Atrioventricular BlockNCT04544345
Impact of Atrio-ventricular Optimization With His Bundle Pacing on Treatment of Atrio-ventricular Dromotropathy
A study testing His bundle pacing, AV optimized and Backup VVI pacing in people with Atrioventricular Block and Atrioventricular Dyssynchrony, run by University Medical Centre Ljubljana at 1 site in Slovenia.
Trial summary
This study aims to determine the clinical and hemodynamic benefit of atrio-ventricular (AV) resynchronization with His bundle pacing in patients with symptomatic first degree AV block. Read more about this study
- Who is it for?
- Ages 18 to 80 years
- Conditions the study is for
- Atrioventricular Block, Atrioventricular Dyssynchrony
- What is being tested?
- His bundle pacing, AV optimized and Backup VVI pacing
- Type of treatment
- Medical device
- Could I receive a placebo?
- Yes, some participants may receive a placebo
- How many people
- 17 participants
- Where
- 1 siteSlovenia
- Study dates
- 23 Dec 2019to 4 Jan 2023
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 80 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- First OR second degree Mobitz type 1 atrioventricular block with a PR interval > 250 ms
- left ventricular ejection fraction > 50%
- echocardiographic criteria of atrioventricular dyssynchrony (diastolic filling time/RR interval ratio < 0,4 OR fusion of E and A waves OR diastolic mitral regurgitation)
- symptoms on exertion (dyspnea, palpitations)
- insufficient shortening of PR interval during exercise (PR interval > 200 ms at heart rate of 100 beats per minute)
Who cannot join
- left ventricular ejection fraction < 50%
- third degree atrioventricular block
- atrial fibrillation
- sinus node disease
- left bundle branch block
- right bundle branch block
Show all 12Show fewer
- ventricular arrhythmia that indicates implantation of cardioverter defibrillator
- consumption of drugs that influence atrioventricular conduction
- active bacterial infection
- inability to undergo cardiopulmonary exercise test
- anaemia (haemoglobin concentration < 100 g/L)
- pregnancy
Trial locations and contacts
1 site in 1 country.
About this study
This study aims to determine the clinical and hemodynamic benefit of atrio-ventricular (AV) resynchronization with His bundle pacing in patients with symptomatic first degree AV block.
Read the detailed description
The term AV dyssynchrony was introduced by Salden F. and coauthors in 2018. It stands for the adverse effects of AV dyssynchrony due to PR interval prolongation. According to the ESC and ACC guidelines, severe first degree AV block is an IIa indication for permanent pacemaker implantation, yet data on these patients' clinical outcomes are scarce. To independently determine the impact of AV resynchronization, His bundle pacing will be used to avoid intraventricular desynchronization.
Symptomatic patients with severe first-degree AV block and echocardiographically proven AV dyssynchrony will be included in the study.
All patients will receive a dual-chamber pacemaker with an atrial lead positioned in the right atrium and ventricular lead placed on the bundle of His. In a single-blind cross-over design, patients will be randomized to AV sequential His bundle pacing with echo-guided AV optimization or back-up VVI pacing mode. Each study period will last for three months. At the end of both periods, cardiopulmonary exercise testing, complete echocardiographic study, and clinical evaluation will be performed.
Peak oxygen uptake and echocardiography-based hemodynamic parameters in both periods will be compared.
- Being tested
- His bundle pacing, AV optimized, Backup VVI pacing
- Keywords
- AV block, His bundle pacing, AV dyssynchrony, AV optimization, AV dromotropathy, First degree AV block, Peak oxygen uptake
- Medical subject headings
- Atrioventricular Block
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
His bundle pacing, AV optimizedDevice
A Select Secure 3830 (Medtronic, MN, USA) pacing lead will be placed on the bundle of His. In case of unsuccessful His capture, left bundle branch area pacing is going to be targeted. Pacemaker will be programmed to a low base rate and a high tracking rate to allow for intrinsic sinus rhythm. AV delay will be optimized with echocardiography to the shortest AV delay without truncation of the A wave on transmitral pulse wave doppler.
