Coronary Artery DiseaseOPTIMISNCT04666584
Optimal Predilatation Treatment Before Implantation of a Magmaris Bioresorbable Scaffold in Coronary Artery Stenosis
A study testing ScoreFlex balloon and Device: standard non-compliant balloon in people with Coronary Artery Disease and Stable Angina, run by Odense University Hospital at 1 site in Denmark.
Trial summary
The aim of the study is to investigate if lesion preparation with a ScoreFlex balloon compared to a standard non-compliant balloon improve vascular healing and minimize lumen reduction after implantation of a Magmaris bioresorbable scaffold. Read more about this study
- Who is it for?
- Ages 18 to 80 years
- Conditions the study is for
- Coronary Artery Disease, Stable Angina, Coronary Artery Stenosis
- What is being tested?
- ScoreFlex balloon and Device: standard non-compliant balloon
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 82 participants
- Where
- 1 siteDenmark
- Study dates
- 14 Dec 2020to 31 Dec 2024
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 80 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Patients with stable angina pectoris and non-ST elevation myocardial infarction referred for invasive coronary angiography and percutaneous coronary intervention at Department of Cardiology, Odense University Hospital (Odense, Denmark)
Who cannot join
- participation in other randomized clinical trials
- life expectancy < 1 year
- allergy to aspirin, clopidogrel, ticagrelor or prasugrel
- eGFR < 30 mL/min
- tortuous and angiographically estimated extremely calcified lesions
- ostial, left main and bifurcation lesions
Show all 9Show fewer
- lesions in a reference vessel diameter < 2.0 mm
- hemodynamic instability
- scheduled for coronary artery bypass grafting
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Optimal Predilatation Treatment Before Implantation of a Magmaris Bioresorbable Scaffold In Coronary Artery Stenosis
The aim of the study is to investigate if lesion preparation with a ScoreFlex balloon compared to a standard non-compliant balloon improve vascular healing and minimize lumen reduction after implantation of a Magmaris bioresorbable scaffold.
Read the detailed description
Introduction: Ischemic heart disease (IHD) is characterized by progressive atherosclerosis in coronary arteries and may cause coronary artery stenosis or acute thrombus and occlusion. IHD is often treated with percutaneous coronary intervention (PCI) with balloon dilatation and implantation of a stent. The drug-eluting stents (DES) have been developed to minimize neointimal growth after implantation and reduce the risk of in-stent restenosis compared to bare-metal stents (BMS). Newer devices, bioresorbable scaffold (BRS), are made from a bioresorbable material slowly dissolving after implantation. The BRS guarantees optimal vessel support after balloon dilatation and implantation, but the artery can obtain original function and flexibility after the BRS has vanished. The development of the Magmaris BRS, with its improved radial strength, thinner struts compared to previous BRSs, is developed to reduce the complications seen in earlier generation BRS such as recoil, fracture and late stent thrombosis.
Previous studies have shown that coronary lesions treated with the previous generation of the Magmaris BRS resulted on lumen area reduction, possibly a consequence by increased plaque burden, compromising the scaffold area, combined with increased neointimal formation in the early phase of vascular healing and fast resolution.
Due to decreased radial strength of the BRS compared to metal stents, modification of plaque prior to BRS-implantation is necessary. The ScoreFlex balloon is a non-compliant balloon with circumference of fixated, scoring elements and permits controlled expansion and fragmentation of calcified plaque, compared to standard treatments with a non-compliant balloon.
Intravascular imaging with Intravascular Ultrasound (IVUS) and Optical Coherence Tomography (OCT) can assess the morphology and location of plaques in the coronary stenosis prior to PCI thereby optimizing the implantation. The scaffold-treated segment can also be evaluated with intravascular imaging components such as stent coverage, malapposition and neointimal hyperplasia, but only if the scaffold is visible. If the scaffold is dissolved, another method to assess the vascular healing is needed. IVUS can evaluate change in elastic external membrane (EEM), change in remodeling and minimal lumen area (MLA). The reduction in MLA is associated with increased neointimal hyperplasia and plaque burden in the vessel wall.
The aim of the study is to investigate if lesion preparation with a ScoreFlex balloon compared to a standard non-compliant balloon improve vascular healing and minimize lumen reduction after implantation of a Magmaris bioresorbable scaffold.
