Brugada Syndrome 1SDE-08-16NCT04504591

Validation Of A New S-ICD Algorithm To Reduce Oversensing Of Dynamic T-Waves In Patients With Brugada Syndrome

An observational study of Brugada Syndrome 1S, run by Angelo Auricchio at 6 sites in 3 countries.

Terminated

Stopped early. The study ended before it was planned to and will not resume.

Official record
Search all trials

Trial summary

The main objective of this study will be to assess the efficacy of S-ICD with SMART Pass to discriminate dynamic T-waves amplitudes and morphologies over time. Pilot, multi-centric, prospective, blinded, one arm (repeated measures), non-interventional study. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Brugada Syndrome 1S
How many people
126 participants
Where
6 sitesin 3 countries
Study dates
14 Dec 2017to 30 Jun 2020
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Consecutive patients with suspected BrS will be submitted for routine diagnostic ajmaline testing.

Who may be able to join

  • Male and/or female subjects beyond the ages of ≥18 the time of informed consent;
  • Subjects with suspected BrS;

Who cannot join

  • Presence of baseline Brugada type I ECG
  • Presence of structural cardiac abnormalities

Trial locations and contacts

6 sites in 3 countries.

6 sites in 3 countries

Italy3 sites
  • Azienda Ospedaliera Brotzu

    Cagliari, 09134

  • ATS Sardegna Ospedale San Francesco-ASSL 3 NUORO

    Nuoro, 08100

  • Fondazione I.R.C.C.S. Policlinico San Matteo di Pavia

    Pavia, 27100

Other trials in Italy

Switzerland2 sites
  • Hopitaux Universitaires de Genève

    Geneva, CH - 1205

  • Fondazione Cardiocentro Ticino

    Lugano, CH-6900

Other trials in Switzerland

Belgium1 site
  • UZ-VUB Brussels

    Brussels, B1090

Other trials in Belgium

About this study

The main objective of this study will be to assess the efficacy of S-ICD with SMART Pass to discriminate dynamic T-waves amplitudes and morphologies over time.

Pilot, multi-centric, prospective, blinded, one arm (repeated measures), non-interventional study. Objective is to setup a 8-center data collection registry between Switzerland, Italy and Belgium.

Read the detailed description

The subcutaneous implantable cardioverter-defibrillator (S-ICD) should be considered as an alternative to transvenous defibrillators in patients with an ICD indication when pacing therapy for bradycardia support, cardiac resynchronization or ventricular tachycardia management is not necessary.1 This class IIa recommendation from the 2015 ESC guidelines can often be applied to patients with inherited channelopathies, since these patients usually require decades of ICD therapy without developing a need for any type of pacing support. On the other hand, especially in patients with Brugada Syndrome (BrS), the dynamic nature of ECG morphology may increase the risk for cardiac T-wave oversensing (TWOS), which has also been reported the main cause of inappropriate shocks (IAS) in the general S-ICD population. In order to avoid unnecessary sensing issues with the S-ICD, baseline ECG screening is recommended prior to the implantation procedure. Recently, it has been shown that eligibility failure for S-ICD can occur in up to 13% of patients with an inherited primary arrhythmia syndrome and that patients with BrS present the highest rate of screening failure if compared with other channelopathies.

As of yet, this QRS and T-wave morphology assessment can be done with an algorithm-based automated screening tool (AST) that mimics the sensing set-up process of the S-ICD after implant.

Recently, a novel 9Hz high-pass filter (SMART Pass, available for all EMBLEM S-ICD models) has been introduced to reduce the risk of TWOS with the S-ICD12. This algorithm is only available with the S-ICD sensing mechanism and has not been incorporated in the automated screening software12. Retrospective modelling of inappropriate shock events recorded in the EFFORTLESS registry have shown a reduction in inappropriate shocks by ~80% with SMART Pass compared to the first generation sensing algorithm of the S-ICD13. This was achieved without affecting the detection and the time to therapy for true ventricular arrhythmias.

Prospective data are lacking about the effectiveness of SMART Pass to discriminate T-waves in patients with dynamic ECG morphologies. This may be of particular interest since the occurrence of ECG morphology disturbances is usually difficult to be predicted in individual patients. As such, these data will provide additional guidance to the mandatory screening process for all S-ICD candidates, in particular for those who have a known risk factor for dynamic ECG changes, like patients withBrS. The main objective of this study will be to assess the efficacy of S-ICD with SMART Pass to discriminate dynamic T-waves amplitudes and morphologies over time.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Rate of S-ICD screening failure due to TWOS with and without SMART Pass in patients with ajmaline-induced Brugada Type I ECG.

    Rate of S-ICD screening failure due to TWOS after ajmaline challenge with and without SMART Pass in patients with Ajmaline induced Brugada type I ECG.

    Measured: through study completion, an average of 15 months

Secondary outcomes (1)
  1. Rate of S-ICD screening failure with and without SMART Pass in the patients without ajmaline-induced Brugada type-I ECG who manifest a conduction disturbance (i.e. RBBB).

    Rate of S-ICD screening failure due to TWOS after ajmaline challenge with and without SMART Pass in patients without Brugada type I EC but with Ajmaline induced ECG conduction disturbances.

    Measured: through study completion, an average of 15 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted7 Aug 2020
  2. Study start14 Dec 2017
  3. Primary completion28 Feb 2020
  4. Study completion30 Jun 2020

Why it stopped: Early termination due to COVID19; preliminary data can be considered significant

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Other
Time perspective
Prospective
Enrolment
126 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04504591
Sponsor's protocol ID
DE-08-16
Acronym
DE-08-16
Status last verified
Aug 2020
First submitted
30 Jul 2020
Last updated
7 Aug 2020
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No

Publications

  • Conte G, Cattaneo F, de Asmundis C, Berne P, Vicentini A, Namdar M, Scalone A, Klersy C, Caputo ML, Demarchi A, Ozkartal T, Salghetti F, Casu G, Passarelli I, Mameli S, Shah D, Burri H, De Ferrari G, Brugada P, Auricchio A. Impact of SMART Pass filter in patients with ajmaline-induced Brugada syndrome and subcutaneous implantable cardioverter-defibrillator eligibility failure: results from a prospective multicentre study. Europace. 2022 May 3;24(5):845-854. doi: 10.1093/europace/euab230.

    PubMed 34499723

Questions about this trial

What is this clinical trial studying?

An observational study of Brugada Syndrome 1S, run by Angelo Auricchio at 6 sites in 3 countries.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: stopped early, as of the sponsor's last update on 7 Aug 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 6 sites in Italy, Switzerland, Belgium. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study was stopped early (reason given: Early termination due to COVID19; preliminary data can be considered significant). Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Rate of S-ICD screening failure due to TWOS with and without SMART Pass in patients with ajmaline-induced Brugada Type I ECG. (time frame: through study completion, an average of 15 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04504591, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 7 Aug 2020.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in