Backup VVI pacingDevice
Pacemaker will be programmed to VVI (ventricular only) mode with low base rate as to allow for intrinsic sinus rhythm without AV optimization.
| Study group | Role | What they receive |
|---|---|---|
| His bundle pacing, AV optimized | Experimental | Pacemaker programmed to DDD mode with ventricular lead placed on the bundle of His and echocardiographically optimized AV delay. Receives: Device: His bundle pacing, AV optimized |
| Backup VVI pacing | Sham comparator | Pacemaker programmed to ventricular only pacing with low base rate (40/min) to allow intrinsic rhythm. Receives: Device: Backup VVI pacing |
What is being measured
The primary outcome is the main question the study is designed to answer.
Changes in exercise capacity
Measured by peak oxygen consumption on cardiopulmonary exercise test
Measured: Baseline, 3 months, 6 months
Changes in left ventricular stroke volume
Measured by echocardiography
Measured: Baseline, 3 months, 6 months
Changes in quality of life using the 5 level EQ-5D questionnaire
EQ-5D is a standardized measure of health status consisting of 2 pages - the EQ-5D descriptive system (descriptive system with five levels) and the EQ visual analog scale ranging from 0 (worst state) to 100 (best state).
Measured: Baseline, 3 months, 6 months
Secondary outcomes (9)
Changes in left ventricular volume
End diastolic volume measured echocardiographicaly with biplane Simpson method
Measured: Baseline, 3 months, 6 months
Changes in left atrial volume
Left atrial volume indexed by body surface area measured by echocardiography
Measured: Baseline, 3 months, 6 months
Changes in the measure of left ventricular mechanical dyssynchrony
Measured by mid-ventricular radial speckle-tracking strain with an anteroseptal to posterior wall delay (AS-P delay)
Measured: Baseline, 3 months, 6 months
Changes in QRS complex width
Measured by electrocardiogram
Measured: Baseline, 3 months, 6 months
Changes in pacing thresholds
Measured during device check
Measured: Baseline, 3 months, 6 months
Changes in sensing of R wave
Measured during device check
Measured: Baseline, 3 months, 6 months
Changes in lead impedance
Measured during device check
Measured: Baseline, 3 months, 6 months
Fluoroscopy time
Time of fluoroscopy use during device implantation
Measured: Baseline
Adverse events
Any of the following adverse events: pocket hematoma, pneumothorax, hemothorax, cardiac tamponade, lead dislocation, lead perforation, cardiac implantable device infection
Measured: through study completion, an average of one year
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted10 Sep 2020
- Study start23 Dec 2019
- Primary completion13 Sep 2022
- Study completion4 Jan 2023
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (12)Papers the sponsor has linked to this study.
- Other trials for Atrioventricular BlockStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- Single blind
- Who is masked
- Participant
- Enrolment
- 17 participants (actual)
Sponsor and investigators
- Lead sponsor
- University Medical Centre Ljubljana
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Anja Zupan Mežnar, University Medical Centre Ljubljana
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04544345
- Sponsor's protocol ID
- UMCLj-AVdromHis
- Status last verified
- Feb 2023
- First submitted
- 26 Aug 2020
- Last updated
- 16 Feb 2023
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- Yes
Publications
Salden FCWM, Kutyifa V, Stockburger M, Prinzen FW, Vernooy K. Atrioventricular dromotropathy: evidence for a distinctive entity in heart failure with prolonged PR interval? Europace. 2018 Jul 1;20(7):1067-1077. doi: 10.1093/europace/eux207.
PubMed 29186415Aro AL, Anttonen O, Kerola T, Junttila MJ, Tikkanen JT, Rissanen HA, Reunanen A, Huikuri HV. Prognostic significance of prolonged PR interval in the general population. Eur Heart J. 2014 Jan;35(2):123-9. doi: 10.1093/eurheartj/eht176. Epub 2013 May 14.
PubMed 23677846Iliev II, Yamachika S, Muta K, Hayano M, Ishimatsu T, Nakao K, Komiya N, Hirata T, Ueyama C, Yano K. Preserving normal ventricular activation versus atrioventricular delay optimization during pacing: the role of intrinsic atrioventricular conduction and pacing rate. Pacing Clin Electrophysiol. 2000 Jan;23(1):74-83. doi: 10.1111/j.1540-8159.2000.tb00652.x.
