Repeated Measures Trial of Temporary Automated Manual Ventilation Versus Noninvasive Oxygenation or Conventional Vent

A study testing Mechanical ventilation with the automated BVM compressor in people with Respiratory Failure, run by Massachusetts General Hospital.

Withdrawn

Withdrawn. The study stopped before anyone enrolled.

Official record
Search all trials

Trial summary

The COVID-19 pandemic has led to a potential shortage of life-saving mechanical ventilators. The purpose of this study is to determine whether a novel simpler to device, the automated bag-valve-mask (BVM) compressor, can be used to provide assisted ventilation temporarily to patients in need. Read more about this study

Who is it for?
Ages 18 to 65 years
Conditions the study is for
Respiratory Failure
What is being tested?
Mechanical ventilation with the automated BVM compressor
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
0 participants
Where
No sites listed yet
Study dates
Aug 2022to Nov 2023
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 65 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patient may be diagnosed with Covid-19 based on clinical presentation and available laboratory studies including specific Covid-19 testing.
  • Patient with imminent respiratory failure or status post respiratory failure receiving mechanical ventilation, or requiring mechanical ventilation for airway protection or other cause.
  • Evidence of no pulmonary disease, or mild to moderate ARDS based on:
  • fraction of inspired oxygen (FiO2) ≤ 60% with arterial oxygen saturation > 90%
  • positive end expiratory pressure (PEEP) ≤ 12 cm H20
  • Using an adaptive trial design, the first 10 patients must require mechanical ventilation for reasons other than COVID-19 infection such as airway protection due to overdose, seizure, stroke, or trauma. The next 10 patients may have COVID-19 infection, but must demonstrate lung compliance ≥ 40 ml/cm H2O. If these 10 patients demonstrate a satisfactory course associated with treatment, then the final 10 patients may have lung compliance ≥ 30 ml/cm H2O. Satisfactory treatment course will include, at a minimum: oxygen saturation > 90%, with PEEP ≤ 12 cm H2O.

Who cannot join

  • Lack of informed consent from patient, if deemed having capacity, or from surrogate if not
  • Too medically unstable to participate in study per treating clinician
  • Patients requiring more than one vasopressor medication for blood pressure support
  • Age > 65 years
  • Clinical evidence of acute coronary syndrome (ACS) including angina, or ECG evidence of acute ischemia or dysrhythmia
  • Chronic lung disease including chronic obstructive pulmonary disease (COPD), pulmonary fibrosis, or pulmonary hypertension
Show all 12Show fewer
  • Gross laboratory abnormalities including, when available: liver function tests (LFT) > 5x normal, C-reactive protein (CRP) > 200 mg/L, ferritin > 2000 µg/L, creatine phosphokinase (CPK) > 3x normal, D-Dimer > 2500 ng/ml
  • Previously enrolled subject
  • Children
  • Pregnant women
  • Estimated body mass index (BMI) greater than 30
  • Prisoners

About this study

Official title: A Repeated Measures Trial of Temporary Automated Manual Ventilation Versus Noninvasive Oxygenation or Conventional Ventilation for the Treatment of COVID-19 ARDS

The COVID-19 pandemic has led to a potential shortage of life-saving mechanical ventilators. The purpose of this study is to determine whether a novel simpler to device, the automated bag-valve-mask (BVM) compressor, can be used to provide assisted ventilation temporarily to patients in need. This includes patients with COVID-19 lung infection and respiratory failure. If successful, this would increase the pool of total available ventilator hours to alleviate any shortage.

Read the detailed description

This study will be performed in the emergency department and ICU's of Massachusetts General Hospital (MGH). Thirty patients requiring mechanical ventilation will be enrolled. The design is a case series with repeated measures analysis. All patients will receive the experimental treatment as well as conventional ventilation and unassisted oxygenation as observed prior to initiation of mechanical ventilation. The compressor used will be manufactured by Spiro LLC / 10xbeta based on the open source MIT design. The device is powered by an uninterrupted power supply from a standard electrical outlet and it alarms if unplugged.

The patient will be moved into a negative pressure room. After patients with respiratory failure are intubated and stabilized on a conventional ventilator, they will receive 15 minutes of artificial respirations with the automated compressor with the conventional ventilator standing by. They will be returned to the conventional respirator after this period, or sooner if necessary. The endotracheal tube will be briefly clamped during the rapid transition from one device to another to minimize aerosolization of any viral particles and to retain any PEEP.

