Transcutaneous Continuous Hemoglobin MeasurementSpHbNCT04506957

Non-invasive Continuous Total Hemoglobin Measurement by Pulse CO-Oximetry

An observational study of Transcutaneous Continuous Hemoglobin Measurement, run by Klinik Hirslanden, Zurich.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

This study is a data collection/sampling project for transcutaneous continuous Pulse CO-Oximetry and accessories (SW-Version Radical-7® Pulse CO-Oximeter with the Masimo rainbow SETTM, V1.6.2.4i Masimo Corp., Irvine, CA, USA, and the RD rainbow SET-2, Rev-O Fingersensor). Read more about this study

Who is it for?
Ages 18 to 90 years
What is being tested?
Pulse CO-Oximetry Hemoglobin measurement transcutaneous
Type of treatment
Medical device
How many people
50 participants
Where
No sites listed yet
Study dates
1 Dec 2020to 30 Jun 2022
How long will I take part?
2 Years
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 90 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Patients scheduled for major spine surgery

Who may be able to join

  • Patients scheduled for major spine surgery
  • Written consent of the participation after clarification about the study

Who cannot join

  • No consent to participate
  • No German comprehension
  • Black skin patients
  • Patients with COVID-19 illness

Trial locations and contacts

No sites are listed yet.

About this study

Official title: Non-invasive Continuous Total Hemoglobin Measurement by Pulse CO-Oximetry in Major Spine Surgery

This study is a data collection/sampling project for transcutaneous continuous Pulse CO-Oximetry and accessories (SW-Version Radical-7® Pulse CO-Oximeter with the Masimo rainbow SETTM, V1.6.2.4i Masimo Corp., Irvine, CA, USA, and the RD rainbow SET-2, Rev-O Fingersensor). The device received the CE Mark in 2012 and is approved by the Swiss Medic for clinical use. The Radical-7 device isolates multiple (7+) wavelengths of light of arterial signals using adaptive filters. It provides continuous noninvasive monitoring of arterial oxygen saturation (RadSpO2), pulse rate (RadPR), carboxyhaemoglobin saturation (SpCO), methaemoglobin saturation (SpMET), total haemoglobin concentration in g/dl (SpHb) and/or respiration rate (RRa). Additionally, Low Signal IQ (Low SIQ), Perfusion Index (PI), Pleth Variability Index (PVI), total arterial oxygen content (SpOC), Haematocrit (SpHCT), Signal identification Quality (SIQa), Respiration Indicator (RI) are displayed.The purpose of this prospective study is to investigate the reliability of non-invasive continuously measured SpHb by the Masimo Radical-7® Pulse co-oximeter (Radical 7 device) under steady state conditions by comparison against simultaneously invasive measured arterial haemoglobin concentrations (CoOxHb) in major spine surgery patients, in which high blood loss was expected

Read the detailed description

The objective of this investigation is the comparison of CoOxHb, HCT and SaO2 values of a blood gas analyzer (ABL 825, Radiometer Medical A/S) with simultaneously measured SpHb values of the Radical 7 device during the procedure of major spine surgery.

The primary endpoint of the study is the reliability of SpHb to detect CoOxHb and its changes during the process Secondary endpoint is the reliability of RadSpO2, RadPR, SpHCT and SpMET to detect SaO2, PR, HCT and MetHb and its changes during the process.

Inclusion criteria:

  1. Patients scheduled for major spine surger
  2. Age 18 years and older
  3. Written consent of the participation after clarification about the study

Exclusion criteria:

  1. No consent to participate
  2. No German comprehension
  3. Black skin patients
  4. Patients with COVID-19 illness All patients were monitored based on the institutional routine monitoring for major spine surgery (continuous 2-channel electrocardiogram, a continuous invasive arterial blood pressure monitoring via fluid-filled cather system, inserted in the radial artery mainly of the non-dominant hand, SpO2, and in the case of high-risk patient a triple-lumen central venous line). Then a single use finger sensor (MasimoSet RD rainbow SET SpHb SpMet-Sensor) is attahed to the ring finger of the hand, where the catheter is introduced in the radial artery.

