flow provided during inspiration. A baseline flow rate of 2 LPM will be provided expiration in these trials (using the PEEP setting corresponding to the appropriate flow rate). During the unsynchronized trials, the continuous high flow rate will be provided (as is common practice with the use of HFNC). During the NAVA-synchronized HFNC trials, the Edi trigger will be set to 0.5 microvolts, apnea time to 5 seconds, back up rate to 10 breaths per minute, and backup pressure settings will be set to provide an estimated peak flow of 6 or 8 LPM according to the designated trial (again, using the pressure setting corresponding to the appropriate flow rate).

During NAVA-synchronized HFNC, the NIV NAVA mode will be set in such a way that synchronized HFNC will be provided. A minimal end-expiratory flow of 2 LPM will be provided using the positive end expiratory pressure (PEEP) setting in the NIV NAVA mode on the ventilator. The PEEP setting corresponding to 2 LPM via the pneumotachograph will be used. In order to deliver the desired peak flow rate with each neurally-triggered breath, a NAVA level of 15 cmH2O/μV will be set, then the maximum pressure setting that corresponds to the desired flow rate using the pneumotachograph will be used for the study. The subject will thus be provided with "synchronized HFNC". This contrasts with the constant-flow trials when subjects will receive a constant and non-synchronized flow using the HFNC software on the ventilator.

Servo-u ventilators and Servo Tracker Software (Maquet Critical Care, Solna, Sweden) will be used in order to track Edi signal. The MP100 Biopac data acquisition (Biopac Systems Inc., Goleta, CA, USA) will be used to collect data from the monitoring devices. HFNC will be delivered using appropriately sized RAM cannula to allow for air leak around the subject's nares. Persistent bradycardia (less than 100 beats per minutes), desaturation (<85%), or hypercarbia (transcutaneous CO2 >70) will result in cessation of the study.

Being tested
Synchronized HFNC at 6 liters per minute (LPM), Continuous HFNC at 6 liters per minute (LPM), Synchronized HFNC at 8 liters per minute (LPM), Continuous HFNC at 8 liters per minute (LPM)
Medical subject headings
Bronchopulmonary Dysplasia

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Synchronized HFNC at 6 liters per minute (LPM)Other

    HFNC given in synchrony with the subject's own respiratory effort using NAVA at 6 LPM

  • Continuous HFNC at 6 liters per minute (LPM)Other

    Standard HFNC therapy at 6 LPM

  • Synchronized HFNC at 8 liters per minute (LPM)Other

    HFNC given in synchrony with the subject's own respiratory effort using NAVA at 8 LPM

  • Continuous HFNC at 8 liters per minute (LPM)Other

    Standard HFNC therapy at 8 LPM

Study groups in NCT04274192
Study groupRoleWhat they receive
Alternating between Synchronized and Continuous HFNC at 6 and 8 LPM (starting with synchronized)ExperimentalSubjects will first receive HFNC synchronized to his/her own efforts via NAVA at 6 LPM followed by continuous HFNC at 6 LPM and then HFNC synchronized to his/her own efforts via NAVA at 8 LPM followed by continuous HFNC at 8 LPM
Receives: Other: Synchronized HFNC at 6 liters per minute (LPM); Other: Continuous HFNC at 6 liters per minute (LPM); Other: Synchronized HFNC at 8 liters per minute (LPM); Other: Continuous HFNC at 8 liters per minute (LPM)
Alternating between Synchronized and Continuous HFNC at 6 and 8 LPM (starting with continuous)Active comparatorSubjects will first receive continuous HFNC at 6 LPM followed by HFNC synchronized to his/her own efforts via NAVA at 6 LPM. Next, subjects will receive continuous HFNC at 8 LPM followed by HFNC synchronized to his/her own efforts via NAVA at 8 LPM.
Receives: Other: Synchronized HFNC at 6 liters per minute (LPM); Other: Continuous HFNC at 6 liters per minute (LPM); Other: Synchronized HFNC at 8 liters per minute (LPM); Other: Continuous HFNC at 8 liters per minute (LPM)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Work of Breathing

    estimated using swing Edi

    Measured: 15 minutes

Secondary outcomes (6)
  1. Thoracoabdominal Asynchrony

    estimated by phase angle calculated by data obtained from respiratory inductance plethysmography bands

    Measured: 15 minutes

  2. Uncalibrated Tidal Volume

    as estimated using data from respiratory plethysmography bands

    Measured: 15 minutes

  3. FiO2 Requirement

    the amount of oxygen patient requires during the study

    Measured: 15 minutes

  4. Oxygen Saturation

    measured by pulse oximetry

    Measured: 15 minutes

  5. Transcutaneous Oxygen Level

    using a transcutaneous oxygen monitor

    Measured: 15 minutes

  6. Transcutaneous Carbon Dioxide Level

    using a transcutaneous carbon dioxide monitor

    Measured: 15 minutes

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted18 Feb 2020
  2. Study start9 Dec 2020
  3. Primary completion28 Jan 2021
  4. Study completion28 Jan 2021

Why it stopped: PI left and study not feasible as written in the protocol

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
1 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04274192
Sponsor's protocol ID
239863
Status last verified
Apr 2022
First submitted
29 Aug 2019
Last updated
5 May 2022
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Synchronized HFNC at 6 liters per minute (LPM), Continuous HFNC at 6 liters per minute (LPM) and Synchronized HFNC at 8 liters per minute (LPM) in people with Bronchopulmonary Dysplasia, run by University of Arkansas at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: stopped early, as of the sponsor's last update on 5 May 2022. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 8 Apr 2022). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Work of Breathing (time frame: 15 minutes). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 5 May 2022.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in