Method: The study is designed as a prospective randomized trial conduced at a single center (Odense University Hospital, Denmark). Eighty-two patients with stable angina pectoris and non-ST-segment elevation myocardial infarctions are included, if they meet the criteria. Pre-dilatation with a 2.0 mm balloon is performed followed by pre-interventional IVUS and OCT. Patients are randomized to lesion preparation and pre-dilatation with either the ScoreFlex balloon or a standard non-compliant balloon with a 1:1 balloon-to-artery ratio by measuring the reference segments. The residual stenosis should be less than 20 %. If the pre-dilatation goal is not achieved, up-scaling to a balloon 0,5 mm larger is allowed. The lesion is treated with implantation of a Magmaris scaffold. Finally, IVUS and OCT-images of the final result are obtained. Follow-up IVUS and OCT images are performed after 6 and 12 months.
Post-PCI OCT-images are analyzed at baseline and 6 and 12 months after index procedure. Change in MLA in the stented segment is measured with IVUS and OCT. The vascular healing is based on finding from the OCT images.
The study is submitted and approved by the Regional Committees on Health Research Ethics for Southern Denmark (Project-ID: S-20200114) and Danish Data Agency (Journal nr.: 20/49900) Statistics: Assuming data are normally distributed, categorical data will be presented as numbers and frequencies and compared using chi2-test. Continuous data will be presented as mean ± SD and compared using Student t-test- SPSS version 26.0 will be used for the statistical analysis.
The estimated sample size is based on data, from the HONEST study by Fallesen et al. The reduction of MLA from 6.99 mm2 to 5.01 mm (27%) 6 months after implantation of a Magmaris BRS, represented the expected reference group. Optimal lesion preparation with pre-dilatation with a ScoreFlex balloon is estimated to minimize MLA reduction from 6.99 mm2 to 6.22 mm2 (11%). A power calculation is conducted using the expected MLA after 6 months (6.22 mm2 for the ScoreFlex balloon and 5.01 mm2 for the standard non-compliant balloon). Inclusion of 35 patients in each group is necessary to reach statistical significance in case of 2-tailed significance level of 0.05 and power of 80 %. Loss to follow-up and poor image quality finalize an expected drop-out rate of 15 %, thereby requiring 82 patients in total.
- Conditions
- Coronary Artery Disease, Stable Angina, Coronary Artery Stenosis, Myocardial Infarction, Cardiovascular Diseases, Myocardial Ischemia
- Being tested
- ScoreFlex balloon, Device: standard non-compliant balloon
- Keywords
- bioresorbable scaffolds, optical coherence tomography, intravascular ultrasound, modified balloons
- Medical subject headings
- Coronary Artery Disease, Angina, Stable, Coronary Stenosis, Myocardial Infarction, Cardiovascular Diseases, Myocardial Ischemia, Coronary Disease, Heart Diseases
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
ScoreFlex balloonDevice
Pre-dilatation with a ScoreFlex balloon
Device: standard non-compliant balloonDevice
Pre-dilatation with a standard non-compliant balloon
| Study group | Role | What they receive |
|---|---|---|
| ScoreFlex balloon | Active comparator | Pre-dilatation with a ScoreFlex balloon before implantation with a Magmaris bioresorbable scaffold Receives: Device: ScoreFlex balloon |
| Standard non-compliant balloon | Active comparator | Pre-dilatation with a non-compliant balloon before implantation with a Magmaris bioresorbable scaffold Receives: Device: Device: standard non-compliant balloon |
What is being measured
The primary outcome is the main question the study is designed to answer.
Minimal Lumen Area
Minimal Lumen Area
Measured: 6 months after index percutaneous coronary intervention
Secondary outcomes (4)
Change in remodeling Index
Change in remodeling Index
Measured: 6 months and 12 months after index percutaneous coronary intervention
Change in Minimal Lumen Area
Change in Minimal Lumen Area
Measured: 6 months and 12 months after index percutaneous coronary intervention
Percentage of incomplete scaffold apposition
Percentage of incomplete scaffold apposition
Measured: 6 months and 12 months after index percutaneous coronary intervention
Percentage of uncovered struts
Percentage of uncovered struts
Measured: 6 months and 12 months after index percutaneous coronary intervention
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted14 Dec 2020
- Study start14 Dec 2020
- Primary completion8 Mar 2024 (estimated)
- Study completion31 Dec 2024 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (2)Papers the sponsor has linked to this study.
