Acute Respiratory Distress SyndromeNCT04369599
Trans Thoracic Manipulation of Ventilation/Perfusion: the V/Q System
A study testing V/Q System in people with Acute Respiratory Distress Syndrome and COVID-19, run by Emory University at 1 site in United States.
Trial summary
The purpose of this pilot study is to measure the impact of non-invasive pneumatic manipulation of transthoracic pressure on oxygenation in patients with Acute Respiratory Distress Syndrome (ARDS) due to Coronavirus Disease 2019 (COVID 19) who are on mechanical ventilator support. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Acute Respiratory Distress Syndrome, COVID-19
- What is being tested?
- V/Q System
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 15 participants
- Where
- 1 siteUnited States
- Study dates
- 11 Aug 2020to Nov 2026
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Presentation with acute respiratory distress syndrome (ARDS) requiring intubation with mechanical ventilator support. ARDS will be defined by the ratio of the partial pressure of oxygen in the patient's arterial blood (PaO2) to the fraction of oxygen in the inspired air (FiO2) as being < 300.
- Ability of a Legally Authorized Representative (LAR) to provide consent on behalf of the patient.
Who cannot join
- Presence of cutaneous wounds that would be compromised by the Vest including stage 3 or greater pressure ulcers and the presence of actively treated burns
- Patients with pre-existing pulmonary hypertension and pulmonary fibrosis
- Bony chest trauma within the last 10 days
- Contraindications to esophageal manometry including recent esophageal trauma or surgery
- Abdominal compartment syndrome
- Active or recent gross hemoptysis
Show all 12Show fewer
- Elevated intracranial pressure >20 mmHg
- LAR refusal to participate
- Severe Scoliosis
- Morbidly obese (BMI >37)
- Pregnant women
- Unable to maintain oxygen saturation > 88%
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
About this study
The purpose of this pilot study is to measure the impact of non-invasive pneumatic manipulation of transthoracic pressure on oxygenation in patients with Acute Respiratory Distress Syndrome (ARDS) due to Coronavirus Disease 2019 (COVID 19) who are on mechanical ventilator support. This will be achieved by a pneumatic Vest placed around the chest wall of consenting patients who meet inclusion criteria. The Vest is essentially a non-invasive segmental device placed upon the anterior and posterior right and left aspects of the chest wall. The researchers have the ability to inflate and deflate the chambers of the Vest to achieve preset pressures as determined by the protocol and observe the patient's physiological response. Participants will have up to four hours of intervention with the study intervention, followed by 1 hour of post-intervention observation.
Read the detailed description
Since the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) surfaced at the end of 2019, transmission has been rapid and particularly lethal. Death is most commonly due to ARDS which has been quoted as occurring in up to 42% of patients. The rapid lethality of the COVID-19 has emphasized the limitations of currently available therapies in the Intensive Care Unit. Traditional mechanical ventilator support, the use of inhaled and systemic pulmonary vasodilatory drugs, invasive monitoring, proning and extracorporeal membrane oxygenation (ECMO) to name a few, are all voracious consumers of resources and have culminated in at least $27 billion expenditure per annum in the US alone pre-virus. This fiscal burden has been far exceeded in the current pandemic. With patient numbers growing exponentially hospital resources are being rapidly surpassed with ICU's overflowing which is exacerbated by a national shortage of mechanical ventilators. New techniques are demanded to both treat patients and identify responders if medical resources are to be optimized.
