Pacemaker DDDPace-ConductNCT04416958
Pacing to Maintain Physiologic Ventricular Activation
An observational study of Pacemaker DDD and His Bundle Pacing, run by Klinikum-Fuerth at 1 site in Germany.
Trial summary
Right ventricular pacing causes ventricular dyssynchrony and may be associated with impaired outcome. In the last decade, several approaches for more physiological pacing became available and were implemented in the latest guidelines. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Pacemaker DDD, His Bundle Pacing, LBB Area Pacing
- What is being tested?
- cardiac implantable electronic device (CIED) implantation
- Type of treatment
- Medical device
- How many people
- 200 participants
- Where
- 1 siteGermany
- Study dates
- 1 Jan 2018to 31 Dec 2030
- How long will I take part?
- 1 Year
- Phase
- Observational
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: Patients undergoing Pacemaker or ICD Implantation according to current Guidelines with the aim to avoid pacing induced ventricular dyssynchrony. Subgroups according to type of device implanted, lead Position and programming.
Who may be able to join
- Pacemaker or ICD Implantation aiming to avoid pacing induced ventricular dyssynchrony according to current guidelines
- age >= 18 years
Who cannot join
- no informed consent for the procedure given
- no follow-up data
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
Germany1 site, 1 recruiting
- Recruiting
Klinikum Fuerth
Fürth, Bavaria, 90766
Dirk Bastian, MD, +49 (0)911 7580 1101, dirk.bastian@klinikum-fuerth.de
Laura Vitali-Serdoz, MD, +49 (0)911 7580 1101, laura.vitali-serdoz@klinikum-fuerth.de
About this study
Official title: Pacing for Cardiac Resynchronisation Using the Intrinsic Conduction System to Maintain Physiologic Ventricular Activation
Right ventricular pacing causes ventricular dyssynchrony and may be associated with impaired outcome. In the last decade, several approaches for more physiological pacing became available and were implemented in the latest guidelines. However, compared to conventional device implantation, cardiac resynchronization, His bundle pacing and left bundle area pacing remain demanding procedures in the individual case. Goal of the single center observational "Pace conduct" study is to evaluate implantation success, safety and outcome of pacing methods that maintain physiologic ventricular activation.
Read the detailed description
Background:
Conventional ectopic myocardial right ventricular pacing (RVP) causes ventricular dyssynchrony and may be associated with reverse ventricular remodeling, reduced ejection fraction (EF), left ventricular dilatation, functional mitral valve regurgitation, heart failure and an increased rate of new onset atrial fibrillation.
Dependent on individual patient's characteristics, several strategies are established to prevent and to overcome the potential drawbacks of chronic RVP. In general, unnecessary ectopic RVP should be avoided. For example, in patients with sinus node disease and intact atrioventricular (AV) conduction, atrial pacing, AV (search) hysteresis or AAI-DDD/ADI pacing may be used. In patients with impaired cardiac function and an expected higher percentage of RVP, pacing strategies for cardiac resynchronization are indicated. Conventional cardiac resynchronization therapy (CRT) uses an additional transvenous left ventricular lead for synchronous ventricular stimulation and was shown to shorten QRS duration and to reduce morbidity and mortality in patients with chronic heart failure, left bundle branch block (LBBB) and reduced EF. Due to the non-physiological left ventricular epicardial stimulation, however, conventional CRT is associated with 30% of non-responders and may even prolong ventricular activation in patients with narrower QRS complex. First described in 1968, His bundle pacing (HBP) has evolved to an increasingly used alternative for cardiac pacing. Currently, HBP is regarded the most physiologic approach for ventricular stimulation because it prevents ventricular dyssynchrony and its potential fatal long-term consequences by preserving normal electrical activation of the ventricles. Clinical benefit of HBP has been shown compared with conventional permanent RVP and CRT. Recent studies documented restoration of normal electrical and mechanical left ventricular synchrony for both selective and non-selective HBP. However, compared with conventional RVP the implantation procedure for HBP is much more demanding requiring exact placement of the pacing lead within the anatomically variable His bundle area. Alternatively, the correction of bundle branch conduction disorders has been demonstrated for left bundle branch area (LBBA) pacing. As a consequence, current guidelines recommend pacing methods that maintain physiologic ventricular activation in patients with atrioventricular block who have an indication for permanent pacing with a LVEF between 36% and 50% and are expected to require ventricular pacing more than 40% of the time (class IIa indication).