PubMed 10666756European Society of Cardiology (ESC); European Heart Rhythm Association (EHRA); Brignole M, Auricchio A, Baron-Esquivias G, Bordachar P, Boriani G, Breithardt OA, Cleland J, Deharo JC, Delgado V, Elliott PM, Gorenek B, Israel CW, Leclercq C, Linde C, Mont L, Padeletti L, Sutton R, Vardas PE. 2013 ESC guidelines on cardiac pacing and cardiac resynchronization therapy: the task force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). Europace. 2013 Aug;15(8):1070-118. doi: 10.1093/europace/eut206. Epub 2013 Jun 24. No abstract available.
PubMed 23801827Wilkoff BL, Cook JR, Epstein AE, Greene HL, Hallstrom AP, Hsia H, Kutalek SP, Sharma A; Dual Chamber and VVI Implantable Defibrillator Trial Investigators. Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial. JAMA. 2002 Dec 25;288(24):3115-23. doi: 10.1001/jama.288.24.3115.
PubMed 12495391Kiehl EL, Makki T, Kumar R, Gumber D, Kwon DH, Rickard JW, Kanj M, Wazni OM, Saliba WI, Varma N, Wilkoff BL, Cantillon DJ. Incidence and predictors of right ventricular pacing-induced cardiomyopathy in patients with complete atrioventricular block and preserved left ventricular systolic function. Heart Rhythm. 2016 Dec;13(12):2272-2278. doi: 10.1016/j.hrthm.2016.09.027.
PubMed 27855853Sharma PS, Dandamudi G, Naperkowski A, Oren JW, Storm RH, Ellenbogen KA, Vijayaraman P. Permanent His-bundle pacing is feasible, safe, and superior to right ventricular pacing in routine clinical practice. Heart Rhythm. 2015 Feb;12(2):305-12. doi: 10.1016/j.hrthm.2014.10.021. Epub 2014 Oct 22.
PubMed 25446158Abdelrahman M, Subzposh FA, Beer D, Durr B, Naperkowski A, Sun H, Oren JW, Dandamudi G, Vijayaraman P. Clinical Outcomes of His Bundle Pacing Compared to Right Ventricular Pacing. J Am Coll Cardiol. 2018 May 22;71(20):2319-2330. doi: 10.1016/j.jacc.2018.02.048. Epub 2018 Mar 10.
PubMed 29535066Moss AJ, Hall WJ, Cannom DS, Klein H, Brown MW, Daubert JP, Estes NA 3rd, Foster E, Greenberg H, Higgins SL, Pfeffer MA, Solomon SD, Wilber D, Zareba W; MADIT-CRT Trial Investigators. Cardiac-resynchronization therapy for the prevention of heart-failure events. N Engl J Med. 2009 Oct 1;361(14):1329-38. doi: 10.1056/NEJMoa0906431. Epub 2009 Sep 1.
PubMed 19723701Kutyifa V, Stockburger M, Daubert JP, Holmqvist F, Olshansky B, Schuger C, Klein H, Goldenberg I, Brenyo A, McNitt S, Merkely B, Zareba W, Moss AJ. PR interval identifies clinical response in patients with non-left bundle branch block: a Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy substudy. Circ Arrhythm Electrophysiol. 2014 Aug;7(4):645-51. doi: 10.1161/CIRCEP.113.001299. Epub 2014 Jun 24.
PubMed 24963007Joshi NP, Stopper MM, Li J, Beshai JF, Pavri BB. Impact of baseline PR interval on cardiac resynchronization therapy outcomes in patients with narrow QRS complexes: an analysis of the ReThinQ Trial. J Interv Card Electrophysiol. 2015 Aug;43(2):145-9. doi: 10.1007/s10840-015-9999-y. Epub 2015 Apr 29.
