AzTrials
AzTrials

Cardiac CatheterizationREDEFINENCT04404257

Reduce Radiation Exposure in Fluoroscopic Interventions Evaluation

A study of Cardiac Catheterization and Radiation Exposure, run by Corewell Health East at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of this study is to determine whether the ControlRad system device when installed in Fluoroscopic (x-ray) machine reduces radiation dose to operators (Doctors and nurses) and to the patient who is undergoing cardiac Catheterization and electrophysiology (EP) implant procedures. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Cardiac Catheterization, Radiation Exposure
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
170 participants
Where
1 siteUnited States
Study dates
5 Nov 2020to 3 Dec 2021
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • - Patient
  • Scheduled to undergo left heart catheterization with angiography, and/or percutaneous coronary intervention
  • Scheduled to undergo pacemaker or ICD implant
  • EP device upgrade
  • Able to provide written informed consent prior to the procedure
  • Age ≥18 years
  • Physicians and Staff o Able to provide consent for the study

Who cannot join

  • - Patient
  • Cardiogenic shock
  • Reason for cath procedure is pericardiocentesis
  • Subcutaneous ICDs
  • Lead revisions
  • Inability to provide informed consent
Show all 9Show fewer
  • Pregnant
  • Physicians and Staff
  • Those who are not willing to participate in the study

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Beaumont Hospital - Royal Oak

    Royal Oak, Michigan, 48073

Other trials in United States

About this study

Official title: Reduce Radiation Exposure in Fluoroscopic Interventions Evaluation (REDEFINE): A Prospective, Randomized Evaluation of the ControlRad System to Reduce Radiation Exposure During Cardiac Catheterization and Electrophysiology (EP) Procedures.

The purpose of this study is to determine whether the ControlRad system device when installed in Fluoroscopic (x-ray) machine reduces radiation dose to operators (Doctors and nurses) and to the patient who is undergoing cardiac Catheterization and electrophysiology (EP) implant procedures.

Read the detailed description

This is a Prospective, randomized (like a "flip of a coin") single center study evaluating the ControlRad system device when installed - retrofitted on existing C-arms for fluoroscopy (x-ray) will reduce radiation exposure without compromising image quality in the region of interest and overall workflow during cardiac catheterization and electrophysiology (EP) implant procedures. Enrollment will be limited to 40 cardiac catheterization, and 30 pacemaker and/or ICD procedures. All patients presenting to Beaumont Hospital Royal Oak who are scheduled for cardiac catheterization with coronary angiography and electrophysiology implant in Cath Lab 5 where device is installed will be considered for inclusion in the study. Physicians and staff (20 fellows; 35 attending physicians; and 56 Cath-lab staff,including Nurse/Anesthesia team) will be invited to participate in the study. For each procedure, 3 staff members will be study subjects: a) the primary operator, b) the secondary operator, c) the nurse/tech and or Anesthetist who circulates in the room. Different operators and staff may participate in each case depending on cath-lab scheduling. The Primary operator is the physician who usually stands nearest to the C-arm. In most cases in Beaumont this is a Cardiology Fellow in cardiac catheterization cases and Attending Physician for the EP cases. The Secondary operator is the physician who typically stands to the right of the primary operator and in most cases is the attending cardiologist or scrub assistant (nurse/technician). The Nurse or Anesthesia team typically circulates in the room and is responsible for monitoring the patient, administering medications and obtaining equipment for the procedure.

Two methods will be used to measure radiation dose during the catheterization procedure. The Real-time Dosimeter Badge (RaySafe) and the Landauer Luxel Aluminium Oxide Dosimeter Badges. Cardiac Catheterization and electrophysiology implant procedures will be performed according to standard guidelines.

Participants will be randomized 1:1 to either cardiac catheterization without ControlRad or cardiac catheterization with the ControlRad system. The same 1:1 randomization process will be applied to the EP patient population. Participants will be blinded to the randomization.

Once procedure is done,participation also ended and the badges will be removed by the Radiation Safety Officer or research coordinator.

Being tested
ControlRad System, Without ControlRad System
Keywords
ControlRad System, Cardiac Catheterization, Radiation Exposure, Fluoroscopic x-ray

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • ControlRad SystemRadiation

    Cardiac Catheterization or electrophysiology implant procedures with Control Rad system device installed in the cath lab room #5.

  • Without ControlRad SystemRadiation

    Cardiac Catheterization or electrophysiology implant procedures in cath lab room 5 without the ControlRad system device.

Study groups in NCT04404257
Study groupRoleWhat they receive
ControlRad SystemExperimentalParticipant will undergo Cardiac catheterization or electrophysiology implant procedures with the ControlRad system installed in Cath lab room 5
Receives: Radiation: ControlRad System
Without ControlRad SystemActive comparatorParticipant will undergo the cardiac catheterization or electrophysiology implant procedures per standard of care. Meaning, without the ControlRad system installed in Cath lab room 5.
Receives: Radiation: Without ControlRad System

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Radiation Dose to Primary Operator (RaySafe), Cardiac Catheterization

    Median effective radiation dose in microsievert (μSv) to the primary operator at the thyroid. This was measured using a RaySafe dosimeter to assess the radiation dose in each case.

    Measured: During each cardiac catheterization, an average of 90 minutes

  2. Radiation Dose to Primary Operator (Luxel Dosimeter), Cardiac Catheterization

    Mean effective radiation dose in microsievert (μSv) to the primary operator at the thyroid. This was measured using a single Luxel dosimeter over all cases to assess the cumulative dose in the study arm.

