This study is to evaluate the feasibility of myocardial Standardized Uptake Volume (SUV) assessment by means of X- (Single photon emission tomography) SPECT/Computed tomography (CT), to assess normal reference value under rest and stress in a homogeneous population without Coronary Artery Disease (CAD) and to assess… Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Coronary Artery Disease
What is being tested?
99mTc-sestamibi myocardial perfusion SPECT and 82Rb-Chloride myocardial perfusion PET with CCTA
Could I receive a placebo?
No, everyone receives an active treatment
How many people
52 participants
Where
1 siteSwitzerland
Study dates
7 Dec 2021to 28 May 2024
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Referral to non-invasive nuclear ischemia test as part of clinical care
  • Suspected coronary artery disease based on clinical symptoms
  • Informed Consent as documented by signature

Who cannot join

  • Pregnancy
  • Allergy against adenosine
  • Allergy against iodinated contrast medium
  • Recent myocardial infarction (<1 month)
  • Previous history of coronary revascularization
  • Severe asthma
Show all 17Show fewer
  • Thyroid hyperfunction
  • atrioventricular block (AV) Block > I grade
  • Arrhythmic cardiopathy
  • Weight >101 Kg.
  • Acute or chronic renal impairment defined as Serum-Creatinine: above 1.5x upper limit of normal (ULN) and/or glomerular filtration rate (GFR) < 30 ml/min
  • Inability to follow the procedures of the study, e.g. due to language problems, psychological disorders, dementia, etc. of the participant,
  • Participation in another study with investigational drug within the 30 days preceding and during the present study,
  • Enrolment of the investigator, his/her family members, employees and other dependent persons,
  • Claustrophobia
  • Intake of caffeine <24 Hours before the first day of examination
  • Enrolment into another study using ionizing radiation within the previous 12 months.

Trial locations and contacts

1 site in 1 country.

Switzerland1 site
  • Clinic of Radiology & Nuclear Medicine, University Hospital of Basel

    Basel, 4031

Other trials in Switzerland

About this study

Official title: xSPECT-based Myocardial Perfusion Scintigraphy: Consistency of Functional Values and Feasibility of Myocardial Uptake Quantitation in Patients With Suspected Coronary Artery Disease (xSPECT MPI Study)

This study is to evaluate the feasibility of myocardial Standardized Uptake Volume (SUV) assessment by means of X- (Single photon emission tomography) SPECT/Computed tomography (CT), to assess normal reference value under rest and stress in a homogeneous population without Coronary Artery Disease (CAD) and to assess the variation of absolute quantitative SUV measurements under rest and stress. The values will be evaluated in comparison with perfusion Positron Emission Tomography (PET)/CT (using 82Rb as perfusion tracer) and CT coronary angiography (CTCA) with contrast medium.).

Being tested
99mTc-sestamibi myocardial perfusion SPECT, 82Rb-Chloride myocardial perfusion PET with CCTA
Keywords
82Rb-Chloride myocardial perfusion PET with CTCA, 99mTc-sestamibi myocardial perfusion SPECT, Myocardial perfusion SPECT, Absolute myocardial blood flow (MBF), Myocardial Standardized uptake value (SUV), CT coronary angiography (CTCA)
Medical subject headings
Coronary Artery Disease

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • 99mTc-sestamibi myocardial perfusion SPECTDiagnostic test

    82Rb-PET/CT with CT based coronary angiography (CCTA) as part of clinical care at Day 1

  • 82Rb-Chloride myocardial perfusion PET with CCTADiagnostic test

    stress-rest 99mTc-sestamibi myocardial perfusion SPECT, performed subsequent to 99mTc-sestamibi myocardial perfusion SPECT at Day 2

Study groups in NCT04583787
Study groupRoleWhat they receive
Patients with suspected CADExperimentalNot described
Receives: Diagnostic Test: 99mTc-sestamibi myocardial perfusion SPECT; Diagnostic Test: 82Rb-Chloride myocardial perfusion PET with CCTA

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Absolute flow quantification (assessed by PET/CT)

    Consistency of quantitative parameters assessed by xSPECT compared to the "gold standard" which includes absolute flow quantification (assessed by PET/CT). The feasibility of myocardial SUV assessment by means of X-SPECT/CT will be tested by correlating the automatically calculated values with automatically calculated, PET-derived absolute blood flows. Rationale: values of quantified myocardial uptake are expected to be reliable the more they correlate with absolutely quantified myocardial blood flow in the myocardium, given the expected proportionality between uptake and subtending coronary blood flow.

