AzTrials
AzTrials

Surgery--ComplicationsNCT04569240

Accuracy of the Dexcom G6 Continuous Glucose Monitoring System Following Cardiac Surgery

A study testing Dexcom G6 continuous glucose monitor in people with Surgery--Complications, run by The Cleveland Clinic at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This is a prospective longitudinal study to study the agreement between a novel continuous glucose monitoring system (CGMS) versus current blood glucose monitoring. Subjects in this study will have their blood glucose measured regularly every 1-3 hours with current methods in the cardiovascular intensive care unit… Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Surgery--Complications
What is being tested?
Dexcom G6 continuous glucose monitor
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
40 participants
Where
1 siteUnited States
Study dates
1 May 2021to 1 Jul 2024
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age 18 years and above
  • Planned cardiovascular surgery
  • Planned admission to Cleveland Clinic Main Campus J5 or J6 or Q5 cardiovascular ICU (CVICU) post-operatively
  • With or without known diabetes; if with known diagnosis of diabetes, diabetes can be type 1, type 2, or secondary

Who cannot join

  • Allergy to the material of the CGMS or the adhesive to be used
  • Skin conditions precluding the use of the CGMS
  • Pregnancy
  • Other conditions that investigators deem inappropriate for the study

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Cleveland Clinic

    Cleveland, Ohio, 44195

Other trials in United States

About this study

This is a prospective longitudinal study to study the agreement between a novel continuous glucose monitoring system (CGMS) versus current blood glucose monitoring.

Subjects in this study will have their blood glucose measured regularly every 1-3 hours with current methods in the cardiovascular intensive care unit (CVICU), and by point of care glucose using the Accuchek Inform II on the regular floors, and the CGMS at the same time will be captured. Subjects will have measurements taken throughout their stay in the CVICU and on the regular floors.

Read the detailed description

Maintaining tight blood glucose control following surgery is imperative to reducing infections and neurologic dysfunction. This requires frequent blood sampling while in the intensive care unit, leading to increased waste of blood and utilizing time and resources to collect samples and wait for results. Additionally, when on the regular floors, frequent point of care fingersticks for glucose levels are needed for therapeutic intervention.

Continuous glucose monitoring systems (CGMS) are now available for ambulatory use in patients with diabetes. The potential of using such a system in the hospital, including during the postoperative critical care setting and upon transfer to the regular floor, may reduce personnel burden, produce rapid results, and decrease blood waste. However, these systems have not yet been validated for hospital use.

This is a prospective longitudinal study to study the agreement between a novel continuous glucose monitoring system (CGMS) versus current blood glucose monitoring.

Subjects in this study will have their blood glucose measured regularly every 1-3 hours with current methods in the CVICU, and by point of care glucose using the Accuchek Inform II on the regular floors, and the CGMS at the same time will be captured. Subjects will have measurements taken throughout their stay in the CVICU and on the regular floors. Agreement and correlation between systems will be calculated, and error will be classified using the Surveillance Error grid. The proportion of errors of at least moderate risk will be calculated.

Subject characteristics including demographics, comorbidities and baseline disease severity will be summarized using means and standard deviations for continuous measures and frequencies and percentages for categorical factors. To evaluate agreement between methods, concordance correlation coefficients will be calculated, using the method that adjusts for repeated measures as described by King and implemented in software by Carrasco. Analysis will be performed overall, and then stratifying by type of current measure, if the type of measurement varies across settings. Correlations will be calculated using the methods described by Bland and Altman and implemented by Bakdash and Marusich. Differences will also be evaluated for errors according to the Surveillance Error Grid. Rates of moderate or more severe errors will be calculated. For each measure above, 95% confidence intervals will be calculated, accounting for the clustering within subject.. Analyses will be performed using SAS software (version 9.4; Cary, NC) and R software (version 3.5; Vienna Austria).

Glucose readings obtained from the CGMS will be compared with

  1. blood glucose from the arterial blood gas (ABG) or peripheral/central venous catheter if arterial catheter not in use (standard of care in CVICU) while patients are in the CVICU
  2. fingerstick point of care (POC) glucose when patients are on the regular floors
Being tested
Dexcom G6 continuous glucose monitor

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Dexcom G6 continuous glucose monitorDevice

    Dexcom G6 continuous glucose monitor will be applied to the upper outer arm before cardiovascular surgery. Data will be collected for 10 days or upon discharge from the ICU.

Study groups in NCT04569240
Study groupRoleWhat they receive
Dexcom G6 continuous glucose monitorOtherAll patients will have a Dexcom G6 continuous glucose monitor placed pre-operatively. The glucose readings will be collected for 10 days or upon discharge from the ICU and data will be compared with arterial blood glucose readings or venous Accu-Check Inform II glucose readings
Receives: Device: Dexcom G6 continuous glucose monitor

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of Matching Glucose Measurements (CGM Versus Blood Glucose Measurements)

    Glucose readings from the Dexcom continuous glucose monitor compared with blood glucose from the arterial blood gas (ABG) or peripheral/central venous catheter

    Measured: Up to 10 days

  2. Glucose Readings From Continuous Glucose Monitor (CGM) Versus Point of Care Glucose

    Glucose readings in mg/dL from the Dexcom continuous glucose monitor (CGM) will be compared with fingerstick point of care glucose levels in mg/dL

    Measured: up to 10 days

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted29 Sep 2020
  2. Study start1 May 2021
  3. Primary completion20 Jan 2024
  4. Study completion1 Jul 2024

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Supportive care
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
40 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04569240
Sponsor's protocol ID
20-698
Status last verified
Oct 2025
First submitted
8 Sep 2020
Last updated
10 Nov 2025
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Publications

  • King TS, Chinchilli VM, Carrasco JL. A repeated measures concordance correlation coefficient. Stat Med. 2007 Jul 20;26(16):3095-113. doi: 10.1002/sim.2778.

    PubMed 17216594
  • Carrasco JL, Phillips BR, Puig-Martinez J, King TS, Chinchilli VM. Estimation of the concordance correlation coefficient for repeated measures using SAS and R. Comput Methods Programs Biomed. 2013 Mar;109(3):293-304. doi: 10.1016/j.cmpb.2012.09.002. Epub 2012 Sep 29.

    PubMed 23031487
  • Bland JM, Altman DG. Calculating correlation coefficients with repeated observations: Part 1--Correlation within subjects. BMJ. 1995 Feb 18;310(6977):446. doi: 10.1136/bmj.310.6977.446. No abstract available.

    PubMed 7873953
  • Bakdash JZ, Marusich LR. Repeated Measures Correlation. Front Psychol. 2017 Apr 7;8:456. doi: 10.3389/fpsyg.2017.00456. eCollection 2017.

    PubMed 28439244
  • Klonoff DC, Lias C, Vigersky R, Clarke W, Parkes JL, Sacks DB, Kirkman MS, Kovatchev B; Error Grid Panel. The surveillance error grid. J Diabetes Sci Technol. 2014 Jul;8(4):658-72. doi: 10.1177/1932296814539589. Epub 2014 Jun 13.

    PubMed 25562886

Questions about this trial

What is this clinical trial studying?

A study testing Dexcom G6 continuous glucose monitor in people with Surgery--Complications, run by The Cleveland Clinic at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 10 Nov 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 19 Sep 2024). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Number of Matching Glucose Measurements (CGM Versus Blood Glucose Measurements) (time frame: Up to 10 days). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04569240, which also lists 5 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 10 Nov 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in