Upper Airway ObstructionNCT04419883
A New Flexible Extended-Length Pharyngeal Airway for Deep Sedation
An observational study of Upper Airway Obstruction, run by McMurray Medical Group, LLC at 1 site in United States.
Trial summary
The purpose of this prospective pilot provider adoption study was to evaluate user experience a new airway device in adult patients with airway obstruction under deep sedation. Fifteen hospital systems served as testing sites. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Upper Airway Obstruction
- What is being tested?
- McMurray Enhanced Airway
- Type of treatment
- Medical device
- How many people
- 86 participants
- Where
- 1 siteUnited States
- Study dates
- 5 Mar 2019to 5 May 2020
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- Adult, Older adult
Study population: Anesthesia providers who volunteered to trial this new airway device were recruited to complete a survey tool to assess provider satisfaction of a commercially-available upper airway device (McMurray Enhanced Airway (MEA); McMurray Medical, Minneapolis, MN).
Who may be able to join
- 18 years of age and older
- Scheduled for surgery with sedation/MAC anesthesia
- Patients experiencing an obstructive airway needing an airway device placed
Who cannot join
- Inappropriate airway device size, too big or too small
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Provider Satisfaction of a New, Flexible Extended-Length Pharyngeal Airway to Relieve Upper Airway Obstructive During Deep Sedation: A Pilot Study
The purpose of this prospective pilot provider adoption study was to evaluate user experience a new airway device in adult patients with airway obstruction under deep sedation. Fifteen hospital systems served as testing sites. Fifty-four anaesthetist providers reported their experience with the airway device in 84 cases across two phases of surveying.
Read the detailed description
This multi-center proof-of-concept, descriptive, prospective, and observational study was approved by a universal Institutional Review Board (IRB) for Human Subjects Research in March 2019. Anaesthesia providers who volunteered to trial this new airway device were recruited to complete a survey tool to assess provider satisfaction of a commercially-available upper airway device (McMurray Enhanced Airway (MEA); McMurray Medical, Minneapolis, MN).
The MEA is a novel upper airway device with numerous enhanced features relative to currently available airway management products (Figure 1). The MEA has longer flexible tubing allowing for displacement of pharyngeal tissue that oral airways are unable to reach, and avoiding the need for chin lift/jaw thrust maneuvers [16]. The smaller diameter helps reduce stimulation and gagging and permits placement alongside an endoscopy bite block. The softer material, similar to that of a nasal airway, allows for ease of insertion and reduces potential oral injury associated with hard plastic oral airways [16]. An elongated cushioned bite block is designed to prevent proximal airway collapse, allow flexibility of molar placement, and decrease the risk of dental damage [16]. An optional connector can be connected to an anesthesia circuit or manual resuscitator, facilitating intraoral ventilation and aiding in situations such as difficult mask ventilation or when oxygen diffusion in the surgical field may present fire risk [16]. Furthermore, the MEA was designed to reduce need for manual stationary maneuvers by providers such as chin lift or jaw thrust, thereby preventing potential provider-patient exposure of airborne droplets and increased staffing.
Providers received device instructions for use (IFU) by training video and printed material to understand how to use and size the MEA. After using the MEA trial device in clinical practice, anaesthesia providers participated in completing the Use Survey Tool based on cases meeting the following criteria: inclusion criteria included adult patients (age >18) experiencing an obstructive airway under deep sedation; exclusion criteria included determining that the device size was inappropriate-too big or small-for the patient, since placing an improper size could be detrimental for the patient.
The initial survey(Phase 1) was developed to evaluate current product usage, general use conditions, deep sedation conditions, general anaesthesia conditions, device performance, and overall device satisfaction using binary responses with option for subjective free response. Based on Phase 1 responses and provider feedback, Phase 2 surveys were limited to questions with ordinal responses that assessed device use satisfaction during deep sedation procedures only. Surveys were distributed with the trial devices. As this was a pilot feasibility study for the new extended pharyngeal airway device, recruitment of provider subjects was based on interest of using a novel airway device to benefit airway management when providing deep sedation in situations where airway obstruction became problematic. Surveys were voluntarily completed by the anaesthesia provider following each use. One provider could complete multiple surveys to represent individual device performance and experience. Information related to patient, provider, and device placement frequency was not collected in order to expedite response rate to learn initial provider experience. Submitted surveys underwent response analysis by an independent statistician. Due to the nature of qualitative data, descriptive statistics were used to summarize study results. No objective measures of device clinical efficacy were collected.