    Measured: During each cardiac catheterization, an average of 90 minutes

  3. Radiation Dose to Primary Operator, EP Procedure (Luxel)

    Mean effective radiation dose in microsievert (μSv) to the primary operator at the end of each EP implant procedure. A single Luxel dosimeter was and a cumulative dose was recorded.

    Measured: During each EP implant procedure, an average of 90 minutes

  4. Radiation Dose to Primary Operator, EP Procedure (RaySafe)

    Median effective radiation dose in microsievert (μSv) to the primary operator at the end of each EP implant procedure using a RaySafe dosimeter. This is measured after each case.

    Measured: During each EP implant procedure, an average of 90 minutes duration

Secondary outcomes (12)
  1. Radiation Dose to Secondary Operator, Cardiac Catheterization (RaySafe)

    Median effective radiation dose (μSv) to the secondary operator at the thyroid. This was measured using a RaySafe dosimeter to assess the radiation dose in each case.

    Measured: During each cardiac catheterization, an average of 90 minutes

  2. Radiation Dose to Secondary Operator (Luxel Dosimeter), Cardiac Catheterization

    Mean effective radiation dose in microsievert (μSv) to the secondary operator at the thyroid. This was measured using a single Luxel dosimeter over all cases to assess the cumulative dose in the study arm.

    Measured: During each cardiac catheterization, an average of 90 minutes

  3. Radiation Dose to Nurse or Anesthetist, Cardiac Catheterization (RaySafe)

    Median effective radiation dose in microsievert (μSv) to the Nurse 0r Anesthetist at the thyroid. This was measured using a RaySafe dosimeter to assess the radiation dose in each case.

    Measured: During each cardiac catheterization, an average of 90 minutes

  4. Radiation Dose to Nurse or Anesthetist, Cardiac Catheterization (Luxel)

    Mean effective radiation dose in microsievert (μSv) to the Nurse or Anesthetist at the thyroid. This was measured using a single Luxel dosimeter over all cases to assess the cumulative dose in the study arm.

    Measured: During each cardiac catheterization, an average of 90 minutes

  5. Radiation Dose to Patient, Cardiac Catheterization

    Median radiation dose-area product (DAP) to the patient at the end of each cardiac catheterization case using data from a fluoroscopy machine. DAP is defined as the absorbed dose multiplied by the area irradiated micro-gray μGy*m^2.

    Measured: During each cardiac catheterization, an average of 90 minutes

  6. Radiation Dose in Cath Lab Room #5, Cardiac Catheterization

    Mean radiation dose microsieverts (μSv) at the end of each cardiac catheterization case at a standard location on the wall of the catheterization laboratory. This was measured using a single Luxel dosimeter over all cases to assess the cumulative dose in the study arm.

    Measured: During each cardiac catheterization, an average of 90 minutes

  7. Radiation Dose to Secondary Operator, EP Procedure (RaySafe)

    Mean effective radiation dose (μSv) to the secondary operator at the at the thyroid. This was measured using a RaySafe dosimeter to assess the radiation dose in each case.

    Measured: During each EP implant procedure, an average of 90 minutes

  8. Radiation Dose to Secondary Operator, EP Procedure (Luxel)

    Mean effective radiation dose (μSv) to the secondary operator at the at the thyroid. This was measured using a single Luxel dosimeter over all cases to assess the cumulative dose in the study arm.

    Measured: During each EP implant procedure, an average of 90 minutes

  9. Radiation Dose to Nurse or Anesthetist, EP Procedure (RaySafe)

    Median effective radiation dose in microsievert (μSv) to the primary operator at the thyroid. This was measured using a RaySafe dosimeter to assess the radiation dose in each case.

    Measured: During each EP implant procedure, an average of 90 minutes

  10. Radiation Dose to Nurse or Anesthetist, EP Procedure (Luxel)

    Mean effective radiation dose in microsievert (μSv) to the primary operator at the thyroid. This was measured using a single Luxel dosimeter over all cases to assess the cumulative dose in the study arm.

    Measured: During each EP implant procedure, an average of 90 minutes

  11. Radiation Dose to Patient, EP Procedure

    Mean radiation dose-area product (DAP) to the patient at the end of each EP implant procedure using data from a fluoroscopy machine. DAP is defined as the absorbed dose multiplied by the area irradiated (μGy*m^2)

    Measured: During each EP implant procedure, an average of 30-45 minutes of active radiation

  12. Radiation Dose in Cath Lab Room #5, EP Procedure

    Mean radiation dose (μSv) at the end of each EP implant procedure at a standard location on the wall of the catheterization laboratory. This was measured using a single Luxel dosimeter over all cases to assess the cumulative dose in the study arm.

    Measured: During each EP implant procedure, an average of 90 minutes

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted27 May 2020
  2. Study start5 Nov 2020
  3. Primary completion3 Dec 2021
  4. Study completion3 Dec 2021

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Prevention
Allocation
Randomised
Intervention model
Parallel groups
Model description
Randomized 1:1 like a flip of a coin, to receive either cardiac catheterization and or electrophysiology implant procedures without ControlRad system or cardiac catheterization and or electrophysiology (EP) implant procedures with the ControlRad system.
Masking
Single blind
Who is masked
Participant
Enrolment
170 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04404257
Sponsor's protocol ID
2019-174
Acronym
REDEFINE
Status last verified
Dec 2022
First submitted
8 Apr 2020
Last updated
11 Jan 2023
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study of Cardiac Catheterization and Radiation Exposure, run by Corewell Health East at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 7 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 11 Jan 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 11 Jan 2023). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Radiation Dose to Primary Operator (RaySafe), Cardiac Catheterization (time frame: During each cardiac catheterization, an average of 90 minutes). The study lists 4 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 11 Jan 2023; AzTrials last refreshed its copy on 26 Oct 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in