    Measured: 60 minutes at Day 1

  2. presence of significant coronary stenoses (CTCA)

    Consistency of quantitative parameters assessed by xSPECT compared to the "gold standard" which includes the presence of significant coronary stenoses (CTCA). Normal reference values under rest and stress in a homogeneous population without CAD will be evaluated in comparison with perfusion 82Rb-PET/CT and CT coronary angiography (CTCA) with contrast medium. Rationale: a coronary artery disease can be ruled out in patients with normal 82Rb-PET and without detectable stenoses on CTCA, thus identifying a subpopulation of normal patients, wherein reference normal values can be provided.

    Measured: 120 minutes at Day 2

Secondary outcomes (5)
  1. Determination of uptake patterns that are suggestive for CAD

    Values of quantified myocardial uptake (SUV) will be identified and correlated to pathological perfusion patterns as determined by 82Rb-PET/CT.

    Rationale: it is expected that patients with pathological PET imaging and reduced flow rates also present with reduced myocardial uptake of 99mTc-sestamibi.

    Measured: one point assessment after interventions at day 2

  2. Quantitative 99mTC-sestamibi uptake values of the whole myocardium

    Quantitative 99mTC-sestamibi uptake values of the whole myocardium, analysis of the diagnostic accuracy. Values will be correlated to image-driven diagnosis of CAD Rationale: it is foreseen that a diagnosis can be provided by finding reduced myocardial uptake of 99mTc-sestamibi

    Measured: one point assessment after interventions at day 2

  3. Comparison of PET/CT, standard Myocardial perfusion SPECT (MPS) and new quantitative 99mTc-sestamibi xSPECT/quantitative computerized tomography (QCT) in the same patient

    Comparison of sensitivity, specificity and accuracy of PET/CT, standard MPS and new quantitative 99mTc-sestamibi xSPECT/QCT in the same patient. Using the final clinical diagnosis of CAD, the diagnostic accuracy of each methodology will be tested by means of receiver operating characteristic (ROC) curves.

    Rationale: it is expected that a quantitative approach can increase the diagnostic accuracy of SPECT by enhancing its sensitivity in case of globally reduced myocardial perfusion, similarly to what gained by quantitative PET

    Measured: one point assessment after interventions at day 2

  4. Interobserver variability of all imaging modalities

    Interobserver variability of all imaging modalities. A kappa- correlation coefficient will be calculated for all three modalities.

    Rationale: the quantitative data should provide higher interobserver consistency in the evaluation of patients with suspected CAD with SPECT, thus allowing for similar variability compared to quantitative PET.

    Measured: one point assessment after interventions at day 2

  5. Interobserver variability of qualitative and quantitative assessments

    Interobserver variability of qualitative and quantitative assessments: a kappa correlation coefficient will be evaluated.

    Rationale: the quantitative data should provide higher interobserver consistency in the evaluation of patients with suspected CAD

    Measured: one point assessment after interventions at day 2

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted12 Oct 2020
  2. Study start7 Dec 2021
  3. Primary completion28 May 2024
  4. Study completion28 May 2024

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Model description
Patients will receive a 82Rb-PET/CT with CT based coronary angiography (CCTA) as part of clinical care. Subsequently, patients will undergo a stress-rest 99mTc-sestamibi myocardial perfusion SPECT, which will be evaluated both qualitatively and quantitatively
Masking
None (open label)
Enrolment
52 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04583787
Sponsor's protocol ID
2020-02090, qu20Caobelli
Acronym
xSPECT MPI
Status last verified
Jun 2024
First submitted
28 Sep 2020
Last updated
28 Jun 2024
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

A study testing 99mTc-sestamibi myocardial perfusion SPECT and 82Rb-Chloride myocardial perfusion PET with CCTA in people with Coronary Artery Disease, run by University Hospital, Basel, Switzerland at 1 site in Switzerland.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 17 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 28 Jun 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Switzerland. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Absolute flow quantification (assessed by PET/CT) (time frame: 60 minutes at Day 1). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 28 Jun 2024.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in