PubMed 25921348Zhang J, Guo J, Hou X, Wang Y, Qian Z, Li K, Ge P, Zou J. Comparison of the effects of selective and non-selective His bundle pacing on cardiac electrical and mechanical synchrony. Europace. 2018 Jun 1;20(6):1010-1017. doi: 10.1093/europace/eux120.
PubMed 28575215
Study at a glance
From the registry record, last updated by the sponsor on 16 Feb 2023. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Impact of Atrio-ventricular Optimization With His Bundle Pacing on Treatment of Atrio-ventricular Dromotropathy
- ClinicalTrials.gov ID
- NCT04544345
- Acronym / sponsor ID
- UMCLj-AVdromHis
- Keywords
- AV block, His bundle pacing, AV dyssynchrony, AV optimization, AV dromotropathy, First degree AV block, Peak oxygen uptake
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 17 participants (actual)
- Lead sponsor
- University Medical Centre LjubljanaUniversity, hospital or other
- Study start
- 23 Dec 2019 (actual)
- Primary completion
- 13 Sep 2022 (actual)
- Study completion
- 4 Jan 2023 (actual)
- First posted
- 10 Sep 2020 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This study aims to determine the clinical and hemodynamic benefit of atrio-ventricular (AV) resynchronization with His bundle pacing in patients with symptomatic first degree AV block.
Detailed description
The term AV dyssynchrony was introduced by Salden F. and coauthors in 2018. It stands for the adverse effects of AV dyssynchrony due to PR interval prolongation. According to the ESC and ACC guidelines, severe first degree AV block is an IIa indication for permanent pacemaker implantation, yet data on these patients' clinical outcomes are scarce. To independently determine the impact of AV resynchronization, His bundle pacing will be used to avoid intraventricular desynchronization.
Symptomatic patients with severe first-degree AV block and echocardiographically proven AV dyssynchrony will be included in the study.
All patients will receive a dual-chamber pacemaker with an atrial lead positioned in the right atrium and ventricular lead placed on the bundle of His. In a single-blind cross-over design, patients will be randomized to AV sequential His bundle pacing with echo-guided AV optimization or back-up VVI pacing mode. Each study period will last for three months. At the end of both periods, cardiopulmonary exercise testing, complete echocardiographic study, and clinical evaluation will be performed.
Peak oxygen uptake and echocardiography-based hemodynamic parameters in both periods will be compared.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- Single blind (participant)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| His bundle pacing, AV optimized | Experimental | Device: His bundle pacing, AV optimizedPacemaker programmed to DDD mode with ventricular lead placed on the bundle of His and echocardiographically optimized AV delay. |
| Backup VVI pacing | Sham comparator | Device: Backup VVI pacingPacemaker programmed to ventricular only pacing with low base rate (40/min) to allow intrinsic rhythm. |
Who may qualify
- Ages
- 18 to 80 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (5 listed)
- First OR second degree Mobitz type 1 atrioventricular block with a PR interval > 250 ms
- left ventricular ejection fraction > 50%
- echocardiographic criteria of atrioventricular dyssynchrony (diastolic filling time/RR interval ratio < 0,4 OR fusion of E and A waves OR diastolic mitral regurgitation)
- symptoms on exertion (dyspnea, palpitations)
- insufficient shortening of PR interval during exercise (PR interval > 200 ms at heart rate of 100 beats per minute)
Key exclusion criteria (12 listed)
- left ventricular ejection fraction < 50%
- third degree atrioventricular block
- atrial fibrillation
- sinus node disease
- left bundle branch block
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| His bundle pacing, AV optimizedA Select Secure 3830 (Medtronic, MN, USA) pacing lead will be placed on the bundle of His. In case of unsuccessful His capture, left bundle branch area pacing is going to be targeted. Pacemaker will be programmed to a low base rate and a high tracking rate to allow for intrinsic sinus rhythm. AV delay will be optimized with echocardiography to the shortest AV delay without truncation of the A wave on transmitral pulse wave doppler. | Device | His bundle pacing, AV optimized |
| Backup VVI pacingPacemaker will be programmed to VVI (ventricular only) mode with low base rate as to allow for intrinsic sinus rhythm without AV optimization. | Device | Backup VVI pacing |
Primary outcome
Changes in exercise capacity
Time frame: Baseline, 3 months, 6 months
Measured by peak oxygen consumption on cardiopulmonary exercise test
Changes in left ventricular stroke volume
Time frame: Baseline, 3 months, 6 months
Measured by echocardiography
Changes in quality of life using the 5 level EQ-5D questionnaire
Time frame: Baseline, 3 months, 6 months
EQ-5D is a standardized measure of health status consisting of 2 pages - the EQ-5D descriptive system (descriptive system with five levels) and the EQ visual analog scale ranging from 0 (worst state) to 100 (best state).