Traditionally, patients present to the ICU and are intubated once a threshold of respiratory distress and failure is reached. Various maneuvers are initiated to optimize oxygen uptake by the lungs to prevent the onset of organ failure and death. At present, there are no effective bridging technologies providing intervention between intubation to these costly more complex techniques which are almost solely the purview of more technologically adept tertiary academic centers. Clinical practice is often empiric and driven by trial and error in this emerging disease, largely because there are presently no clinical tests to provide clinicians with any clear indication as to which and whether patients will respond to these more costly difficult procedures. This is in part due to the underlying pathophysiology of ARDS where there is a further "uncoupling" between bloodflow,(and hence uptake of oxygen), and healthy lung units which allow transfer and absorption of oxygen because of the damage to the alveoli. This phenomenon shifts physiologic Ventilation/Perfusion mismatch (V/Q mismatch) into a pathologic state. Since this phenomenon is worsened by diseased tissue, it is diffuse but, not uniform and response to therapy is difficult to determine based on current modalities. Thus, many therapies are therefore instituted purely by trial and error. Determination of appropriate candidates for advanced therapeutic techniques is critically important as they are not without risk and resource consumption. Patients who are profoundly hypoxic and fail traditional supine position support are "flipped" onto their abdomen to assume the prone position, a technique known as proning. This requires a team of at least 6 nurses, respiratory therapists and physicians who attempt to ensure that there are no adverse events. Such complications contribute to the morbidity and potential mortality of the maneuver and include accidental extubation (displacement of the endotracheal tube out of the trachea), disconnection from the ventilator, transient worsening hypoxia, hemodynamic instability, dislodgement of central and peripheral venous catheters to name a few. This is further compounded by the need for greater sedation which is itself associated with hemodynamic instability, aspiration, altered conscious state and an increase in acuity of monitoring making it much more labor intensive and expensive.
The researchers propose the development of a ventilation/ perfusion system, (V/Q System), a pneumatically driven device which can improve oxygenation by adjusting trans-thoracic pressure gradients. This is a new field of lung physiology which is only just being explored. However, the concept of noninvasive manipulation of lung mechanics and ventilation/perfusion mismatch is profoundly impactful as it potentially introduces a comparatively safe technique to address an otherwise fatal failure of lung function. The V/Q System represents an effort to optimize lung function without the risk of patient proning. If successful, improved oxygenation associated with the device has multiple clinical and economic ramifications. Initially, the device may obviate the need to more costly, time consuming and potentially morbid procedures. Future research may include investigating if the device may be utilized to identify both "responders" and "non-responders" to advanced therapeutic techniques and can help eliminate the "trial and error" approach in managing complex ARDS patients.
The study procedures will take up to 5 hours to complete for each participant enrolled. During this time, the participant will be sedated per standard ICU protocol. Each study participant will have up to 4 hours of intervention with the study V/Q System, followed by 1 hour of post-intervention observation.
- Conditions
- Acute Respiratory Distress Syndrome, COVID-19
- Being tested
- V/Q System
- Medical subject headings
- Respiratory Distress Syndrome, COVID-19
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
V/Q SystemDevice
With the patient supine, sedated, and hemodynamically stable, the Vest is placed upon the patient and secured by clinicians and staff. All chambers of the Vest will be inflated simultaneously. First inflation will be for one hour to a pressure of 0.4 psi. Subsequent inflations at 0.8 and finally 1.2 psi will be performed for one hour each. Participants will be treated for up to four hours and then will be observed for an additional hour.
| Study group | Role | What they receive |
|---|---|---|
| V/Q System | Experimental | Participants with acute respiratory failure will undergo therapy with the V/Q System. Receives: Device: V/Q System |
What is being measured
The primary outcome is the main question the study is designed to answer.
Change in Arterial Oxygenation Levels
Improvement in oxygenation will be assessed by a demonstrated >20% increase in arterial oxygen levels after 180 minutes of treatment with the V/Q Vest, with two different levels of pressure. Normal levels of arterial oxygen range from 75 to 100 millimeters of mercury (mm Hg). Low oxygenation levels necessitate supplemental oxygen.
Measured: Baseline, Hour 1, Hour 2, Hour 3, Hour 4, 1 Hour Post-intervention
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted30 Apr 2020
- Study start11 Aug 2020
- Primary completionNov 2026 (estimated)
- Study completionNov 2026 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Acute Respiratory Distress SyndromeStudies of the same condition, open and under way.
- More trials run by Emory UniversityThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Device feasibility
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 15 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Emory University
- Sponsor type
- University, hospital or other
- Collaborators
- Georgia Tech Research Foundation, Georgia Clinical & Translational Science Alliance
- Responsible party
- Principal investigator, Maxwell Weinmann, Emory University
- Investigators
- Maxwell Weinmann, MD, Principal investigator, Emory University
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04369599
- Sponsor's protocol ID
- STUDY00000402
- Other IDs
- 2025P009256
- Status last verified
- Jun 2026
- First submitted
- 28 Apr 2020
- Last updated
- 30 Jun 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- Yes: All of the individual participant data collected during the trial will be made available for sharing, after deidentification.