- Other trials for Coronary Artery DiseaseStudies of the same condition, open and under way.
- More trials run by Odense University HospitalThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Model description
- Eligible patients randomized to predilatation with ScoreFlex balloon or a standard non-compliant balloon before percutaneous coronary intervention with implantation of a Magmaris bioresorbable scaffold.
- Masking
- Double blind
- Who is masked
- Investigator, Outcomes assessor
- Enrolment
- 82 participants (actual)
Sponsor and investigators
- Lead sponsor
- Odense University Hospital
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Kirstine Nørregaard Hansen, Odense University Hospital
- Investigators
- Lisette O. Jensen, MD PhD Prof, Study chair, Odense University Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04666584
- Sponsor's protocol ID
- Odense University Hospital
- Other IDs
- S-20200114
- Acronym
- OPTIMIS
- Status last verified
- Sep 2023
- First submitted
- 27 Nov 2020
- Last updated
- 13 Sep 2023
- Results posted
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Hansen KN, Maehara A, Troan J, Noori M, Hougaard M, Ellert-Gregersen J, Veien KT, Junker A, Hansen HS, Lassen JF, Jensen LO. Mechanistic insights into lumen reduction after implantation of a drug-eluting bioresorbable metallic scaffold assessed with serial intracoronary imaging: from the OPTIMIS trial. Coron Artery Dis. 2026 Mar 1;37(2):84-94. doi: 10.1097/MCA.0000000000001561. Epub 2025 Aug 20.
PubMed 40832681Hansen KN, Troan J, Maehara A, Noori M, Hougaard M, Ellert-Gregersen J, Veien KT, Junker A, Hansen HS, Lassen JF, Jensen LO. Optimal Predilatation Treatment Before Implantation of a Magmaris Bioresorbable Scaffold in Coronary Artery Stenosis: The OPTIMIS Trial. Circ Cardiovasc Interv. 2025 Jan;18(1):e014665. doi: 10.1161/CIRCINTERVENTIONS.124.014665. Epub 2025 Jan 21.
PubMed 39836741
Study at a glance
From the registry record, last updated by the sponsor on 13 Sep 2023. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Optimal Predilatation Treatment Before Implantation of a Magmaris Bioresorbable Scaffold In Coronary Artery Stenosis
- ClinicalTrials.gov ID
- NCT04666584
- Acronym / sponsor ID
- OPTIMIS / Odense University Hospital
- Conditions
- Coronary Artery Disease, Stable Angina, Coronary Artery Stenosis, Myocardial Infarction, Cardiovascular Diseases, Myocardial Ischemia
- Keywords
- bioresorbable scaffolds, optical coherence tomography, intravascular ultrasound, modified balloons
- Study type
- Interventional
- Recruitment status
- Unknown status
- Enrolment
- 82 participants (actual)
- Lead sponsor
- Odense University HospitalUniversity, hospital or other
- Study start
- 14 Dec 2020 (actual)
- Primary completion
- 8 Mar 2024 (estimated)
- Study completion
- 31 Dec 2024 (estimated)
- First posted
- 14 Dec 2020 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The aim of the study is to investigate if lesion preparation with a ScoreFlex balloon compared to a standard non-compliant balloon improve vascular healing and minimize lumen reduction after implantation of a Magmaris bioresorbable scaffold.
Detailed description
Introduction: Ischemic heart disease (IHD) is characterized by progressive atherosclerosis in coronary arteries and may cause coronary artery stenosis or acute thrombus and occlusion. IHD is often treated with percutaneous coronary intervention (PCI) with balloon dilatation and implantation of a stent. The drug-eluting stents (DES) have been developed to minimize neointimal growth after implantation and reduce the risk of in-stent restenosis compared to bare-metal stents (BMS). Newer devices, bioresorbable scaffold (BRS), are made from a bioresorbable material slowly dissolving after implantation. The BRS guarantees optimal vessel support after balloon dilatation and implantation, but the artery can obtain original function and flexibility after the BRS has vanished. The development of the Magmaris BRS, with its improved radial strength, thinner struts compared to previous BRSs, is developed to reduce the complications seen in earlier generation BRS such as recoil, fracture and late stent thrombosis.