9 secondary outcomes
Changes in left ventricular volume
Time frame: Baseline, 3 months, 6 months
Changes in left atrial volume
Time frame: Baseline, 3 months, 6 months
Changes in the measure of left ventricular mechanical dyssynchrony
Time frame: Baseline, 3 months, 6 months
Changes in QRS complex width
Time frame: Baseline, 3 months, 6 months
Changes in pacing thresholds
Time frame: Baseline, 3 months, 6 months
Changes in sensing of R wave
Time frame: Baseline, 3 months, 6 months
Changes in lead impedance
Time frame: Baseline, 3 months, 6 months
Fluoroscopy time
Time frame: Baseline
Adverse events
Time frame: through study completion, an average of one year
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 16 Feb 2023.
- Background: PubMed 29186415Salden FCWM, Kutyifa V, Stockburger M, Prinzen FW, Vernooy K. Atrioventricular dromotropathy: evidence for a distinctive entity in heart failure with prolonged PR interval? Europace. 2018 Jul 1;20(7):1067-1077. doi: 10.1093/europace/eux207.
- Background: PubMed 23677846Aro AL, Anttonen O, Kerola T, Junttila MJ, Tikkanen JT, Rissanen HA, Reunanen A, Huikuri HV. Prognostic significance of prolonged PR interval in the general population. Eur Heart J. 2014 Jan;35(2):123-9. doi: 10.1093/eurheartj/eht176. Epub 2013 May 14.
- Background: PubMed 10666756Iliev II, Yamachika S, Muta K, Hayano M, Ishimatsu T, Nakao K, Komiya N, Hirata T, Ueyama C, Yano K. Preserving normal ventricular activation versus atrioventricular delay optimization during pacing: the role of intrinsic atrioventricular conduction and pacing rate. Pacing Clin Electrophysiol. 2000 Jan;23(1):74-83. doi: 10.1111/j.1540-8159.2000.tb00652.x.
- Background: PubMed 23801827European Society of Cardiology (ESC); European Heart Rhythm Association (EHRA); Brignole M, Auricchio A, Baron-Esquivias G, Bordachar P, Boriani G, Breithardt OA, Cleland J, Deharo JC, Delgado V, Elliott PM, Gorenek B, Israel CW, Leclercq C, Linde C, Mont L, Padeletti L, Sutton R, Vardas PE. 2013 ESC guidelines on cardiac pacing and cardiac resynchronization therapy: the task force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). Europace. 2013 Aug;15(8):1070-118. doi: 10.1093/europace/eut206. Epub 2013 Jun 24. No abstract available.
- Background: PubMed 12495391Wilkoff BL, Cook JR, Epstein AE, Greene HL, Hallstrom AP, Hsia H, Kutalek SP, Sharma A; Dual Chamber and VVI Implantable Defibrillator Trial Investigators. Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial. JAMA. 2002 Dec 25;288(24):3115-23. doi: 10.1001/jama.288.24.3115.
- Background: PubMed 27855853Kiehl EL, Makki T, Kumar R, Gumber D, Kwon DH, Rickard JW, Kanj M, Wazni OM, Saliba WI, Varma N, Wilkoff BL, Cantillon DJ. Incidence and predictors of right ventricular pacing-induced cardiomyopathy in patients with complete atrioventricular block and preserved left ventricular systolic function. Heart Rhythm. 2016 Dec;13(12):2272-2278. doi: 10.1016/j.hrthm.2016.09.027.