In summary, there is increasing evidence showing the benefits of the different strategies for physiologic pacing but the appropriate use of these approaches may be challenging in the individual case. Therefore, appropriate patient selection, implantation approaches, device programming and follow-up require further intensive evaluation.
Objective:
Main goal of the study is to evaluate implantation success for pacing methods aiming to maintain physiologic ventricular activation. Procedural success is defined as stable lead positioning and effective pacing within the target area with an appropriate and stable pacing threshold.
Secondary goals of the study are to document and to evaluate
- procedural parameters (e.g. venous access, time needed for lead implant, procedural duration, radiation) and adverse events dependent on procedural approaches and patients characteristics,
- performance of the implanted system (sensing, pacing thresholds) and clinical outcome during routine follow-up
Study design:
Single center, non-randomized, observational study, retrospective data analysis, on-going prospective patient enrollment, descriptive statistics.
Center: Klinikum Fuerth (Dept. for Heart and Lung diseases, section for clinical electrophysiology) / Germany in cooperation with the Dept. of Cardiology of the University Erlangen / Germany and the University of Trieste / Italy.
Patients and methods:
Primary endpoint: Implantation success. Effective pacing and acceptable pacing threshold at the targeted lead position. Target for lead placement is the area with maximum delayed ventricular activation for transvenous CRT, the His bundle for selective or non-selective HBP and the right interventricular septum with left bundle branch capture for LBBA pacing, respectively. Target thresholds for the lead placed within the coronary sinus or at the intrinsic conduction system is <2.5 V @ 1 ms with a maximum acceptable threshold of <4.0 V @ 2 ms or <5 V @ 1 ms. Target for all other leads is <1 V @ 0.5 ms.
Secondary endpoints: patient characteristics and association with outcome. Implantation success and outcome correlated with patient characteristics including electrocardiogram and echocardiographic parameter and procedure related techniques and parameter. Safety: radiation exposure, number and type of adverse events and adverse device related events. Follow-up: device function, interrogation, programming and clinical outcome as evaluated in routine follow-up, incl. ECG, echocardiography and parameter for assessment of heart failure. Subpopulations: managed ventricular pacing, His bundle pacing, LBB-area pacing, CRT. Implantation with or without electroanatomic mapping system.
Inclusion criteria:
Implantation of a pacemaker or ICD according to the current guidelines (Class I or IIa indication) aiming to avoid pacing induced dyssynchrony, e.g. managed ventricular pacing, His-bundle pacing, LBB-area pacing or conventional transvenous CRT. Age ≥ 18 years.
Exclusion criteria:
No given informed consent for the procedure. No follow up data available.
Sample size:
For the observational study, there is no pre-specified sample-size. Data from 200 patients and procedures are expected.
Data security:
Study related data are collected by the study investigators in an anonymous clinic-internal data-base that is password protected. All investigators have to provide valid GCP training.
Risk estimation:
The study is observational and descriptive with anonymized data collection and data analysis. Therefore, the study adds no risk to the study population.
Ethics:
The "Pace-Conduct" study has been approved by the responsible ethics committee of the Friedrich- Alexander University Erlangen, Germany (145_20 Bc)
- Conditions
- Pacemaker DDD, His Bundle Pacing, LBB Area Pacing, Pacing-Induced Cardiomyopathy, Left Bundle-Branch Block, ICD
- Being tested
- cardiac implantable electronic device (CIED) implantation
- Keywords
- His bundle pacing, LBB area pacing, cardiac resynchronisation therapy
- Medical subject headings
- Bundle-Branch Block
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
cardiac implantable electronic device (CIED) implantationDevice
CIED Implantation according to the Guidelines aiming to avoid pacing induced dyssynchrony
| Study group | Role | What they receive |
|---|---|---|
| CIED for cardiac resynchronisation | Patients implanted with an CIED for cardiac resynchronisation aiming to avoid pacing induced ventricular dyssynchrony, e.g. His bundle pacing, LBB-area pacing, CRT. These different implanted types of devices may be further analysed as subgroups. Receives: Device: cardiac implantable electronic device (CIED) implantation |
What is being measured
The primary outcome is the main question the study is designed to answer.