Previous studies have shown that coronary lesions treated with the previous generation of the Magmaris BRS resulted on lumen area reduction, possibly a consequence by increased plaque burden, compromising the scaffold area, combined with increased neointimal formation in the early phase of vascular healing and fast resolution.
Due to decreased radial strength of the BRS compared to metal stents, modification of plaque prior to BRS-implantation is necessary. The ScoreFlex balloon is a non-compliant balloon with circumference of fixated, scoring elements and permits controlled expansion and fragmentation of calcified plaque, compared to standard treatments with a non-compliant balloon.
Intravascular imaging with Intravascular Ultrasound (IVUS) and Optical Coherence Tomography (OCT) can assess the morphology and location of plaques in the coronary stenosis prior to PCI thereby optimizing the implantation. The scaffold-treated segment can also be evaluated with intravascular imaging components such as stent coverage, malapposition and neointimal hyperplasia, but only if the scaffold is visible. If the scaffold is dissolved, another method to assess the vascular healing is needed. IVUS can evaluate change in elastic external membrane (EEM), change in remodeling and minimal lumen area (MLA). The reduction in MLA is associated with increased neointimal hyperplasia and plaque burden in the vessel wall.
The aim of the study is to investigate if lesion preparation with a ScoreFlex balloon compared to a standard non-compliant balloon improve vascular healing and minimize lumen reduction after implantation of a Magmaris bioresorbable scaffold.
Method: The study is designed as a prospective randomized trial conduced at a single center (Odense University Hospital, Denmark). Eighty-two patients with stable angina pectoris and non-ST-segment elevation myocardial infarctions are included, if they meet the criteria. Pre-dilatation with a 2.0 mm balloon is performed followed by pre-interventional IVUS and OCT. Patients are randomized to lesion preparation and pre-dilatation with either the ScoreFlex balloon or a standard non-compliant balloon with a 1:1 balloon-to-artery ratio by measuring the reference segments. The residual stenosis should be less than 20 %. If the pre-dilatation goal is not achieved, up-scaling to a balloon 0,5 mm larger is allowed. The lesion is treated with implantation of a Magmaris scaffold. Finally, IVUS and OCT-images of the final result are obtained. Follow-up IVUS and OCT images are performed after 6 and 12 months.
Post-PCI OCT-images are analyzed at baseline and 6 and 12 months after index procedure. Change in MLA in the stented segment is measured with IVUS and OCT. The vascular healing is based on finding from the OCT images.
The study is submitted and approved by the Regional Committees on Health Research Ethics for Southern Denmark (Project-ID: S-20200114) and Danish Data Agency (Journal nr.: 20/49900) Statistics: Assuming data are normally distributed, categorical data will be presented as numbers and frequencies and compared using chi2-test. Continuous data will be presented as mean ± SD and compared using Student t-test- SPSS version 26.0 will be used for the statistical analysis.
The estimated sample size is based on data, from the HONEST study by Fallesen et al. The reduction of MLA from 6.99 mm2 to 5.01 mm (27%) 6 months after implantation of a Magmaris BRS, represented the expected reference group. Optimal lesion preparation with pre-dilatation with a ScoreFlex balloon is estimated to minimize MLA reduction from 6.99 mm2 to 6.22 mm2 (11%). A power calculation is conducted using the expected MLA after 6 months (6.22 mm2 for the ScoreFlex balloon and 5.01 mm2 for the standard non-compliant balloon). Inclusion of 35 patients in each group is necessary to reach statistical significance in case of 2-tailed significance level of 0.05 and power of 80 %. Loss to follow-up and poor image quality finalize an expected drop-out rate of 15 %, thereby requiring 82 patients in total.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Double blind (investigator, outcomes assessor)
- Number of arms
- 2
- Model description
- Eligible patients randomized to predilatation with ScoreFlex balloon or a standard non-compliant balloon before percutaneous coronary intervention with implantation of a Magmaris bioresorbable scaffold.