- Background: PubMed 25446158Sharma PS, Dandamudi G, Naperkowski A, Oren JW, Storm RH, Ellenbogen KA, Vijayaraman P. Permanent His-bundle pacing is feasible, safe, and superior to right ventricular pacing in routine clinical practice. Heart Rhythm. 2015 Feb;12(2):305-12. doi: 10.1016/j.hrthm.2014.10.021. Epub 2014 Oct 22.
- Background: PubMed 29535066Abdelrahman M, Subzposh FA, Beer D, Durr B, Naperkowski A, Sun H, Oren JW, Dandamudi G, Vijayaraman P. Clinical Outcomes of His Bundle Pacing Compared to Right Ventricular Pacing. J Am Coll Cardiol. 2018 May 22;71(20):2319-2330. doi: 10.1016/j.jacc.2018.02.048. Epub 2018 Mar 10.
- Background: PubMed 19723701Moss AJ, Hall WJ, Cannom DS, Klein H, Brown MW, Daubert JP, Estes NA 3rd, Foster E, Greenberg H, Higgins SL, Pfeffer MA, Solomon SD, Wilber D, Zareba W; MADIT-CRT Trial Investigators. Cardiac-resynchronization therapy for the prevention of heart-failure events. N Engl J Med. 2009 Oct 1;361(14):1329-38. doi: 10.1056/NEJMoa0906431. Epub 2009 Sep 1.
- Background: PubMed 24963007Kutyifa V, Stockburger M, Daubert JP, Holmqvist F, Olshansky B, Schuger C, Klein H, Goldenberg I, Brenyo A, McNitt S, Merkely B, Zareba W, Moss AJ. PR interval identifies clinical response in patients with non-left bundle branch block: a Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy substudy. Circ Arrhythm Electrophysiol. 2014 Aug;7(4):645-51. doi: 10.1161/CIRCEP.113.001299. Epub 2014 Jun 24.
- Background: PubMed 25921348Joshi NP, Stopper MM, Li J, Beshai JF, Pavri BB. Impact of baseline PR interval on cardiac resynchronization therapy outcomes in patients with narrow QRS complexes: an analysis of the ReThinQ Trial. J Interv Card Electrophysiol. 2015 Aug;43(2):145-9. doi: 10.1007/s10840-015-9999-y. Epub 2015 Apr 29.
- Background: PubMed 28575215Zhang J, Guo J, Hou X, Wang Y, Qian Z, Li K, Ge P, Zou J. Comparison of the effects of selective and non-selective His bundle pacing on cardiac electrical and mechanical synchrony. Europace. 2018 Jun 1;20(6):1010-1017. doi: 10.1093/europace/eux120.
- Individual participant dataSharing planned: Yes
Related trials for Atrioventricular Block
Active, not recruitingObservational study
Safety, Performance, and Clinical Benefit of Pacing the Left Bundle Branch Area - Post-Market Clinical Follow-up
Bradycardia, Atrioventricular Block
Recruiting
SPIKE FLOW Endocardial Lead Safety and Performance Study
Acute Myocardial Infarction (AMI), Asystole
Active, not recruitingObservational study
AVEIR DR Coverage With Evidence Development (CED) Study
Cardiac Pacemaker, Arrythmia
Recruiting
Novel Approach to Conduction System Pacing With Use of Ultrasound
Conduction Block, Atrioventricular, Bundle-Branch Block
Not yet recruiting
Head-to-Head (H2H) Comparison of Ambulatory Cardiac ECG Monitors in Japan
Atrial Fibrillation (AF), Atrial Flutter
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing His bundle pacing, AV optimized and Backup VVI pacing in people with Atrioventricular Block and Atrioventricular Dyssynchrony, run by University Medical Centre Ljubljana at 1 site in Slovenia.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 12 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 16 Feb 2023. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Slovenia. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. Some participants in this study may receive a placebo. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Changes in exercise capacity (time frame: Baseline, 3 months, 6 months). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT04544345, which also lists 12 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 16 Feb 2023; AzTrials last refreshed its copy on 31 Oct 2026.