CIED Implantation success
successful Pacemaker- or ICD implantation with effective pacing and acceptable pacing threshold in the targeted area
Measured: peri-procedural
Secondary outcomes (5)
pre-operative: Implantation related Patient characteristics
association with procedural and post-implant outcome
Measured: 1 month post implantation
intra-procedural: implant success related with procedural characteristics
correlation of Implantation success with Patient characteristics and procedural technical Parameter, eg. use of an electroanatomic mapping system
Measured: peri-procedural
peri-procedural: safety and radiation
Radiation exposure and number and type of all adverse Events and adverse device associated events
Measured: peri-procedural
follow-up: device function
device parameter and programming during follow up
Measured: one year
follow-up: outcome
clinical Outcome during follow up
Measured: one year
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted4 Jun 2020
- Study start1 Jan 2018
- Primary completion31 Dec 2025 (estimated)
- Study completion31 Dec 2030 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (1)Papers the sponsor has linked to this study.
- Other trials for Pacemaker DDDStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 200 participants (estimated)
- Target duration
- 1 Year
Sponsor and investigators
- Lead sponsor
- Klinikum-Fuerth
- Sponsor type
- University, hospital or other
- Collaborators
- University of Erlangen-Nürnberg, University of Trieste
- Responsible party
- Sponsor
- Investigators
- Dirk Bastian, MD, Principal investigator, Klinikum-Fuerth
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04416958
- Sponsor's protocol ID
- Pace_Cond_KHF
- Acronym
- Pace-Conduct
- Status last verified
- Oct 2024
- First submitted
- 1 Jun 2020
- Last updated
- 15 Oct 2024
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Bastian D, Gregorio C, Buia V, Walaschek J, Rittger H, Vitali-Serdoz L. His bundle pacing guided by automated intrinsic morphology matching is feasible in patients with narrow QRS complexes. Sci Rep. 2022 Mar 4;12(1):3606. doi: 10.1038/s41598-022-07516-6.
PubMed 35246595
Study at a glance
From the registry record, last updated by the sponsor on 15 Oct 2024. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Pacing for Cardiac Resynchronisation Using the Intrinsic Conduction System to Maintain Physiologic Ventricular Activation
- ClinicalTrials.gov ID
- NCT04416958
- Acronym / sponsor ID
- Pace-Conduct / Pace_Cond_KHF
- Conditions
- Pacemaker DDD, His Bundle Pacing, LBB Area Pacing, Pacing-Induced Cardiomyopathy, Left Bundle-Branch Block, ICD
- Keywords
- His bundle pacing, LBB area pacing, cardiac resynchronisation therapy
- Study type
- Observational
- Recruitment status
- Recruiting
- Enrolment
- 200 participants (estimated)
- Lead sponsor
- Klinikum-FuerthUniversity, hospital or other
- Collaborators
- University of Erlangen-Nürnberg, University of Trieste
- Study start
- 1 Jan 2018 (actual)
- Primary completion
- 31 Dec 2025 (estimated)
- Study completion
- 31 Dec 2030 (estimated)
- First posted
- 4 Jun 2020 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Right ventricular pacing causes ventricular dyssynchrony and may be associated with impaired outcome. In the last decade, several approaches for more physiological pacing became available and were implemented in the latest guidelines. However, compared to conventional device implantation, cardiac resynchronization, His bundle pacing and left bundle area pacing remain demanding procedures in the individual case. Goal of the single center observational "Pace conduct" study is to evaluate implantation success, safety and outcome of pacing methods that maintain physiologic ventricular activation.
Detailed description
Background:
Conventional ectopic myocardial right ventricular pacing (RVP) causes ventricular dyssynchrony and may be associated with reverse ventricular remodeling, reduced ejection fraction (EF), left ventricular dilatation, functional mitral valve regurgitation, heart failure and an increased rate of new onset atrial fibrillation.