- Conditions
- Upper Airway Obstruction
- Being tested
- McMurray Enhanced Airway
- Keywords
- Upper airway obstruction, Airway management tools, Airway complications, Deep sedation, Deep monitored anaesthesia care (MAC)
- Medical subject headings
- Airway Obstruction
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
McMurray Enhanced AirwayDevice
Also called MEA
Provider Satisfaction of a New, Flexible Extended-Length Pharyngeal Airway to Relieve Upper Airway Obstructive During Deep Sedation: A Pilot Study
| Study group | Role | What they receive |
|---|---|---|
| Anesthesia Providers | Anesthesia providers from 15 different health care facilities in the United States. Receives: Device: McMurray Enhanced Airway |
What is being measured
The primary outcome is the main question the study is designed to answer.
Evaluate the new, flexible extended-length pharyngeal airway ease of use
The question asked: With the curve end facing the hard palate, how easy was the MEA to place? Four response options on measurement tool to assess outcomes: Easy, Moderate, Difficult, Not Successful
Measured: Survey was completed immediately after completion of surgery and airway use
Assess the new, flexible extended-length pharyngeal ability to relieve an upper airway obstruction
Two response options on measurement tool to assess outcomes: Yes and No
Measured: Survey was completed immediately after completion of surgery and airway use
Assess if the new airway allowed a "hands off approach" when the patient was under deep sedation/MAC anesthesia
Three response options on measurement tool to assess outcomes: Yes, No, Not sure
Measured: Survey was completed immediately after completion of surgery and airway use
Secondary outcomes (1)
Provider satisfaction with the new, flexible extended-length pharyngeal airway.
Five response options on measurement tool to assess outcomes: Very Satisfied, Somewhat Satisfied, Satisfied, Dissatisfied, I did not use the MEA for deep MAC
Measured: Survey was completed immediately after completion of surgery and airway use
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted9 Jun 2020
- Study start5 Mar 2019
- Primary completion5 Mar 2020
- Study completion5 May 2020
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Upper Airway ObstructionStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 86 participants (actual)
Sponsor and investigators
- Lead sponsor
- McMurray Medical Group, LLC
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Principal investigator, Roxanne R McMurray, McMurray Medical Group, LLC
- Investigators
- Roxanne McMurray, DNP, Principal investigator, McMurray Medical Group, LLC
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04419883
- Sponsor's protocol ID
- MEA-001-01
- Status last verified
- Jun 2020
- First submitted
- 29 May 2020
- Last updated
- 9 Jun 2020
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No: No individual participant data was collected for this study
Study at a glance
From the registry record, last updated by the sponsor on 9 Jun 2020. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Provider Satisfaction of a New, Flexible Extended-Length Pharyngeal Airway to Relieve Upper Airway Obstructive During Deep Sedation: A Pilot Study
- ClinicalTrials.gov ID
- NCT04419883
- Acronym / sponsor ID
- MEA-001-01
- Conditions
- Upper Airway Obstruction
- Keywords
- Upper airway obstruction, Airway management tools, Airway complications, Deep sedation, Deep monitored anaesthesia care (MAC)
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 86 participants (actual)
- Lead sponsor
- McMurray Medical Group, LLCIndustry (pharma, biotech, devices)
- Study start
- 5 Mar 2019 (actual)
- Primary completion
- 5 Mar 2020 (actual)
- Study completion
- 5 May 2020 (actual)
- First posted
- 9 Jun 2020 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of this prospective pilot provider adoption study was to evaluate user experience a new airway device in adult patients with airway obstruction under deep sedation. Fifteen hospital systems served as testing sites. Fifty-four anaesthetist providers reported their experience with the airway device in 84 cases across two phases of surveying.
Detailed description
This multi-center proof-of-concept, descriptive, prospective, and observational study was approved by a universal Institutional Review Board (IRB) for Human Subjects Research in March 2019. Anaesthesia providers who volunteered to trial this new airway device were recruited to complete a survey tool to assess provider satisfaction of a commercially-available upper airway device (McMurray Enhanced Airway (MEA); McMurray Medical, Minneapolis, MN).
The MEA is a novel upper airway device with numerous enhanced features relative to currently available airway management products (Figure 1). The MEA has longer flexible tubing allowing for displacement of pharyngeal tissue that oral airways are unable to reach, and avoiding the need for chin lift/jaw thrust maneuvers [16]. The smaller diameter helps reduce stimulation and gagging and permits placement alongside an endoscopy bite block. The softer material, similar to that of a nasal airway, allows for ease of insertion and reduces potential oral injury associated with hard plastic oral airways [16]. An elongated cushioned bite block is designed to prevent proximal airway collapse, allow flexibility of molar placement, and decrease the risk of dental damage [16]. An optional connector can be connected to an anesthesia circuit or manual resuscitator, facilitating intraoral ventilation and aiding in situations such as difficult mask ventilation or when oxygen diffusion in the surgical field may present fire risk [16]. Furthermore, the MEA was designed to reduce need for manual stationary maneuvers by providers such as chin lift or jaw thrust, thereby preventing potential provider-patient exposure of airborne droplets and increased staffing.