If the initial study period demonstrates successful respiratory support, then the procedure may be repeated once with doubling of the automated compressor treatment time to 30 minutes. There will be a minimum 15-minute observation period with conventional mechanical ventilation between the two study periods. Additionally, there will be one hour of data collection after the study periods. The total duration of the two intervention periods, the intervening period and data collection is two hours. The primary outcome is arterial oxygenation.

Patients are chemically paralyzed to facilitate intubation as part of standard care. Rocuronium is typically used for intubating chemical paralysis in the MGH emergency department. It has a half-life of 66 minutes. A single repeat bolus will be provided if needed to ensure chemical paralysis for the duration of the study. If the patient is already intubated and no longer chemically paralyzed, than one bolus of rocuronium, and a second as needed, or just a temporary increase in ongoing sedation will be provided to minimize spontaneous respiration. The airway circuit will be continuously monitored with a separate pressure and flow monitor (Nico) with recorded digital output throughout the experiment.

Being tested
Mechanical ventilation with the automated BVM compressor
Keywords
mechanical ventilator
Medical subject headings
Respiratory Insufficiency

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Mechanical ventilation with the automated BVM compressorDevice

    Mechanical ventilation is accomplished with a device that mechanically squeezes a manual bag valve instead of by hand. The rate and volume of compression are adjustable, and the device has appropriate alarms and safety features.

Study groups in NCT04369274
Study groupRoleWhat they receive
InterventionalExperimentalAll subjects will briefly be placed on the automated BVM compressor device. Measurements obtained while on this device will be compared to those obtained in the same subject prior to mechanical ventilation and while on a conventional ventilator.
Receives: Device: Mechanical ventilation with the automated BVM compressor

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Arterial oxygenation

    Arterial oxygenation obtained as measured by noninvasive pulse oximetry and arterial blood gas.

    Measured: Measurement 10 minutes after onset of initial period of automatic compressed ventilations

  2. Arterial oxygenation

    Arterial oxygenation obtained as measured by noninvasive pulse oximetry and arterial blood gas.

    Measured: Measurement 20 minutes after onset of second period of automatic compressed ventilations

Secondary outcomes (5)
  1. Expired pressure of carbon dioxide.

    Expired carbon dioxide (CO2) pressure will be measured continuously with a monitor in the airway circuit.

    Measured: 2 hour total study period.

  2. Airway pressure

    The pressure (cm H2O) of inspired and expired air in the airway circuit while the subject is mechanically ventilated will be measured continuously using a Nico monitor.

    Measured: 2 hour total study period.

  3. Heart rate

    Subject heart rate (beats per minute) will be measured continuously using a telemetry monitor,

    Measured: 2 hour total study period.

  4. Blood pressure

    Subject blood pressure (mm Hg) will be measured episodically every 5 minutes using an automated arm cuff.

    Measured: 2 hour total study period.

  5. Airway flow

    The flow (L/min) of inspired and expired air in the airway circuit while the subject is mechanically ventilated will be measured continuously using a Nico monitor.

    Measured: 2 hour total study period.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted30 Apr 2020
  2. Study startAug 2022 (estimated)
  3. Primary completionNov 2023 (estimated)
  4. Study completionNov 2023 (estimated)

Why it stopped: The epidemic of Covid pneumonia requiring large scale mechanical ventilation has abated and the need to explore alternate ventilatory devices has resolved.

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Model description
The design is a case series with repeated measures analysis. All patients will receive the experimental treatment as well as conventional ventilation and unassisted oxygenation as observed prior to initiation of mechanical ventilation.
Masking
None (open label)
Enrolment
0 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04369274
Sponsor's protocol ID
2020P001051
Status last verified
Mar 2023
First submitted
23 Apr 2020
Last updated
15 Mar 2023
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Publications

  • Al Husseini AM, Lee HJ, Negrete J, Powelson S, Servi AT, Slocum AH, Saukkonen J. Design and Prototyping of a Low-Cost Portable Mechanical Ventilator. J Med Device. 2010 Jun 1;4(2):027514. doi: 10.1115/1.3442790. Epub 2010 Aug 9.

    PubMed 32328214

Questions about this trial

What is this clinical trial studying?

A study testing Mechanical ventilation with the automated BVM compressor in people with Respiratory Failure, run by Massachusetts General Hospital.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 12 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: withdrawn, as of the sponsor's last update on 15 Mar 2023. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study was withdrawn before enrolling participants, so there are no results.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Arterial oxygenation (time frame: Measurement 10 minutes after onset of initial period of automatic compressed ventilations). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04369274, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 Mar 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in