Dependent on individual patient's characteristics, several strategies are established to prevent and to overcome the potential drawbacks of chronic RVP. In general, unnecessary ectopic RVP should be avoided. For example, in patients with sinus node disease and intact atrioventricular (AV) conduction, atrial pacing, AV (search) hysteresis or AAI-DDD/ADI pacing may be used. In patients with impaired cardiac function and an expected higher percentage of RVP, pacing strategies for cardiac resynchronization are indicated. Conventional cardiac resynchronization therapy (CRT) uses an additional transvenous left ventricular lead for synchronous ventricular stimulation and was shown to shorten QRS duration and to reduce morbidity and mortality in patients with chronic heart failure, left bundle branch block (LBBB) and reduced EF. Due to the non-physiological left ventricular epicardial stimulation, however, conventional CRT is associated with 30% of non-responders and may even prolong ventricular activation in patients with narrower QRS complex. First described in 1968, His bundle pacing (HBP) has evolved to an increasingly used alternative for cardiac pacing. Currently, HBP is regarded the most physiologic approach for ventricular stimulation because it prevents ventricular dyssynchrony and its potential fatal long-term consequences by preserving normal electrical activation of the ventricles. Clinical benefit of HBP has been shown compared with conventional permanent RVP and CRT. Recent studies documented restoration of normal electrical and mechanical left ventricular synchrony for both selective and non-selective HBP. However, compared with conventional RVP the implantation procedure for HBP is much more demanding requiring exact placement of the pacing lead within the anatomically variable His bundle area. Alternatively, the correction of bundle branch conduction disorders has been demonstrated for left bundle branch area (LBBA) pacing. As a consequence, current guidelines recommend pacing methods that maintain physiologic ventricular activation in patients with atrioventricular block who have an indication for permanent pacing with a LVEF between 36% and 50% and are expected to require ventricular pacing more than 40% of the time (class IIa indication).
In summary, there is increasing evidence showing the benefits of the different strategies for physiologic pacing but the appropriate use of these approaches may be challenging in the individual case. Therefore, appropriate patient selection, implantation approaches, device programming and follow-up require further intensive evaluation.
Objective:
Main goal of the study is to evaluate implantation success for pacing methods aiming to maintain physiologic ventricular activation. Procedural success is defined as stable lead positioning and effective pacing within the target area with an appropriate and stable pacing threshold.
Secondary goals of the study are to document and to evaluate
- procedural parameters (e.g. venous access, time needed for lead implant, procedural duration, radiation) and adverse events dependent on procedural approaches and patients characteristics,
- performance of the implanted system (sensing, pacing thresholds) and clinical outcome during routine follow-up
Study design:
Single center, non-randomized, observational study, retrospective data analysis, on-going prospective patient enrollment, descriptive statistics.
Center: Klinikum Fuerth (Dept. for Heart and Lung diseases, section for clinical electrophysiology) / Germany in cooperation with the Dept. of Cardiology of the University Erlangen / Germany and the University of Trieste / Italy.
Patients and methods:
Primary endpoint: Implantation success. Effective pacing and acceptable pacing threshold at the targeted lead position. Target for lead placement is the area with maximum delayed ventricular activation for transvenous CRT, the His bundle for selective or non-selective HBP and the right interventricular septum with left bundle branch capture for LBBA pacing, respectively. Target thresholds for the lead placed within the coronary sinus or at the intrinsic conduction system is <2.5 V @ 1 ms with a maximum acceptable threshold of <4.0 V @ 2 ms or <5 V @ 1 ms. Target for all other leads is <1 V @ 0.5 ms.
Secondary endpoints: patient characteristics and association with outcome. Implantation success and outcome correlated with patient characteristics including electrocardiogram and echocardiographic parameter and procedure related techniques and parameter. Safety: radiation exposure, number and type of adverse events and adverse device related events. Follow-up: device function, interrogation, programming and clinical outcome as evaluated in routine follow-up, incl. ECG, echocardiography and parameter for assessment of heart failure. Subpopulations: managed ventricular pacing, His bundle pacing, LBB-area pacing, CRT. Implantation with or without electroanatomic mapping system.