During the surgery routinely, arterial blood samples are drawn before induction of Anaesthesia, every 45 min and after acute blood loss during surgery. With each blood sample for a blood gas analysis the SpHb, SpMet, PI, PVI and the low SQI are recorded.

No additional blood sampling is necessary to perfom this investigation

50 patients will be included and the duration of the study is 24 month's Sample size calculation was performed with the StatsDirect Statistical Software Version 2.8.0 2013 (StatsDirect Ltd, Altrincham, UK) and revealed a sample size of 95 paired SpHb and CoOxHb measurements to achieve a power of 0.9, α = 0.05 to detect a mean difference (bias) of CoOxHb and SpHb of 0.50 g/dl with an estimated standard deviation (SD) of 1.0g/dl. The mean difference is determined based on previous investigations. Continuous variables are tested for normal distribution with the Kolmogorov-Smirnow test. Normally distributed data are expressed as mean ± standard deviation (SD); median, interquartile range (IQR ; 25th to 75th percentile) and [maximum] are specified when the data were not normally distributed. Categorical variables are presented as number and percentage (%). For subgroup analysis continuous variables are compared using the t-test or Mann-Whitney U test, when appropriate. All tests are two-sided and a P-value < 0.05 was determined to be significant.

For all determinants that might have an impact on the fault detection of the SpHb stepwise multiple regressions analysis was performed. Correlation is evaluated by Spearman rank test. To determine agreement of the methods, the Bland Altman analysis for repeated measurements is performed for SpHb and CoOcHb.

Being tested
Pulse CO-Oximetry Hemoglobin measurement transcutaneous

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Pulse CO-Oximetry Hemoglobin measurement transcutaneousDevice

    Also called interventions are only performed based on co-oximetry hemoglobin measurement using a blood gas analyzer

    this is an observational Investigation, in which transcutaneous continuous hemoglobin detection using Pulse-CO-Oximetry is compared with co-oximetrically measured Hemoglobin using a blood gas analyzer device

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Reliability of SpHb to detect CoOxHb and its changes

    Co-oximetry hemoglobin values from blood gas analyzer is simultaneous compared with the transcutaneous detected SpHb (Pulse CO-Oximetry hemoglobin measurement). Linear correlation and Bland Altman Analysis are performed for analysis these data pairs

    Measured: 24 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted10 Aug 2020
  2. Study start1 Dec 2020 (estimated)
  3. Primary completion31 Dec 2021 (estimated)
  4. Study completion30 Jun 2022 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case only
Time perspective
Prospective
Enrolment
50 participants (estimated)
Target duration
2 Years
IDs, dates and publications
ClinicalTrials.gov ID
NCT04506957
Sponsor's protocol ID
Pulse-CO Oximetry Hemoglobin
Acronym
SpHb
Status last verified
Sep 2020
First submitted
7 Aug 2020
Last updated
4 Sep 2020
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No: it is not planned to make individual participant data available to other researchers

Publications

  • Baulig W, Seifert B, Spahn DR, Theusinger OM. Accuracy of non-invasive continuous total hemoglobin measurement by Pulse CO-Oximetry in severe traumatized and surgical bleeding patients. J Clin Monit Comput. 2017 Feb;31(1):177-185. doi: 10.1007/s10877-015-9816-2. Epub 2015 Dec 19.

    PubMed 26686689

Questions about this trial

What is this clinical trial studying?

An observational study of Transcutaneous Continuous Hemoglobin Measurement, run by Klinik Hirslanden, Zurich.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 4 Sep 2020. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Werner Baulig, MD (+41442092875, werner.baulig@hirslanden.ch), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Reliability of SpHb to detect CoOxHb and its changes (time frame: 24 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04506957, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 4 Sep 2020.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in