| Arm | Type | Receives |
|---|---|---|
| ScoreFlex balloon | Active comparator | Device: ScoreFlex balloonPre-dilatation with a ScoreFlex balloon before implantation with a Magmaris bioresorbable scaffold |
| Standard non-compliant balloon | Active comparator | Device: Device: standard non-compliant balloonPre-dilatation with a non-compliant balloon before implantation with a Magmaris bioresorbable scaffold |
Who may qualify
- Ages
- 18 to 80 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (1 listed)
- Patients with stable angina pectoris and non-ST elevation myocardial infarction referred for invasive coronary angiography and percutaneous coronary intervention at Department of Cardiology, Odense University Hospital (Odense, Denmark)
Key exclusion criteria (9 listed)
- participation in other randomized clinical trials
- life expectancy < 1 year
- allergy to aspirin, clopidogrel, ticagrelor or prasugrel
- eGFR < 30 mL/min
- tortuous and angiographically estimated extremely calcified lesions
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| ScoreFlex balloonPre-dilatation with a ScoreFlex balloon | Device | ScoreFlex balloon |
| Device: standard non-compliant balloonPre-dilatation with a standard non-compliant balloon | Device | Standard non-compliant balloon |
Primary outcome
Minimal Lumen Area
Time frame: 6 months after index percutaneous coronary intervention
Minimal Lumen Area
4 secondary outcomes
Change in remodeling Index
Time frame: 6 months and 12 months after index percutaneous coronary intervention
Change in Minimal Lumen Area
Time frame: 6 months and 12 months after index percutaneous coronary intervention
Percentage of incomplete scaffold apposition
Time frame: 6 months and 12 months after index percutaneous coronary intervention
Percentage of uncovered struts
Time frame: 6 months and 12 months after index percutaneous coronary intervention
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 13 Sep 2023.
- Derived from this study: PubMed 40832681Hansen KN, Maehara A, Troan J, Noori M, Hougaard M, Ellert-Gregersen J, Veien KT, Junker A, Hansen HS, Lassen JF, Jensen LO. Mechanistic insights into lumen reduction after implantation of a drug-eluting bioresorbable metallic scaffold assessed with serial intracoronary imaging: from the OPTIMIS trial. Coron Artery Dis. 2026 Mar 1;37(2):84-94. doi: 10.1097/MCA.0000000000001561. Epub 2025 Aug 20.
- Derived from this study: PubMed 39836741Hansen KN, Troan J, Maehara A, Noori M, Hougaard M, Ellert-Gregersen J, Veien KT, Junker A, Hansen HS, Lassen JF, Jensen LO. Optimal Predilatation Treatment Before Implantation of a Magmaris Bioresorbable Scaffold in Coronary Artery Stenosis: The OPTIMIS Trial. Circ Cardiovasc Interv. 2025 Jan;18(1):e014665. doi: 10.1161/CIRCINTERVENTIONS.124.014665. Epub 2025 Jan 21.
- Individual participant dataSharing planned: No
Related trials for Coronary Artery Disease
Not yet recruiting
Effect of Stress Ball Use During Femoral Arterial Sheath Removal After Coronary Angiography
Femoral Arterial Sheath Removal, Stress Ball
Active, not recruiting
Shockwave™ vs Surgical Endarterectomy for Calcified Severe Common Femoral Artery Stenosis: Comparison of Efficacy, Safety and Long-Term Outcomes
Common Femoral Artery Stenosis, Calcification; Heart
Not yet recruitingPhase 4
Roxadustat and Myocardial Injury After Off-Pump Coronary Artery Bypass Surgery
Coronary Artery Disease, Coronary Artery Bypass Grafting
RecruitingObservational study
Preoperative Gastric Ultrasound and Left Ventricular Function in Coronary Artery Bypass Surgery
Coronary Artery Disease, Left Ventricular Systolic Dysfunction
Active, not recruiting
The OCTOBER Trial - European Trial on Optical Coherence Tomography Optimized Bifurcation Event Reduction (OCTOBER)
Ischaemic Heart Disease, Ischemic Heart Disease
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Lisette O. Jensen, MD PhD Prof study chair
Odense University Hospital
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing ScoreFlex balloon and Device: standard non-compliant balloon in people with Coronary Artery Disease and Stable Angina, run by Odense University Hospital at 1 site in Denmark.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 13 Sep 2023. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Denmark. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Minimal Lumen Area (time frame: 6 months after index percutaneous coronary intervention). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT04666584, which also lists 2 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 13 Sep 2023.