Study at a glance
From the registry record, last updated by the sponsor on 30 Jun 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Trans Thoracic Manipulation of Ventilation/Perfusion: the V/Q System
- ClinicalTrials.gov ID
- NCT04369599
- Acronym / sponsor ID
- STUDY00000402
- Conditions
- Acute Respiratory Distress Syndrome, COVID-19
- Study type
- Interventional
- Recruitment status
- Enrolling by invitation
- Enrolment
- 15 participants (estimated)
- Lead sponsor
- Emory UniversityUniversity, hospital or other
- Collaborators
- Georgia Tech Research Foundation, Georgia Clinical & Translational Science Alliance
- Study start
- 11 Aug 2020 (actual)
- Primary completion
- Nov 2026 (estimated)
- Study completion
- Nov 2026 (estimated)
- First posted
- 30 Apr 2020 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of this pilot study is to measure the impact of non-invasive pneumatic manipulation of transthoracic pressure on oxygenation in patients with Acute Respiratory Distress Syndrome (ARDS) due to Coronavirus Disease 2019 (COVID 19) who are on mechanical ventilator support. This will be achieved by a pneumatic Vest placed around the chest wall of consenting patients who meet inclusion criteria. The Vest is essentially a non-invasive segmental device placed upon the anterior and posterior right and left aspects of the chest wall. The researchers have the ability to inflate and deflate the chambers of the Vest to achieve preset pressures as determined by the protocol and observe the patient's physiological response. Participants will have up to four hours of intervention with the study intervention, followed by 1 hour of post-intervention observation.
Detailed description
Since the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) surfaced at the end of 2019, transmission has been rapid and particularly lethal. Death is most commonly due to ARDS which has been quoted as occurring in up to 42% of patients. The rapid lethality of the COVID-19 has emphasized the limitations of currently available therapies in the Intensive Care Unit. Traditional mechanical ventilator support, the use of inhaled and systemic pulmonary vasodilatory drugs, invasive monitoring, proning and extracorporeal membrane oxygenation (ECMO) to name a few, are all voracious consumers of resources and have culminated in at least $27 billion expenditure per annum in the US alone pre-virus. This fiscal burden has been far exceeded in the current pandemic. With patient numbers growing exponentially hospital resources are being rapidly surpassed with ICU's overflowing which is exacerbated by a national shortage of mechanical ventilators. New techniques are demanded to both treat patients and identify responders if medical resources are to be optimized.
Traditionally, patients present to the ICU and are intubated once a threshold of respiratory distress and failure is reached. Various maneuvers are initiated to optimize oxygen uptake by the lungs to prevent the onset of organ failure and death. At present, there are no effective bridging technologies providing intervention between intubation to these costly more complex techniques which are almost solely the purview of more technologically adept tertiary academic centers. Clinical practice is often empiric and driven by trial and error in this emerging disease, largely because there are presently no clinical tests to provide clinicians with any clear indication as to which and whether patients will respond to these more costly difficult procedures. This is in part due to the underlying pathophysiology of ARDS where there is a further "uncoupling" between bloodflow,(and hence uptake of oxygen), and healthy lung units which allow transfer and absorption of oxygen because of the damage to the alveoli. This phenomenon shifts physiologic Ventilation/Perfusion mismatch (V/Q mismatch) into a pathologic state. Since this phenomenon is worsened by diseased tissue, it is diffuse but, not uniform and response to therapy is difficult to determine based on current modalities. Thus, many therapies are therefore instituted purely by trial and error. Determination of appropriate candidates for advanced therapeutic techniques is critically important as they are not without risk and resource consumption. Patients who are profoundly hypoxic and fail traditional supine position support are "flipped" onto their abdomen to assume the prone position, a technique known as proning. This requires a team of at least 6 nurses, respiratory therapists and physicians who attempt to ensure that there are no adverse events. Such complications contribute to the morbidity and potential mortality of the maneuver and include accidental extubation (displacement of the endotracheal tube out of the trachea), disconnection from the ventilator, transient worsening hypoxia, hemodynamic instability, dislodgement of central and peripheral venous catheters to name a few. This is further compounded by the need for greater sedation which is itself associated with hemodynamic instability, aspiration, altered conscious state and an increase in acuity of monitoring making it much more labor intensive and expensive.