Inclusion criteria:
Implantation of a pacemaker or ICD according to the current guidelines (Class I or IIa indication) aiming to avoid pacing induced dyssynchrony, e.g. managed ventricular pacing, His-bundle pacing, LBB-area pacing or conventional transvenous CRT. Age ≥ 18 years.
Exclusion criteria:
No given informed consent for the procedure. No follow up data available.
Sample size:
For the observational study, there is no pre-specified sample-size. Data from 200 patients and procedures are expected.
Data security:
Study related data are collected by the study investigators in an anonymous clinic-internal data-base that is password protected. All investigators have to provide valid GCP training.
Risk estimation:
The study is observational and descriptive with anonymized data collection and data analysis. Therefore, the study adds no risk to the study population.
Ethics:
The "Pace-Conduct" study has been approved by the responsible ethics committee of the Friedrich- Alexander University Erlangen, Germany (145_20 Bc)
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
- Target follow-up
- 1 Year
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| CIED for cardiac resynchronisation | – | Device: cardiac implantable electronic device (CIED) implantationPatients implanted with an CIED for cardiac resynchronisation aiming to avoid pacing induced ventricular dyssynchrony, e.g. His bundle pacing, LBB-area pacing, CRT. These different implanted types of devices may be further analysed as subgroups. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- Patients undergoing Pacemaker or ICD Implantation according to current Guidelines with the aim to avoid pacing induced ventricular dyssynchrony. Subgroups according to type of device implanted, lead Position and programming.
Key inclusion criteria (2 listed)
- Pacemaker or ICD Implantation aiming to avoid pacing induced ventricular dyssynchrony according to current guidelines
- age >= 18 years
Key exclusion criteria (2 listed)
- no informed consent for the procedure given
- no follow-up data
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| cardiac implantable electronic device (CIED) implantationCIED Implantation according to the Guidelines aiming to avoid pacing induced dyssynchrony | Device | CIED for cardiac resynchronisation |
Primary outcome
CIED Implantation success
Time frame: peri-procedural
successful Pacemaker- or ICD implantation with effective pacing and acceptable pacing threshold in the targeted area
5 secondary outcomes
pre-operative: Implantation related Patient characteristics
Time frame: 1 month post implantation
intra-procedural: implant success related with procedural characteristics
Time frame: peri-procedural
peri-procedural: safety and radiation
Time frame: peri-procedural
follow-up: device function
Time frame: one year
follow-up: outcome
Time frame: one year
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 15 Oct 2024.
- Derived from this study: PubMed 35246595Bastian D, Gregorio C, Buia V, Walaschek J, Rittger H, Vitali-Serdoz L. His bundle pacing guided by automated intrinsic morphology matching is feasible in patients with narrow QRS complexes. Sci Rep. 2022 Mar 4;12(1):3606. doi: 10.1038/s41598-022-07516-6.
- Individual participant dataSharing planned: No
Related trials for Pacemaker DDD
RecruitingObservational study
Prospective Database for Prediction of Atrial Fibrillation in Pacemaker and ICD Patients
Atrial Fibrillation, Pacemaker Ddd
RecruitingObservational study
Non-Invasive Method for Evaluation of Cardiac Resynchronization Therapy
Heart Failure, Pacemaker DDD
RecruitingObservational study
Left Bundle Branch Area Mapping for Conduction System Pacing
Left Bundle-Branch Block, Pacemaker DDD
Recruiting
Conduction System Pacing With Left Bundle Branch Pacing as Compared to Standard Right Ventricular Pacing
Pacemaker DDD, Heart Block
Recruiting
Remote Alert Pathway To Optimize CaRe of Cardiac Implantable Electrical Devices
Pacemaker DDD, Implantable Defibrillator User
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Dirk Bastian, MD principal investigator
Klinikum-Fuerth
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Pacemaker DDD and His Bundle Pacing, run by Klinikum-Fuerth at 1 site in Germany.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 15 Oct 2024. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Dirk Bastian, MD (+49 911 7580 1101, dirk.bastian@klinikum-fuerth.de), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
CIED Implantation success (time frame: peri-procedural). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT04416958, which also lists 1 linked publication.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 Oct 2024; AzTrials last refreshed its copy on 27 Oct 2026.