Providers received device instructions for use (IFU) by training video and printed material to understand how to use and size the MEA. After using the MEA trial device in clinical practice, anaesthesia providers participated in completing the Use Survey Tool based on cases meeting the following criteria: inclusion criteria included adult patients (age >18) experiencing an obstructive airway under deep sedation; exclusion criteria included determining that the device size was inappropriate-too big or small-for the patient, since placing an improper size could be detrimental for the patient.
The initial survey(Phase 1) was developed to evaluate current product usage, general use conditions, deep sedation conditions, general anaesthesia conditions, device performance, and overall device satisfaction using binary responses with option for subjective free response. Based on Phase 1 responses and provider feedback, Phase 2 surveys were limited to questions with ordinal responses that assessed device use satisfaction during deep sedation procedures only. Surveys were distributed with the trial devices. As this was a pilot feasibility study for the new extended pharyngeal airway device, recruitment of provider subjects was based on interest of using a novel airway device to benefit airway management when providing deep sedation in situations where airway obstruction became problematic. Surveys were voluntarily completed by the anaesthesia provider following each use. One provider could complete multiple surveys to represent individual device performance and experience. Information related to patient, provider, and device placement frequency was not collected in order to expedite response rate to learn initial provider experience. Submitted surveys underwent response analysis by an independent statistician. Due to the nature of qualitative data, descriptive statistics were used to summarize study results. No objective measures of device clinical efficacy were collected.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Anesthesia Providers | – | Device: McMurray Enhanced AirwayAnesthesia providers from 15 different health care facilities in the United States. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Age groups
- Adult, Older adult
- Study population
- Anesthesia providers who volunteered to trial this new airway device were recruited to complete a survey tool to assess provider satisfaction of a commercially-available upper airway device (McMurray Enhanced Airway (MEA); McMurray Medical, Minneapolis, MN).
Key inclusion criteria (3 listed)
- 18 years of age and older
- Scheduled for surgery with sedation/MAC anesthesia
- Patients experiencing an obstructive airway needing an airway device placed
Key exclusion criteria (1 listed)
- Inappropriate airway device size, too big or too small
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| McMurray Enhanced AirwayAlso: MEAProvider Satisfaction of a New, Flexible Extended-Length Pharyngeal Airway to Relieve Upper Airway Obstructive During Deep Sedation: A Pilot Study | Device | Anesthesia Providers |
Primary outcome
Evaluate the new, flexible extended-length pharyngeal airway ease of use
Time frame: Survey was completed immediately after completion of surgery and airway use
The question asked: With the curve end facing the hard palate, how easy was the MEA to place? Four response options on measurement tool to assess outcomes: Easy, Moderate, Difficult, Not Successful
Assess the new, flexible extended-length pharyngeal ability to relieve an upper airway obstruction
Time frame: Survey was completed immediately after completion of surgery and airway use
Two response options on measurement tool to assess outcomes: Yes and No
Assess if the new airway allowed a "hands off approach" when the patient was under deep sedation/MAC anesthesia
Time frame: Survey was completed immediately after completion of surgery and airway use
Three response options on measurement tool to assess outcomes: Yes, No, Not sure
1 secondary outcome
Provider satisfaction with the new, flexible extended-length pharyngeal airway.
Time frame: Survey was completed immediately after completion of surgery and airway use
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 9 Jun 2020.
- Individual participant dataSharing planned: No. No individual participant data was collected for this study
Related trials for Upper Airway Obstruction
Not yet recruiting
Influence of Patient Positioning During Nasal Lavage
Acute Upper Respiratory Tract Infections, Nasal Obstruction
Not yet recruitingObservational study
Post-market Clinical Follow-up Study of an Isotonic Saline Solution for the Relief of Nasal Congestion in Infants and Toddlers
Nasal Congestion, Common Cold
Enrolling by invitationObservational study
Difficult Airway Management in Oncology: An International Delphi Consensus Study (DAMO)
Neoplasms, Airway Obstruction Upper
Not yet recruiting
Asthma Lung Sounds With Wearable Stethoscope
Asthma, Pediatric Asthma
Recruiting
Self-Supporting Nasopharyngeal Airway (ssNPA) Treating Upper Airway Obstruction in Hypotonia
Obstructive Sleep Apnea, Hypertonia, Muscle
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Roxanne McMurray, DNP principal investigator
McMurray Medical Group, LLC
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Upper Airway Obstruction, run by McMurray Medical Group, LLC at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 9 Jun 2020. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Evaluate the new, flexible extended-length pharyngeal airway ease of use (time frame: Survey was completed immediately after completion of surgery and airway use). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Jun 2020.