The researchers propose the development of a ventilation/ perfusion system, (V/Q System), a pneumatically driven device which can improve oxygenation by adjusting trans-thoracic pressure gradients. This is a new field of lung physiology which is only just being explored. However, the concept of noninvasive manipulation of lung mechanics and ventilation/perfusion mismatch is profoundly impactful as it potentially introduces a comparatively safe technique to address an otherwise fatal failure of lung function. The V/Q System represents an effort to optimize lung function without the risk of patient proning. If successful, improved oxygenation associated with the device has multiple clinical and economic ramifications. Initially, the device may obviate the need to more costly, time consuming and potentially morbid procedures. Future research may include investigating if the device may be utilized to identify both "responders" and "non-responders" to advanced therapeutic techniques and can help eliminate the "trial and error" approach in managing complex ARDS patients.
The study procedures will take up to 5 hours to complete for each participant enrolled. During this time, the participant will be sedated per standard ICU protocol. Each study participant will have up to 4 hours of intervention with the study V/Q System, followed by 1 hour of post-intervention observation.
Study design
- Primary purpose
- Device feasibility
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| V/Q System | Experimental | Device: V/Q SystemParticipants with acute respiratory failure will undergo therapy with the V/Q System. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (2 listed)
- Presentation with acute respiratory distress syndrome (ARDS) requiring intubation with mechanical ventilator support. ARDS will be defined by the ratio of the partial pressure of oxygen in the patient's arterial blood (PaO2) to the fraction of oxygen in the inspired air (FiO2) as being < 300.
- Ability of a Legally Authorized Representative (LAR) to provide consent on behalf of the patient.
Key exclusion criteria (12 listed)
- Presence of cutaneous wounds that would be compromised by the Vest including stage 3 or greater pressure ulcers and the presence of actively treated burns
- Patients with pre-existing pulmonary hypertension and pulmonary fibrosis
- Bony chest trauma within the last 10 days
- Contraindications to esophageal manometry including recent esophageal trauma or surgery
- Abdominal compartment syndrome
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| V/Q SystemWith the patient supine, sedated, and hemodynamically stable, the Vest is placed upon the patient and secured by clinicians and staff. All chambers of the Vest will be inflated simultaneously. First inflation will be for one hour to a pressure of 0.4 psi. Subsequent inflations at 0.8 and finally 1.2 psi will be performed for one hour each. Participants will be treated for up to four hours and then will be observed for an additional hour. | Device | V/Q System |
Primary outcome
Change in Arterial Oxygenation Levels
Time frame: Baseline, Hour 1, Hour 2, Hour 3, Hour 4, 1 Hour Post-intervention
Improvement in oxygenation will be assessed by a demonstrated >20% increase in arterial oxygen levels after 180 minutes of treatment with the V/Q Vest, with two different levels of pressure. Normal levels of arterial oxygen range from 75 to 100 millimeters of mercury (mm Hg). Low oxygenation levels necessitate supplemental oxygen.
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 30 Jun 2026.
- Individual participant dataSharing planned: Yes. All of the individual participant data collected during the trial will be made available for sharing, after deidentification.
Related trials for Acute Respiratory Distress Syndrome
Enrolling by invitation
Personalized Ventilator Settings for Patients on ECMO
Acute Respiratory Distress Syndrome (ARDS), Extracorporeal Membrane Oxygenation
Active, not recruiting
CT for Personalized Mechanical Ventilation
Ventilator-Induced Lung Injury, Sepsis Syndrome
Not yet recruitingObservational study
Development and Multicenter Validation of an Explainable System for Neonatal ARDS-Compatible Phenotyping
Acute Respiratory Distress Syndrome
RecruitingObservational study
Assessment of Blood Viscosity in ARDS (Acute Respiratory Distress Syndrome)
ARDS
Recruiting
Comparing Surfactant Administration Through Supraglottic Airway and Thin Catheter for Preterm Infants
Surfactant, Respiratory Distress Syndrome (Neonatal)
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Maxwell Weinmann, MD principal investigator
Emory University
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing V/Q System in people with Acute Respiratory Distress Syndrome and COVID-19, run by Emory University at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 12 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: enrolling by invitation, as of the sponsor's last update on 30 Jun 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Change in Arterial Oxygenation Levels (time frame: Baseline, Hour 1, Hour 2, Hour 3, Hour 4, 1 Hour Post-intervention). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 30 Jun 2026.